1. Home
  2. Explore
  3. Physics
  4. Gravitational Time Dilation

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

Gravitational Time Dilation

Gravitational Time Dilation and Optical Atomic Clocks

Gravity, time, and general relativity

General relativity predicts that clocks at different gravitational potentials run at different rates. A clock higher above a massive body, where the gravitational field is weaker, runs faster than a clock closer to that body. Thus, a clock on a mountain should gain time relative to a clock at a lower elevation.

This effect is called gravitational time dilation. It is one of the ways gravity affects time, and it has been repeatedly confirmed experimentally. For clocks separated vertically by about 2.7 kilometers, the predicted difference is roughly 25 billionths of a second per day.

Gravity is often illustrated as the bending of spacetime, for example with a funnel-shaped surface. That image can suggest that gravity is mainly a distortion of space. In the explanation presented here, the dominant effect relevant to clocks near Earth is the way gravity changes the passage of time: time runs more slowly closer to a massive object and more quickly farther away.

A precise comparison of clocks at different heights provides a direct test of how gravity affects the rate of time.

Why test a theory that already works?

General relativity’s predictions for gravitational time dilation have been tested many times. More precise tests remain important because physicists expect that general relativity will eventually need to be reconciled with quantum mechanics.

Quantum mechanics allows a particle to exist in a superposition of different locations. General relativity describes how the distribution of mass and energy affects spacetime. If a massive particle is in a superposition of two places, each location would correspond to a different gravitational influence on spacetime. The theories do not yet provide a settled answer to what spacetime does in that situation.

This leaves a fundamental question: Does gravity itself obey quantum-mechanical rules? Extremely precise experiments can search for small departures from general relativity’s predictions. Such a departure might indicate that a correction to the theory is needed and could reveal where the classical description of gravity breaks down.


Why atomic clocks are useful

An atomic clock measures time using a highly consistent natural frequency associated with an atomic transition. Unlike a mechanical pendulum or a vibrating quartz crystal, the clock’s reference comes from the same atomic properties wherever atoms of the same isotope are found.

Two qualities describe clock performance:

  • Stability is how consistently one tick matches the next.

  • Accuracy is how closely the measured frequency matches the atom’s true resonant frequency.

A clock can be stable but inaccurately calibrated, or accurate on average while having less stable ticks. Its practical performance depends on both the atoms and the quality of the apparatus.

Atomic clocks are also used to keep international time standards synchronized. Their measurements contribute to Coordinated Universal Time, or UTC, which underlies the time used by many communication and computing systems.

Caesium clocks and the definition of the second

A caesium-133 clock uses a transition between two atomic energy levels. When an atom absorbs a photon whose energy matches the gap between those levels, it can move from one level to the other. Because photon energy depends on frequency, the transition occurs at a characteristic frequency.

Since 1967, the official definition of one second has been based on exactly 9,192,631,770 oscillations associated with the caesium-133 transition. A caesium fountain clock uses these atoms to realize that definition experimentally.

The best caesium clocks described in the source achieve a fractional accuracy of about one part in 101610^{16}1016. At that level, a clock would gain or lose about a second over tens of millions to a hundred million years. This is extraordinarily precise, but it is not sufficient for the most sensitive tests of gravity discussed here.


Optical atomic clocks using ytterbium

To improve clock precision, scientists can use a transition with a much higher frequency. More oscillations occur during each second, making it possible to resolve smaller fractional changes in the clock’s rate.

Ytterbium-171 is a suitable candidate for an optical clock. Its transition frequency is in the optical part of the spectrum and is about 56,000 times higher than the frequency used by a caesium clock. It corresponds to about 518 trillion oscillations per second and can support fractional accuracy of about one part in 101810^{18}1018. At this accuracy, the clock would gain or lose a second only over a period longer than the age of the universe.

A higher frequency alone is not enough. The atoms must be prepared and controlled so that their measured transition frequency is not blurred by unwanted effects.

Preparing ytterbium atoms

When ytterbium is solid, nearby atoms can affect one another’s electrons. These interactions broaden the transition frequency, making the natural resonance difficult to identify precisely. The material is therefore heated in an oven to about 500 degrees Celsius, turning it into a vapor. A stream of atoms then travels from the oven into a vacuum chamber.

The atoms’ motion creates another challenge. An atom moving toward or away from a photon experiences a Doppler shift: it absorbs light as if the light had a slightly different frequency. In the described setup, the shift could create an error of about one part in a million—far larger than the tiny errors the experiment is designed to detect.

Laser cooling

The team cools the atoms with lasers in stages:

  1. A blue laser reduces the atoms’ temperature from hundreds of kelvins to about a millikelvin.

  2. A green laser then cools them further, to around a microkelvin.

Laser cooling works by exploiting the Doppler shift. The laser is tuned slightly below the frequency the atoms absorb. An atom moving toward a laser beam sees its light shifted toward the absorption frequency and is more likely to absorb a photon from that beam. Each absorbed photon transfers a small amount of momentum opposite the atom’s motion, slowing it down.

The atoms later emit photons in random directions. Across many absorption-and-emission cycles, the random recoil from emitted photons averages out, while the directed absorption process continues to slow the atoms. The result is an extremely cold atomic sample, close to absolute zero.

Trapping atoms in an optical lattice

Once cooled, the atoms must be held nearly still. The apparatus uses a laser beam reflected back on itself. The outgoing and reflected light interfere, forming a repeating pattern called a standing wave, with locations of high and low intensity.

Although ytterbium atoms are electrically neutral overall, the electric field of the light slightly displaces their positive and negative charges. This creates an induced dipole. The interaction gives the atom potential energy that varies with the standing wave’s intensity, producing locations where the atom is drawn toward a minimum of potential energy.

The repeating arrangement of these trapping sites is an optical lattice. In the described clock, the atoms are confined in sites about 300 nanometers across. Restricting their motion greatly reduces the motion-related frequency shifts that would otherwise interfere with the measurement.

Reading the clock

The optical clock uses a laser tuned to the ytterbium transition. Scientists measure how many atoms remain in the lower, or ground, energy state and how many have moved into the higher, or excited, state. The balance between the two populations indicates whether the laser is still tuned to the atoms’ natural resonant frequency.

Once the laser is locked to that frequency, it serves as a practical stand-in for the atomic transition. Counting its oscillations provides the clock signal.


Comparing clocks at different elevations

To test gravitational time dilation, one ytterbium clock is operated in Boulder, Colorado, and another is taken to an observatory on Mount Blue Sky, at an elevation of 4,326 meters above sea level. The vertical separation is about 2.7 kilometers.

A clock at the higher elevation should run faster than the clock in Boulder. The predicted difference is approximately

2.885×10−13 seconds per second.2.885 \times 10^{-13}\ \text{seconds per second}.2.885×10−13 seconds per second.

This corresponds to roughly 25 billionths of a second per day.

The experiment tests the prediction by comparing the clocks’ signals over time. If their relative time offset changes at the rate predicted by general relativity, the clocks’ behavior agrees with the theory. A tiny difference in the measured slope could indicate a deviation, though the measurement must be precise enough to distinguish new physics from experimental error.

Operating a clock in a mountain observatory

The mountain clock must reproduce the essential operation of the laboratory clock while working in a much less controlled environment. The system includes the ytterbium oven, the vacuum chamber, and the lasers used to manipulate the atoms. The setup also has to contend with unstable weather, limited seasonal access, temperature variation, and insects that can interfere with the equipment.

Accurate elevation matters because the predicted gravitational effect depends on the clocks’ positions. Survey markers in the laboratory provide the altitude information needed to account for the clocks’ locations.


Transferring clock signals through the atmosphere

The mountain clock must be compared with the laboratory clock. A direct fiber-optic cable would be impractical over the required route, so the signal travels from the mountain through optical fiber to a transmitter and then across the atmosphere to a receiving station near Denver. The laboratory signal travels back along the link, allowing the two clocks to be compared.

The free-space part of the route is about 80 kilometers. A narrow laser beam must be aimed into a very small receiving target; the optical fiber’s core is only about 8 micrometers across. The beam also spreads as it travels, and atmospheric turbulence can make it less predictable. The signal is therefore both a precision measurement and a demanding pointing problem.

Why the link uses optical frequencies

A clock-comparison link needs to preserve enough information to determine the phase of the incoming signal—that is, where the wave is within its cycle. Atmospheric changes and detector imperfections introduce noise. The strength of the useful signal relative to this noise is called the signal-to-noise ratio.

A microwave signal has a much longer wavelength than visible light. If the phase can only be measured to within a small fraction of a wave, that fraction represents a much longer interval for a microwave than for an optical wave. The resulting timing uncertainty would be much larger, undermining the precision of an optical clock. For this reason, the signal must remain at optical frequencies.


Sending clock signals from moving platforms

A future extension is to compare a ground clock with one in space. Optical clocks have not generally been placed on the same moving platforms as traditional microwave clocks, so teams are testing the transfer system on vehicles, boats, and helicopters before using it with satellites.

A moving receiver is harder to target than a stationary one. The transmitter and receiver use beacon lasers to help locate one another, while the clock signal travels alongside the beacon. The ground terminal and airborne terminal perform reciprocal roles: each searches for and tracks the other’s beacon.

Atmospheric turbulence adds pointing errors. Pockets of warm air can deflect and move a laser beam. A fast tip-tilt mirror corrects these changes by adjusting the beam direction, in one described system at about 600 times per second.

Spatial and frequency matching

Pointing the two terminals at each other is only part of the challenge. Their lasers must also have nearly the same frequency. Optical systems have a very broad range of possible frequencies, so the two signals can be gigahertz or tens of gigahertz apart even when each is operating correctly. For a successful link, the frequencies must be brought within only a few megahertz.

The system therefore has to solve two distinct alignment problems:

  • Spatial alignment: the laser beams must reach their intended receivers.

  • Spectral alignment: the two optical frequencies must be close enough to establish a usable signal.

Helicopter trials demonstrated that the ground system could find an optical beacon on a moving platform and obtain brief periods of connection. Further engineering is needed for more reliable tracking and enough continuous data to compare clocks accurately. Such tests are stepping stones toward clock comparisons involving satellites.


Optical frequency combs: measuring extremely fast light

Even after an optical clock’s signal reaches a detector, a major problem remains: the signal oscillates too quickly for ordinary electronics to count directly. Optical frequencies can be hundreds of thousands of gigahertz, while even very fast electronic devices can switch only on the order of 10 billion times per second.

The solution is to compare the unknown optical frequency with a known reference and measure the much smaller difference between them.

Beat frequencies

When two signals of similar frequency overlap, they produce a slower variation called a beat frequency. For example, two tuning forks that are almost—but not exactly—at the same frequency create a pulsing sound at the difference between their frequencies. Light waves can also produce a beat signal when two lasers with nearby frequencies overlap.

If an unknown optical signal is close enough to a measurable reference, electronics can measure the beat frequency. The unknown frequency can then be calculated from the reference and the measured difference.

The difficulty is that the optical spectrum is extremely broad. A single reference laser is unlikely to land close enough to an arbitrary unknown optical frequency for its beat to be measurable. Scientists therefore needed many reference frequencies spread across the optical range.

How a frequency comb works

A frequency comb provides those reference frequencies. It is generated from very short laser pulses. In the frequency domain, the resulting light consists of many discrete, regularly spaced frequencies, like the teeth of a comb.

The spacing between the teeth is set by the pulse repetition rate. In a more complete description, the frequencies of the comb teeth are

fn=fceo+nfrep,f_n = f_{\mathrm{ceo}} + n f_{\mathrm{rep}},fn​=fceo​+nfrep​,

where frepf_{\mathrm{rep}}frep​ is the repetition rate, nnn identifies a comb tooth, and fceof_{\mathrm{ceo}}fceo​ is the carrier-envelope offset frequency. These parameters can be measured or locked to a known reference.

Because the teeth are evenly spaced and their positions are tied to measurable reference frequencies, a comb acts as a calibrated ruler extending from frequencies accessible to electronics into the optical range.

To determine an unknown optical frequency, scientists measure its beat with a nearby comb tooth. In simplified form, the unknown frequency is found by combining the known comb-tooth frequency with the measured beat frequency; the sign of the beat must also be identified. In a full comb measurement, the result accounts for the tooth number, repetition rate, offset frequency, and beat frequency.

Frequency-comb techniques made it possible to measure optical atomic clocks accurately. They turn an optical signal too fast for direct electronic counting into a set of measurable relationships with lower-frequency references.


Interpreting the gravity experiment

When the two optical clock signals are connected, their relative time offset changes gradually because the clocks run at different rates. The observed offset is compared with the predicted rate of gravitational time dilation.

To reduce the possibility of bias, the groups analyzing the clocks’ results keep their final digits hidden from one another until the analyses are ready to be compared. The goal is not merely to confirm the main predicted effect, but to search for a very small change in its measured slope. The sought-after deviation is described as being around one millionth of that already tiny slope.

The experimenters reported that they had no evidence contradicting general relativity, while noting that their data analysis was still underway. The intended precision approaches 10 parts per million for this kind of test, compared with about 100 parts per million for the best previous terrestrial test described in the source.

A result consistent with general relativity would confirm its prediction at a more sensitive level. A reproducible difference could suggest that the theory requires correction under those conditions. Either outcome contributes to understanding how gravity behaves and how it may ultimately connect with quantum mechanics.

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent