1. Home
  2. Explore
  3. Chemistry
  4. Electrode–Electrolyte Interface

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

Electrode–Electrolyte Interface

  • 53Unfamiliar
  • 0Learning
  • 0Familiar
  • 0Mastered
Topic: Double Layer

What happens when a metal electrode is immersed in an electrolyte, contributing to formation of the electrode–electrolyte double layer?

53 questions

  1. 1

    What happens when a metal electrode is immersed in an electrolyte, contributing to formation of the electrode–electrolyte double layer?

    1. A

      Ions of the same polarity accumulate in a single layer far from the metal

    2. B

      Water molecules transfer all their dipoles into the metal, leaving the liquid uncharged

    3. C

      Ions in the liquid adsorb on the metal, attracting nearby ions of opposite polarity

    4. D

      Electrons leave the metal and permanently remove every ion from the liquid

    Correct answer
    C

    Ions in the liquid adsorb on the metal, attracting nearby ions of opposite polarity

    Explanation

    Ions from the liquid can adsorb on the metal surface, and ions of opposite polarity gather nearby. These charge layers form the electrode–electrolyte double layer.

  2. 2

    Which ions define the inner Helmholtz plane (IHP) in the described double-layer model?

    1. A

      Ions located beyond the outer Helmholtz plane

    2. B

      Ions adsorbed directly on the electrode surface

    3. C

      Solvent molecules arranged far from the electrode

    4. D

      Ions distributed only in the bulk of the electrolyte

    Correct answer
    B

    Ions adsorbed directly on the electrode surface

    Explanation

    The IHP is the layer of ions adsorbed directly on the electrode surface.

  3. 3

    In the Helmholtz-plane description, where are ions of opposite polarity to the adsorbed ions represented?

    1. A

      Only in the inner Helmholtz plane, mixed with the adsorbed ions

    2. B

      Uniformly throughout the entire solvent, with no interfacial concentration

    3. C

      Near the adsorbed layer, in the outer Helmholtz plane

    4. D

      Only inside the metal, beyond the electrode surface

    Correct answer
    C

    Near the adsorbed layer, in the outer Helmholtz plane

    Explanation

    After ions adsorb at the electrode and form the IHP, ions of the opposite polarity come close to them and are represented in the outer Helmholtz plane.

  4. 4

    What does it mean that ions in a water-based electrolyte are normally solvated?

    1. A

      Water molecules surround the ions, with their dipoles oriented around them

    2. B

      The ions form a solid layer that contains no surrounding water molecules

    3. C

      The ions become part of the electrode and lose their electrical charge

    4. D

      The ions transfer their charge entirely to dissolved supporting salts

    Correct answer
    A

    Water molecules surround the ions, with their dipoles oriented around them

    Explanation

    Solvation means that water molecules surround the ions; the water dipoles are arranged around them.

  5. 5

    Which comparison of sodium and chloride ions matches the general charge-density trend described?

    1. A

      Cl−^-− has higher charge density than Na+^++

    2. B

      Neither ion has charge density because each has a single charge

    3. C

      Na+^++ has higher charge density than Cl−^-−

    4. D

      Na+^++ and Cl−^-− always have identical charge density

    Correct answer
    C

    Na+^++ has higher charge density than Cl−^-−

    Explanation

    The description identifies Na+^++ as small and having high charge density, while Cl−^-− has comparatively lower charge density. In general, it states that cations tend to have higher charge density than anions, while noting exceptions exist.

  6. 6

    How is the electrode–electrolyte double layer commonly represented in a simple electrical analogy?

    1. A

      As a battery that produces a fixed current without an interface

    2. B

      As a resistor that always allows electron transfer across the interface

    3. C

      As an inductor that stores charge only in the bulk electrolyte

    4. D

      As a capacitor called the double-layer capacitor

    Correct answer
    D

    As a capacitor called the double-layer capacitor

    Explanation

    The separated charges at the interface can be visualized like the charges on a capacitor, so the interface is often represented by a double-layer capacitor.

  7. 7

    What is a typical reported range for double-layer capacitance per unit electrode area?

