Seminar Intro & PFAS Talk
Use of Industrial Gases in Water and Wastewater Treatment
Air Separation and Oxygen Production
The Air Separation Unit (ASU)
Industrial oxygen is produced via air separation units (ASUs) that use the Joule-Thompson effect: compressing clean air and then expanding it causes cooling, allowing separation by distillation based on different boiling points of nitrogen (−196∘C), oxygen (−183∘C), and argon (−186∘C).
The distillation column separates air into nitrogen, oxygen, and argon fractions.
Liquid products (LOX, LIN) are stored and shipped in cryogenic trailers to end users.
Industry terminology: "A100" means the plant produces 100 tons per day of oxygen and 100 tons per day of nitrogen; "L200" means 200 tons per day of liquid products.
Oxygen Solubility in Water
At atmospheric pressure and 56°F (13.3°C), the maximum dissolved oxygen (DO) from air is about 8 parts per million (ppm).
Pure oxygen can achieve more than 5 times that concentration (over 40 ppm) because the partial pressure of oxygen is much higher (air is only 21% oxygen).
Increasing total pressure further raises DO: at 100 psi, DO can exceed 100 ppm.
Temperature effect: higher water temperature decreases oxygen solubility. For example, warm water holds less dissolved oxygen than cold water.
Why Pure Oxygen Is Preferred
Pure oxygen provides five times more dissolved oxygen than air at the same pressure.
Total gas flow with pure oxygen is 12–100 times lower than with air. Less inert gas (nitrogen) means reduced stripping of volatile organic compounds (VOCs) and less foaming.
Dissolved Oxygen (DO) in Wastewater Treatment
Oxygen is essential for aerobic biological processes that break down organic pollutants. Maintaining adequate DO prevents anaerobic conditions and odor problems.
Key Terms
DO: Dissolved oxygen concentration in water (mg/L or ppm).
BOD (Biochemical Oxygen Demand): Amount of oxygen required by microorganisms to decompose organic matter.
COD (Chemical Oxygen Demand): Amount of oxygen needed to chemically oxidize pollutants.
MLVSS (Mixed Liquor Volatile Suspended Solids): Measure of active biomass in an aeration basin.
Factors Affecting Oxygen Transfer Efficiency
Depth of water: Each 1 meter (≈3 ft) depth provides about 16% oxygen utilization. Deeper systems allow near 90–100% efficiency.
Water temperature: Higher temperatures reduce DO and transfer efficiency.
Flow rate and oxygen concentration target.
Bubble size: Smaller bubbles have larger surface area per unit volume, increasing transfer rate. If bubble diameter is halved, surface area doubles.
BIOX System
The BIOX hose is a maintenance-free oxygenation device made of EPDM rubber with self-closing flapper holes (less than 10 microns in size). When oxygen is supplied, holes open; when flow stops, they close — preventing clogging.
Used in Europe for 15–20 years with consistent quality.
Bubble size is controlled by oxygen flow; smaller bubbles improve dissolution.
No electricity required at the point of use because pressurized oxygen comes from vaporizing liquid oxygen (1 liter of liquid yields ~600 liters of gas).
Comparison: BIOX vs. Aerators
BIOX (pure oxygen hose)
Low investment cost
High oxygen transfer efficiency
No power consumption at use point
Very low maintenance (no moving parts)
Flexible: oxygen flow easily adjusted to meet DO demand
Noiseless, minimal smell
Continues working during power outages
Aerators (surface or diffused air)
High investment and installation cost
Lower oxygen transfer efficiency
High electricity consumption
High maintenance (membranes age, holes enlarge, efficiency drops)
Fixed operation, less flexible
Can cause odor and VOC stripping
Data examples from the presentation:
Oxygen transfer rate per kWh is dramatically higher for pure oxygen systems.
MLVSS levels are significantly higher with pure oxygen.
Total gas flow is far lower, reducing VOC emissions.
Applications in Wastewater Treatment
Odor Control
Odor in wastewater plants is primarily caused by anaerobic conditions that produce hydrogen sulfide (H2S) and other volatile sulfur compounds. The first collection basin often goes anaerobic due to high BOD/COD loads.
Solution: Inject oxygen (via BIOX hose or similar) to maintain positive DO levels (1–5 ppm). This eliminates anaerobic conditions and stops smell at the source.
Example from the speaker: A plant in a residential area eliminated odor complaints after installing oxygen injection in the collection basin. Neighbors now notice if the system is turned off.
Alternative odor control methods (e.g., chemical scrubbers) can cost millions; oxygen injection can be a much simpler, lower-cost solution (< $1 million for many plants).
VOC Reduction
EPA regulations limit VOC emissions from wastewater facilities. Using pure oxygen instead of air reduces total gas flow by 12–100 times, significantly lowering the amount of volatile organics stripped from the water.
Less turbulence means less VOC escape. VOCs remain in the liquid phase where biological treatment can break them down.
This helps facilities comply with emission limits without additional capture equipment.
Other Benefits
Improved sludge settling — better DO enhances microbial activity and floc formation.
Reduced plant operating cost — lower electricity bills and less maintenance.
Electricity outage resilience — oxygen systems function without power, preventing process upsets and odor events.
Fish Farming (Aquaculture)
High-density fish farming requires adequate dissolved oxygen, especially during nighttime and feeding periods when oxygen demand peaks.
Fish need oxygen delivered to their gills; when DO is low, they become stressed, stop feeding, and may die.
Pure oxygen injection can maintain DO at desired levels (e.g., above 5 ppm) 24/7.
Benefits:
Higher DO levels — reduces fish stress and mortality, especially from 12 midnight to 4 a.m. (critical period).
Faster growth — fish convert feed more efficiently, improving feed conversion ratio.
Higher population density — more fish per pond because oxygen is not limiting.
Reduced equipment needs — no paddlewheel aerators or tractors needed, saving electricity and maintenance.
Fish congregate near oxygen source, making harvesting easier.
Reduced fish loss during handling, high temperature, or other stress events.
Carbon Dioxide for pH Control
Carbon dioxide (CO2) dissolves in water to form carbonic acid (H2CO3), a weak acid that gently lowers pH without the hazards of strong mineral acids.
Comparison: CO2 vs. Strong Acids (HCl, H₂SO₄)
Carbon Dioxide (CO2)
Weak acid — virtually no risk of pH overshoot
No operator handling; gas is injected directly into water
No special PPE required
No pumps to maintain (uses existing gas pressure)
Lower overall cost per year (depending on dosage)
Strong Mineral Acids (HCl, H₂SO₄)
Strong acids — can overshoot pH, causing low-pH excursions and potential violations
Requires handling with safety equipment (PPE) and trained personnel
Risk of employee burns, acid spills; pumps require routine replacement
Higher maintenance and safety costs
Applications of CO2 for pH Control
Effluent streams prior to discharge (compliance with pH permits)
Paper and pulp process water (alkaline streams)
Textile manufacturing effluent
Concrete and mining operations (lime-rich, high pH)
Any industrial facility with high-pH wastewater
Regulatory impact: Eliminates fines for pH violations, reduces lost-time accidents and liability.
Ozone for Water Sterilization
Ozone (O3) is a powerful disinfectant that kills bacteria, viruses, and other organisms. It is generated on-site using oxygen (O2) and an ozone generator.
Used in drinking water treatment, especially in developing countries for clean water provision.
Effective sterilizing agent that decomposes into oxygen, leaving no harmful residuals.
Gas Cylinder Tool: Unidirectional, Spark-Free, Antibacterial Wrench
Technology Services Inc. developed a patented multifunctional tool for safely operating compressed gas cylinders — including opening caps, mounting regulators, and opening valves.
Key Features
Unidirectional ratchet mechanism — prevents applying excessive torque when opening; closing is done by hand only, avoiding damage to valve stems.
Spark-free — essential for flammable gas environments (e.g., welding). Bronze alloy construction prevents sparks.
Antibacterial — copper alloy kills 99.9% of bacteria within 2 hours (EPA-registered). Useful in hospitals, pharma, biotech, and labs.
Functions
Open/close cylinder cap (no need for wrench, screwdriver, hammer).
Mount and tighten CGA regulators (Series 300 and 500). Not for Series 600 (toxic gases).
Open cylinder valve using ratchet end with pins that seat in valve wheel grooves.
Operate medical gas cylinder valves (large hole on attachment arm).
Operate welding gas cylinder valves (smaller hole on attachment arm).
Benefits
Replaces multiple tools (wrenches, screwdrivers, hammers) with one.
Enhances safety: spark-free, no excessive torque, antibacterial surface for medical settings.
Affordable and ergonomic.
Available in different alloys; bronze is recommended for antibacterial and spark-free.
Q&A Insights: Cost, Reliability, and Mechanisms
Cost-Benefit of Oxygen vs. Air
Return on investment for oxygen systems in wastewater is typically less than three years, considering savings from electricity, maintenance, odor control, and compliance.
Oxygen supply cost depends on the mode: liquid oxygen (tank on-site), on-site generation, or pipeline. Pipeline contracts can lock in prices for 15+ years.
Transportation cost is the biggest factor; being within 250 miles of an ASU gives competitive pricing.
Competition among gas suppliers helps control prices long-term.
Reliability of Oxygen Supply
Large users (steel mills, chemical plants) can justify building a nearby ASU, which then serves regional customers.
Liquid oxygen can be stored and replenished on schedule; multiple suppliers exist.
The cost of oxygen must be weighed against the full value of improved process performance, not just electricity offset.
How Oxygen Reduces Odor and VOC
Odor: Anaerobic conditions produce H2S. Maintaining positive DO (1–5 ppm) prevents anaerobic metabolism altogether, stopping odor at the source.
VOC emissions: Pure oxygen greatly reduces total gas flow through the liquid. Less inert gas (nitrogen) means fewer volatile compounds are stripped into the air. VOCs remain in the water where biological treatment can remove them, helping facilities meet EPA emission standards.
Fermentation example: Switching from air (1000 CFH) to pure oxygen (200 CFH) in a pilot fermenter increased yield by 30% and productivity by 10% — because inerts were eliminated and DO level stabilized at the optimum concentration for the microorganisms.
These notes cover the complete range of topics from the seminar: oxygen production and solubility, wastewater treatment aeration and odor control, aquaculture, pH control with CO₂, ozone sterilization, and the specialized gas cylinder wrench. All data and examples are drawn directly from the presented material.