🕒 Preparation and Equipment
Use a watch with a second hand — preferably a sweeping second hand (continuous motion) rather than a ticking one, because ticking can interfere with counting.
Start counting at a comfortable number on the watch face (e.g., 12 or 6). Starting at awkward numbers (like 7) makes it harder to calculate when 30 seconds have passed. For example:
Start at 12 → 30 seconds later is at 6.
Start at 6 → 30 seconds later is at 12.
Do not stare at the watch while counting — it can cause confusion between the watch’s movement and your counting. Look away after noting the start time, and only glance back periodically.
Auscultation (listening with a stethoscope) must be done on bare skin. Placing a stethoscope over clothing or a gown creates artifact from rustling and yields inaccurate sounds. This applies to lung, heart, bowel sounds, and blood pressure.
🌡️ Temperature
Temperature can be taken using several routes. The same electronic thermometer unit is often used for oral/axillary (blue probe) and rectal (red probe). Do not mix probes.
Oral Temperature
Remove the probe from the device and attach a probe cover.
Insert the probe into the patient’s mouth, positioning it in the posterior sublingual pocket (the deepest part under the tongue).
Ask the patient to close their lips around the metal probe (not teeth). If they instinctively touch the probe, ask them to touch only the plastic part to avoid altering the reading.
Wait for the device to beep, then eject the probe cover using the button on the back. Return the probe to the monitor.
Axillary Temperature
Change the monitor setting to axillary mode (usually one button).
Attach a probe cover, then place the probe in the patient’s axillary midline (armpit) directly on skin.
Have the patient hold their arm against their body to create a seal.
Wait for the beep, remove, and eject the cover.
Temporal Temperature
Use a temporal artery thermometer (with a cap).
Place the scanner against the patient’s forehead, press the button, and drag it along the hairline toward the ear.
Remove the cap between patients.
Tympanic Temperature
Attach a probe cover (often stored inside the device).
For adults: pull the pinna (top of ear) up and back to straighten the ear canal.
For children under 3 years: pull the pinna down and back.
Insert the probe gently, aiming toward the jawline (along the ear canal).
Press the button, wait for the beep, then withdraw. Eject the probe cover using the trigger button.
Rectal Temperature
Position the patient in modified left lateral recumbent (Sims’) position.
Use the red probe (rectal thermometer). Attach a probe cover.
Apply lubricant to the probe tip.
Expose the anus, then insert the probe approximately 1 inch (2.5 cm) into the rectum, pointing toward the umbilicus (belly button).
Wait for the beep, remove, and eject the probe cover. Clean the patient’s anal area and return them to a comfortable position.
💓 Pulse
Pulse is assessed for:
Rate (beats per minute)
Strength (rated +1 to +4: +1 = weak/thready, +4 = bounding)
Equality (compare bilateral pulses — check both sides simultaneously, but count only one)
Radial Pulse
Palpate with two or three finger pads on the wrist, just proximal to the thumb (follow the thumb’s base to the radial artery).
Press firmly enough to feel the bounce but not so hard that you occlude the artery.
Count for 30 seconds if the pulse is regular (consistent beat interval), then multiply by 2 to get beats per minute.
If the pulse is irregular, count for the full 60 seconds.
Example: 32 beats in 30 seconds → 64 beats per minute (regular).
Apical Pulse
Use a stethoscope placed at the fifth intercostal space, left midclavicular line (the point of maximal impulse, or PMI).
Listen for 30 seconds (regular) or 60 seconds (irregular).
Tip for beginners: Close your eyes and gently bounce your head in rhythm with the heartbeat to stay focused, especially with distracting sounds or patient movement.
Practice counts (from demonstration):
First count (regular): 46 beats in 30 sec → 92 bpm
Second count (regular): 52 beats in 30 sec → 104 bpm
Irregular count (full minute): 136 beats → 136 bpm
Key Rule: For an irregular pulse, you must count a full 60 seconds to get an accurate rate. Shortened counting (30 sec × 2) only works for regular rhythms.
👃 Respirations
Taking respirations requires covert observation because if the patient knows you are watching their breathing, their pattern and depth will change.
Procedure
After completing a pulse count, keep your fingers on the radial pulse (or another pulse point) but start counting breaths instead.
Observe the rise and fall of the chest (or abdomen). If breathing is hard to see, you can:
Rest your hand gently on the patient’s shoulder to feel the movement.
Place the patient’s hand on their own chest (or gently lift their arm so it rests on their chest) — the arm will move with each breath.
Count each full breath (inhalation + exhalation) for 30 seconds if the pattern is regular, then multiply by 2 to get breaths per minute.
If the pattern is irregular, count for 60 seconds.
Assess Three Components
Rate: breaths per minute (normal adult 12–20)
Pattern: regular or irregular
Depth: shallow, normal, labored
Remember: The patient should not know you are counting respirations. This is why the method is “sneaky” — you pretend you are still taking the pulse while actually counting breaths.
💉 Blood Pressure
Preparation and Arm Selection
Patient should be relaxed, arm supported (not held up by the patient), legs uncrossed.
Apply the cuff 1 inch (2.5 cm) above the brachial artery, snugly.
Contraindicated arms:
IV line running
PICC line
AV fistula (for dialysis)
Same side as a mastectomy (lymph node removal)
Use clinical judgment if both arms have issues; choose the one that gives the most accurate reading.
One‑Step / Combined Method (Palpatory + Auscultatory)
This method first determines the approximate systolic pressure by palpation, then listens for the actual pressures.
Palpate the radial artery while inflating the cuff.
Inflate until the radial pulse disappears — note the pressure at which it disappears.
Continue inflating another 30 mmHg above that point (to ensure you hear Korotkoff sounds).
Place the stethoscope (bell or diaphragm) over the brachial artery at the anticubital fossa. Hold it firmly against the skin; wrap your thumb around the forearm to keep it steady and minimize artifact.
Release the cuff valve gradually (about 2–3 mmHg per second).
Listen for the first Korotkoff sound — this is the systolic pressure.
Continue listening; the point where sounds disappear is the diastolic pressure.
Example from Demonstration
First reading: systolic 130, diastolic 80 → 130/80 mmHg
Second reading: 162/110 mmHg
Third reading: 118/66 mmHg
Tip: Hold the stethoscope snugly against the skin with your fingers in the scope and thumb wrapped around the arm. This prevents movement artifact and keeps the scope in place, even if the patient shifts.
Key Takeaways
Vital Sign | Key Assessment Points | Counting Rule |
|---|---|---|
Pulse | Rate, strength (+1 to +4), equality | 30 sec (regular) or 60 sec (irregular) |
Respirations | Rate, pattern, depth (covert count) | 30 sec (regular) or 60 sec (irregular) |
Temperature | Route‑specific (oral, axillary, temporal, tympanic, rectal) | Wait for device beep |
Blood Pressure | Systolic (first sound), diastolic (last sound) | Inflate 30 mmHg above radial pulse disappearance |
Always use bare skin for auscultation.
Use a sweeping second hand watch; start at a comfortable number (e.g., 12).
For irregular rhythms (pulse or respirations), count the full minute.
When taking blood pressure, choose an arm without contraindications (IV, fistula, mastectomy side, etc.).

Ask anything