Advanced Neuroscience for Engineers

Engineering Sensors and Microfabricated Devices for Healthcare

Engineering and neural science

The brain is one of the body’s most complex organs, and many aspects of its function and disease remain difficult to understand. Studying brain activity can reveal how neural systems work and where engineering may help address clinical problems. Examples include epilepsy and seizures, Parkinson’s disease, brain tumours, and EEG-based brain–computer interfaces.

An engineering approach often involves acquiring signals from the body, processing them, and using them to detect or better understand a health problem. Sensors and devices can support this work by measuring electrical, mechanical, thermal, optical, or flow-related properties.

The same engineering principles can apply across different organs. A sensor-design or fabrication technique developed for one application may be adapted for another, provided it is suited to the relevant tissue, measurement, and clinical use.

Micro- and nanoscale fabrication

Many healthcare sensors are small devices whose overall dimensions may be millimetres while their functional features are much smaller. The relevant fabrication scales can range from micrometres to nanometres:

  • A human hair is roughly 50–80 micrometres thick.

  • Features around a few micrometres are already substantially smaller than a hair.

  • Nanometre-scale features are smaller still.

Microfabrication and nanofabrication provide methods for building sensors and other devices with these small-scale structures. Understanding fabrication is useful not only for neural devices but also for sensors applied to the heart, airways, cancer detection, infection, and drug delivery.


Heart applications

Arrhythmia and electrical mapping

A resting heart typically beats about 70–75 times per minute, though its rate normally increases during physical activity. A problem arises when the heart’s rhythm becomes abnormally fast or irregular. Arrhythmia refers broadly to abnormal heart rhythms; atrial fibrillation (A-fib) is an example in which the rhythm is irregular.

One cause of irregular rhythm is abnormal or misfiring electrical activity in the heart. To locate the problematic region, clinicians can guide a catheter—a flexible tube with electrical sensors at its tip—into the heart. Measurements from different regions allow electrical mapping of cardiac activity.

Once an area of abnormal activity is identified, clinicians may use a separate catheter to perform radiofrequency (RF) ablation. RF energy heats and damages the targeted tissue, interrupting its electrical activity and connectivity.

Contact force and haptic feedback during ablation

Ablation depends partly on the force with which the catheter tip contacts the heart tissue. The described target range is approximately 0.30.30.3–0.40.40.4 newtons, or roughly 30–40 grams of force.

  • Too much force may damage or ablate tissue beyond the intended area.

  • Too little force may result in incomplete treatment, allowing the abnormal activity to recur.

A key engineering gap is that a clinician may be able to see a force reading on a screen without physically feeling that force. This missing tactile sensation is called a lack of haptic feedback. A catheter that provides useful force sensing and haptic feedback could help clinicians judge tissue contact during the procedure.

A related challenge is ensuring that ablation penetrates the tissue fully through its thickness. The desired complete effect is called transmurality. Assessing whether the tissue has been adequately ablated is difficult because the heart is three-dimensional, while a simplified view of the treatment may appear two-dimensional.

Comparing left- and right-ventricular tissue

Another cardiac measurement problem is comparing the properties of the left ventricle (LV) and right ventricle (RV). A probe that contacts tissue and measures relevant properties could help clinicians identify differences between the two regions or detect changes that may indicate future deterioration.

Possible measurement methods include:

  • Near-infrared (NIR) sensing, which uses near-infrared light to examine tissue.

  • Electrical impedance tomography (EIT), which uses electrical measurements to infer properties or structure within tissue.

Combining sensing methods can provide complementary information about tissue and may be useful in applications beyond the heart.


Communicable and non-communicable disease

A communicable disease can be transmitted between people or through an infectious agent. COVID-19 and bacterial infections such as sepsis are examples.

A non-communicable disease is not transmitted from person to person. Many cancers and heart diseases fall into this category.

Sensor and chip technologies can support both categories. For example, a chip may detect viral proteins in a sample, while other devices may characterize cancerous tissue or measure changes in organs affected by non-communicable disease.


Tracheal inflammation and airway sensing

The trachea, or windpipe, carries air to and from the lungs. In some infants, particularly those who have been on a ventilator, the trachea may become inflamed. Inflammation can narrow part of the airway, restricting airflow in a way analogous to a partial obstruction in a hollow pipe.

Existing assessment methods include bronchoscopy and the use of a Kirschner wire. These methods may require specialist expertise or provide a relatively crude assessment. An engineered catheter could combine measurements that reveal both airflow and tissue condition.

Flow and force sensors

A proposed airway catheter could include two main types of sensors:

  • Flow sensors could measure airflow during breathing. A change in flow may help indicate where airway narrowing is present.

  • Force sensors could measure the response of tracheal tissue when the catheter contacts it. This response can provide information about tissue stiffness or viscoelastic behaviour.

