1. Home
  2. Explore
  3. Astronomy
  4. Finding Exoplanets with TESS

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

Finding Exoplanets with TESS

  • 44Unfamiliar
  • 0Learning
  • 0Familiar
  • 0Mastered
Topic: Transits and TESS
  • spaceFlip card
  • KI knew it
  • DI didn't know it
  • ←Previous card
  • →Next card

What is an exoplanet transit?

Tap to flipClick to flipspace

A transit occurs when a planet passes in front of its host star from the observer’s viewpoint, causing the star’s observed brightness to dip.

Or swipe the card

44 cards

  1. What is an exoplanet transit?

    A transit occurs when a planet passes in front of its host star from the observer’s viewpoint, causing the star’s observed brightness to dip.

  2. What does a transit look like in a stellar light curve?

    It appears as a dip in the star’s brightness over time.

  3. What can scientists learn from observing a planet’s transit?

    Transit observations can be used to derive information about the planetary system.

  4. What does TESS stand for, and what is its primary mission?

    TESS is the Transiting Exoplanet Survey Satellite. It surveys the sky for planets transiting nearby stars.

  5. What type of NASA mission is TESS?

    TESS is a NASA-sponsored Astrophysics Explorer-class mission.

  6. Why does TESS use a high, elliptical Earth orbit?

    The orbit provides an unobstructed view of its observing field, supports continuous light curves, and offers a more stable platform for precise photometry than a lower orbit.

  7. How are TESS’s four CCD cameras arranged, and what combined field of view do they provide?

    The cameras have adjacent fields of view arranged as a 4×14 \times 14×1 array, providing a combined field of view of 26∘×24∘26^\circ \times 24^\circ26∘×24∘.

  8. What is a TESS observing sector, and how long does one sector observe?

    A sector is one region of the sky observed by TESS; each sector is observed for about 27 days.

  9. How much of the sky had TESS observed approximately since its 2018 launch, and what did it find?

    It had mapped about 80% of the sky across the northern and southern hemispheres and detected thousands of planetary candidates.

  10. Where are TESS mission data publicly available?

    TESS data are publicly available through the MAST Archive.

  11. What are the three main TESS data products described in the tutorial?

    Full-frame images (FFIs), target pixel files (TPFs), and light-curve files.

  12. What do TESS full-frame images contain, and what cadences were described?

    FFIs cover the full sector. Their cadence was about 30 minutes in mission years 1–2 and 10 minutes in years 3–4.

  13. What is a target pixel file (TPF)?

    A TPF is a persistent cutout from an FFI focused on a selected target of interest.

  14. What cadences are available for TESS target pixel files?

    The described TPF cadences are 2 minutes and 20 seconds.

  15. What information do TESS light-curve files provide?

    They provide time-series brightness data for target-pixel-file objects, including products at 2-minute or 20-second cadence.

  16. What caused the change in FFI cadence between TESS mission years 1–2 and years 3–4?

    The cadence changed between the primary mission and the extended mission: from about 30 minutes to 10 minutes.

  17. Which three Lightkurve search functions are used to find the main TESS data products?

    search_tesscut(), search_targetpixelfile(), and search_lightcurve().

  18. Which Lightkurve search function is used to find FFI cutout data?

    search_tesscut().

  19. Which Lightkurve search function is used to find target pixel files?

    search_targetpixelfile().

  20. Which Lightkurve search function is used to find light-curve files?

    search_lightcurve().

  21. What is Lightkurve designed to help users analyze?

    Time-series brightness data for planets, stars, and galaxies.

  22. Which space-telescope missions does Lightkurve primarily support, and what other data can it analyze?

    It primarily supports Kepler and TESS data, but it can also analyze light curves from backyard telescopes.

  23. Which example target was used to demonstrate TESS data analysis, and what is the orbital period of its planet C?

    The example target was the nearby bright star Pi Mensae; planet C has an orbital period of about 6.276.276.27 days.

  24. What does SAP mean in a TESS light curve, and how is SAP flux calculated?

    SAP means simple aperture photometry. SAP flux is calculated by summing the brightness of pixels within an aperture.

  25. Why can SAP flux contain unwanted variations?

    Because it sums pixel brightness within an aperture, SAP flux can retain effects from spacecraft motion, noise, and other instrumental artifacts.

  26. What does PDC in PDC-SAP flux stand for, and how is PDC-SAP produced?

    PDC stands for pre-search data conditioning. PDC-SAP flux is SAP flux with long-term trends removed using co-trending basis vectors.

  27. Why might a beginner choose PDC-SAP flux when it is available?

    It is usually cleaner than SAP flux because it contains fewer systematic trends.

  28. What does flattening a light curve do when searching for a transit?

    It reduces broad trends in the light curve, making transit features easier to identify.

  29. How can a noisy interval caused by spacecraft jitter be handled in a light curve?

    Define a mask for the affected interval and apply it to exclude that data.

  30. What is the purpose of removing outliers from a light curve?

    It removes anomalous data points that can obscure the underlying signal.

  31. How can folding a light curve help reveal a planet transit?

    Folding arranges observations by orbital phase using a period and epoch, aligning repeated transits so they are easier to see.

  32. Why can binning folded light-curve data make a transit clearer?

    Binning combines data points, reducing scatter and uncertainty and making the transit easier to distinguish.

  33. What is the purpose of extracting a small cutout from an FFI for a target?

    It isolates a small region around the target instead of working with the entire sector image.

  34. What cutout size was used around the example target in the sector 1 FFI?

    A 10×1010 \times 1010×10 pixel cutout.

  35. Why must an aperture be defined when extracting a light curve from an FFI cutout?

    The cutout does not already have an aperture defined, so pixels to include in the target’s flux must be selected.

  36. What is an aperture mask, and what can influence its design?

    An aperture mask selects the pixels used to measure a target’s flux. Its design can be influenced by blending and other effects.

  37. How did the tutorial select pixels for an FFI aperture?

    It used a threshold mask, selecting pixels above a specified flux threshold.

  38. What threshold and number of selected pixels were used in the example aperture mask?

    A threshold of 10 selected 18 pixels.

  39. How is a light curve created from an FFI cutout after defining an aperture mask?

    Use the to_lightcurve function with the target mask to sum the selected pixels’ values for each image.

  40. What is pixel-level decorrelation (PLD) used for in TESS light-curve analysis?

    PLD is used to remove systematic trends, such as long-term variations caused by small spacecraft motions.

  41. How does PLD model systematic noise?

    It identifies trends in pixels surrounding the target and uses linear regression to combine them into a model of systematic noise, which is then subtracted from the uncorrected light curve.

  42. Why might a PLD analysis limit the number of PCA components?

    Limiting the number of components can help avoid overcorrecting the light curve; the example used three components.

  43. What did the PLD diagnostic display show in the example?

    It showed the original light curve, the fitted background that was removed, the applied spline, and the resulting corrected light curve.

  44. How did the corrected FFI light curve compare with the light curve-file result?

    Both showed the same transit, but the corrected FFI light curve was noisier and less precise, in part because the FFI data had a longer cadence.

Card 1 of 44
Card 1 of 44

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent