- 1A reinforced concrete column is a vertical structural element that primarily carries_____.
Hint
Think of the main force acting along the column’s length.
Answer
axial load
Explanation
A reinforced concrete column is a vertical structural element whose primary role is to carry axial load; it may also carry bending moments.
- 2Besides strength, a properly designed column contributes to a structure’s stability and_____.
Hint
Consider how well the structure should perform over time.
Answer
durability
Explanation
The content identifies strength, stability, and durability as key outcomes of proper column design.
- 3The Indian Standard for general concrete structure design referenced in the content is_____.
Hint
It is the principal code named for concrete structures.
Answer
IS 456 to 2000
Explanation
The content states that reinforced concrete column design follows IS 456 to 2000.
- 4The design strength of a reinforced concrete column is based on the_____method.
Hint
This design approach checks whether structural limits are satisfied.
Answer
Limit State
Explanation
The content says column design strength is based on the Limit State method in IS 456.
- 5In a reinforced concrete column, concrete mainly resists compression, while steel reinforcement resists_____as well as compression.
Hint
This is the type of force that concrete handles less effectively than reinforcing steel.
Answer
tension
Explanation
Concrete resists compression, while steel reinforcement can resist both tension and compression.
- 6A column’s slenderness ratio compares its effective length with its_____.
Hint
Use the smaller cross-sectional dimension in this comparison.
Answer
least lateral dimension
Explanation
The slenderness ratio is defined using the column’s effective length and least lateral dimension.
- 7A column with slenderness ratio less than or equal to 12 is classified as a_____column.
Hint
This type is contrasted with a slender column.
Answer
short
Explanation
The content classifies columns with slenderness ratio less than or equal to 12 as short columns.
- 8A short column is described as failing primarily by_____.
Hint
This failure mode occurs when compressive strength is exceeded.
Answer
crushing
Explanation
The content associates short-column failure with crushing.
- 9A column with slenderness ratio greater than 12 is classified as a_____column.
Hint
This type is more affected by slenderness than a short column.
Answer
long
Explanation
The content classifies columns with slenderness ratio greater than 12 as long or slender columns.
- 10The failure mode associated with a long slender column is_____.
Hint
This instability can occur in a slender member under compression.
Answer
buckling
Explanation
Long slender columns are described as failing by buckling.
- 11A column carrying compression without bending is an_____column.
Hint
Its load acts along the column axis and produces no bending in this classification.
Answer
axially load
Explanation
The content describes an axially loaded column as carrying pure compression without bending.
- 12A column with a load and a moment about one axis is subject to_____bending.
Hint
The word indicates that bending occurs about one axis.
Answer
uniaxial
Explanation
The content classifies a column with a moment about one axis as a uniaxial bending column.
- 13A column with moments about both axes is subject to_____bending.
Hint
The word indicates that bending occurs about two axes.
Answer
biaxial
Explanation
A biaxial bending column carries load with moments about both axes.
- 14Additional guidelines named for column design include SP 16 design aids and_____for earthquake-resistant design.
Hint
This standard is also referenced for earthquake forces.
Answer
IS 1893
Explanation
The content names SP 16 design aids and IS 1893 earthquake-resistant design guidance alongside IS 456.
- 15The factored axial load is calculated using a load factor of_____times the sum of dead load and live load.
Hint
This is the partial safety factor given for the stated load calculation.
Answer
1.5
Explanation
The content gives the factored axial load as 1.5 times the combined dead load and live load.
- 16In the load notation used in the content, DL stands for_____.
Hint
It refers to the permanent weight carried by the structure.
Answer
dead load
Explanation
DL is defined as dead load in the stated factored-load calculation.
- 17In the load notation used in the content, LL stands for_____.
Hint
It refers to imposed loads that can vary with use.
Answer
live load
Explanation
LL is defined as live load in the stated factored-load calculation.
- 18For buildings in seismic areas, earthquake forces should be included using loads from_____.
Hint
This is the standard identified for earthquake forces.
Answer
IS 1893
Explanation
The content says loads from IS 1893 must be included when designing for seismic areas.
- 19The initial column dimensions should be chosen to satisfy architectural constraints and_____.
Hint
The dimensions must accommodate the forces the column is expected to carry.
Answer
load requirements
Explanation
The content says column size is selected based on both architectural constraints and load requirements.
- 20The stated minimum column width for normal loads is_____mm to help prevent slenderness effects.
Hint
This is the minimum width specified in the design steps.
Answer
230
Explanation
The content gives a minimum width of 230 mm for normal loads to prevent slenderness effects.
- 21An initial estimate of concrete area is made by relating the axial load to the concrete’s_____strength.
Hint
This is the strength of concrete used to resist column loading.
Answer
compressive
Explanation
The initial area estimate is based on the applied axial load and the characteristic compressive strength of concrete.
- 22The required longitudinal steel area is calculated using an axial capacity expression that combines concrete contribution with_____contribution.
Hint
The second contribution depends on the reinforcement’s yield strength and area.
Answer
steel
Explanation
The stated axial capacity expression includes contributions from concrete and reinforcing steel.
- 23The minimum longitudinal reinforcement specified is_____of the gross cross-sectional area.
Hint
This is the lower percentage limit given for column steel.
Answer
0.8%
Explanation
The content gives a minimum reinforcement limit of 0.8% of the gross cross-section.
- 24The maximum longitudinal reinforcement specified is_____of the gross cross-sectional area.
Hint
This is the upper percentage limit given for column steel.
Answer
6%
Explanation
The content gives a maximum reinforcement limit of 6% of the gross cross-section.
- 25For a slender column, the additional moment caused by buckling is associated with_____effects.
Hint
This effect occurs when an axial force acts through a laterally displaced column.
Answer
P Delta
Explanation
The content identifies the extra moment in slender columns as a consequence of P Delta buckling effects.
- 26For long columns, the content recommends using_____to check the interaction of axial load and moment.
Hint
These design aids relate combined loading to section capacity.
Answer
interaction curves
Explanation
The content recommends interaction curves from SP 16 for long-column design checks.
- 27For rectangular column sections, the stated minimum number of longitudinal bars is_____.
Hint
This is the minimum count given for a rectangular section.
Answer
four
Explanation
The content states that rectangular sections require a minimum of four longitudinal bars.
- 28For circular column sections, the stated minimum number of longitudinal bars is_____.
Hint
The required count is greater than the stated minimum for rectangular sections.
Answer
six
Explanation
The content states that circular sections require a minimum of six longitudinal bars.
- 29The stated minimum diameter for longitudinal bars in a circular column is_____mm.
Hint
This is the minimum bar diameter specified for circular sections.
Answer
12
Explanation
The content gives a minimum longitudinal bar diameter of 12 mm for circular columns.
- 30Lateral ties prevent buckling of the_____bars.
Hint
These are the main bars running along the column’s length.
Answer
longitudinal
Explanation
The content says transverse lateral ties prevent buckling of the longitudinal reinforcement bars.
- 31The stated maximum lateral tie spacing is the lesser of 16 times the bar diameter and_____mm.
Hint
Choose the smaller of the two stated spacing limits.
Answer
300
Explanation
The content specifies tie spacing no greater than 16 times the bar diameter or 300 mm, whichever is lesser.
- 32The stated minimum diameter for lateral ties is_____mm.
Hint
This is the minimum transverse reinforcement diameter given in the design steps.
Answer
6
Explanation
The content states that the minimum lateral tie diameter is 6 mm.
- 33For normal exposure conditions, the stated minimum clear cover to reinforcement is_____mm.
Hint
This cover helps protect the reinforcement and is also mentioned for fire resistance.
Answer
40
Explanation
The content specifies at least 40 mm of cover for normal exposure conditions.
- 34In coastal environments, corrosion protection may require_____cover than in ordinary conditions.
Hint
The reinforcement needs more protection in a more corrosive environment.
Answer
higher
Explanation
The content recommends using higher cover in coastal environments to protect against corrosion.
- 35The seismic design example is for a G+5 residential building in seismic_____in India.
Hint
The example identifies this as a high seismic zone.
Answer
Zone 4
Explanation
The example concerns a G+5 residential building located in Zone 4, described as a high seismic zone.
- 36The seismic design example uses IS 456 for general column design and_____for ductile detailing.
Hint
This standard is specifically identified for seismic-resistant detailing.
Answer
IS 13920 to 2016
Explanation
The content pairs IS 456 general design requirements with IS 13920 to 2016 ductile detailing requirements.
- 37The seismic example gives the column cross-section as_____mm by 600 mm.
Hint
The example uses a rectangular column with this smaller dimension.
Answer
400
Explanation
The seismic example uses a 400 mm by 600 mm column section.
- 38The concrete grade used in the seismic design example is_____.
Hint
This grade is paired with Fe 500 steel in the example.
Answer
M30
Explanation
The example specifies M30 concrete and Fe 500 steel.
- 39The steel grade used in the seismic design example is_____.
Hint
It is the reinforcement grade paired with M30 concrete.
Answer
Fe 500
Explanation
The example specifies Fe 500 reinforcement steel.
- 40Using the example’s effective length of 3.5 m and least lateral dimension of 400 mm, the slenderness ratio is_____.
Hint
Express the effective length and least lateral dimension in the same units before dividing.
Answer
8.75
Explanation
The ratio is 3500 mm divided by 400 mm, which equals 8.75; this is below 12, so the example column is short.
- 41Because the example column’s slenderness ratio is less than 12, it is treated as a_____column.
Hint
This classification means buckling effects are not significant in the example.
Answer
short
Explanation
The example identifies the column as short because its slenderness ratio is less than 12.
- 42For the seismic example, the concrete area is found by multiplying the two section dimensions, giving_____square millimetres.
Hint
Multiply 400 mm by 600 mm.
Answer
240,000
Explanation
The concrete cross-sectional area is 400 mm times 600 mm, or 240,000 square millimetres.
- 43The seismic example’s final longitudinal reinforcement arrangement uses_____bars of 25 mm diameter.
Hint
This is the increased bar count selected after the capacity checks.
Answer
12
Explanation
After checking axial and moment capacity, the example selects 12 bars of 25 mm diameter.
- 44The seismic example specifies lateral ties with a diameter of_____mm.
Hint
This tie size is larger than the stated minimum tie diameter.
Answer
8
Explanation
The example uses 8 mm diameter lateral ties.
- 45Outside the plastic hinge zones, the example specifies lateral ties at_____mm centre-to-centre.
Hint
This spacing is tightened further within the plastic hinge zones.
Answer
150
Explanation
The example specifies 8 mm ties at 150 mm centre-to-centre outside the plastic hinge zones.
- 46Within the first and last 1.5 m plastic hinge zones, the example reduces tie spacing to_____mm centre-to-centre.
Hint
Closer tie spacing improves confinement where inelastic deformation is expected.
Answer
100
Explanation
The example specifies 100 mm centre-to-centre tie spacing in the first and last 1.5 m plastic hinge zones.
- 47The seismic ductility check limits the axial load ratio to a value less than or equal to_____.
Hint
This is the maximum ratio stated in the content.
Answer
0.5
Explanation
The content states that the axial load ratio must be less than or equal to 0.5.
- 48Lap splices are not allowed in the_____zones of the column.
Hint
These are the regions where substantial inelastic deformation may occur during an earthquake.
Answer
plastic hinge
Explanation
The seismic detailing guidance says lap splices are not allowed in plastic hinge zones.
- 49Where lap splices are used, they should be staggered and confined with_____spaced ties.
Hint
The ties need to provide enhanced confinement around the splice region.
Answer
closely
Explanation
The content says lap splices should be staggered and confined with closely spaced ties.