Two force-sensing approaches are:

  • Piezoresistive sensing: applied force causes a change in electrical resistance.

  • Piezoelectric sensing: applied force produces an electrical response, such as a change in voltage.

Combining flow and force measurements could help distinguish changes in airflow from changes in the mechanical properties of the airway tissue.

Catheter movement and shape-memory actuators

A catheter must be manoeuvred into the appropriate position to make useful measurements. One proposed approach uses nitinol, a shape-memory alloy, as an actuator. A spring made from this material contracts when heated and returns toward its original state when cooled. Actuators arranged on different sides of a tube could help steer or bend the catheter within the airway.


Breast cancer detection and tissue characterization

Screening and diagnosis

Breast cancer is a serious disease, and late diagnosis can contribute to poor outcomes. Awareness and access to screening are important because a diagnostic technology has limited value if people cannot reach it or do not know when to seek assessment.

The described assessment pathway includes several stages:

  1. Self-awareness or self-examination: noticing possible changes, such as a lump, inflammation, or unusual discharge. This can encourage someone to seek care but is not itself a definitive diagnosis.

  2. Clinical breast examination: a clinician examines the breast.

  3. Imaging: suspicious findings may lead to mammography or MRI.

  4. Needle biopsy: a tissue sample may be taken from a suspicious region.

  5. Pathological assessment: a pathologist examines tissue and relevant markers to determine whether cancer is present and to characterize it.

A barrier can occur between noticing a problem and receiving a clinical examination. Portable screening tools could help extend assessment beyond major clinics, including to community screening settings.

Breath analysis and volatile organic compounds

One proposed non-invasive screening approach is a breath analyser, sometimes described as an electronic nose. It would detect patterns of volatile organic compounds (VOCs) in exhaled breath.

The underlying idea is that the VOC profile in the breath of people with a particular disease may differ from that of people without it. A device could screen for such patterns without inserting a sensor into the body. Breath analysis would be a screening approach, not by itself a definitive cancer diagnosis.

Electrical, thermal, and mechanical tissue measurements

A small amount of biopsy tissue could also be assessed using combined electrical, thermal, and mechanical (ETM) measurements. These modalities examine different properties of the tissue and could help distinguish normal from cancerous tissue.

Such a tool could be valuable in cases where the usual pathological markers are absent. For example, triple-negative breast cancer lacks three commonly assessed markers but is still cancerous. The material describes this subtype as about 12% of breast cancer cases and presents ETM-based assessment as a potential way to characterize tissue beyond those markers.

Intraoperative probes and tumour boundaries

After a diagnosis, surgery may remove the cancerous tissue; this removal is called resection. Surgeons need to know whether cancer remains at the edges of the removed region. A pen-like probe that measures tissue during surgery could help distinguish normal from cancerous tissue in real time.

A probe might combine one or more modalities, such as electrical, mechanical, thermal, NIR, or ultrasound sensing. It could be used to characterize tissue in vivo, meaning within the living body. Determining the tumour boundary—where cancerous tissue ends and normal tissue begins—is an important related challenge.

In vivo, ex vivo, and in vitro

These terms describe where an experiment is performed:

  • In vivo: within a living organism or body.

  • Ex vivo: on tissue removed from the body, such as a biopsy sample.

  • In vitro: in a laboratory setting, often involving cells grown or studied outside the body.

These distinctions matter when interpreting results because tissue behaviour and experimental conditions can differ between a living body, removed tissue, and laboratory cell cultures.


Oral cancer and cell-based screening

Oral cancer can occur in regions such as the inside of the cheek, the floor of the mouth, or beneath the tongue. Tobacco and betel nut are among the risk factors described. A practical challenge is making screening accessible to people in remote locations and distinguishing cancerous changes from inflammation or other conditions.

Cytology and histology

A common cell-sampling method uses a swab to collect cells from the mouth. The cells can be spread on a glass slide and stained, for example with H&E staining, for examination.

  • Cytology is the study of individual cells.

  • Histology is the study of tissues.

In the described diagnostic framework, cytology is useful for faster screening, while histology is treated as the more definitive, or gold-standard, tissue assessment.

A pathologist may examine cell features such as the ratio of the cell to its cytoplasm, the presence of multiple nuclei, and other morphological characteristics. Cell morphology can change as disease develops, including during precancerous or premalignant stages.

Image processing and AI-assisted screening

Subtle premalignant changes can be difficult to recognize consistently. Image-processing methods and artificial intelligence could be trained on many cell images to identify abnormal or atypical morphology.

A possible workflow for community screening is:

  1. A trained or semi-skilled worker collects a swab.

  2. The sample is stained and placed on a slide.

  3. A scanning microscope captures the slide image.

  4. Software identifies cells with potentially atypical morphology.

  5. Selected images are sent to a pathologist for further review.

This approach could help prioritize cases and connect local screening sites with specialist expertise. It would support, rather than replace, clinical and pathological judgement.

A second proposed approach is a probe used directly within the oral cavity. Such a device could assess tissue at the site, potentially detecting small changes that may not be obvious by visual examination.


Protein–protein interactions and sensor surfaces

Some sensors detect a biological target by using the interaction between two proteins. A common example is the binding of an antibody to an antigen.

Antibody structure and orientation

An antibody is often simplified as a Y-shaped molecule:

  • The Fc region forms the stem of the Y.

  • The Fab regions contain the antigen-binding sites.

For a sensor to capture an antigen effectively, antibodies must be attached to the sensor surface in a useful orientation. If they attach in the wrong direction, their binding sites may be blocked or poorly positioned.

Surface chemistry

Surface chemistry describes the chemical treatment of a device surface that allows biological molecules to attach in a controlled way. In a sensor with gold electrodes, surface treatment can help anchor antibodies through the Fc region while leaving the Fab binding sites available to capture antigens. PEG-based surface treatments are one type of chemistry mentioned for helping control antibody attachment and orientation.

After target molecules bind, the sensor may detect a change in electrical impedance or electrochemical impedance. The same general principle can be adapted to different targets, including viral proteins, bacteria, or proteins associated with disease.


Detecting cancer spread through lymph-node analysis

Cancer can be described as primary or secondary, and as non-metastatic or metastatic. Metastasis occurs when cancer spreads from its original location to other parts of the body; spread can involve lymphatic pathways and lymph nodes.

Lymph nodes are part of the immune system. During some operations, clinicians may remove lymph nodes to assess whether cancer has spread. Removing nodes unnecessarily can affect immune function, so a rapid way to determine whether cancer-associated proteins are present could help guide decisions.

A sensor based on electrical or electrochemical impedance could be designed to detect relevant proteins in lymph-node tissue during surgery. The goal is to provide information quickly enough to support intraoperative decision-making.


Rapid testing for neonatal sepsis

Sepsis is a dangerous response to infection. In newborns, waiting several days for conventional laboratory results can be particularly risky.

A chip-based test could aim to identify bacteria more quickly. The described approach involves:

  • Recognizing that blood contains red blood cells, which may complicate measurement.

  • Separating plasma from blood, for example by centrifugation, so that red blood cells settle.

  • Testing the plasma for bacterial presence or concentration using a sensor chip.

Rapid detection could shorten the time between sampling and useful results. For neonatal care, even reducing a multi-day wait to a few hours could be clinically important.


Neonatal hearing screening

Hearing screening in newborns can use auditory brainstem response (ABR) measurements, also referred to in the material by the term BAER. The test assesses neural responses to sound and helps determine whether a newborn may have a hearing problem.

Access is a major concern: specialized equipment can be expensive and may not be available in all primary health centres. If hearing loss is not identified until a child is older, it may affect speech development, brain development, and broader cognition. Accessible screening can therefore support earlier identification and follow-up.


Drug-delivery devices

Intramuscular epinephrine delivery

Severe allergic reactions can be life-threatening. Epinephrine can be delivered into a muscle to help counter the reaction while the person seeks emergency care. An auto-injector such as an EpiPen is designed to deliver the drug through a needle, typically into the thigh.

A device described as an “EpiShot” uses a different design approach intended to make operation possible with one hand. Safety features described include:

  • Requiring the device to be placed against the body and pressed appropriately before drug delivery.

  • Preventing delivery from a simple button press alone.

  • Retracting the needle after delivery.

The design is also intended to be reusable and less expensive than the commercial device discussed. These features describe a device-development goal, not a substitute for clinical guidance or emergency care.

Microneedle patches

Another approach uses small polymer microneedles attached to a patch. Unlike conventional steel needles, these polymer needles are designed to be absorbed or biodegraded in the body without causing toxicity. They may deliver a drug while causing less discomfort, partly because they are designed not to reach deeper structures associated with pain.


Central engineering principles

Across these applications, several recurring ideas emerge:

  • Sensors connect biological processes to measurable signals. Electrical, mechanical, thermal, optical, and flow measurements can reveal different aspects of tissue or disease.

  • Device design must fit the clinical task. A sensor intended for surgery, community screening, or laboratory testing has different requirements for size, safety, usability, and measurement speed.

  • Combining modalities can improve characterization. A single measurement may not capture the full difference between healthy and diseased tissue.

  • Accessibility is part of the engineering problem. A tool is more useful when it can be operated in the settings where people need screening or treatment.

  • Engineering supports clinical judgement. Probes, chips, image analysis, and feedback systems can provide information to clinicians, but diagnosis and treatment decisions require appropriate clinical evaluation.

In neural science, these principles apply to devices that measure or interact with brain activity, including systems for studying epilepsy, Parkinson’s disease, brain tumours, and EEG-based brain–computer interfaces.