1989 Geomagnetic Storm
- 28Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
28 questions
- 1The March 1989 geomagnetic storm that blacked out Hydro-Quebec began with a cluster of_____on the sun's surface.
Hint
Think of the dark, magnetic regions on the sun.
Answer
sunspots
- 2The coronal mass ejections from the 1989 solar flares consisted of huge bursts of_____.
Hint
These are charged particles from the sun.
Answer
solar wind
- 3In Quebec, the induced currents from the geomagnetic storm could not dissipate into the ground due to the region's geology: a shield of hard rock that is a poor_____.
Hint
Opposite of a good electrical conductor.
Answer
conductor
- 4The first pieces of equipment to trip during the 1989 blackout were_____.
Hint
These are devices that manage reactive power.
Answer
static compensators
- 5In most modern power grids, the voltage and current alternate at a frequency of_____cycles per second, depending on the region.
Hint
The two common AC frequencies used worldwide.
Answer
50 or 60
- 6The relationship between voltage, current, and resistance in a circuit is defined by_____.
Hint
A fundamental equation in electrical engineering.
Answer
Ohm's law
- 7In the example circuit, with 10.1 volts and 1.2 amps, the resistance of the lightbulb was calculated as approximately_____ohms.
Hint
Use Ohm's law: R=V/I.
Answer
8
- 8Electrical power is calculated by multiplying_____and current together.
Hint
The product of two fundamental quantities.
Answer
voltage
- 9In a DC circuit, the voltage and current are_____, meaning they do not change direction.
Hint
Direct current flows in one direction.
Answer
constant
- 10When a capacitor is inserted into an AC circuit, the_____waveform leads the voltage waveform.
Hint
The capacitor charges before voltage rises.
Answer
current
- 11When an inductor is inserted into an AC circuit, the current waveform_____the voltage waveform.
Hint
Inductors resist changes in current, causing a delay.
Answer
lags
- 12For a purely resistive load, the current and voltage are in_____, so power is always positive.
Hint
They peak at the same time.
Answer
sync
- 13For a purely reactive load like an ideal capacitor or inductor, the average power consumed over a full cycle is_____.
Hint
Energy is only stored and returned.
Answer
zero
- 14The unit for reactive power is the_____(VAR).
Hint
VAR stands for this.
Answer
volt-amp reactive
- 15By convention, inductive devices are said to_____reactive power, while capacitive devices supply it.
Hint
They absorb reactive power from the grid.
Answer
consume
- 16The total power flowing through the grid, combining real and reactive power, is called_____power.
Hint
It is the hypotenuse of the power triangle.
Answer
apparent
- 17The power factor is the ratio of real power to_____power.
Hint
It measures how efficiently power is used.
Answer
apparent
- 18Distribution transformers are often rated in_____(kVA) rather than kilowatts because they must handle both real and reactive power.
Hint
Unit of apparent power.
Answer
kilovolt-amps
- 19Large industrial customers with many induction motors typically have a_____power factor.
Hint
They consume a lot of reactive power.
Answer
low
- 20The PV curve relates power flowing to a load to the_____it sees.
Hint
Voltage drops as power increases.
Answer
voltage
- 21On the PV curve, the point beyond which increasing demand reduces deliverable power is called the_____.
Hint
It is the peak of the curve.
Answer
nose
- 22Lower power factor shifts the nose of the PV curve to the_____, reducing voltage stability margin.
Hint
It moves downward and leftward.
Answer
left
- 23A_____is a large unloaded motor that can generate or absorb reactive power and provide inertia to the grid.
Hint
It spins freely without mechanical load.
Answer
synchronous condenser
- 24_____capacitor banks are connected across transmission lines to increase power factor and boost voltage.
Hint
They are installed in parallel with the lines.
Answer
Shunt
- 25A static VAR compensator (SVC) uses electronics to rapidly switch inductors and capacitors to adjust to_____conditions.
Hint
Conditions change quickly on the grid.
Answer
dynamic
- 26During the 1989 storm, the induced currents increased the_____power demand, leading to waveform distortions that the SVCs could not handle.
Hint
Related to energy storage and return.
Answer
reactive
- 27One challenge with renewables like solar and wind is that they can cause_____swings when generation changes suddenly.
Hint
Reactive power affects this.
Answer
voltage
- 28Australia is exploring repurposing old fossil fuel generators into_____to help stabilize the grid with renewable sources.
Hint
These provide inertia and reactive power.
Answer
synchronous condensers