1. Home
  2. Explore
  3. Engineering
  4. Systems and Control Introduction

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

Systems and Control Introduction

Systems and Control Engineering

1. What Is a System?

A system is a collection of physical, biological, or abstract components that interact to achieve an intended objective.

From a control-engineering perspective, a system:

  • Receives an input, also called an excitation.

  • Processes or responds to that input.

  • Produces an output, also called a response.

A system can be represented conceptually as:

Input⟶System⟶Output\text{Input} \longrightarrow \text{System} \longrightarrow \text{Output}Input⟶System⟶Output

The output may depend not only on the current input but, for some systems, also on earlier inputs or stored energy.

Subsystems

A larger system may consist of several interconnected subsystems. Each subsystem has its own input and output, but the subsystems work together to produce the overall system response.

For example:

  • A vehicle may contain engine, transmission, steering, braking, and suspension subsystems.

  • An air-conditioning system may contain sensors, compressors, fans, heat exchangers, and control electronics.

  • A biological system may include organs or physiological processes that interact with one another.

The overall input to the interconnected subsystems produces an overall output from the complete system.


2. Examples of Systems

Control engineering applies to systems from many different domains.

Electrical motor

  • Input: Electrical energy or an electrical signal.

  • System: The motor.

  • Output: Mechanical energy, often measured as torque, speed, or position.

The motor converts electrical input into mechanical motion.

Air conditioner

  • Input: Electrical energy and a temperature-control setting.

  • System: The air-conditioning equipment together with the room being cooled.

  • Output: Room temperature or a change in thermal energy.

The objective is usually to make the room temperature approach and remain near a desired value.

Drug distribution in the human body

  • Input: A prescribed drug dosage.

  • System: The human body and its physiological processes.

  • Output: Drug concentration, distribution through the body, and the drug’s effect on the virus or the patient.

This type of system may involve delays, internal storage, and complex interactions between subsystems.

Automobile

  • Input: A driving or control signal, such as accelerator, braking, or steering commands.

  • System: The vehicle.

  • Output: Acceleration, velocity, or vehicle displacement.

A control system may be designed to regulate the vehicle’s speed, position, or path.


3. Common Notation

The following notation is used frequently in control engineering:

  • ttt: Time variable.

  • u(t)u(t)u(t): Input signal as a function of time.

  • y(t)y(t)y(t): Output signal as a function of time.

  • w(t)w(t)w(t): Time-varying disturbance.

  • δ\deltaδ: A delay in a signal or system.

  • fff: A function that maps one variable or signal to another.

A simple input-output relationship may therefore be written as:

y(t)=f(u(t))y(t) = f\big(u(t)\big)y(t)=f(u(t))

For a dynamic system, the output may depend on the current and previous values of the input:

y(t)=f(u(t),u(t−1),u(t−2),…)y(t) = f\big(u(t),u(t-1),u(t-2),\ldots\big)y(t)=f(u(t),u(t−1),u(t−2),…)

The exact form of this dependence is determined by the system’s physical behavior and mathematical model.


Classification of Systems

Systems can be classified according to several properties:

  1. Linear or nonlinear

  2. Static or dynamic

  3. Time-invariant or time-varying

  4. Causal or non-causal

These classifications describe different aspects of system behavior. A system may be, for example, linear, dynamic, time-invariant, and causal at the same time.


4. Linear and Nonlinear Systems

Linear Systems

A linear system is a system whose output varies linearly with its input. Mathematically, a linear system satisfies both:

  • Superposition

  • Homogeneity

Superposition

If an input x1x_1x1​ produces an output f(x1)f(x_1)f(x1​) and an input x2x_2x2​ produces an output f(x2)f(x_2)f(x2​), then superposition requires:

f(x1+x2)=f(x1)+f(x2)f(x_1+x_2)=f(x_1)+f(x_2)f(x1​+x2​)=f(x1​)+f(x2​)

This means that the response to a sum of inputs equals the sum of the individual responses.

Homogeneity

For a constant aaa, homogeneity requires:

f(ax)=af(x)f(ax)=a f(x)f(ax)=af(x)

This means that scaling the input by a constant scales the output by the same constant.

Combined linearity condition

Together, superposition and homogeneity give the more general condition:

f(ax1+bx2)=af(x1)+bf(x2)f(a x_1+b x_2)=a f(x_1)+b f(x_2)f(ax1​+bx2​)=af(x1​)+bf(x2​)

where aaa and bbb are constants.

A system is linear only when it satisfies both superposition and homogeneity.


Resistor as a Linear System

For a resistor with resistance RRR, Ohm’s law is:

V=IRV=IRV=IR

Therefore, the current is:

I=VRI=\frac{V}{R}I=RV​

Suppose two voltage sources, V1V_1V1​ and V2V_2V2​, are applied with appropriate sign conventions. The total voltage is:

V=V1+V2V=V_1+V_2V=V1​+V2​

The resulting current is:

I=V1+V2RI=\frac{V_1+V_2}{R}I=RV1​+V2​​

which can be separated as:

I=V1R+V2RI=\frac{V_1}{R}+\frac{V_2}{R}I=RV1​​+RV2​​

The individual currents are:

I1=V1RandI2=V2RI_1=\frac{V_1}{R} \qquad\text{and}\qquad I_2=\frac{V_2}{R}I1​=RV1​​andI2​=RV2​​

Thus:

I=I1+I2I=I_1+I_2I=I1​+I2​

This demonstrates superposition.

If the voltage sources are scaled by constants aaa and bbb, the current becomes:

I=aV1+bV2RI=\frac{aV_1+bV_2}{R}I=RaV1​+bV2​​

which is:

I=aV1R+bV2RI=a\frac{V_1}{R}+b\frac{V_2}{R}I=aRV1​​+bRV2​​

Therefore, the resistor also satisfies homogeneity and is a linear system.


Inductor as a Linear System

For an inductor with inductance LLL, the voltage-current relationship is:

V=LdidtV=L\frac{di}{dt}V=Ldtdi​

or equivalently:

didt=VL\frac{di}{dt}=\frac{V}{L}dtdi​=LV​

If the total voltage is the sum of two voltage sources,

V=V1+V2V=V_1+V_2V=V1​+V2​

then:

diTdt=V1+V2L=V1L+V2L\frac{di_T}{dt} = \frac{V_1+V_2}{L} = \frac{V_1}{L}+\frac{V_2}{L}dtdiT​​=LV1​+V2​​=LV1​​+LV2​​

The terms V1L\frac{V_1}{L}LV1​​ and V2L\frac{V_2}{L}LV2​​ are the responses produced by the individual voltage sources. Hence, the total response is the sum of the individual responses.

The inductor also satisfies homogeneity because scaling the voltage scales didt\frac{di}{dt}dtdi​ by the same factor. Under the ideal model, the inductor is therefore a linear system.


Nonlinear Systems

A nonlinear system is a system whose output does not vary linearly with its input. Such a system fails to satisfy superposition, homogeneity, or both.

Diode example

A diode may be modeled by an exponential relationship of the form:

i=i0(eV/τ−1)i=i_0\left(e^{V/\tau}-1\right)i=i0​(eV/τ−1)

where:

  • iii is the diode current.

  • i0i_0i0​ is a reference or saturation current.

  • VVV is the applied voltage.

  • τ\tauτ is a voltage-scaling parameter.

If the input voltage is the sum of two voltages, V1+V2V_1+V_2V1​+V2​, the current is:

i=i0(e(V1+V2)/τ−1)i=i_0\left(e^{(V_1+V_2)/\tau}-1\right)i=i0​(e(V1​+V2​)/τ−1)

This is not equal to:

i0(eV1/τ−1)+i0(eV2/τ−1)i_0\left(e^{V_1/\tau}-1\right) + i_0\left(e^{V_2/\tau}-1\right)i0​(eV1​/τ−1)+i0​(eV2​/τ−1)

Therefore, superposition does not hold.

Similarly, scaling the voltage by a constant aaa does not generally result in the current being scaled by aaa:

i(aV)≠a i(V)i(aV)\neq a\,i(V)i(aV)=ai(V)

Thus, the diode is a nonlinear system.

Linear versus nonlinear systems

Linear systems

  • Satisfy superposition.

  • Satisfy homogeneity.

  • Responses to multiple inputs can be found by adding individual responses.

  • Examples include ideal resistors and ideal inductors.

Nonlinear systems

  • Do not satisfy superposition and/or homogeneity.

  • Responses cannot generally be obtained by simply adding or scaling individual responses.

  • Often contain exponential, quadratic, saturation, switching, or other nonlinear relationships.

  • Example: a diode described by an exponential current-voltage law.


5. Static and Dynamic Systems

Another classification concerns whether the system has memory.

Static Systems

A static system is one whose output at any instant depends only on the input at that same instant.

For a static system:

y(t)=f(u(t))y(t)=f\big(u(t)\big)y(t)=f(u(t))

Static systems are also called memoryless systems because they do not retain information about previous inputs.

Resistor as a static system

For a resistor:

I(t)=V(t)RI(t)=\frac{V(t)}{R}I(t)=RV(t)​

If the applied voltage is suddenly changed to zero, the current immediately becomes zero:

V(t)=0⟹I(t)=0V(t)=0 \quad\Longrightarrow\quad I(t)=0V(t)=0⟹I(t)=0

The resistor does not store energy that would cause its output to continue after the input is removed.


Dynamic Systems

A dynamic system is one whose output depends on past as well as present inputs. Dynamic systems are also called systems with memory.

A general dynamic relationship may be represented as:

y(t)=f(u(t),u(t−Δ),u(t−2Δ),…)y(t)=f\big(u(t),u(t-\Delta),u(t-2\Delta),\ldots\big)y(t)=f(u(t),u(t−Δ),u(t−2Δ),…)

The output may also depend on internal state variables that represent stored energy or accumulated information.

Resistor-inductor circuit

Consider a circuit containing a resistor RRR and an inductor LLL. Its governing equation is:

V=iR+LdidtV=iR+L\frac{di}{dt}V=iR+Ldtdi​

When the voltage source is applied, current develops in the circuit. The inductor stores energy in its magnetic field.

If the voltage source is later removed, then V=0V=0V=0, and the circuit equation becomes:

iR+Ldidt=0iR+L\frac{di}{dt}=0iR+Ldtdi​=0

Rearranging:

didt=−RLi\frac{di}{dt}=-\frac{R}{L}idtdi​=−LR​i

If the initial current is i(0)i(0)i(0), the current for future time ttt is:

i(t)=i(0)e−RLti(t)=i(0)e^{-\frac{R}{L}t}i(t)=i(0)e−LR​t

The current does not become zero instantaneously. Instead, it decays gradually because the inductor releases its stored energy.

Time constant

The decay behavior is determined by the ratio:

τ=LR\tau=\frac{L}{R}τ=RL​

This quantity is called the time constant of the resistor-inductor circuit.

A larger time constant generally means that the current takes longer to decay. The time constant reflects how quickly the stored energy is dissipated through the resistance.

Static versus dynamic behavior

Static systems

  • Output depends only on the current input.

  • Have no memory.

  • Do not store energy in a way that affects future output.

  • Example: an ideal resistor.

Dynamic systems

  • Output depends on current and past inputs.

  • Have memory.

  • Often contain energy-storage elements such as inductors, capacitors, masses, or thermal storage.

  • Example: a resistor-inductor circuit.

A system is dynamic when its present behavior is influenced by information or energy carried over from the past.


6. Time-Invariant and Time-Varying Systems

This classification concerns whether the system’s parameters change with time. It should not be confused with whether the output itself changes over time.

A system can have a time-varying output and still be time-invariant.

Time-Invariant Systems

A time-invariant system produces the same response whenever the same input is applied, regardless of when the experiment is performed.

For a resistor with constant resistance RRR:

I=VRI=\frac{V}{R}I=RV​

If V=1V=1V=1 volt and R=1R=1R=1 ohm, then:

I=1 ampereI=1\text{ ampere}I=1 ampere

The same voltage applied at a later time produces the same current, provided the resistance remains unchanged.

The key issue is whether the system parameters remain constant.

Formal interpretation

If an input u(t)u(t)u(t) produces an output y(t)y(t)y(t), then a time shift in the input should produce an equivalent time shift in the output. In conceptual form:

u(t)→y(t)u(t)\rightarrow y(t)u(t)→y(t)

implies:

u(t−t0)→y(t−t0)u(t-t_0)\rightarrow y(t-t_0)u(t−t0​)→y(t−t0​)

where t0t_0t0​ is any time shift.


Time-Varying Systems

A time-varying system is one whose output depends on the time at which the input is applied because one or more system parameters change with time.

The same input may produce different outputs at different times.

Aircraft mass example

An aircraft burns fuel as it travels. Therefore, its mass changes:

  • At takeoff, the aircraft has a relatively large mass.

  • During flight, fuel is consumed.

  • At landing, the aircraft has a smaller mass.

Since mass affects the aircraft’s dynamics, the system parameters change with time. The aircraft is therefore a time-varying system.

Important distinction

Time dependence can refer to two different things:

  • Dynamic behavior: The output changes with time or depends on past inputs.

  • Time-varying behavior: The system’s parameters change with time.

For example, the current in an inductor may vary with time, but the inductor can still be time-invariant if its inductance LLL remains constant.

Time-invariant versus time-varying systems

Time-invariant systems

  • Parameters remain constant.

  • The same input produces the same response regardless of application time.

  • Example: an ideal resistor with constant RRR.

Time-varying systems

  • One or more parameters change with time.

  • The same input may produce different responses at different times.

  • Example: an aircraft whose mass changes as fuel is burned.


7. Causal and Non-Causal Systems

Causality describes whether a system’s output depends only on inputs available up to the current time or also on future inputs.

Causal Systems

A causal system produces an output using only:

  • The present input.

  • Past inputs.

  • Information already available.

Causal systems are also called non-anticipatory systems because they do not require knowledge of future inputs.

A causal output may depend on:

u(t), u(t−1), u(t−2),…u(t),\ u(t-1),\ u(t-2),\ldotsu(t), u(t−1), u(t−2),…

but not on:

u(t+1), u(t+2),…u(t+1),\ u(t+2),\ldotsu(t+1), u(t+2),…

Most physical systems are causal. A motor, generator, or air conditioner cannot respond today to an input that will be applied tomorrow.

Non-Causal Systems

A non-causal system depends on future input values. Its output at time ttt may depend on values such as u(t+1)u(t+1)u(t+1) or u(t+2)u(t+2)u(t+2).

Such systems are mathematically useful, especially in signal processing and prediction, but they generally cannot be implemented in real time without access to future data.

Examples

  • A mathematical filter that uses future samples of a signal is non-causal.

  • A weather-forecasting method attempts to predict future conditions based on past and present data. The prediction itself is generated causally from available information, but the desired predicted quantity concerns the future.

  • Preparing for an examination involves anticipating possible future questions.

  • Preparing for a cricket match involves considering future opponents, bowlers, and pitch conditions.

In these practical examples, the decision or prediction is based on an expectation of future events. In strict system-theory terms, a real-time predictor can be causal if it uses only past and present data, whereas a system that directly requires future input values is non-causal.

Causal versus non-causal systems

Causal systems

  • Depend on present and past inputs.

  • Do not anticipate unavailable future inputs.

  • Are physically realizable in real time.

  • Examples include motors, generators, and ordinary air conditioners.

Non-causal systems

  • Depend on future inputs.

  • Require future information or previously recorded data.

  • Are commonly used in theoretical analysis, offline processing, and prediction.

  • Cannot generally operate in real time without some source of future information.


Control Systems

8. Purpose of Control Engineering

A control system directs inputs through a plant or process so that the output behaves as desired.

Control engineering aims to:

  • Regulate a system’s output.

  • Make the output follow a desired reference.

  • Reduce the effects of disturbances.

  • Improve system performance.

  • Alter the natural response of a plant to meet a specified objective.

A general control arrangement contains:

  • A plant or process to be controlled.

  • A controller that determines the control action.

  • A reference signal representing the desired output.

  • A control input applied to the plant.

  • An output that is measured or observed.

  • Possible disturbances that interfere with the desired behavior.

  • A feedback path that returns output information to the controller.


9. Plant, Controller, Reference, and Output

Plant

The plant is the physical process or system being controlled.

Examples include:

  • A motor.

  • A car.

  • A missile.

  • A room being heated or cooled.

  • An aircraft.

Controller

The controller determines what input should be applied to the plant. It uses the desired reference and, in a feedback system, information about the actual output.

Reference signal

The reference signal specifies the desired behavior or target output.

Examples include:

  • Desired room temperature: 24∘C24^\circ\text{C}24∘C.

  • Desired vehicle speed.

  • Desired destination for a vehicle.

  • Desired motor position.

Control input

The control input is the physical signal or action applied to the plant.

Examples include:

  • Voltage applied to a motor.

  • Accelerator or steering input in a car.

  • On-off command to an air conditioner.

  • Fuel or actuator command in an aircraft.

Output

The output is the actual measured response of the plant.

Examples include:

  • Actual room temperature.

  • Actual vehicle speed or position.

  • Motor speed or torque.

  • Missile location or velocity.


10. Disturbances

A disturbance is an unwanted signal or influence that changes the plant’s output.

Disturbances may originate inside or outside the system.

Air-conditioning disturbances

For a room controlled by an air conditioner, disturbances may include:

  • People entering the room and releasing body heat.

  • People leaving the room.

  • Changes in outdoor temperature.

  • Changes in ambient environmental conditions.

  • Variations between morning, afternoon, and evening.

A disturbance can cause the actual output to move away from the desired reference.

For example, if a room is maintained at 24∘C24^\circ\text{C}24∘C and several people enter, the temperature may rise to approximately 26∘C26^\circ\text{C}26∘C. A suitable control system must detect and correct this deviation.


Feedback Control

11. Meaning and Function of Feedback

Feedback is the process of sensing the plant output and returning information about that output so it can be compared with the desired reference.

The comparison produces an error or discrepancy:

e(t)=r(t)−y(t)e(t)=r(t)-y(t)e(t)=r(t)−y(t)

where:

  • r(t)r(t)r(t) is the reference or desired output.

  • y(t)y(t)y(t) is the actual output.

  • e(t)e(t)e(t) is the difference between desired and actual output.

The controller uses this information to adjust the control input.

Conceptually:

Reference⟶Comparison⟶Controller⟶Plant⟶Output\text{Reference} \longrightarrow \text{Comparison} \longrightarrow \text{Controller} \longrightarrow \text{Plant} \longrightarrow \text{Output}Reference⟶Comparison⟶Controller⟶Plant⟶Output

The output is measured and sent back to the comparison point.

How feedback changes controller action

The controller’s action depends on the measured output.

For an air conditioner:

  • If the desired temperature is 24∘C24^\circ\text{C}24∘C and the actual temperature is 27∘C27^\circ\text{C}27∘C, the controller must cool the room.

  • If the desired temperature is 24∘C24^\circ\text{C}24∘C and the actual temperature is 21∘C21^\circ\text{C}21∘C, the controller must reduce or stop cooling.

  • If the actual temperature equals the desired temperature, the controller may maintain its current action or switch appropriately.

Therefore, the control action changes as the error changes.

Disturbance rejection

Feedback enables the system to respond to disturbances.

For example:

  1. The desired temperature is 24∘C24^\circ\text{C}24∘C.

  2. The room is initially at 24∘C24^\circ\text{C}24∘C.

  3. Several people enter the room.

  4. The room temperature rises to approximately 26∘C26^\circ\text{C}26∘C.

  5. The temperature sensor detects the change.

  6. The measured temperature is compared with the reference.

  7. The controller detects the error.

  8. The air conditioner increases its cooling action.

  9. The room temperature returns toward 24∘C24^\circ\text{C}24∘C.

Feedback allows a control system to maintain desired performance even when disturbances affect the plant.


12. Open-Loop Control

An open-loop control system applies a control action without measuring the actual output and using it to correct the action.

The system does not automatically compare the output with the desired reference.

Open-loop air conditioner

An open-loop air-conditioning arrangement might include:

  • Plant: The room.

  • Controller or control device: The air conditioner.

  • Control action: Turning the air conditioner on or off, or adjusting a fan regulator.

  • Desired setting: A temperature knob or manually selected operating level.

  • Output: The actual temperature of the room.

If the room becomes warmer because people enter or outdoor conditions change, an open-loop system may not automatically compensate unless a person manually changes the control setting.

Questions for analyzing a control system

When studying an open-loop system, it is important to identify:

  • What is the plant or process?

  • What is the output being observed?

  • What is the desired input or target?

  • What subsystems lie between the controller and the plant?

  • What actuator produces the physical control action?

These elements are later represented mathematically for analysis and design.


13. Closed-Loop Control

A closed-loop control system uses feedback to measure the output and modify the control action.

Closed-loop air conditioner

For a temperature-regulated air conditioner:

  • Plant: The room.

  • Controller: The air conditioner and its control logic.

  • Reference signal: The desired room temperature.

  • Control input: An on-off command or another actuator signal.

  • Output: The measured room temperature.

  • Disturbance: Factors such as people entering or leaving and changes in ambient temperature.

  • Feedback signal: The actual room temperature returned for comparison with the desired temperature.

The system continuously compares the actual temperature with the reference and changes the air conditioner’s action accordingly.

Advantages of closed-loop control

Closed-loop control can:

  • Reduce the effect of disturbances.

  • Correct deviations from the desired output.

  • Maintain the output closer to the reference.

  • Adjust control action automatically.

  • Improve regulation compared with an open-loop arrangement.


14. Car Navigation and Driving as a Closed-Loop System

Driving a car from point AAA to point BBB illustrates closed-loop control.

System components

  • Plant: The car and its motion.

  • Reference: The desired destination, point BBB.

  • Control action: Steering, acceleration, and braking.

  • Control input: The driver’s steering and driving commands.

  • Output: The actual position of the car.

  • Feedback: The driver’s observation of the car’s current position relative to point BBB.

  • Disturbances: Traffic, road conditions, slopes, turns, and other external effects.

Control process

  1. The destination is selected.

  2. The actual position of the car is observed.

  3. The distance and direction relative to the destination are assessed.

  4. Steering, acceleration, or braking commands are adjusted.

  5. The car moves closer to the desired destination.

  6. The process repeats as conditions change.

If the car encounters an uphill road, traffic, or a change in road direction, the driver modifies the control action using updated information about the car’s actual position and motion.


Key Relationships Among the Classifications

The different system classifications describe separate properties:

Linearity

Determines whether responses to inputs can be added and scaled.

  • Linear: obeys superposition and homogeneity.

  • Nonlinear: does not obey these properties.

Memory

Determines whether the output depends on past inputs.

  • Static: memoryless; depends only on the current input.

  • Dynamic: has memory; depends on past and present inputs.

Parameter variation

Determines whether the system’s characteristics change with time.

  • Time-invariant: parameters remain constant.

  • Time-varying: parameters change with time.

Dependence on future inputs

Determines whether the system is anticipatory.

  • Causal: uses present and past inputs.

  • Non-causal: depends on future inputs.

A system can belong to one category from each classification. For example, an ideal resistor is generally:

  • Linear.

  • Static.

  • Time-invariant, if its resistance is constant.

  • Causal.

A resistor-inductor circuit is generally:

  • Linear under ideal assumptions.

  • Dynamic.

  • Time-invariant if RRR and LLL are constant.

  • Causal.

A diode is generally:

  • Nonlinear.

  • Potentially static under an ideal instantaneous current-voltage model.

  • Causal.

  • Time-invariant if its parameters remain constant.


Summary

  • A system is a collection of interacting components that transforms inputs into outputs.

  • Control engineering studies how to model and regulate systems.

  • Systems may consist of interconnected subsystems.

  • A linear system satisfies superposition and homogeneity.

  • An ideal resistor and inductor are examples of linear systems.

  • A diode is nonlinear because its exponential response does not satisfy superposition or homogeneity.

  • A static system depends only on the current input and has no memory.

  • A dynamic system depends on past inputs and may store energy.

  • An inductor creates dynamic behavior because it stores magnetic energy.

  • A time-invariant system has constant parameters and responds consistently regardless of when an input is applied.

  • A time-varying system has parameters that change with time, such as the changing mass of a fuel-burning aircraft.

  • A causal system depends only on present and past inputs.

  • A non-causal system depends on future inputs.

  • A control system modifies the behavior of a plant to achieve a desired objective.

  • Disturbances are unwanted influences that move the output away from the desired value.

  • Feedback measures the output, compares it with the reference, and allows the controller to correct errors and reject disturbances.

  • Open-loop systems do not use output feedback, whereas closed-loop systems continuously use feedback to regulate the output.