1. Home
  2. Explore
  3. Medicine
  4. EKG Basics

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

EKG Basics

πŸ«€ EKG Basics: Understanding Cardiac Electrical Activity

Understanding Electrocardiograms (EKGs) begins with grasping the fundamental physics and physiology of cardiac electrical activity. An EKG visually represents the electrical events of the heart through deflections on a graph.

⚑️ Electrical Flow & EKG Deflections

The direction of positive charge movement relative to a positive electrode determines the deflection on an EKG.

⬆️ Upward Deflection

  • Occurs when a flow of positive charges moves towards the positive electrode.

  • Example: Depolarization waves moving towards a positive electrode will cause an upward deflection.

⬇️ Downward Deflection

  • Occurs when a flow of positive charges moves away from the positive electrode.

  • Example: Depolarization waves moving away from a positive electrode will cause a downward deflection.

πŸ”„ Special Case: Negative Charges

  • A flow of negative charges moving towards a negative electrode will also produce an upward deflection. This is because the negative electrode effectively "sees" the negative charge coming towards it, similar to a positive charge approaching a positive electrode.

βž– Isoelectric Line (Flat Line)

  • Indicates either no net movement of electrical activity or that the electrical activity is moving perpendicular to the axis of the lead.

  • When electrical activity moves perpendicular to a lead's axis, the initial positive deflection (as it approaches) and subsequent negative deflection (as it moves away) are equal in amplitude and cancel each other out, resulting in a flat line.


πŸ—ΊοΈ EKG Waveform in Lead II

Lead II is a commonly used lead in rhythm strips, with its negative electrode on the right arm and positive electrode on the left leg. Its axis runs diagonally from the top right to the bottom left.

🌊 P Wave: Atrial Depolarization

  • Origin: Starts in the sinoatrial (SA) node, located in the upper right atrium.

  • Propagation: Electrical activity spreads from the SA node throughout the atria towards the atrioventricular (AV) node.

  • Mean Vector: The primary mean vector of atrial depolarization moves downward and leftward towards the AV node.

  • Deflection in Lead II: Since this positive charge flows towards the positive electrode of Lead II, it produces an upward deflection.

  • Significance: The P wave indicates atrial depolarization. A normal, upright P wave (sinus P wave) suggests the electrical activity originated from the SA node.

βž– PR Segment: AV Nodal Delay

  • Location: The flat line immediately following the P wave.

  • Physiology: After atrial depolarization, the electrical signal reaches the AV node. The AV node acts as a "wader," slowing down conduction for approximately 0.1 seconds. During this delay, the AV node is depolarized but there is no net movement of electrical charge.

  • Deflection in Lead II: This lack of net electrical movement results in an isoelectric line.

  • PR Interval: The time from the beginning of the P wave to the beginning of the QRS complex. It encompasses atrial depolarization and the AV nodal delay.

πŸ“‰ Q Wave: Septal Depolarization

  • Origin: After the AV nodal delay, the electrical activity passes through the bundle of His and into the bundle branches (right and left).

  • Mechanism: The left bundle branch is primarily responsible for depolarizing the interventricular septum from left to right.

  • Mean Vector: This septal depolarization creates a net vector that moves upward and to the right.

  • Deflection in Lead II: This positive charge flows away from the positive electrode of Lead II, producing a downward deflection.

  • Significance: The Q wave indicates septal depolarization.

  • Pathological Q Waves: While Q waves are a normal physiological component, abnormally wide or deep Q waves, especially in certain leads, can indicate past myocardial infarction (heart attack).

πŸ“ˆ R Wave: Ventricular Depolarization (Main Mass)

  • Origin: Electrical activity continues down the bundle branches and purkinje fibers, spreading through the ventricular myocardium.

  • Ventricular Thickness: The left ventricle is significantly thicker than the right ventricle, generating a larger electrical voltage.

  • Mean Vector: The net vector of ventricular depolarization (the sum of left and right ventricular vectors) is predominantly directed downward and to the left.

  • Deflection in Lead II: This strong positive charge flows towards the positive electrode of Lead II, resulting in a large upward deflection.

  • Significance: The R wave represents the depolarization of the main mass of the ventricles, particularly the left ventricle.

πŸ“‰ S Wave: Ventricular Depolarization (Basal)

  • Origin: The final phase of ventricular depolarization, moving superiorly towards the base of the heart.

  • Mean Vector: This basal ventricular depolarization creates vectors that move upward and to the left/right.

  • Deflection in Lead II: This positive charge moves away from the positive electrode of Lead II, producing a downward deflection.

  • Significance: The S wave indicates the depolarization of the basal portions of the ventricles.

βž– ST Segment: Complete Ventricular Depolarization

  • Location: The flat line following the S wave and preceding the T wave.

  • Physiology: At this point, the entire ventricular myocardium is completely depolarized and positive, but it has not yet begun to repolarize. There is no net movement of electrical charge.

  • Deflection in Lead II: This results in an isoelectric line.

  • Clinical Importance: The ST segment is critically important in diagnosing pathologies like myocardial ischemia or infarction (e.g., ST-elevation myocardial infarction - STEMI).

🌊 T Wave: Ventricular Repolarization

  • Physiology: For the ventricles to relax and be stimulated again, they must repolarize, returning to a negative resting membrane potential. Repolarization typically occurs from the epicardium (outer layer) to the endocardium (inner layer).

  • Mean Vector: This repolarization creates a net vector of negative charge that moves upward and to the right.

  • Deflection in Lead II: A flow of negative charges moving towards the negative electrode (or away from the positive electrode in the direction of the repolarization vector) produces an upward deflection.

  • Significance: The T wave indicates ventricular repolarization.


πŸ“Š The 12 EKG Leads: Views of the Heart

A standard EKG uses 12 leads to provide different electrical "views" of the heart. These leads are categorized into:

  • 3 Limb Leads: I, II, III

  • 3 Augmented Unipolar Limb Leads: aVR, aVL, aVF

  • 6 Precordial (Chest) Leads: V1-V6

πŸ“ Einthoven's Triangle: Limb Leads (I, II, III)

Einthoven's triangle describes the placement and axes of the standard limb leads:

  • Right Arm (RA)

  • Left Arm (LA)

  • Left Leg (LL)

  • Right Leg (RL) (neutral electrode)

Lead

Negative Electrode

Positive Electrode

Axis Direction

Heart View

I

Right Arm (RA)

Left Arm (LA)

Horizontal

High Lateral Wall (LV)

II

Right Arm (RA)

Left Leg (LL)

Down-Left

Inferior Wall (RV, LV)

III

Left Arm (LA)

Left Leg (LL)

Down-Right

Inferior Wall (RV, LV)

  • Waveform Similarity: Leads I, II, and III generally show similar waveforms to Lead II (upright P, QRS, T waves), with slight variations due to their different axes relative to the cardiac vectors.

  • Clinical Significance:

    Lead I: Views the high lateral wall of the left ventricle (LV).

  • Leads II & III: View the inferior wall of the heart (including portions of the right ventricle (RV) and left ventricle (LV)).

πŸ“ˆ Augmented Unipolar Limb Leads (aVR, aVL, aVF)

These leads use a modified system where the EKG machine electronically combines two negative electrodes to create a central reference point, with a single positive electrode viewing the heart.

Lead

Positive Electrode

Axis Direction

Heart View

EKG Waveform (relative to Lead II)

aVR

Right Arm (RA)

Up-Right

Right Ventricle, Basal Septum

Opposite of Lead II (inverted P, QRS, T)

aVL

Left Arm (LA)

Up-Left

High Lateral Wall (LV)

Similar to Lead II (upright P, QRS, T)

aVF

Left Leg (LL)

Down

Inferior Wall (RV, LV)

Similar to Lead II (upright P, QRS, T)

  • aVR: Uniquely, aVR's positive electrode is on the right arm, looking at the heart from the top right. This orientation causes almost all cardiac electrical activity (which generally moves left and down) to move away from aVR's positive electrode. Consequently, aVR typically displays an inverted P wave, QRS complex, and T waveβ€”the exact opposite of Lead II.

  • Clinical Significance:

    aVR: Views the right ventricle and basal septum. Its inverted waveform is a critical indicator of normal lead placement and sinus rhythm.

  • aVL: Views the high lateral wall of the left ventricle. (Combines with Lead I for this view).

  • aVF: Views the inferior wall of the heart. (Combines with Leads II and III for this view).

🫁 Precordial (Chest) Leads (V1-V6)

These are unipolar leads placed directly on the chest wall, providing a horizontal (transverse) plane view of the heart.

πŸ“ Placement

  • V1: Right 4th intercostal space, parasternal line.

  • V2: Left 4th intercostal space, parasternal line.

  • V3: Midway between V2 and V4.

  • V4: Left 5th intercostal space, midclavicular line.

  • V5: Left 5th intercostal space, anterior axillary line.

  • V6: Left 5th intercostal space, midaxillary line.

πŸ“ˆ R-Wave Progression & S-Wave Regression

  • R-Wave Progression: As you move from V1 to V6, the R wave typically increases in size (becomes taller). This reflects the increasing amount of left ventricular muscle being viewed by the electrodes as they move across the chest.

  • S-Wave Regression: Conversely, the S wave typically decreases in size (becomes shallower) from V1 to V6.

  • R/S Ratio:

    V1-V3: R/S ratio is usually less than 1 (S wave is larger than R wave).

  • V4 (Transition Zone): R/S ratio is approximately 1 (R and S waves are roughly equal).

  • V5-V6: R/S ratio is usually greater than 1 (R wave is larger than S wave).

Clinical Importance: Abnormal R-wave progression (e.g., poor R-wave progression) can indicate various pathologies, including myocardial infarction or ventricular hypertrophy.

πŸ«€ Heart Views by Precordial Leads

  • V1-V3: Primarily view the right ventricle and basal septum. (Can be combined with aVR).

  • V2-V4: View the anterior wall of the heart.

  • V5-V6: View the lateral wall of the left ventricle. (Can be combined with Leads I and aVL for a comprehensive lateral view).


πŸ“ EKG Paper & Interval Measurements

The EKG paper is a grid system that allows for precise measurement of time (horizontal axis) and voltage/amplitude (vertical axis).

πŸŸ₯ Large Boxes

  • Dimensions: 5 millimeters (mm) in width and 5 mm in height.

  • Time (Width): Each large box represents 0.20 seconds.

  • Voltage (Height): Each large box represents 0.5 millivolts (mV).

⬜ Small Boxes

  • Dimensions: 1 millimeter (mm) in width and 1 mm in height.

  • Time (Width): Each small box represents 0.04 seconds (0.20 seconds / 5 small boxes).

  • Voltage (Height): Each small box represents 0.1 millivolts (mV) (0.5 mV / 5 small boxes).

    Note: Voltage measurement (millivolts) is less frequently emphasized for basic rhythm interpretation but is crucial for conditions like low QRS voltage or ST segment elevation/depression (e.g., 1mm ST elevation = 1 small box).

⏱️ Key Intervals & Normal Parameters

Precise measurements of intervals and wave durations are vital for diagnosing various cardiac conditions.

EKG Component

Description

Normal Duration/Parameter

Clinical Significance

P Wave

Atrial depolarization

Usually < 0.12 seconds (3 small boxes)

Indicates atrial activity; abnormalities suggest atrial enlargement or ectopic foci.

PR Interval

Start of P wave to start of QRS complex

< 0.20 seconds (1 large box)

Time for atrial depolarization and AV nodal delay. Prolonged PR interval indicates AV block.

QRS Complex

Ventricular depolarization

< 0.12 seconds (3 small boxes)

Ventricular activation. Wide QRS indicates conduction delay (e.g., bundle branch block, ventricular rhythm).

ST Segment

End of QRS to start of T wave

Isoelectric (flat)

Represents period when ventricles are fully depolarized. Elevation or depression indicates ischemia or infarction.

T Wave

Ventricular repolarization

Varies, typically upright

Ventricular repolarization. Inversions or peaking can indicate ischemia or electrolyte imbalances.

QT Interval

Start of QRS to end of T wave

Males: < 430 ms<br>Females: < 460 ms

Total time for ventricular depolarization and repolarization. Prolonged QT interval increases risk of Torsades de Pointes (a life-threatening arrhythmia).

Critical Note: While general guidelines exist for QT interval, it is rate-dependent and often requires correction (QTc) using formulas (e.g., Bazett's formula) for accurate assessment, especially at different heart rates. A QTc approaching 500 ms is generally considered dangerously prolonged.

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent