Polyphase AC Systems
- 14Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
What is the primary advantage of using polyphase systems over single-phase systems for generating rotating magnetic fields?
What is the primary advantage of using polyphase systems over single-phase systems for generating rotating magnetic fields?
14 questions
- 1
What is the primary advantage of using polyphase systems over single-phase systems for generating rotating magnetic fields?
- A
Polyphase systems require fewer coils than single-phase systems.
- B
Polyphase systems can generate a pulsating magnetic field.
- C
Polyphase systems eliminate the need for a stator.
- D
Polyphase systems can generate a rotating magnetic field with constant magnitude.
Correct answer
DPolyphase systems can generate a rotating magnetic field with constant magnitude.
Explanation
By using spatially and time orthogonal signals, polyphase systems create a rotating magnetic field of constant magnitude, which is essential for AC machines. Single-phase systems can only produce a pulsating field.
- A
- 2
Who is credited with making the rotating magnetic field practical for AC machines?
- A
George Westinghouse
- B
Michael Faraday
- C
Thomas Edison
- D
Nikola Tesla
Correct answer
DNikola Tesla
Explanation
Nikola Tesla first made the rotating magnetic field practical and used it for AC machines, initially with two-phase systems.
- A
- 3
In a two-phase system with perpendicular coils driven by Bx=B0cos(ωt) and By=B0sin(ωt), what is the net magnitude of the magnetic flux density?
- A
2B0
- B
B0
- C
2B0
- D
0
Correct answer
BB0
Explanation
The magnitude is ∣B∣=B02cos2(ωt)+B02sin2(ωt)=B0, which is constant.
- A
- 4
What is the phase shift between the three-phase voltages Va(t)=Vssin(ωt), Vb(t), and Vc(t) in a balanced three-phase system?
- A
60 degrees
- B
180 degrees
- C
90 degrees
- D
120 degrees
Correct answer
D120 degrees
Explanation
The voltages are shifted by 120∘ (or 2π/3 radians) from each other, as given in the lecture.
- A
- 5
Which of the following correctly represents the phasor for Va(t)=Vssin(ωt)?
- A
V^a=Vsejπ/2
- B
V^a=Vse−jπ/2
- C
V^a=Vse−jπ
- D
V^a=Vsej0
Correct answer
BV^a=Vse−jπ/2
Explanation
Since sin(ωt)=cos(ωt−π/2), the phasor is Vse−jπ/2.
- A
- 6
What is the line-to-line voltage Vab in a balanced Y-connected three-phase system if the phase voltage magnitude is Vs?
- A
2Vs
- B
3Vs
- C
2Vs
- D
Vs
Correct answer
B3Vs
Explanation
The phasor difference V^ab=V^a−V^b has magnitude 3Vs and leads Va by 30∘.
- A
- 7
In a delta connection, how many wires are typically used to connect the source or load to the rest of the system?
- A
Six wires (each phase pair)
- B
Two wires (single phase)
- C
Four wires (three phases plus neutral)
- D
Three wires (no neutral)
Correct answer
DThree wires (no neutral)
Explanation
A delta connection has no neutral point; only three wires are brought out for the phases.
- A
- 8
What happens if a three-phase source is connected in delta and the phase voltages are unbalanced?
- A
The neutral wire carries current.
- B
Line voltages become zero.
- C
The system becomes single-phase.
- D
Circulating currents flow in the delta loop.
Correct answer
DCirculating currents flow in the delta loop.
Explanation
Imbalances in a delta-connected source cause circulating currents around the delta loop, which is why generators are usually not connected in delta.
- A
- 9
Which of the following is NOT an advantage of three-phase systems over single-phase systems?
- A
Reduced conductor material for transmission
- B
Lower voltage magnitudes
- C
Constant power transfer
- D
Ability to generate a rotating magnetic field
Correct answer
BLower voltage magnitudes
Explanation
Three-phase systems do not inherently have lower voltage magnitudes; in fact, line-to-line voltages are higher. The advantages include constant power, reduced conductor material, and rotating magnetic fields.
- A
- 10
In a balanced three-phase system, the sum of the instantaneous powers of three identical resistive loads connected to each phase is:
- A
Pulsating at twice the line frequency
- B
Constant (purely DC)
- C
Pulsating at the line frequency
- D
Zero
Correct answer
BConstant (purely DC)
Explanation
The three phase-shifted powers add to a constant DC value because the cos(2ωt) terms cancel.
- A
- 11
How does three-phase power transmission require less conductor material compared to single-phase for the same power loss?
- A
Three-phase uses fewer conductors per phase.
- B
Three-phase has lower resistance per conductor.
- C
Three-phase uses higher voltages, reducing current.
- D
The neutral wire is not needed because the phase currents sum to zero.
Correct answer
DThe neutral wire is not needed because the phase currents sum to zero.
Explanation
In a balanced three-phase system, the return currents sum to zero in the neutral, so no neutral conductor is needed, saving material compared to single-phase which requires two conductors.
- A
- 12
In a three-phase system with a delta-connected load, which harmonics are canceled in the line currents if the load draws balanced but distorted currents?
- A
All even harmonics
- B
All odd harmonics
- C
All harmonics above the 7th
- D
Triple-n harmonics (multiples of 3)
Correct answer
DTriple-n harmonics (multiples of 3)
Explanation
Due to the 120-degree phase shift, triple-n harmonics (3rd, 6th, 9th, etc.) cancel in the line currents because they are in phase in the phase currents.
- A
- 13
Why is three-phase preferred over two-phase in practice?
- A
Three-phase has lower voltage than two-phase.
- B
Three-phase cancels triple-n harmonics and allows more efficient conductor use, while two-phase does not offer harmonic cancellation.
- C
Three-phase provides constant power transfer and rotating fields, while two-phase does not.
- D
Three-phase requires fewer conductors than two-phase.
Correct answer
BThree-phase cancels triple-n harmonics and allows more efficient conductor use, while two-phase does not offer harmonic cancellation.
Explanation
Both two-phase and three-phase provide constant power and rotating fields, but three-phase additionally cancels triple-n harmonics and reduces conductor material more effectively.
- A
- 14
What is the consequence of reversing the phase order in a three-phase motor?
- A
The motor rotates faster.
- B
The motor stops.
- C
The motor rotates in the opposite direction.
- D
The motor draws more current.
Correct answer
CThe motor rotates in the opposite direction.
Explanation
Reversing the phase order (e.g., swapping two phases) reverses the direction of the rotating magnetic field, causing the motor to spin in the opposite direction.
- A