Core ideas
Osmosis and dialysis both involve the movement of substances across a membrane separating two solutions. They differ mainly in what the membrane allows to pass:
In osmosis, the membrane is treated as permeable to water but not to the solutes being considered.
In dialysis, the membrane allows water and some small dissolved molecules to pass, while restricting larger molecules.
Both processes are passive: substances move in response to concentration differences, without requiring cellular energy.
Solutions and membranes
A solution is a homogeneous mixture containing a solvent and one or more solutes. The solvent is the dissolving medium and is usually the component present in the greatest amount. In aqueous solutions, water is the solvent. Solutes are the substances dissolved in it, such as salts, sugars, or proteins.
A membrane separates the solutions. Its permeability depends on properties such as pore size and the size of the molecules or ions involved.
Semipermeable membranes
A semipermeable membrane permits water to cross while preventing the passage of the solutes being considered. This creates the conditions for osmosis. Cell membranes approximate this kind of selective barrier, although real cell membranes have more complex transport properties.
Differentially permeable membranes
A differentially permeable membrane—also called selectively permeable—permits some substances to cross but restricts others. In dialysis, water and certain small molecules can cross the membrane, while larger molecules such as starch and many proteins are generally retained.
The membrane does not necessarily treat all small substances alike: whether a substance can pass depends on its size and the membrane’s properties. If a permeable solute is more concentrated on one side, it tends to diffuse toward the side where its concentration is lower.
Osmosis and tonicity
Osmosis is the net movement of water across a semipermeable membrane in response to a difference in solute concentration. Water tends to move from the side with a higher water concentration and lower concentration of non-passing solutes toward the side with a lower water concentration and higher concentration of those solutes.
Tonicity describes how a solution affects water movement and cell volume relative to another solution, commonly the solution inside a cell. Tonicity is therefore comparative: a solution is called isotonic, hypertonic, or hypotonic with respect to another solution.
Isotonic solutions
An isotonic solution has the same effective concentration of solutes as the comparison solution. Across a membrane separating isotonic solutions, there is no net movement of water in either direction. Water molecules still move across the membrane, but the opposing movements balance.
Solutions used for intravenous fluids are formulated to be approximately isotonic with body fluids so that they do not cause cells to gain or lose excessive water.
Hypertonic solutions
A hypertonic solution has a higher effective solute concentration than the comparison solution. Its water concentration is correspondingly lower, so water moves toward the hypertonic side.
When a cell is placed in a hypertonic environment, water leaves the cell. The cell loses volume and mass and may shrink; sufficiently severe water loss can damage or kill the cell.
Hypotonic solutions
A hypotonic solution has a lower effective solute concentration than the comparison solution. Water moves from the hypotonic side toward the side with the higher effective solute concentration.
When a cell is placed in a hypotonic environment, water enters the cell. The cell gains volume and mass and may swell. If too much water enters, the cell can be damaged.
Key relationship: In osmosis, water moves toward the side with the higher concentration of solutes that cannot cross the membrane.
How the laboratory models osmosis
Potato tissue provides a model for studying how cells respond to solutions of different tonicities. Potato cell membranes separate the cell contents from the surrounding solution.
The experiment uses potato plugs in three environments:
Isotonic treatment: A sodium chloride solution of approximately 0.9% is used as the expected isotonic treatment in the laboratory model.
Hypertonic treatment: A more concentrated sodium chloride solution, such as 20%, provides a hypertonic environment.
Hypotonic treatment: Distilled water contains essentially no dissolved solute and is therefore hypotonic relative to the potato cell contents.
The 0.9% solution is commonly treated as isotonic to mammalian cells. The exact response of potato tissue can depend on its internal solute concentration, so the potato’s observed changes are important evidence rather than something to assume.
Procedure and observations
Cut potato plugs to approximately equal dimensions, such as about 40 mm in length.
Blot each plug so that its surface is dry to the touch without squeezing out its internal water.
Record each plug’s initial length and mass, and note its appearance or firmness.
Place the plugs in their assigned solutions for the specified period.
Remove and blot them in the same manner as before.
Record their final length and mass, and compare their texture and appearance with the initial observations.
The observations connect water movement to changes in tissue. A plug in a hypertonic solution is expected to lose water and become lighter or less firm. A plug in a hypotonic solution is expected to gain water and become heavier or firmer. A plug in an approximately isotonic solution should show less net change.
A useful way to quantify mass change is:
A positive result indicates a mass gain; a negative result indicates a mass loss.
Dialysis and diffusion
Dialysis is the separation of dissolved substances using a differentially permeable membrane. Water and small permeable solutes can cross the membrane, while larger or otherwise restricted substances remain on their original side.
The direction of movement for a permeable solute depends on its concentration gradient. For example, if glucose can cross the membrane and its concentration is higher inside a dialysis tube than outside, glucose tends to diffuse outward. If its concentration is higher outside, it tends to diffuse inward.
Dialysis can occur alongside osmosis. Water may move in response to differences in non-permeating solutes while small permeating solutes diffuse down their own concentration gradients.
Dialysis tubing model
Dialysis tubing is used as a model of a selectively permeable membrane. It is hydrated before use, opened carefully, and sealed at one end. A mixture containing glucose and starch is placed inside, and the other end is sealed. The tubing is then immersed in distilled water.
Glucose and starch are useful together because their molecules differ greatly in size:
Glucose is small enough to pass through many dialysis membranes.
Starch consists of much larger molecules and is generally too large to pass through the tubing.
For a mixture containing glucose and starch inside the tubing, the expected results are:
Glucose diffuses from the tubing into the surrounding water if its concentration is initially higher inside.
Starch remains inside the tubing because its molecules are too large to pass through.
Water can cross the tubing. Because the contents contain solutes and the surrounding distilled water has very little solute, water may also move into the tubing.
These results demonstrate why dialysis and osmosis are related but distinct: dialysis describes the selective passage of dissolved substances through a membrane, while osmosis specifically describes water’s net movement across a membrane.
Tests for starch and reducing sugars
Iodine test for starch
An iodine solution is used to detect starch. If starch is present, the solution develops a dark blue, purple, or blue-black color. If starch is absent, that characteristic dark color does not develop.
In the dialysis-tubing model, the solution outside the tubing should not give a positive starch test if the starch has been retained inside the membrane.
Benedict’s test for reducing sugars
Benedict’s solution is used to detect reducing sugars, including glucose. The test mixture is heated, usually in a hot-water bath, because the reaction proceeds slowly at room temperature.
Benedict’s solution contains blue copper(II) ions. A reducing sugar can reduce copper(II) to copper(I), producing a colored precipitate. In simplified form, the reduction is represented as:
The color can range from green through yellow and orange to brick red. In general, stronger color changes indicate a greater amount of reducing sugar, so the test is semi-quantitative rather than an exact measurement of concentration.
In the dialysis model, a positive Benedict’s test on the surrounding water indicates that a reducing sugar, such as glucose, has crossed the membrane. The test is not unique to glucose: other reducing sugars can also produce a positive result.
Hemodialysis as an application
Hemodialysis uses a differentially permeable membrane to help remove waste products from a person’s blood when the kidneys cannot adequately perform that function. Blood flows through a membrane-based device while dialysate flows on the other side.
The dialysate is formulated so that needed components, such as important electrolytes, are maintained at appropriate concentrations. Waste substances such as urea are kept at lower concentrations in the dialysate than in the blood. This concentration difference causes waste molecules to diffuse from the blood into the dialysate. The membrane retains blood cells and many large molecules, such as proteins.
The central principle is the same as in the laboratory model: small permeable substances move down concentration gradients, while the membrane restricts larger substances. The composition of clinical dialysate is carefully controlled; it is designed to remove selected wastes while helping maintain the body’s balance of water and essential solutes.
Preparing sodium chloride solutions
For the laboratory calculations, the percentage concentration is interpreted as mass per volume: grams of sodium chloride per 100 mL of final solution. Under this convention, a 0.9% sodium chloride solution contains 0.9 g of sodium chloride per 100 mL of solution.
The required mass for a target volume is found by scaling the mass-to-volume ratio.
Preparing 50 mL of 0.9% sodium chloride
Therefore, 0.45 g of sodium chloride is needed to prepare 50 mL of a 0.9% solution.
Preparing 50 mL of 20% sodium chloride
Therefore, 10 g of sodium chloride is needed to prepare 50 mL of a 20% solution.
The solution should be brought to a final volume of 50 mL; the calculation does not mean that the salt is added to 50 mL of water.
Laboratory safety
A hot-water bath can cause scalds, so heated containers and solutions should be handled carefully.
Iodine solution can stain skin and clothing and should be kept away from the eyes.
Glassware can break and cause cuts. Eye protection is essential when working with laboratory glassware and reactive solutions.
Appropriate laboratory clothing includes protective eyewear, disposable gloves, a lab coat, closed-toe shoes, and clothing that covers exposed legs.

Ask anything