Maxwell’s Equations for Static Fields
Time-Varying Fields, Faraday’s Law, and Induced Electric Fields
Review: Static-Field Equations
A static field does not change with time. In electrostatics and magnetostatics, Maxwell’s equations reduce to four relationships:
Electric Gauss’s law: The divergence of electric flux density is the volume charge density:
∇⋅D=ρvElectrostatic curl equation: The curl of electric field intensity is zero:
∇×E=0This means the electrostatic field is conservative: its line integral around any closed path is zero, and the potential difference between two points does not depend on the path taken.
Magnetic Gauss’s law: The divergence of magnetic flux density is zero:
∇⋅B=0This expresses the absence of isolated magnetic monopoles: magnetic field lines do not begin or end at a single magnetic charge.
Magnetostatic Ampère’s law: The curl of magnetic field intensity is the current density:
∇×H=J
Static-field problems can also be expressed using Poisson’s equations for electric and magnetic potentials:
Electric scalar potential:
∇2V=−ϵρvMagnetic vector potential:
∇2A=−μJ
In charge-free and current-free regions, respectively, these reduce to Laplace’s equations:
Faraday’s Law of Electromagnetic Induction
Magnetic fields and induced electromotive force
A current in a conductor produces a magnetic field around it. This relationship motivated the complementary question: can a magnetic field produce a current? A constant magnetic field by itself does not induce a current in a stationary closed loop. Induction occurs when the magnetic flux linked to the loop changes.
The change produces an electromotive force (emf) around the loop. Despite its name, emf is not necessarily a mechanical force; it is the energy supplied per unit charge around a circuit and is measured in volts. An emf can drive charges around a closed conducting path, producing an induced current.
For a loop with magnetic flux Φ passing through it, the flux linkage for a coil with N turns is
where Ψ denotes flux linkage. Faraday’s law states that the induced emf is proportional to the rate of change of flux linkage.
Lenz’s law and the direction of induction
Lenz’s law specifies the direction of the induced emf. The induced effect acts so as to oppose the change in magnetic flux that produced it. Consequently, the induced emf is
For a coil of N turns, this can also be written as
The minus sign represents Lenz’s law. It does not mean that the induced emf always has a particular fixed direction; rather, its direction depends on whether the linked flux is increasing or decreasing. If the flux linkage changes more rapidly, the magnitude of the induced emf is greater. In a closed circuit, this emf can drive an induced current, which in turn produces its own magnetic field opposing the original change.
The Induced Electric Field
An electrostatic field is associated with charges at rest and is conservative. A time-varying magnetic flux, however, induces an emf around a closed loop. This indicates that an induced electric field accompanies the changing magnetic field.
For a conservative electrostatic field, the closed-path line integral is zero:
For the induced electric field, the closed-path integral is generally nonzero. It equals the induced emf:
Thus, the induced electric field is nonconservative: a charge can gain or lose energy while moving around a closed path in the field. The integral around a closed loop describes the emf; it should not be interpreted as an ordinary electrostatic potential difference between two locations.
Integral form of Faraday’s law
The magnetic flux through a surface S bounded by a closed curve C is
For a stationary loop and surface, Faraday’s law gives
Using Stokes’ theorem, which converts a closed line integral into a surface integral of the curl,
the local, differential form for a stationary circuit is
This equation states that a time-varying magnetic flux density produces a circulating electric field. If the magnetic field does not vary with time, the equation reduces to ∇×E=0, as in electrostatics.
Ways Magnetic Flux Through a Loop Can Change
Magnetic flux depends on the magnetic field passing through a loop and on the loop’s surface. Therefore, flux linkage can change in three general ways:
The magnetic field changes while the loop remains stationary.
A stationary loop may experience a changing flux if the magnetic flux density through its surface varies with time.The loop moves through a spatially varying magnetic field.
A loop moving from a region of stronger magnetic field to one of weaker field, or vice versa, can experience a change in flux even when the magnetic field itself is steady in time.Both the field and the loop’s position change.
Flux linkage changes when a time-varying field is encountered by a moving loop.
For a stationary loop, the change in flux is due to the changing field, and the differential form is ∇×E=−∂B/∂t. When the loop moves, the motion of charges through the magnetic field also contributes to the emf.
Motional Electric Field and Motional Emf
Magnetic force on moving charges
An electric field exerts a force on a charge q given by
A magnetic field exerts a force on a moving charge. For a charge moving with velocity u, this magnetic force is
A magnetic field does not exert this magnetic force on a charge at rest. In a moving conductor, however, charges move along with the conductor and can therefore experience the magnetic force.
Motional electric field
The force per unit positive charge defines an electric-field-like quantity. For charges moving with the conductor at velocity u through a magnetic field, the motional electric field is
This field describes the force on charges arising from the conductor’s motion through the magnetic field. It can contribute to an induced emf even when the magnetic field is not changing with time.
Combining field variation and motion
When both the magnetic field varies with time and the loop moves, the induced effects have two contributions:
A contribution from the time variation of the magnetic field.
A contribution from the loop’s motion through the magnetic field.
In the treatment of a moving loop, the electric-field-like terms combine as
The first term represents induction from a time-varying magnetic field. The second represents the contribution associated with motion. For a stationary loop, u=0, so only the first term remains. The standard Maxwell–Faraday field equation for a fixed observation point is
For a moving circuit, the motional contribution must also be included when calculating the circuit’s total emf.
Maxwell’s Equations for Time-Varying Fields
The electric Gauss’s law is unchanged when fields vary with time:
The electrostatic equation ∇×E=0 is replaced by Faraday’s law:
Together, these equations state that electric charge is a source of electric flux density, while a time-varying magnetic flux density produces a circulating electric field. The other two Maxwell equations also apply to time-varying fields; their complete time-varying forms include relationships describing how changing electric fields affect magnetic fields.