    1. A

      101010 to 30 nF/cm230\,\text{nF}/\text{cm}^230nF/cm2

    2. B

      101010 to 30 μF/m230\,\mu\text{F}/\text{m}^230μF/m2

    3. C

      101010 to 30 μF/cm230\,\mu\text{F}/\text{cm}^230μF/cm2

    4. D

      101010 to 30 F/cm230\,\text{F}/\text{cm}^230F/cm2

    Correct answer
    C

    101010 to 30 μF/cm230\,\mu\text{F}/\text{cm}^230μF/cm2

    Explanation

    The stated typical double-layer capacitance is 101010 to 30 μF30\,\mu\text{F}30μF per square centimeter.

  8. 8

    If a potential difference of about 1 V1\,\text{V}1V occurs across a distance of 1 nm1\,\text{nm}1nm, what is the approximate electric-field magnitude?

    1. A

      1 GV/m1\,\text{GV/m}1GV/m

    2. B

      1 MV/m1\,\text{MV/m}1MV/m

    3. C

      1 GV/cm1\,\text{GV/cm}1GV/cm

    4. D

      1 V/m1\,\text{V/m}1V/m

    Correct answer
    A

    1 GV/m1\,\text{GV/m}1GV/m

    Explanation

    The field is approximately voltage divided by distance: 1 V/1 nm1\,\text{V}/1\,\text{nm}1V/1nm, or about 1 GV/m1\,\text{GV/m}1GV/m. This is a very large field over a very short distance.

  9. 9

    How does the Gouy–Chapman model differ from a description that confines charge separation to roughly the first nanometer?

    1. A

      It describes charge distribution extending roughly 10 nm10\,\text{nm}10nm from the electrode

    2. B

      It assumes that all charge separation occurs only inside the metal

    3. C

      It places every electrolyte ion at one fixed distance of 1 nm1\,\text{nm}1nm

    4. D

      It assumes that no charge distribution occurs near the electrode

    Correct answer
    A

    It describes charge distribution extending roughly 10 nm10\,\text{nm}10nm from the electrode

    Explanation

    The Gouy–Chapman model describes charge distribution over a distance of about 10 nm10\,\text{nm}10nm from the electrode, rather than limiting it to about 1 nm1\,\text{nm}1nm.

  10. 10

    What is the defining feature of the Stern model of the double layer?

    1. A

      It assumes that charge separation occurs only across the metal itself

    2. B

      It replaces all interfacial charge layers with a uniform bulk solution

    3. C

      It describes only adsorbed ions and excludes charge farther from the surface

    4. D

      It combines Helmholtz layers near the electrode with more extended charge distribution

    Correct answer
    D

    It combines Helmholtz layers near the electrode with more extended charge distribution

    Explanation

    The Stern model combines the Helmholtz-plane description with the Gouy–Chapman idea: some charge is close to the electrode, while some is distributed farther away.

  11. 11

    For an electrolyte concentration around 1 M1\,\text{M}1M, which description of charge distribution is generally appropriate according to the content?

    1. A

      Most charge separation occurs close to the electrode, so a Gouy–Chapman description may not be needed

    2. B

      The electrolyte concentration has no bearing on the charge-distribution model

    3. C

      All charge separation occurs over tens of micrometers, so a Stern model is required

    4. D

      Charge is distributed only in the bulk, so Helmholtz planes cannot form

    Correct answer
    A

    Most charge separation occurs close to the electrode, so a Gouy–Chapman description may not be needed

    Explanation

    At about 1 M1\,\text{M}1M electrolyte concentration, the charge separation is described as occurring mostly right next to the electrode, so the Gouy–Chapman model may not be necessary.

  12. 12

    When the electrolyte concentration is around 1 mM1\,\text{mM}1mM, which charge-distribution model may be a better choice?

    1. A

      A model that treats the interface only as a faradaic reaction

    2. B

      A model with no interfacial charge, because dilute solutions cannot form double layers

    3. C

      A model in which all ions are adsorbed directly onto the electrode

    4. D

      The Gouy–Chapman model, because charge distribution can extend farther from the electrode

    Correct answer
    D

    The Gouy–Chapman model, because charge distribution can extend farther from the electrode

    Explanation

    At around 1 mM1\,\text{mM}1mM, the content says the Gouy–Chapman model may be a better choice, consistent with charge being distributed farther from the electrode.

  13. 13

    What distinguishes an electrochemical reaction from a chemical reaction that involves no electron transfer?

    1. A

      An electrochemical reaction occurs only in water and never at an electrode

    2. B

      An electrochemical reaction changes concentration without any charge movement

    3. C

      An electrochemical reaction involves a chemical change together with electron transfer

    4. D

      An electrochemical reaction is defined by heat transfer rather than electron transfer

    Correct answer
    C

    An electrochemical reaction involves a chemical change together with electron transfer

    Explanation

    An electrochemical reaction includes a chemical reaction and electron transfer. Such a reaction gives rise to current.

  14. 14

    Which circuit element represents the double-layer charging behavior at an electrode?

    1. A

      The counter-electrode compliance voltage

    2. B

      The double-layer capacitance, CdlC_{\mathrm{dl}}Cdl​

    3. C

      The faradaic impedance, ZFZ_FZF​

    4. D

      The solution resistance, RsolR_{\mathrm{sol}}Rsol​

    Correct answer
    B

    The double-layer capacitance, CdlC_{\mathrm{dl}}Cdl​

    Explanation

    The double-layer capacitor, represented as CdlC_{\mathrm{dl}}Cdl​, models interfacial charge separation when no electrochemical reaction is being represented.

  15. 15

    What does faradaic impedance, denoted ZFZ_FZF​, represent in an electrochemical equivalent circuit?

    1. A

      Potential difference between the working and reference electrodes

    2. B

      Resistance of the metal electrode independent of the electrolyte

    3. C

      Impedance associated with current from an electrochemical reaction

    4. D

      Capacitance associated only with charge separation and no reaction

    Correct answer
    C

    Impedance associated with current from an electrochemical reaction

    Explanation

    The faradaic impedance ZFZ_FZF​ represents the impedance associated with an electrochemical, or faradaic, reaction and its current.

  16. 16

    How is an electrode modeled when both double-layer charging and an electrochemical reaction can occur?

    1. A

      A double-layer capacitor in series with the counter-electrode area

    2. B

      A solution resistance in parallel with a reference-electrode potential

    3. C

      A faradaic impedance in series with a capacitor that replaces the electrolyte

    4. D

      A double-layer capacitor in parallel with faradaic impedance

    Correct answer
    D

    A double-layer capacitor in parallel with faradaic impedance

    Explanation

    When a reaction is possible, the electrode model includes the double-layer capacitor and, in parallel, the faradaic impedance.

  17. 17

    In the simple two-electrode equivalent circuit, what does RsolR_{\mathrm{sol}}Rsol​ represent?

    1. A

      The impedance of the counter electrode during current control

    2. B

      The resistance of the electrode–electrolyte double layer alone

    3. C

      The resistance of the multimeter ground connection

    4. D

      The resistance offered by the electrolyte solution between the electrodes

    Correct answer
    D

    The resistance offered by the electrolyte solution between the electrodes

    Explanation

    The circuit places solution resistance, RsolR_{\mathrm{sol}}Rsol​, between the two electrodes to represent resistance offered by the electrolyte.

  18. 18

    Which combination describes the basic equivalent circuit for a two-electrode cell when both electrodes can support reactions?

    1. A

      Both electrodes are represented only by one shared CdlC_{\mathrm{dl}}Cdl​, with no solution resistance

    2. B

      The cell has a reference electrode in series with a single faradaic impedance

    3. C

      Each electrode has its own CdlC_{\mathrm{dl}}Cdl​ and ZFZ_FZF​, with RsolR_{\mathrm{sol}}Rsol​ between them

    4. D

      Each electrode has only RsolR_{\mathrm{sol}}Rsol​, with faradaic behavior assigned to the electrolyte

    Correct answer
    C

    Each electrode has its own CdlC_{\mathrm{dl}}Cdl​ and ZFZ_FZF​, with RsolR_{\mathrm{sol}}Rsol​ between them

    Explanation

    The described two-electrode model assigns a double-layer capacitance and faradaic impedance to each electrode, with solution resistance between the electrodes.

  19. 19

    Why can the potential of a single electrode not be measured directly with a voltmeter?

    1. A

      The electrode potential is always zero relative to the liquid

    2. B

      Connecting the meter to the electrolyte creates another interface with its own potential drop

    3. C

      A voltmeter measures current only, so it cannot measure any potential difference

    4. D

      The electrolyte blocks all electrical contact between the meter and the cell

    Correct answer
    B

    Connecting the meter to the electrolyte creates another interface with its own potential drop

    Explanation

    The probe connected to the electrolyte also forms an electrode–electrolyte interface, which has its own potential drop. The measured value therefore includes that additional contribution.

  20. 20

    If the desired electrode–liquid potential drop is xxx and the probe interface contributes a potential drop yyy, what can the meter measure in the described setup?

    1. A

      The value yyy alone

    2. B

      The sum x+yx+yx+y in every arrangement

    3. C

      The value xxx alone

    4. D

      The difference x−yx-yx−y

    Correct answer
    D

    The difference x−yx-yx−y

    Explanation

    The meter measures the potential difference between its two connections, so the result includes both interfaces; in the described sign convention it is x−yx-yx−y, not xxx alone.

  21. 21

    Why can an applied voltage across two electrodes fail to reveal the potential drop at either individual interface?

    1. A

      The applied voltage is always divided equally between the two interfaces

    2. B

      The total voltage is shared across interfaces and solution, and its distribution is not known from the total alone

    3. C

      The entire applied voltage must occur in the electrolyte solution

    4. D

      The potential drops at both interfaces are fixed at zero during measurement

    Correct answer
    B

    The total voltage is shared across interfaces and solution, and its distribution is not known from the total alone

    Explanation

    A measured terminal voltage is the combined result of potential drops at interfaces and possibly in the solution. The total does not identify how much occurs at each location.

  22. 22

    When the applied voltage in a two-electrode system is changed, what can generally be concluded about how the additional voltage is divided between the two interfaces?

    1. A

      Its division cannot be guaranteed; the changes at the interfaces may be unequal and unpredictable

    2. B

      It is always divided equally between the two interfaces

    3. C

      It always appears entirely at the interface with the larger electrode

    4. D

      It always appears entirely in the electrolyte solution

    Correct answer
    A

    Its division cannot be guaranteed; the changes at the interfaces may be unequal and unpredictable

    Explanation

    The content gives different possible distributions of a voltage change and explains that the change at each interface cannot be determined from the applied voltage alone.

  23. 23

    What is the key property of a reference electrode that makes it useful for measuring working-electrode potential changes?

    1. A

      Its potential drop changes in the same way as the working electrode's

    2. B

      It carries all the current generated by the working electrode

    3. C

      Its potential drop across its interface remains constant

    4. D

      It has no interface with the electrolyte and therefore no potential drop

    Correct answer
    C

    Its potential drop across its interface remains constant

    Explanation

    A reference electrode has a constant potential drop across its interface. Although its absolute drop is not measured directly, its stability makes changes at the working electrode interpretable.

  24. 24

    Why does a stable reference electrode allow a change in measured potential to be assigned to the working electrode?

    1. A

      Because all current is forced to pass through the reference electrode

    2. B

      Because the reference electrode eliminates the working electrode's double layer

    3. C

      Because the reference electrode makes the solution resistance exactly zero

    4. D

      Because the reference contribution stays constant, the change in potential occurs at the working electrode

    Correct answer
    D

    Because the reference contribution stays constant, the change in potential occurs at the working electrode

    Explanation

    If the reference-electrode potential drop remains constant, a change in the applied potential between it and the working electrode corresponds to a change at the working electrode.

  25. 25

    Which set contains only reference-electrode types named in the content?

    1. A

      SCE, Gouy–Chapman, and ZFZ_FZF​

    2. B

      SHE, SCE, and Ag–AgCl

    3. C

      SHE, platinum mesh, and RsolR_{\mathrm{sol}}Rsol​

    4. D

      IHP, OHP, and Cdl

    Correct answer
    B

    SHE, SCE, and Ag–AgCl

    Explanation

    The named reference electrodes are the standard hydrogen electrode (SHE), standard calomel electrode (SCE), and silver–silver chloride (Ag–AgCl) electrodes.

  26. 26

    How can an experiment's potential be compared or reproduced when different reference electrodes are used?

    1. A

      Report the reference electrode used and apply the appropriate constant potential offset

    2. B

      Convert the potential by multiplying it by the working-electrode area

    3. C

      Adjust the solution resistance until both reference electrodes have equal impedance

    4. D

      Use the same numerical potential without identifying the reference electrode

    Correct answer
    A

    Report the reference electrode used and apply the appropriate constant potential offset

    Explanation

    Potential values must be reported relative to a stated reference electrode. To reproduce a potential using another reference, a constant offset is applied.

  27. 27

    What is the purpose of positioning a reference electrode close to the working electrode, often with a Luggin capillary?

    1. A

      To make the reference electrode carry the cell's reaction current

    2. B

      To replace the working electrode's double-layer capacitance

    3. C

      To increase the distance through which current must pass in the electrolyte

    4. D

      To minimize the solution resistance between the working and reference electrodes

    Correct answer
    D

    To minimize the solution resistance between the working and reference electrodes

    Explanation

    A Luggin capillary allows the reference electrode tip to be placed close to the working electrode, reducing solution resistance between them.

  28. 28

    Why should the reference electrode have low impedance and carry little current?

    1. A

      Low impedance makes its potential drop vary rapidly with every small current

    2. B

      Its impedance determines the capacitance of the working electrode

    3. C

      Significant current through it can disrupt the constant potential drop that makes it a reference

    4. D

      High current through it is required to keep the working electrode at a stable potential

    Correct answer
    C

    Significant current through it can disrupt the constant potential drop that makes it a reference

    Explanation

    The reference electrode must maintain a constant potential drop. If significant current passes through it, it can lose this property; low impedance also makes its contribution small in the circuit.

  29. 29

    In a three-electrode system, which electrode primarily carries the current needed to balance current at the working electrode?

    1. A

      The counter electrode

    2. B

      The reference electrode

    3. C

      The Luggin capillary

    4. D

      The ground connection

    Correct answer
    A

    The counter electrode

    Explanation

    The counter electrode, also called the auxiliary electrode, supplies or takes up current so that significant current does not have to pass through the reference electrode.

  30. 30

    In a correctly operated three-electrode system, between which electrodes is the potential of interest measured?

    1. A

      Between the working electrode and the counter electrode

    2. B

      Between the counter electrode and the instrument ground

    3. C

      Between the counter electrode and the reference electrode

    4. D

      Between the working electrode and the reference electrode

    Correct answer
    D

    Between the working electrode and the reference electrode

    Explanation

    The working-electrode potential is measured with respect to the reference electrode. The counter electrode carries the cell current.

  31. 31

    Which statement best describes the counter electrode's role in a three-electrode system?

    1. A

      It carries the cell current while the reference electrode provides a stable potential measurement

    2. B

      It fixes the working-electrode area by acting as a reference surface

    3. C

      It measures the working-electrode potential while carrying no current

    4. D

      It eliminates all potential drop across the electrolyte

    Correct answer
    A

    It carries the cell current while the reference electrode provides a stable potential measurement

    Explanation

    The counter electrode takes up or supplies the current associated with the working electrode, while the reference electrode is used to measure working-electrode potential.

  32. 32

    Why is a counter electrode generally chosen to have a large area relative to the working electrode?

    1. A

      A larger area makes the working-electrode potential impossible to control

    2. B

      A larger area forces more current through the reference electrode

    3. C

      A larger area lowers the current density required to carry the cell current

    4. D

      A larger area increases the solution resistance between the electrodes

    Correct answer
    C

    A larger area lowers the current density required to carry the cell current

    Explanation

    For a given total current, a larger counter-electrode area means lower current density. This reduces the potential demand on the counter electrode and the load on the instrument.

  33. 33

    Why is platinum mesh often used as a counter electrode?

    1. A

      Platinum fixes the reference potential, and the mesh prevents current flow

    2. B

      Platinum is inert, and the mesh provides a large area for its geometric size

    3. C

      Platinum is highly reactive, and the mesh restricts its area

    4. D

      Platinum lowers the working-electrode capacitance, and the mesh increases solution resistance

    Correct answer
    B

    Platinum is inert, and the mesh provides a large area for its geometric size

    Explanation

    The content identifies platinum as an inert material and mesh as a structure that provides a large surface area for a given geometric area.

  34. 34

    What does the applied-voltage range of a potentiostat refer to?

    1. A

      The voltage between the counter and working electrodes

    2. B

      The current flowing between the reference and counter electrodes

    3. C

      The voltage between the reference and working electrodes

    4. D

      The resistance between the working electrode and the solution

    Correct answer
    C

    The voltage between the reference and working electrodes

    Explanation

    The applied voltage is the voltage controlled between the reference and working electrodes.

  35. 35

    What does the compliance-voltage range of a potentiostat refer to?

    1. A

      The potential drop across the double layer alone

    2. B

      The voltage between the reference electrode and instrument ground

    3. C

      The voltage between the reference and working electrodes

    4. D

      The voltage between the counter and working electrodes

    Correct answer
    D

    The voltage between the counter and working electrodes

    Explanation

    Compliance voltage describes the voltage between the counter and working electrodes that the instrument can provide while controlling the system.

  36. 36

    Why does a potentiostat need rapid, closed-loop control of the counter-electrode potential?

    1. A

      It must make the counter-electrode potential identical to the reference potential

    2. B

      It must keep the solution resistance higher than the interfacial impedance

    3. C

      It must adjust the counter electrode to take up the working-electrode current without exceeding its operating limits

    4. D

      It must ensure that the reference electrode carries all current at a fixed voltage

    Correct answer
    C

    It must adjust the counter electrode to take up the working-electrode current without exceeding its operating limits

    Explanation

    The counter-electrode potential must be adjusted in response to current so that the counter electrode can supply or take up the required current. The instrument's compliance limit must not be exceeded.

  37. 37

    Which measurement capability is especially important in a potentiostat used for electrochemical experiments?

    1. A

      Measurement of temperature instead of current or potential

    2. B

      Measurement of only large currents, with no need for precise potential control

    3. C

      Measurement of electrolyte concentration without sensing electrical current

    4. D

      Accurate measurement of very small currents, potentially down to picoamps

    Correct answer
    D

    Accurate measurement of very small currents, potentially down to picoamps

    Explanation

    The content notes that electrochemical instruments may need to measure currents in the microamp, nanoamp, or picoamp range accurately.

  38. 38

    Why is a three-electrode system generally preferred over a two-electrode system for electrochemical studies?

    1. A

      It makes every electrode interface behave as a fixed resistor

    2. B

      It separates stable potential measurement from the path carrying reaction current

    3. C

      It guarantees that no current passes through the electrolyte

    4. D

      It eliminates the need to control or measure the working-electrode potential

    Correct answer
    B

    It separates stable potential measurement from the path carrying reaction current

    Explanation

    A three-electrode system uses the reference electrode to control and measure working-electrode potential while the counter electrode carries the current. This avoids the main limitations of a two-electrode arrangement for electrochemical studies.

  39. 39

    In which situations does the content identify a two-electrode system as potentially adequate?

    1. A

      Experiments in which the reference electrode must carry the reaction current

    2. B

      Experiments where the electrolyte has no electrical conductivity

    3. C

      Electrical circuit analysis and some special cases

    4. D

      All electrochemical studies that require working-electrode potential control

    Correct answer
    C

    Electrical circuit analysis and some special cases

    Explanation

    The content says a two-electrode system can be adequate for electrical circuit analysis and some special cases, while electrochemical systems generally benefit from three electrodes.

  40. 40

    What current path is intended in a correctly operated three-electrode experiment?

    1. A

      Current flows between the working and counter electrodes, while potential is sensed using the reference electrode

    2. B

      Current flows between the reference and counter electrodes, while the working electrode senses voltage

    3. C

      Current flows only between the working and reference electrodes, with the counter disconnected

    4. D

      Current flows through the reference electrode, while the counter electrode senses voltage

    Correct answer
    A

    Current flows between the working and counter electrodes, while potential is sensed using the reference electrode

    Explanation

    The current passes between the working and counter electrodes. The reference electrode is used to measure working-electrode potential and should not carry significant current.

  41. 41

    What relationship is expected for an ideal resistor when potential is changed under fixed conditions?

    1. A

      Current changes linearly with potential, with V/I=RV/I=RV/I=R approximately constant

    2. B

      Current is determined only by electrode area, with no relation to V/IV/IV/I

    3. C

      Current changes independently of potential, while resistance is always zero

    4. D

      Current remains zero over a wide potential range and then suddenly increases

    Correct answer
    A

    Current changes linearly with potential, with V/I=RV/I=RV/I=R approximately constant

    Explanation

    For a resistor, Ohm's law gives V/I=RV/I=RV/I=R, which is generally constant under fixed conditions, although resistance can vary with temperature.

  42. 42

    How can a water-based electrochemical system differ from a simple resistor as the applied potential is varied?

    1. A

      It must show a linear current increase from zero potential onward

    2. B

      It may show little current over a substantial potential range before reactions become significant

    3. C

      It cannot carry current even when electrochemical reactions occur

    4. D

      It must have the same current at every potential within the water window

    Correct answer
    B

    It may show little current over a substantial potential range before reactions become significant

    Explanation

    The described water-based system can show no or very little current over a wide potential range, unlike the approximately linear response of a resistor.

  43. 43

    For the two-platinum-mesh salt-water example, approximately how wide is the range over which little or no current may be observed?

    1. A

      About 1.8 V1.8\,\text{V}1.8V

    2. B

      About 1.8 mV1.8\,\text{mV}1.8mV

    3. C

      About 18 V18\,\text{V}18V

    4. D

      About 180 V180\,\text{V}180V

    Correct answer
    A

    About 1.8 V1.8\,\text{V}1.8V

    Explanation

    The content describes a wide range of about 1.8 V1.8\,\text{V}1.8V with little or no current in the two-electrode salt-water example.

  44. 44

    What reactions explain the sharp current increase when water is driven beyond its usable potential window?

    1. A

      Metal deposition and dissolution without gas evolution

    2. B

      Hydrogen and oxygen evolution through water splitting

    3. C

      Carbon dioxide and nitrogen formation through solvent reduction

    4. D

      Sodium and chloride formation through salt precipitation

    Correct answer
    B

    Hydrogen and oxygen evolution through water splitting

    Explanation

    At sufficiently extreme potentials, water splitting occurs: hydrogen evolves at one electrode and oxygen at the other.

  45. 45

    Why must a researcher studying another reaction in a water-based electrolyte generally work within the water-stability window?

    1. A

      Outside the window, the reference electrode becomes a counter electrode

    2. B

      Inside the window, all faradaic reactions are thermodynamically impossible

    3. C

      Outside the window, hydrogen or oxygen evolution can become a competing reaction

    4. D

      Inside the window, the electrolyte has no ions and cannot carry current

    Correct answer
    C

    Outside the window, hydrogen or oxygen evolution can become a competing reaction

    Explanation

    Beyond the water window, hydrogen or oxygen evolution can occur, so experiments targeting other reactions are generally conducted within the range before water splitting becomes significant.

  46. 46

    How can choosing an electrode material such as zinc, lead, or mercury extend the practical potential window for studying another reaction?

    1. A

      These materials increase hydrogen-evolution kinetics so the desired reaction dominates

    2. B

      These materials eliminate the thermodynamic possibility of hydrogen evolution

    3. C

      These materials prevent oxygen evolution by removing all dissolved water

    4. D

      These materials can be poor catalysts for hydrogen evolution, slowing that competing reaction

    Correct answer
    D

    These materials can be poor catalysts for hydrogen evolution, slowing that competing reaction

    Explanation

    Zinc, lead, and mercury are described as relatively poor catalysts for hydrogen evolution. The resulting slow reaction rate can allow experiments to extend farther before hydrogen production becomes significant.

  47. 47

    What distinction between thermodynamics and kinetics is relevant to hydrogen evolution at different electrode materials?

    1. A

      Thermodynamics prevents hydrogen evolution, while kinetics sets the electrode area

    2. B

      Thermodynamics applies only to platinum, while kinetics applies only to zinc

    3. C

      Thermodynamics determines current density, while kinetics determines electrolyte concentration

    4. D

      Thermodynamics indicates whether hydrogen evolution is favored, while kinetics affects how quickly it occurs

    Correct answer
    D

    Thermodynamics indicates whether hydrogen evolution is favored, while kinetics affects how quickly it occurs

    Explanation

    The content distinguishes the thermodynamic expectation of hydrogen evolution from its rate: electrode materials can affect the kinetics and therefore the rate of hydrogen production.

  48. 48

    How can changing from an aqueous to a non-aqueous solvent affect the potential window?

    1. A

      It can extend the usable window, but the new solvent also has a breakdown voltage

    2. B

      It necessarily narrows the window to zero because no ions can dissolve

    3. C

      It guarantees an unlimited potential window because non-aqueous solvents cannot decompose

    4. D

      It removes the need to consider solvent reactions at any potential

    Correct answer
    A

    It can extend the usable window, but the new solvent also has a breakdown voltage

    Explanation

    Using a non-aqueous solvent can extend the potential window, but each solvent has a breakdown voltage beyond which it cannot be used.

  49. 49

    Which description best defines a supporting electrolyte?

    1. A

      A salt or acid added to increase conductivity without otherwise reacting in the system

    2. B

      A solvent added to prevent all ions from moving through the solution

    3. C

      A reagent added to drive the target electrochemical reaction to completion

    4. D

      A metal added to provide the working electrode with a larger surface area

    Correct answer
    A

    A salt or acid added to increase conductivity without otherwise reacting in the system

    Explanation

    A supporting electrolyte is a salt or acid chosen to increase conductivity without causing a change to the system through a reaction of its own.

  50. 50

    Which substance is given as an example of a supporting electrolyte?

    1. A

      Silver–silver chloride

    2. B

      Platinum mesh

    3. C

      Hydrogen gas

    4. D

      Sodium perchlorate

    Correct answer
    D

    Sodium perchlorate

    Explanation

    Sodium perchlorate is given as an example of a supporting electrolyte.

  51. 51

    How does adding a substantial amount of supporting electrolyte affect solution resistance?

    1. A

      It decreases conductivity and makes solution resistance dominate

    2. B

      It converts solution resistance into faradaic impedance at the reference electrode

    3. C

      It increases conductivity and can make solution resistance negligible

    4. D

      It leaves conductivity unchanged but removes the double-layer capacitance

    Correct answer
    C

    It increases conductivity and can make solution resistance negligible

    Explanation

    Supporting electrolyte increases conductivity. With enough of it, solution resistance can become negligible in the described circuit model.

  52. 52

    In a low-conductivity electrolyte, where can a significant portion of the applied potential drop occur during a reaction?

    1. A

      Entirely across the instrument's voltage display

    2. B

      Only across the reference electrode, regardless of its position

    3. C

      Only inside the counter-electrode metal

    4. D

      Across the electrolyte solution between the electrodes

    Correct answer
    D

    Across the electrolyte solution between the electrodes

    Explanation

    When conductivity is low, current through the solution can produce a significant potential drop in the electrolyte, so not all of the applied change occurs across the working-electrode interface.

  53. 53

    Why is supporting electrolyte useful when interpreting potential changes at the working electrode?

    1. A

      By eliminating the double layer, it prevents all interfacial potential changes

    2. B

      By increasing solution resistance, it ensures the entire potential drop is in the bulk

    3. C

      By carrying current through the reference electrode, it fixes the working potential

    4. D

      By reducing solution resistance, it helps concentrate the potential drop at the electrode interface

    Correct answer
    D

    By reducing solution resistance, it helps concentrate the potential drop at the electrode interface

    Explanation

    Increasing conductivity reduces solution resistance and its associated potential drop. This helps ensure that changes in potential occur mainly across the electrode interface being studied.

Question 1 of 53
Question 1 of 53

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent