Shock Waves in Compressible Flow
Normal Shock Waves and Compressible Nozzle Flow
Shock waves: definition and behavior
A shock wave is an extremely thin, irreversible discontinuity that can occur in a supersonic flow. Across it, flow properties change abruptly rather than gradually. Shock waves may occur inside ducts and nozzles or outside around objects such as aircraft. They may be stationary, as in a duct, or move with an object or flow.
A shock is extremely thin—on the order of 10−5 inches—so it is treated as a discontinuity in ordinary flow analysis. Despite its small thickness, it produces substantial changes in pressure, temperature, density, velocity, and Mach number.
Upstream refers to the flow approaching the shock.
Downstream refers to the flow after it has crossed the shock.
A normal shock is perpendicular to the incoming flow velocity.
An oblique shock is inclined to the incoming flow. Oblique shocks are not treated in detail here.
A shock requires supersonic upstream flow: M1>1. A shock cannot form in a subsonic flow. At exactly M1=1, the normal-shock relations approach the limiting case of a shock with no finite property change.
The central physical signature of a normal shock is that the flow changes from supersonic upstream to subsonic downstream, while entropy increases.
Governing equations across a normal shock
Consider a steady shock in a constant-area duct. Let station 1 be immediately upstream and station 2 immediately downstream. Because the shock is so thin, the duct area is effectively the same on both sides.
Conservation of mass
For steady one-dimensional flow,
Since the area is unchanged,
The mass flow rate is the same at both stations.
Conservation of momentum
In the flow direction, the pressure forces and momentum fluxes balance:
Here, m˙ is the same on both sides because mass is conserved. The pressure and velocity can change substantially across the shock.
Conservation of energy
For an adiabatic shock with no shaft work, the steady-flow energy equation is
The sum of static enthalpy and kinetic energy per unit mass remains constant. Because velocity falls across a normal shock, static enthalpy and static temperature rise.
Perfect-gas relations
For a perfect gas,
and, when the specific heat at constant pressure is constant,
Together, mass conservation, momentum conservation, energy conservation, the equation of state, and the enthalpy relation provide five equations for the five downstream quantities p2, ρ2, T2, V2, and h2, given the upstream state.
Normal-shock relations
The upstream Mach number M1 is the key parameter used to calculate changes across a normal shock. The relations below are written for a calorically perfect gas with specific-heat ratio γ. For air with γ=1.4, they simplify to the numerical forms shown.
Static-pressure ratio
For a general γ,
For γ=1.4,
Static pressure increases across a normal shock.
Density ratio
For a general γ,
For γ=1.4,
Density increases across the shock.
Static-temperature ratio
Using the perfect-gas relation,
For γ=1.4,
Static temperature increases across the shock.
Velocity ratio
Mass conservation gives
Thus, because density increases, velocity decreases.
Downstream Mach number
For a general γ,
For γ=1.4,
For a genuine normal shock with M1>1, the downstream Mach number is subsonic: M2<1. As M1 increases, M2 generally becomes smaller.
Stagnation properties
Stagnation quantities are the properties a flow would have if it were brought to rest under the specified idealized process.
Stagnation temperature T0 is unchanged across an adiabatic normal shock:
T02=T01.This follows from conservation of total enthalpy for a perfect gas.
Stagnation pressure p0 decreases across the shock:
p02<p01.The shock is irreversible, so total pressure is not conserved.
Entropy increases:
s2>s1.This is a defining consequence of irreversibility.
The flow’s total enthalpy is conserved, but its stagnation pressure falls. The pressure loss reflects the irreversible loss of the flow’s ability to produce useful mechanical work; it does not mean that total energy disappears.
Summary of property changes
For a normal shock with supersonic upstream flow:
Mach number: decreases; the downstream flow is subsonic.
Static pressure: increases.
Static temperature: increases.
Density: increases.
Velocity: decreases.
Stagnation pressure: decreases.
Stagnation temperature: unchanged.
Entropy: increases.
Static enthalpy: increases as static temperature rises.
Entropy and choosing the physical solution
When the conservation equations are solved, the velocity relation can produce two mathematical roots because velocity appears squared in the energy equation. Only one root represents a physically possible shock.
The correct solution is the one for which entropy increases. A shock is irreversible, and the second law requires
The root that predicts a decrease in entropy is rejected. Friction and molecular interactions within the very thin shock region are associated with this irreversible entropy increase.
Normal-shock example
Suppose air approaches a stationary normal shock with
The upstream temperature of 500 ∘R corresponds to 40∘F. For air in the stated British gravitational units, take γ=1.4 and R=1716 ft⋅lbf/(slug⋅∘R).
1. Find the upstream Mach number
The speed of sound is
Using the absolute temperature,
Therefore,
Since M1>1, a normal shock is possible.
2. Find the downstream static properties
For M1=2 and γ=1.4, the normal-shock ratios are approximately
Thus,
and
The velocity ratio is
so
The downstream Mach number is approximately
confirming that the flow becomes subsonic.
3. Find stagnation conditions
The upstream stagnation temperature is approximately 900 ∘R. It is unchanged across the shock:
For this upstream Mach number, the stagnation-pressure ratio is approximately
With p01≈78.1 psia,
The stagnation pressure falls even though the static pressure rises from 10 to 45 psia.
4. Find density
Density can be found from the perfect-gas relation using absolute pressure and temperature. In British gravitational units, pressure must be converted to pounds per square foot:
This is consistent with a density ratio of approximately 2.667 relative to the upstream density.
Tables for compressible-flow calculations
Two tables support calculations involving shocks and isentropic flow. The table choice depends on whether the flow crosses a shock.
Isentropic-flow table
The isentropic table (referred to in the lecture as Table B1) gives quantities such as:
Mach number M.
Static-to-stagnation pressure ratio p/p0.
Static-to-stagnation density ratio ρ/ρ0.
Static-to-stagnation temperature ratio T/T0.
Area ratio A/A∗.
Here, A∗ is the area associated with sonic flow, where M=1, for the relevant isentropic flow region. Isentropic relations apply in flow regions where there is no shock and other irreversibilities are neglected.
Normal-shock table
The normal-shock table (Table B2 in the lecture) is indexed by upstream Mach number and gives quantities such as:
Downstream Mach number M2.
Static-pressure ratio p2/p1.
Density ratio ρ2/ρ1.
Static-temperature ratio T2/T1.
Stagnation-pressure ratio p02/p01.
Sonic-area ratio A2∗/A1∗.
The stagnation-temperature ratio is not needed as a separate column because
The shock-table values demonstrate the trends: at M1=2, M2≈0.5774; at M1=3, M2≈0.4752. The downstream flow is subsonic and becomes slower in Mach-number terms as upstream Mach number rises.
Selecting a table
Use isentropic relations in a region with no shock.
Use normal-shock relations or the shock table to cross a normal shock.
If the flow has isentropic regions both before and after a shock, use the isentropic table for each region and the shock table at the discontinuity.
Absolute pressure and temperature
Compressible-flow equations require absolute temperature and pressure where the gas laws and speed-of-sound relations use thermodynamic state variables.
In U.S. customary units, distinguish psia (absolute) from psig (gauge).
Gauge pressure is measured relative to local atmospheric pressure. Therefore,
pabsolute=pgauge+patmospheric.In SI usage, an unqualified value in kPa is commonly treated as absolute unless it is explicitly identified as gauge pressure.
Convert temperatures to an absolute scale before using equations such as a=γRT. For Fahrenheit, the Rankine temperature is obtained by adding 459.67; for Celsius, the Kelvin temperature is obtained by adding 273.15.
Using gauge pressure or a relative temperature in a compressible-flow relation can produce an incorrect result.
Flow through converging and converging–diverging nozzles
Converging nozzle
In a converging nozzle, subsonic flow accelerates as the area decreases. The flow can reach M=1 at the exit under choked conditions, but it cannot become supersonic within a purely converging nozzle.
Because a normal shock requires supersonic upstream flow, a purely converging nozzle does not contain the normal shocks considered here.
Converging–diverging nozzle
A converging–diverging nozzle has a converging section, a minimum-area throat, and a diverging section. The reservoir supplies the flow at stagnation conditions p0 and T0; the nozzle discharges against a back pressure pb.
The throat is the location where the area is smallest. Under choked conditions, the throat flow is sonic:
Beyond the throat, the diverging section can accelerate the flow to supersonic speed. Whether that happens depends on the back pressure and nozzle operating condition.
Effect of lowering back pressure
If the reservoir and back pressures are equal, there is no pressure difference to drive flow. Lowering the back pressure initiates flow and increases the flow rate.
As back pressure is reduced further:
The flow accelerates through the converging section.
It can reach M=1 at the throat, becoming choked.
With sufficiently low back pressure, it accelerates to supersonic speed in the diverging section.
Depending on the back pressure, a normal shock may stand within the diverging section, at the exit, or outside the nozzle.
Important operating patterns
Subsonic flow throughout
At relatively high back pressure, the flow remains subsonic throughout the nozzle. It accelerates in the converging section and decelerates in the diverging section. The throat has not yet reached sonic conditions.
Sonic throat with subsonic downstream flow
At the choked limit, the throat reaches M=1. A downstream subsonic region may still occur, depending on the operating condition.
Supersonic design operation
At the design back pressure, the flow reaches M=1 at the throat and accelerates smoothly to supersonic speed in the diverging section. There is no internal normal shock. The exit pressure matches the back pressure for the design condition.
Normal shock inside the diverging section
For some back pressures, the flow becomes supersonic after the throat, then crosses a normal shock in the diverging section. It becomes subsonic downstream of the shock.
The flow is treated as follows:
From the throat to the upstream side of the shock: isentropic relations.
Across the shock: normal-shock relations.
From the downstream side of the shock to the exit: isentropic relations.
For a stationary internal shock under the operating condition represented in the nozzle roadmap, the exit pressure matches the back pressure. The stagnation pressure changes across the shock, so the downstream isentropic region has a different stagnation pressure from the upstream region.
Shock at or outside the exit
When the shock lies at the exit, the exit pressure need not equal the back pressure. If the shock is expelled outside the nozzle, external oblique shocks or expansion waves may occur, depending on the pressure mismatch. Those external wave patterns are beyond the normal-shock treatment described here.
Lowering back pressure generally moves an internal shock downstream and eventually out of the nozzle. Raising back pressure generally moves it upstream.
Tracking the sonic area through a shock
The notation A∗ refers to the area at which the Mach number would be one for the relevant isentropic region. When a shock is present, the flow is divided into separate regions, and the value of A∗ can differ upstream and downstream:
A1∗ applies to the upstream isentropic region.
A2∗ applies to the downstream isentropic region.
Therefore, a shock calculation must keep track of the appropriate starred area on each side. For example, the area ratio upstream is A1/A1∗, while the downstream region uses its own A2∗.
Worked setup: a shock in a converging–diverging nozzle
Consider air flowing from a reservoir with
The nozzle has a throat area of 1 m2, a station upstream of the shock with area A1=2 m2, and an exit area of 3 m2. A normal shock stands in the diverging portion, between station 1 and the exit.
Establish the flow regions
At the throat, M=1.
Between the throat and the shock, the flow is supersonic.
Across the shock, use normal-shock relations.
Downstream of the shock, the flow is subsonic.
From the shock to the exit, use isentropic relations.
The reservoir stagnation pressure remains 300 kPa up to the shock. It decreases across the shock and then remains constant through the downstream isentropic region.
Find the Mach number before the shock
The upstream isentropic region has A1∗=1 m2, because the throat is sonic and the throat area is 1 m2. Therefore,
Using the supersonic branch of the isentropic area–Mach relation gives approximately
The branch matters because the same area ratio can correspond to either a subsonic or supersonic Mach number. The nozzle roadmap establishes that station 1 lies in the supersonic region.
Find the static pressure before the shock
At M1≈2.20, the isentropic table gives approximately
Since the shock has not yet been crossed, p01=300 kPa. Thus,
The lecture’s spoken calculation gives 26.08 kPa, but that value is inconsistent with the stated ratio and stagnation pressure: 0.0935(300)=28.05. The ratio and stated conditions imply approximately 28.1 kPa.
The downstream shock properties can then be found from the normal-shock table using M1≈2.20. After crossing the shock, the downstream Mach number is subsonic, so the downstream nozzle region is analyzed with isentropic relations and the new downstream stagnation pressure.

Ask anything
We've read this whole study set, so questions about it get the best answers.