Structural Analysis Toolkit for Nastran — Study Notes

The Structural Analysis Toolkit is a standalone post-processing and dynamic-analysis environment developed to extend the capabilities of MSC Nastran and NX Nastran. It reads Nastran result files, especially binary $op2$ files, and provides specialized processors for modal, harmonic, random-vibration, energy, and response analyses.

The toolkit is designed to:

  • Process Nastran modal and dynamic results efficiently.

  • Identify important modes and structural regions.

  • Calculate responses to base excitation.

  • Account for modal truncation.

  • Generate stress, displacement, acceleration, velocity, energy, and margin-of-safety results.

  • Export results to text, Excel, XML, universal, binary, HTML, and NX-compatible formats.

  • Support both interactive use through a graphical interface and automated command-line or batch execution.


1. Toolkit Architecture and Main Capabilities

1.1 Relationship to Nastran and NX

The toolkit does not replace Nastran. Instead, it operates primarily on Nastran-generated result files.

A typical workflow is:

  1. Build and solve a finite-element model in NX or MSC Nastran.

  2. Request the required results in the Nastran input file.

  3. Run Nastran to generate the $op2$ result file.

  4. Open the $op2$ file in the toolkit.

  5. Select a processor and define the desired output.

  6. Run the processor.

  7. Review the generated numerical results, plots, contours, and reports.

The toolkit supports results from both MSC Nastran and NX Nastran, although the exact output format and available data blocks may depend on the solver version and requested outputs.

1.2 Main processors

The major processors discussed are:

  • Modal processor

    • Summarizes modal properties.

    • Identifies effective mass and modal participation.

    • Helps determine whether the modal basis is sufficient.

  • Energy processor

    • Calculates kinetic and strain energy by mode and by model group.

    • Helps identify which components participate most strongly in a mode.

  • Sign processor

    • Calculates steady-state harmonic response to deterministic base excitation.

    • Produces response quantities, stress results, plots, and margins of safety.

  • Random processor

    • Calculates statistical response to random base excitation.

    • Uses power spectral density input.

    • Produces RMS, peak, stress, composite failure metrics, and margin-of-safety results.

The toolkit also provides general result and report utilities, including HTML, Excel, XML, text, universal-file, and NX-compatible output.


2. Input Files, Result Files, and Project Definitions

2.1 $op2$ files

The toolkit reads Nastran binary $op2$ files. These files contain result data blocks generated by a Nastran solution.

The available processors depend on the information stored in the $op2$ file. For example:

  • A modal processor requires modal results.

  • A random or harmonic processor requires modal data and appropriate output requests.

  • Stress post-processing requires stress results to have been requested during the Nastran solution.

  • Effective-mass processing requires modal effective-mass information.

If an expected processor is unavailable, the $op2$ file may not contain the data required by that processor.

2.2 Full opening versus quick opening

The toolkit supports two ways of opening an $op2$ file:

Full opening

A full opening scans the file and identifies the data blocks it contains. This is useful for large or complex models because the user can see which results are available before selecting a processor.

Quick opening

A quick opening avoids scanning the complete $op2$ file. It is faster, but it requires the user to know which processors and result blocks are available.

Quick opening is useful when:

  • The result file is very large.

  • The user already knows the contents of the file.

  • Processing needs to be repeated efficiently.

2.3 Definition files

Each processor uses a definition file that specifies the analysis settings. These files generally contain:

  • Input $op2$ file information.

  • Load cases or subcases.

  • Frequency ranges or frequency sets.

  • Selected groups.

  • Output requests.

  • Damping values.

  • Modal truncation settings.

  • Result formats.

  • Stress and margin-of-safety settings.

The definition file allows the processor to be run independently of the graphical interface. It can also be manually edited when repeated analyses or specialized settings are required.

Definition files should be edited carefully because the processor expects a particular structure and keyword arrangement. Invalid placement or syntax can cause parsing errors.

2.4 Project files

The toolkit creates project-specific files associated with the selected processor. Default names are generally based on the $op2$ filename and the processor type, but the user can specify custom project names.

The project interface can display files associated with a project, although some project-management functions are limited compared with the analytical processors.


3. Group Definition and Universal-File Import

3.1 Purpose of groups

Groups allow the user to process only selected parts of a model or to organize a full model into meaningful structural regions.

Groups can be used to:

  • Compute energy by component.

  • Limit stress or response processing to selected regions.

  • Identify which parts of an assembly respond most strongly.

  • Generate component-level reports.

  • Reduce the amount of output data.

Examples of useful groups include:

  • Main reflector.

  • Side panels.

  • Feed structure.

  • Mounting structure.

  • Brackets.

  • Fastener regions.

  • Individual materials or physical-property regions.

3.2 Element requirement

The toolkit processes elements, not merely mesh containers or graphical mesh objects.

Some preprocessing environments automatically place mesh objects into groups instead of the individual elements. Such a group may appear correct visually but still be unusable by the toolkit.

A valid group must contain:

  • Individual finite elements.

  • The element identifiers needed for result extraction.

If a group contains only mesh objects, it may be skipped during export.

3.3 Exporting groups from NX

A typical NX workflow is:

  1. Define groups in the finite-element model.

  2. Ensure that the groups contain elements.

  3. Select the appropriate solver and solution.

  4. Export the simulation data in universal-file format.

  5. Import the universal file into the toolkit.

When a group contains no elements, the export process reports that the group was skipped.

3.4 Group-based analysis

After importing groups, the toolkit can:

  • Move selected groups into an active-processing list.

  • Assign custom group labels.

  • Process strain or kinetic energy by group.

  • Generate group-specific stress or response results.

  • Sort results by group, mode, frequency, or response magnitude.

Group analysis is particularly valuable for assemblies because it shows not only which modes are important, but also which structural components are responsible for the response.


4. Output Formats and Reporting

The toolkit can generate several kinds of output.

4.1 Text and ASCII output

Text files are useful for:

  • Inspecting numerical values.

  • Reviewing mode and frequency data.

  • Importing results into other programs.

  • Creating custom scripts or reports.

Typical columns may include:

  • Mode number.

  • Natural frequency.

  • Group name.

  • Energy percentage.

  • Total energy.

  • Response magnitude.

4.2 Excel output

Excel files are useful for:

  • Sorting and filtering results.

  • Creating custom plots.

  • Comparing groups or modes.

  • Reviewing effective mass and response tables.

  • Applying macros supplied with the toolkit.

The toolkit can generate worksheets containing:

  • Modal effective mass.

  • Cumulative effective mass.

  • Energy by mode and group.

  • Frequency-response data.

  • Stress and margin-of-safety data.

  • Response-node data.

Excel files have practical size limitations. Large datasets may exceed the supported file size, so summary or group-level data should be exported instead of all individual-element results.

4.3 XML output

XML output is used when the result dataset is too large for Excel. XML does not have the same practical file-size limitation and is suitable for very large result collections.

4.4 HTML output

HTML reports can contain:

  • Tables.

  • Plots.

  • Group summaries.

  • Frequency-response graphs.

  • Stress and margin-of-safety results.

HTML pages are useful for quickly reviewing and distributing analysis results.

4.5 Universal and binary output

Universal files and binary result files can be used for:

  • NX post-processing.

  • Contour visualization.

  • Function Navigator plots.

  • Further processing of displacement, velocity, acceleration, and stress data.

The toolkit can generate associated-function files for frequency-dependent results such as:

  • Acceleration versus frequency.

  • Power spectral density versus frequency.

  • Stress versus frequency.

  • Margin of safety versus frequency.


5. General Execution Workflow

A processor is normally executed as follows:

  1. Open or select the $op2$ file.

  2. Import or define groups.

  3. Select a processor.

  4. Enter the processor settings.

  5. Select output requests.

  6. Specify result files and formats.

  7. Write the definition file.

  8. Start the processor.

  9. Review the log file.

  10. Open the generated results in NX, Excel, HTML, or another supported viewer.

The toolkit creates a definition file on disk and launches the processor executable. The processor reads the definition file, processes the Nastran results, and writes the selected output.

5.1 Log files

Log files contain:

  • Run messages.

  • Warnings.

  • Error messages.

  • A summary of the settings used.

  • Information about generated files.

When a processor fails, the log file should be examined first. It is also useful when requesting technical support because it shows the processor’s interpretation of the settings.

5.2 Command-line execution

The core processor can be launched from the command line rather than through the graphical interface. A typical command includes:

  1. The input $op2$ file.

  2. The definition file.

  3. The project name.

  4. The processor identifier.

  5. The toolkit installation path or executable location.

Command-line execution is useful for:

  • Batch processing.

  • Running multiple cases.

  • Automating repeated analyses.

  • Submitting jobs without occupying the graphical interface.

  • Running analyses on Linux or Windows systems.


6. Troubleshooting and Required Nastran Requests

6.1 Failure to open an $op2$ file

If an $op2$ file cannot be opened, the Nastran solution should be checked first.

Important checks include:

  • Whether the Nastran run completed successfully.

  • Whether a fatal error occurred.

  • Whether the requested solution sequence was actually solved.

  • Whether the result file was created completely.

  • Whether the file format is supported.

6.2 Missing stress results

If the toolkit cannot find stress results, the stress output was probably not requested in the Nastran solution.

The required stress requests must be added to the relevant case-control or output-request section before solving. The toolkit cannot reconstruct stresses that were never written to the $op2$ file.

The same principle applies to:

  • Displacements.

  • Velocities.

  • Accelerations.

  • Element forces.

  • MPC forces.

  • Effective masses.

  • Strain energy.

  • Kinetic energy.

6.3 Required result data

The desired post-processing result must be requested during the original Nastran analysis. For example:

  • Stress processing requires stress output.

  • Force recovery requires element-force or MPC-force output.

  • Harmonic acceleration processing requires displacement or appropriate modal response data.

  • Energy processing requires the necessary energy data.

  • Modal assessment requires eigenvectors and effective-mass information.


Modal Analysis and Modal-Basis Quality

7. Modal Processor

A modal analysis represents the structure using its natural modes. Each mode has:

  • A natural frequency.

  • A mode shape.

  • A generalized mass.

  • A modal participation factor.

  • An effective mass in each direction.

The modal processor summarizes these properties and helps determine whether the selected modes adequately represent the structure.

7.1 Effective mass

Effective modal mass measures how strongly a mode participates in rigid-body motion in a particular direction.

For each mode, the toolkit can report effective mass in:

  • Translational XXX, YYY, and ZZZ directions.

  • Rotational directions.

  • Cumulative form across all retained modes.

A mode with high effective mass is strongly excited by base motion in the corresponding direction.

The cumulative effective mass is especially important in base-excitation analyses. The retained modes should capture a sufficiently large percentage of the total rigid-body mass in each excitation direction.

7.2 Modal truncation

Modal truncation occurs when not enough modes are included in the modal basis. Important higher-frequency modes may be omitted even though they contribute statically or dynamically to the response.

Truncation may cause:

  • Underpredicted off-resonance response.

  • Incomplete effective mass.

  • Inaccurate acceleration, displacement, or stress predictions.

  • Incorrect random-vibration RMS values.

  • Poor representation of local modes.

The modal basis should normally include all modes within the forcing-frequency range. For improved accuracy, modes extending to approximately two or three times the highest forcing frequency are often recommended.

7.3 Rigid-body mass coverage

For base excitation, the cumulative effective mass should approach the total rigid-body mass in every excitation direction.

If the cumulative effective mass is low, possible causes include:

  • Too few modes.

  • Missing rigid-body participation.

  • Insufficient modal basis.

  • Inappropriate constraints.

  • Modal truncation effects.

The toolkit reports the cumulative fractions so that the analyst can determine whether additional modes or residual-vector techniques are needed.

7.4 Modal participation and response screening

A useful screening approach is to identify modes that satisfy either of two conditions:

  • High effective mass.

  • High local response.

A local mode may have low effective mass but still produce a high stress or acceleration at a particular node or component. Therefore, effective mass alone is not sufficient for identifying all important modes.


Energy Analysis

8. Energy Processor

The energy processor evaluates how the structure participates in each mode. It is particularly useful for assemblies in which different components may respond differently.

The processor can calculate:

  • Kinetic energy.

  • Strain energy.

  • Energy by mode.

  • Energy by group.

  • Energy density for individual elements, when requested.

8.1 Kinetic energy

Modal kinetic energy is related to the mass distribution and modal velocity. Conceptually, it is obtained by combining the elemental mass matrices with the modal velocity vectors.

A simplified expression is:

Ek=12vTMvE_k = \frac{1}{2}\mathbf{v}^{T}\mathbf{M}\mathbf{v}Ek​=21​vTMv

where:

  • M\mathbf{M}M is the mass matrix.

  • v\mathbf{v}v is the modal velocity vector.

High kinetic energy in a group indicates that the group contains mass participating strongly in the motion.

8.2 Strain energy

Modal strain energy is related to the structural stiffness and modal displacement vectors.

A simplified expression is:

Es=12uTKuE_s = \frac{1}{2}\mathbf{u}^{T}\mathbf{K}\mathbf{u}Es​=21​uTKu

where:

  • K\mathbf{K}K is the stiffness matrix.

  • u\mathbf{u}u is the modal displacement vector.

High strain energy indicates that the component is deforming significantly in that mode.

8.3 Energy density

Nastran can also calculate strain-energy density by dividing the energy associated with an element by an appropriate element measure, such as volume or another elemental quantity.

Energy density helps identify localized regions that may be important even if the total group energy is relatively small.

8.4 Energy by group

For each mode, the processor can report:

  • Energy in each group.

  • Percentage of the total model energy.

  • Total energy represented by the selected groups.

If the groups partition the complete model without overlap, their energy percentages should sum to approximately 100%100\%100%.

If the groups do not cover the entire model, the selected-group total will be less than the total model energy.

8.5 Interpreting kinetic and strain energy

Kinetic and strain energy answer different questions:

  • Kinetic energy: Which components contain mass participating in the motion?

  • Strain energy: Which components are deforming or storing elastic energy?

A component can have:

  • High kinetic energy but low strain energy, meaning it moves substantially but remains relatively rigid.

  • Low kinetic energy but high strain energy, meaning it undergoes local deformation.

  • High values of both, indicating a major contributor to the overall dynamic response.

Energy plots can expose important behavior that may not be obvious from animation alone.


Harmonic Base-Excitation Analysis

9. Sign Processor

The sign processor evaluates the steady-state response to a deterministic, periodic base excitation.

Unlike random vibration, harmonic excitation has a defined frequency and amplitude. The response is calculated as a function of excitation frequency.

The processor is based on:

  • A normal-mode solution, usually Solution 103.

  • Modal superposition.

  • Rigid-body modes.

  • Modal damping.

  • Base-excitation input.

9.1 Harmonic response

For harmonic excitation, the response is represented using complex quantities. A general harmonic motion may be written as:

x(t)=Re⁡{Xejωt}x(t) = \operatorname{Re}\left\{X e^{j\omega t}\right\}x(t)=Re{Xejωt}

where:

  • XXX is the complex response amplitude.

  • ω\omegaω is the excitation circular frequency.

  • jjj is the imaginary unit.

The response includes both magnitude and phase. Depending on the selected output, the toolkit can report:

  • Real part.

  • Imaginary part.

  • Magnitude.

  • Phase.

  • Magnitude only.

9.2 Transfer-function formulation

The modal response depends on a transfer function. A simplified single-mode transfer function has the form:

H(ω)=1ωn2−ω2+j 2ζωnωH(\omega) = \frac{1} {\omega_n^2-\omega^2+j\,2\zeta\omega_n\omega}H(ω)=ωn2​−ω2+j2ζωn​ω1​

where:

  • ωn\omega_nωn​ is the natural circular frequency.

  • ω\omegaω is the excitation circular frequency.

  • ζ\zetaζ is the damping ratio.

The response becomes large near resonance, especially when damping is low.

9.3 Modal participation

The total response is formed by combining:

  • Rigid-body response.

  • Contributions from retained modes.

  • Modal participation factors.

  • Modal transfer functions.

  • Any residual-vector or residual-flexibility contribution.

A conceptual modal-superposition expression is:

x(ω)=∑r=1Nϕrqr(ω)+xresidual\mathbf{x}(\omega) = \sum_{r=1}^{N} \boldsymbol{\phi}_r q_r(\omega) + \mathbf{x}_{\text{residual}}x(ω)=∑r=1N​ϕr​qr​(ω)+xresidual​

where:

  • ϕr\boldsymbol{\phi}_rϕr​ is the mode shape for mode rrr.

  • qr(ω)q_r(\omega)qr​(ω) is the modal coordinate.

  • xresidual\mathbf{x}_{\text{residual}}xresidual​ accounts for omitted modal content when applicable.

9.4 Required Nastran data

A harmonic post-processing run may require:

  • Modal displacements.

  • Modal stresses.

  • Modal effective mass.

  • Element forces or MPC forces, if those quantities will be processed.

  • Appropriate constraints and base-excitation definitions.

If a result is not requested in the Nastran solution, the toolkit cannot produce it afterward.

9.5 Frequency sets

Frequency sets specify the excitation frequencies at which results are calculated.

Useful frequency points include:

  • Natural frequencies.

  • Frequencies between natural frequencies.

  • End points of the excitation range.

  • Breakpoints in the input spectrum.

  • Additional frequencies near sharp changes in the input.

A dense frequency set produces smoother plots and better captures resonance peaks.

The processor can use frequency ranges, mode ranges, or explicitly defined frequencies.

9.6 Absolute and relative response

The toolkit can calculate:

  • Absolute displacement, velocity, and acceleration.

  • Relative displacement, velocity, and acceleration.

Relative response is especially relevant to shaker testing, where the measured motion may be relative to the moving base.

9.7 Modal damping

Damping is specified using an amplification factor QQQ. The relationship between QQQ and critical damping ratio is:

Q=12ζQ = \frac{1}{2\zeta}Q=2ζ1​

Thus:

ζ=12Q\zeta = \frac{1}{2Q}ζ=2Q1​

Higher QQQ corresponds to lower damping and sharper resonance amplification.

The toolkit primarily uses modal damping entered through the processor settings. Material or spring-element damping may not be included in the same way.


10. Residual Vectors and Residual Flexibility

10.1 Purpose

Residual-vector methods improve the response prediction when the retained modal basis omits important higher-frequency modes.

The omitted modes may contribute significantly to the static or off-resonance response even if they are not dynamically resonant within the frequency range of interest.

10.2 Residual-vector method

The residual-vector method adds vectors representing the static response associated with omitted modal content.

The idea is to:

  1. Determine the total applied force.

  2. Subtract the contribution represented by the retained modes.

  3. Transform the remaining force through the stiffness matrix.

  4. Generate residual vectors.

  5. Add their contribution to the retained modal basis.

The residual vectors are constructed to be orthogonal to the retained modes with respect to the mass and stiffness matrices.

10.3 Residual flexibility

Residual flexibility is another approach to accounting for omitted modes. Rather than explicitly adding extra eigenvectors, it adds the missing static contribution directly to the response.

In simplified form:

xtotal=xdynamic+xstatic, omitted\mathbf{x}_{\text{total}} = \mathbf{x}_{\text{dynamic}} + \mathbf{x}_{\text{static, omitted}}xtotal​=xdynamic​+xstatic, omitted​

Residual flexibility is particularly useful when the excitation frequency is below the highest retained modal frequency but higher-frequency modes still contribute statically.

10.4 Effect on results

Without residual correction, a modal solution may underpredict off-resonance response. A direct-frequency solution does not suffer from the same modal truncation limitation because it solves the dynamic equations without relying on a truncated modal basis.

The difference between modal and direct solutions is often most visible away from resonance. Near a dominant resonance, both methods may produce similar peaks, while RMS or broadband quantities can still differ if omitted modes affect the valleys and off-resonance regions.


Random Vibration Analysis

11. Random Processor

The random processor calculates the structural response to statistically defined random base excitation.

Random vibration is described using a power spectral density, or PSD, rather than a single deterministic time history.

The processor is intended for stationary random processes, meaning that the statistical properties do not change with time.

11.1 Stationary random process

A process is stationary when quantities such as:

  • Mean.

  • Variance.

  • PSD.

  • Autocorrelation.

remain statistically consistent over time.

The analysis assumes a zero-mean random process. Adding a static offset changes the mean and is outside the assumptions of the standard random-vibration formulation.

11.2 Power spectral density

A PSD describes how the variance of an input is distributed over frequency.

For a response PSD Sx(f)S_x(f)Sx​(f), the variance is:

σx2=∫fmin⁡fmax⁡Sx(f) df\sigma_x^2 = \int_{f_{\min}}^{f_{\max}} S_x(f)\,dfσx2​=∫fmin​fmax​​Sx​(f)df

The root-mean-square response is:

xRMS=σx=∫fmin⁡fmax⁡Sx(f) dfx_{\mathrm{RMS}} = \sigma_x = \sqrt{ \int_{f_{\min}}^{f_{\max}} S_x(f)\,df }xRMS​=σx​=∫fmin​fmax​​Sx​(f)df​

For acceleration PSD, the units are typically acceleration squared per hertz, such as:

g2Hz\frac{g^2}{\text{Hz}}Hzg2​

or acceleration-units squared per hertz.

11.3 Response PSD

The response PSD is determined by multiplying the input PSD by the squared magnitude of the transfer function:

Sx(f)=∣H(f)∣2Sinput(f)S_x(f) = \left|H(f)\right|^2 S_{\text{input}}(f)Sx​(f)=∣H(f)∣2Sinput​(f)

For a modal system, the transfer function includes:

  • Modal participation.

  • Mode shape.

  • Natural frequency.

  • Damping.

  • Modal truncation corrections.

The toolkit integrates the response PSD over frequency using a reduced modal basis, which makes it substantially faster than integrating every degree of freedom independently.

11.4 Gaussian response statistics

If the excitation is Gaussian and the system is linear, the response is also Gaussian for linear response quantities such as displacement or acceleration.

For a zero-mean Gaussian variable:

  • Approximately 68.27%68.27\%68.27% of values lie within ±1σ\pm1\sigma±1σ.

  • Approximately 95.45%95.45\%95.45% lie within ±2σ\pm2\sigma±2σ.

  • Approximately 99.73%99.73\%99.73% lie within ±3σ\pm3\sigma±3σ.

A response specified at 3σ3\sigma3σ is therefore associated with a confidence level of approximately 99.73%99.73\%99.73% for a Gaussian response.

The toolkit can accept either:

  • A confidence level.

  • A peak-to-RMS ratio.

It then calculates the corresponding peak response.

11.5 Non-Gaussian derived quantities

Quantities such as von Mises stress are nonlinear combinations of stress components. They do not necessarily follow a Gaussian distribution even when each individual stress component is Gaussian.

For example, in a two-dimensional stress state:

σvm=σx2−σxσy+σy2+3τxy2\sigma_{\mathrm{vm}} = \sqrt{ \sigma_x^2 -\sigma_x\sigma_y +\sigma_y^2 +3\tau_{xy}^2 }σvm​=σx2​−σx​σy​+σy2​+3τxy2​​

Because von Mises stress is always nonnegative and depends quadratically on the stress components, multiplying RMS von Mises stress by a conventional factor such as 333 may be inaccurate.


12. Random-Vibration Stress and Failure Metrics

The random processor can estimate:

  • Peak von Mises stress.

  • Stress distributions.

  • Failure indices.

  • Strength ratios.

  • Margins of safety.

  • Composite failure metrics.

  • Element and ply-level results.

12.1 Monte Carlo approach

A Monte Carlo procedure generates many random samples of the stress components, evaluates the nonlinear stress measure for each sample, and sorts the results.

For a selected confidence level, the corresponding value is extracted from the ordered samples.

This method is accurate but computationally expensive, particularly for large models.

12.2 Alternative approximations

The toolkit also supports faster methods based on transformations of the stress state.

One approach transforms the von Mises stress into several independent Gaussian variables and evaluates the probability that the resulting equivalent stress exceeds a specified value.

The methods have different characteristics:

  • Monte Carlo

    • Highly accurate.

    • Computationally expensive.

    • Useful for validation or difficult distributions.

  • Analytical or semi-analytical method

    • Faster than Monte Carlo.

    • Suitable for many practical cases.

    • Based on probability-integral approximations.

  • Fast approximation

    • Much faster.

    • Intended primarily for high confidence levels, such as approximately 3σ3\sigma3σ.

    • May be slightly conservative or slightly nonconservative depending on the stress state.

For low confidence levels, such as approximately 1σ1\sigma1σ, the fast approximation may be inappropriate. A more accurate method should be selected.

12.3 Conservatism and approximation error

The approximation error depends on the stress tensor and the response distribution. It is not necessarily determined only by model size or material type.

If a predicted margin of safety is close to the design limit, the analyst should:

  • Use a more accurate stress-distribution method.

  • Compare the approximate and exact methods.

  • Consider a small engineering correction only after validating the trend.

  • Avoid redesign decisions based solely on a borderline approximation.


13. Random-Processor Settings

The random processor typically requires:

  • Base-excitation PSD.

  • Frequency range.

  • Modal damping.

  • Retained modes or mode-frequency ranges.

  • Absolute or relative response selection.

  • Modal truncation correction.

  • Confidence level or peak-to-RMS ratio.

  • Output requests.

  • Stress cases.

  • Composite failure theory and allowables, when applicable.

13.1 PSD input

The PSD can be entered as frequency–PSD pairs:

  • Frequency.

  • Power spectral density.

The input may be read from a text file or entered directly.

If the PSD is expressed in units of g2/Hzg^2/\text{Hz}g2/Hz but the finite-element model uses acceleration units such as mm/s2\text{mm}/\text{s}^2mm/s2, a scale factor is required.

For example:

1g≈386.1 in/s21g \approx 386.1\ \text{in}/\text{s}^21g≈386.1 in/s2

or approximately:

1g≈9810 mm/s21g \approx 9810\ \text{mm}/\text{s}^21g≈9810 mm/s2

The analysis must use a consistent unit system.

13.2 Integration limits

The user can define lower and upper frequency limits for PSD integration. The response is integrated only within the specified interval.

This is useful when:

  • The input PSD is valid only over a particular frequency band.

  • The analyst wants to isolate a portion of the spectrum.

  • Different frequency bands are being studied separately.

13.3 Multiple axes and subcases

The processor can run multiple excitation directions or subcases in one analysis. However, if different damping values are required for the different axes, the axes may need to be processed separately.

The combination of excitation direction and input spectrum determines the individual subcase.

13.4 Output requests

All output requests must be explicitly enabled. Depending on the desired result, the input solution may need to contain:

  • Displacements.

  • Velocities.

  • Accelerations.

  • Stresses.

  • Element forces.

  • MPC forces.

  • Strains.

  • Stress and strain eigenvectors for composite failure calculations.

Simply requesting a general stress output is not always sufficient to generate the nonlinear von Mises or composite failure results. Specific stress cases may need to be defined in the toolkit.


Stress, Margins of Safety, and Failure Analysis

14. Harmonic Stress Processing

For harmonic results, stress components are complex. The toolkit can calculate the phase-consistent von Mises stress.

The processor may use an analytical method to determine the phase relationship at which the combined von Mises stress is maximum.

This is important because independently maximizing each stress component does not necessarily produce the maximum combined von Mises stress.

14.1 Margin of safety

A basic margin-of-safety expression is:

MS=SallowableFs σapplied−1MS = \frac{S_{\text{allowable}}} {F_s\,\sigma_{\text{applied}}} -1MS=Fs​σapplied​Sallowable​​−1

where:

  • SallowableS_{\text{allowable}}Sallowable​ is the allowable stress.

  • FsF_sFs​ is the required safety factor.

  • σapplied\sigma_{\text{applied}}σapplied​ is the calculated stress.

A positive margin indicates that the allowable exceeds the factored applied stress. A negative margin indicates that the applied stress exceeds the allowable requirement.

The exact allowable and safety-factor conventions depend on the design standard and analysis setup.

14.2 Yield and ultimate allowables

Separate stress cases can be created for:

  • Yield allowable.

  • Ultimate allowable.

  • Different safety factors.

  • Different materials.

  • Different groups or components.

The analyst must ensure that the selected allowable corresponds to the correct material and failure criterion.

14.3 Composite failure metrics

For composite structures, the toolkit can calculate:

  • Failure indices.

  • Strength ratios.

  • Margins of safety.

  • Ply-level results.

  • Failure metrics for two-dimensional and three-dimensional elements.

These calculations require appropriate stress and strain information, including stress or strain eigenvectors when needed by the selected failure theory.

The exact failure equation may include linear and quadratic terms in the stress components, making the distribution more complicated than a simple von Mises calculation.


15. Results in NX and Function Navigator

The toolkit can export results for visualization in NX.

Typical results include:

  • Modal shapes.

  • Accelerations.

  • Displacements.

  • Velocities.

  • Power spectral densities.

  • Harmonic stresses.

  • Random-vibration stresses.

  • Margins of safety.

  • Composite failure metrics.

The NX Function Navigator can display frequency-dependent functions such as:

  • Response amplitude versus frequency.

  • Stress versus frequency.

  • PSD versus frequency.

  • Envelopes of several response curves.

15.1 Contour results

Contour results can be written to universal or binary files and then loaded into NX for spatial visualization.

For random analyses, contour data generally represent RMS or confidence-level peak results rather than an instantaneous time-domain value.

A contour labeled as a peak result may therefore be based on the selected statistical confidence level.

15.2 Envelope plots

Envelope operations can combine multiple response curves and display the maximum response at each frequency.

This is useful when:

  • Several load cases are being compared.

  • Multiple nodes or groups are being assessed.

  • The maximum of several directional responses is required.

  • A single design envelope is needed.


Units and Consistency

16. Unit Systems

The toolkit itself is essentially unitless. The analyst must provide a consistent unit system throughout:

  • Geometry.

  • Mass.

  • Stiffness.

  • Density.

  • Force.

  • Stress.

  • Acceleration.

  • Frequency.

  • PSD.

Examples of consistent systems include:

  • Inches, pounds-force, seconds.

  • Millimeters, newtons, seconds.

  • Meters, kilograms, seconds.

The gravitational acceleration factor must match the selected unit system. For example:

1g≈386.1 in/s21g \approx 386.1\ \text{in}/\text{s}^21g≈386.1 in/s2

and:

1g≈9.81 m/s21g \approx 9.81\ \text{m}/\text{s}^21g≈9.81 m/s2

The toolkit may display some values in solver-consistent units even when the analyst selects a scaling factor for plots or reports. Therefore, the reported units should always be checked before interpreting or publishing results.


Recommended Analysis Practice

17. Reliable Workflow for Dynamic Analysis

A reliable dynamic-analysis workflow should include the following steps:

  1. Define the physical model carefully.

    • Check mass, stiffness, constraints, interfaces, and material properties.

  2. Select a suitable solution sequence.

    • Use a normal-mode solution for modal superposition.

    • Use harmonic or random post-processors for base excitation.

  3. Request all required Nastran results.

    • Do not assume the toolkit can recover results that were not written to the $op2$ file.

  4. Verify the modal basis.

    • Check natural frequencies.

    • Check effective mass.

    • Check cumulative mass in every excitation direction.

    • Consider residual vectors or residual flexibility if necessary.

  5. Define groups using elements.

    • Ensure that exported groups contain individual finite elements.

  6. Use appropriate frequency points.

    • Include natural frequencies, spectrum breakpoints, and intermediate points.

  7. Specify damping consistently.

    • Confirm the relationship between damping ratio and amplification factor.

  8. Check units.

    • Confirm acceleration scaling, PSD units, stress units, and frequency units.

  9. Review logs and warnings.

    • A successful executable run does not necessarily guarantee a physically complete result.

  10. Validate important results.

    • Compare modal, direct, or alternative-method results where practical.

      • Compare approximate and exact stress methods for borderline cases.

  11. Inspect both global and local behavior.

    • Effective mass identifies globally important modes.

      • Energy and local-response processing identify component-level behavior.

  12. Use appropriate statistical interpretation.

    • Do not automatically multiply nonlinear random stress results by a Gaussian peak factor.


18. Key Relationships to Remember

Effective mass identifies how strongly a mode participates in base motion, but it does not identify every locally important mode.

Kinetic energy indicates where mass participates in motion, while strain energy indicates where elastic deformation is concentrated.

Modal truncation can cause underprediction away from resonance because omitted modes still contribute statically.

Residual vectors and residual flexibility improve modal predictions by representing the contribution of omitted modes.

Random vibration is described statistically through PSD, variance, RMS, and confidence-level peaks rather than a single deterministic response.

Von Mises stress and composite failure metrics are nonlinear, so their random distributions are not necessarily Gaussian even when the underlying stress components are Gaussian.

The Structural Analysis Toolkit is most effective when the Nastran solution contains the correct modal basis and output requests, the groups contain actual elements, the unit system is consistent, and the selected statistical or modal approximation is appropriate for the required confidence and accuracy.

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent