EKG Interpretation Basics
EKG Interpretation Basics
Purpose of an Electrocardiogram
An electrocardiogram (ECG or EKG) records the heart’s electrical activity. It assesses the heart’s electrical conduction system, which coordinates contraction and relaxation of the atria and ventricles.
The electrical system must function properly so that:
The atria contract and move blood into the ventricles.
The ventricles contract and pump blood to the lungs and the rest of the body.
The heart relaxes and refills before the next contraction.
Abnormal electrical activity can produce dysrhythmias, including atrial flutter, atrial fibrillation, and ventricular tachycardia.
Blood Flow Through the Heart
The sequence of blood flow helps explain the relationship between electrical activity and cardiac contraction.
Right side of the heart
Oxygen-depleted blood returns from the body and enters the right atrium.
The right atrium contracts and sends blood through the tricuspid valve.
Blood enters the right ventricle.
The right ventricle contracts and sends blood through the pulmonic valve into the pulmonary artery.
The pulmonary artery carries blood to the lungs.
Gas exchange occurs in the lungs, where carbon dioxide is removed and oxygen is added.
Left side of the heart
Oxygenated blood returns from the lungs through the pulmonary veins.
Blood enters the left atrium.
The left atrium contracts and sends blood through the mitral valve.
Blood enters the left ventricle.
The left ventricle contracts and sends blood through the aortic valve into the aorta.
The aorta distributes oxygen-rich blood throughout the body.
The electrical conduction system ensures that the atria contract before the ventricles, allowing the ventricles to fill efficiently.
Depolarization and Repolarization
The electrical activity of the heart depends on changes in the electrical charge of specialized cardiac cells.
Polarization
A resting cardiac cell is polarized:
The inside of the cell is relatively negative.
The cell membrane is relatively impermeable to sodium ions.
The cell is not actively contracting.
Depolarization
When an electrical impulse reaches the cell:
The cell membrane becomes more permeable to sodium.
Positively charged sodium ions enter the cell.
The inside of the cell becomes less negative and more positive.
The cell becomes depolarized.
Depolarization causes the cardiac muscle to contract.
Depolarization leads to contraction.
Examples include:
Atrial depolarization: contraction of the atria.
Ventricular depolarization: contraction of the ventricles.
Repolarization
After contraction, the cell returns toward its resting negative state. This process is called repolarization and corresponds to relaxation.
Repolarization leads to relaxation.
A useful memory aid is that “relax” begins with “re,” just like “repolarization.”
Examples include:
Atrial repolarization: relaxation of the atria.
Ventricular repolarization: relaxation of the ventricles.
Electrical Conduction System of the Heart
Sinoatrial node
The sinoatrial (SA) node is located in the upper portion of the right atrium. It is normally the heart’s natural pacemaker.
The SA node:
Initiates the electrical impulse.
Normally establishes a heart rate of approximately 60–100 beats per minute.
Causes atrial depolarization.
Initiates atrial contraction.
Because the normal impulse originates in the SA node, a normal rhythm is called normal sinus rhythm.
Atrial conduction pathways and Bachmann’s bundle
After the SA node fires, the impulse spreads across the atria through specialized conduction pathways.
Bachmann’s bundle carries the impulse toward the left atrium, allowing both atria to depolarize and contract.
Atrioventricular node
The atrioventricular (AV) node is located between the atria and ventricles. It is often called the gatekeeper of the heart.
The AV node:
Receives the impulse from the atria.
Briefly delays conduction.
Allows the atria time to empty blood into the ventricles.
Prevents the atria and ventricles from contracting simultaneously.
An abnormally prolonged delay through this pathway can produce a prolonged PR interval, which may indicate a heart block.
Bundle of His
After passing through the AV node, the electrical impulse travels into the bundle of His, also called the atrioventricular bundle.
This pathway carries the impulse from the AV node toward the ventricles.
Right and left bundle branches
The bundle of His divides into:
Right bundle branch: conducts the impulse through the right ventricle.
Left bundle branch: conducts the impulse through the left ventricle.
Purkinje fibers
The bundle branches transmit the impulse to the Purkinje fibers, which distribute the electrical signal throughout the ventricular muscle.
This produces coordinated ventricular depolarization and contraction.
Overall conduction sequence
The normal sequence is:
SA node
Atrial conduction pathways and Bachmann’s bundle
AV node
Bundle of His
Right and left bundle branches
Purkinje fibers
This electrical sequence appears on the EKG as the PQRST complex.
EKG Strip Paper and Time Measurements
EKG paper is divided into small boxes grouped into larger squares.
Small boxes
Each small box represents:
Large squares
Each large square contains five small boxes:
These measurements are used to determine the duration of waves, intervals, and complexes.
Six-second rhythm strips
A six-second EKG strip contains 30 large squares:
For a six-second strip, the approximate heart rate is calculated by:
This method can be used to estimate both the atrial rate and ventricular rate.
The PQRST Complex
The PQRST complex represents the electrical events that produce one cardiac cycle.
P Wave
The P wave represents atrial depolarization.
It indicates:
The electrical impulse began in the SA node.
The atria are being stimulated to contract.
The impulse is spreading through the atrial muscle.
In a normal rhythm, the P wave should:
Be present before each QRS complex.
Be rounded and upright in the appropriate leads.
Be uniform in appearance.
Measure less than 0.12 seconds, or fewer than three small boxes.
A normal rhythm generally has one P wave for every QRS complex.
PR Segment
The PR segment occurs after the P wave and before the QRS complex.
It represents:
Completion of atrial depolarization.
The delay as the impulse passes through the AV node.
Time for the atria to empty into the ventricles.
The PR segment should normally be relatively flat or isoelectric.
PR Interval
The PR interval begins at the start of the P wave and ends at the beginning of the QRS complex.
It represents the total time required for the electrical impulse to travel:
Through the atria,
Through the AV node,
Into the ventricular conduction system.
The normal PR interval is:
This corresponds to approximately three to five small boxes.
A PR interval longer than 0.20 seconds may suggest a heart block, such as first-degree AV block.
The PR interval differs from the PR segment:
PR segment: begins after the P wave and ends before the QRS complex.
PR interval: begins at the start of the P wave and ends at the start of the QRS complex.
QRS Complex
The QRS complex represents ventricular depolarization and leads to ventricular contraction.
The three components are:
Q wave: first downward deflection.
R wave: first upward deflection.
S wave: downward deflection following the R wave.
The QRS complex should:
Follow each P wave.
Have a consistent appearance.
Measure no more than 0.12 seconds.
Occupy no more than three small boxes.
The QRS duration is measured from the beginning of the Q wave to the end of the S wave.
A widened QRS complex may indicate abnormal ventricular conduction. Ventricular tachycardia, for example, commonly produces wide QRS complexes.
Atrial repolarization
Atrial repolarization occurs during the QRS complex, but it is usually not visible. The electrical activity of the much larger ventricles overshadows the atrial repolarization signal.
J Point
The J point is the point where the QRS complex ends and the ST segment begins.
It marks the transition from ventricular depolarization to the next phase of ventricular electrical activity.
ST Segment
The ST segment begins at the end of the QRS complex and ends at the beginning of the T wave.
It represents:
Completion of ventricular depolarization.
The beginning of ventricular repolarization.
The ST segment should normally be isoelectric, meaning flat.
Abnormal findings include:
ST elevation: the ST segment rises above the baseline.
ST depression: the ST segment falls below the baseline.
The source material identifies no more than approximately one millimeter of elevation or depression as the expected limit when assessing the segment.
T Wave
The T wave represents the beginning of ventricular repolarization, which produces ventricular relaxation.
A normal T wave is generally:
After the QRS complex.
Rounded.
Upright in most leads.
After the T wave, the tracing usually returns to a flat, isoelectric line as ventricular repolarization is completed.
U Wave
A U wave may occasionally appear after the T wave. It is not present in every patient.
A visible U wave may be associated with hypokalemia, or a low serum potassium level.
QT Interval
The QT interval begins at the start of the QRS complex and ends at the end of the T wave.
It represents the total time required for the ventricles to:
Depolarize and contract.
Repolarize and relax.
A typical QT interval is approximately:
Important influences on the QT interval include:
Sex: men generally have shorter QT intervals than women.
Heart rate: faster heart rates usually produce shorter QT intervals.
Prolongation: a prolonged QT interval increases the risk of ventricular dysrhythmias, including torsades de pointes.
Relationship Between the PQRST Components and Cardiac Activity
The electrical and mechanical events occur in the following order:
P wave: atrial depolarization begins, causing atrial contraction.
PR segment: atrial depolarization is complete, and the AV node delays conduction.
QRS complex: ventricular depolarization begins, causing ventricular contraction; atrial repolarization occurs but is hidden.
ST segment: ventricular depolarization is completed, and ventricular repolarization begins.
T wave: ventricular repolarization begins and the ventricles relax.
Flat isoelectric line: ventricular repolarization is complete.
The next P wave begins a new cardiac cycle.
Systematic Rhythm Analysis
A rhythm strip should be at least six seconds long when using the six-second rate calculation method.
A systematic analysis evaluates:
P waves
QRS complexes
T waves
Intervals and segments
For both the P waves and QRS complexes, the three key features are:
Regularity
Rate
Resemblance
Analysis of P Waves
P-wave regularity
P-wave regularity assesses whether the atrial rhythm is consistent.
To evaluate regularity:
Compare the distance from one P wave to the next.
Use calipers or a strip of paper to mark the interval between consecutive P waves.
Move the measurement through the strip.
Determine whether the P waves remain evenly spaced.
In normal sinus rhythm, the P waves are regular.
Atrial rate
To calculate the atrial rate on a six-second strip:
Count the number of P waves.
Multiply the number by 10.
For example, eight P waves in six seconds produce:
The normal sinus atrial rate is approximately 60–100 beats per minute.
P-wave resemblance
A normal P wave should:
Be rounded.
Be upright in the appropriate leads.
Look similar from beat to beat.
Measure less than 0.12 seconds.
Appear once before each QRS complex.
Analysis of QRS Complexes
QRS regularity
QRS regularity assesses the ventricular rhythm.
To evaluate regularity:
Compare the distance from one R wave to the next.
Use calipers or paper to compare consecutive R–R intervals.
Determine whether the QRS complexes are evenly spaced.
In normal sinus rhythm, the QRS complexes are regular.
Ventricular rate
To calculate the ventricular rate on a six-second strip:
Count the QRS complexes.
Multiply the number by 10.
For example, eight QRS complexes in six seconds produce:
In normal sinus rhythm, the atrial and ventricular rates should match and generally fall between 60 and 100 beats per minute.
QRS resemblance
A normal QRS complex should:
Appear after each P wave.
Have a consistent appearance.
Measure no more than 0.12 seconds.
Occupy no more than three small boxes.
Analysis of T Waves
The T wave should:
Follow each QRS complex.
Be rounded.
Be upright in most leads.
Have a consistent appearance.
Abnormal T-wave shape, direction, or timing may indicate altered ventricular repolarization, although interpretation depends on the rhythm and the EKG lead being examined.
Analysis of Intervals and Segments
PR interval
The PR interval should:
Begin at the start of the P wave.
End at the start of the QRS complex.
Measure 0.12–0.20 seconds.
Remain consistent throughout the strip.
A prolonged PR interval may indicate delayed AV conduction or heart block.
ST segment
The ST segment should:
Begin at the end of the QRS complex.
End at the beginning of the T wave.
Remain flat or isoelectric.
Have no significant elevation or depression.
QT interval
The QT interval should:
Begin at the start of the QRS complex.
End at the end of the T wave.
Generally measure approximately 0.35–0.44 seconds.
Be interpreted in relation to the heart rate.
A prolonged QT interval can increase the risk of dangerous ventricular dysrhythmias.
Example: Identifying Normal Sinus Rhythm
A six-second strip is analyzed using the systematic approach.
P waves
P waves occur at regular intervals.
There are eight P waves in six seconds.
Atrial rate:
Each P wave is rounded and upright.
Each P wave precedes one QRS complex.
Each P wave measures approximately 2.5 small boxes:
This is within the normal limit of less than 0.12 seconds.
QRS complexes
QRS complexes occur regularly.
There are eight QRS complexes in six seconds.
Ventricular rate:
The atrial and ventricular rates are equal.
Each QRS complex follows a P wave.
Each QRS complex measures approximately 2.5 small boxes, or 0.10 seconds.
The QRS duration is within the normal limit of no more than 0.12 seconds.
Intervals and segments
The PR interval measures approximately 3.5 small boxes:
The PR interval is within the normal range and remains consistent.
The QT interval measures approximately nine small boxes:
The QT interval is within the expected range.
The ST segment is flat, without significant elevation or depression.
T waves appear after the QRS complexes and are upright and appropriately rounded.
Rhythm interpretation
The rhythm meets the criteria for normal sinus rhythm:
Regular P waves.
Regular QRS complexes.
One P wave before every QRS complex.
Matching atrial and ventricular rates.
Rate of approximately 80 beats per minute.
Normal P-wave, PR-interval, QRS, ST-segment, T-wave, and QT-interval findings.
Normal sinus rhythm originates in the SA node and produces a regular atrial and ventricular rhythm with a rate of approximately 60–100 beats per minute.