Consider the two-span highway bridge shown here. We wish to determine the maximum reaction force, shear force, and bending moment that develop in the structure due to a combination of permanent and transient loads. As you can see, the bridge deck rests on four identical girders. For this analysis, we assume that the bridge loads are distributed equally among the girders. So our task is to determine the extreme effect of the applied loads on a typical girder.

Generally speaking, bridges are designed to carry permanent and transient loads. For example, the weight of the bridge deck is considered a permanent load, it is not going to change significantly during the life of the structure. On the other hand, vehicles exert transient loads on the bridge. such a load changes position and magnitude as a function of time. In this lecture, we are going to consider two permanent loads: the weight of the bridge deck, and the self weight of the girder. For transient load, we are going to use a widely accepted load pattern given by the American Association of State Highway and Transportation officials (AASHTO) referred to as HL-93. Let's start by calculating the permanent loads.

The bridge deck is made of reinforced concrete having an average specific weight of 25 kN/m^3. The deck has a width of 14 m. Let's assume an average thickness of 0.3 m for a typical deck cross-section. Therefore, the weight per linear meter of the deck is 105 kN. This weight is to be distributed equally among the 4 girders, which means each girder carries a uniformly distributed load of 26.25 kN/m. For this analysis, we are going to assume that the cross-sectional area of each girder is: 90000 mm^2, or 0.09 m^2. Assuming a specific weight of 78 kN/m^3 for steel, the self weight of each girder, viewed as a uniformly distributed load, becomes 7.02 kN/m. Therefore the total permanent load, uniformly distributed over a typical girder is 33.27 kN/m.

For transient loading, per AASHTO HL-93 specifications, we need to consider 3 types of loads: a uniformly distributed load and 2 concentrated loads. The uniformly distributed load represents a series of hypothetical vehicles moving in tandem. The magnitude of this load is 9.3 kN/m. We call it Design Lane Load. In addition to a distributed load, HL-93 provides two sets of concentrated loads. one is called Design Truck Load, and the other is referred to as Designed Tandem Load. The Design Truck Load consists of 3 concentrated loads, one load for each axle of a hypothetical three-axle truck. The load at the front axle is 35 kN in magnitude. The other two loads are 145 kN each.

The other concentrated load pattern, the Design Tandem Load, consists of two concentrated loads. Each load has a magnitude of 110 kN. In applying the transient loads to the bridge, as you will see in a minute, we need to determine the load combination that produces the maximum internal force in the structure. In this lecture, we are interested in determining the maximum support reaction, the maximum shear force, and the maximum positive and negative moments in a typical girder.

Let's focus on this girder. There is a pin connection here, a roller support here, and a roller here. The splice at this point is assumed to act as an internal hinge. The relevant dimensions of the beam are: We are going to start by determining the maximum support reaction in the beam due to the permanent and transient loads. First, let's draw the reaction influence line for each support. If you are not sure how to draw the needed influence lines, please review lectures SA16 through SA18, in which we've offered an in-depth discussion on the construction of reaction, shear, and moment influence lines. Here is the influence line for the reaction force at A.

For the reaction force at B the influence line looks like this: And this diagram represents the influence line for the reaction force at C. We are going to use these diagrams to calculate the 3 reaction forces due to the permanent and transient loads. Let's take these diagrams one at a time. Using basic geometry, we can determine height h. Note the two similar triangles here. Since they share the same angle, we can equate their height to base ratios, like this: Solving this equation for h, we get:

Now we have all the information that we need in order to determine the reaction force at A due to the permanent and transient loads Let's take the permanent load first. A few minutes ago, we determined the magnitude of the uniformly distributed load due to the weight of the concrete and steel. It equals 33.27 kN/m. If we multiply this number by the area under the influence line, we get the reaction force at A due to the applied load. Note that the influence line defines three distinct areas.

This area is that of a right triangle with base 9 and height 1. It equals 4.5 since the diagram is drawn above the x-axis, we denote it as a positive area. This small area equals -0.5 And this one equals -2. These are considered negative areas, since the influence line for this segment of the beam falls below the x-axis. If we multiply the permanent load magnitude by the algebraic sum of these areas, we get:

So the reaction force at A due to the permanent load equals 66.54 kN. To determine the reaction force at B, we can multiply the magnitude of the load by the area under this influence line. To calculate the area, we need to determine this height. Height h can be calculated by equating the height to base ratio of the bigger triangle to that of the smaller one, like this: So, h = 4/3. Therefore, the area of the triangle equals 16.

Now the reaction force at B can be computed by multiplying 33.27 by 16. The force equals 532.32 kN. Using the same strategy, we can determine the reaction force at C. The area under the influence line here equals positive 6. Therefore, the reaction force at C equals 199.62 kN. By comparing these values, we can conclude that the maximum reaction force in the beam occurs at B.

However, we are not done yet. We need to include the effect of the transient load on the support reactions. As we saw a few minutes ago, AASHTO HL-93 gives us 3 transient loads. The Design Lane Load, the Design Truck Load, and the Design Tandem Load. For design purposes, we need to consider two load combinations: Lane Load + Truck Load, and Lane Load + Tandem Load The load combination that produces the maximum reaction force governs the design. Let's consider this combination first.

Before we proceed with the analysis, we need to make an assumption. Since the bridge deck rests on four girders, and each traffic lane is supported by two girders, we assume that each girder carries half of the transient load. Therefore, we need to divide these load magnitudes in half in order to arrive at the design loads that act on a single girder. Let's place the loads on the beam one at a time and calculate the maximum support reaction that results.

To facilitate the analysis, we are going to use the 3 influence lines that we have constructed already. The maximum reaction force at A can be attained by placing the distributed load over the part of the beam that corresponds to this positive area. The product of this area by the magnitude of the load gives us the reaction force at A due to the load. Similarly, if we stretch the distributed load over the part of the beam that corresponds to this entire positive area, we get the maximum reaction force at support B.

To determine the maximum reaction force at C, we need to place the load over this area. A qualitative comparison of these 3 diagrams reveals that the reaction force at support B is going to be larger than the reaction force at support A or C. Why? Because the influence line for the reaction force at B has the largest positive area. We can perform the same type of qualitative analysis for the concentrated loads. For the Design Truck Load given by AASHTO HL-93, the two front axles of the truck are separated by 4.3 m, and the rear axles can be set apart by 4.3 to 9 m. Our task is to determine the trucks location and configuration that causes the reaction force at B to reach its maximum value.

So which of these scenarios is going to give us the largest reaction force? If the truck is placed here, here, or here? For each scenario, we need to multiply each concentrated load by the height of the influence line under the load. We then add up the three resulting values to get the magnitude of the reaction force. Given the shape of this influence line, it should be obvious that the support reaction that B is going to be larger than the reaction force at A or C. So, this is the governing loading scenario.

That is, for determining the maximum reaction force in the beam, we can safely ignore the reactions at A and C and focus solely on the reaction force at B. The area under the influence line for the reaction force at B equals 16. If we multiply 4.65 by 16, we get the maximum reaction force due to the Design Lane Load.

For the Design Truck Load, when the truck assumes this position, the three concentrated loads cause the maximum reaction force to develop at support B. This reaction force can be calculated by multiplying the magnitude of each concentrated load by the height of the influence line under the load. The height of the influence line under the front load can be determined using basic geometry. Note that the distance between the load and the right end of the beam is 7.7 m.

Therefore, height h can be determined like this: Similarly, we can determine height g like this: Now, we can compute the reaction force as shown here: AASHTO HL-93 indicates that multiple trucks can be present on the beam, as long as the tail-to-nose distance between two consecutive trucks is not less than 15 m.

However, our short-span bridge cannot accommodate more than one full truck at a time. Therefore, the maximum reaction force due to the Design Truck Load equals 173.67 kN. Let's summarize what we have done so far. 1. We have determined that the maximum reaction force in the beam occurs at support B. 2. We have calculated the reaction force at B due to the permanent load.

3. We have computed the reaction force at B due to the Design Lane Load. and 4. We have calculated the reaction force at B due to the Design Truck Load. The combined lane and truck loads, therefore, gives a reaction force of 248.7 kN at support B. Now we need to calculate the reaction force at B due to the Design Tandem Load, and to decide which load combination governs the design: Lane Load + Truck Load or Lane Load + Tandem Load.

Per AASHTO HL-93 specifications, the Design Tandem Load consists of two concentrated loads 1.2 meter apart. The magnitude of each load, per girder, equals 55 kN. To determine the maximum effect of the load on the reaction force at B, we can place the Truck Load like this: The resulting reaction force is 139.33 kN. Although AASHTO HL-93 does not specify a minimum distance between trucks for this loading, we can assume a practical distance for separating two consecutive trucks, say, 10 m. This means we can place three such trucks on the bridge, like this:

As you can see, the trucks are placed such that the distance between their closest concentrated loads is 10 m. Using the law of similar triangles, we can determine the needed heights of the influence line. Consequently, the reaction force at B due to the Design Tandem Load becomes: Since this value is lower than the reaction force caused by the Design Truck Load, the governing transient load for calculating the maximum reaction force in the bridge is the combination of the Design Lane Load and Design Truck Load.

This combination gives us a reaction force of 248.07 kN at support B. We need to combine the permanent and transient loads using specific load combination equations. For HL-93 loading, we can use this equation: Therefore, the absolute maximum design reaction force in the bridge, which takes place at support B, equals 1099.52 kN.

Let's turn our attention to shear force analysis. Suppose we wish to determine the maximum shear force that could develop at the internal hinge. We start by drawing the influence line for the shear force at the hinge. This diagram can be used to calculate our target maximum shear force due to the permanent and transient loads. The permanent uniformly distributed load has a magnitude of 33.27 kN/m. The area under the influence line equals 6.

Therefore, the shear force at D due to the load equals 199.62 kN. For the Design Lane Load, we place the uniformly distributed load of 4.65 on the part of the beam associated with the positive area under the influence line. The resulting shear force, therefore, equals 27.90 kN. The Design Truck Load, when placed on the bridge like this, results in the largest possible shear force at the hinge. Knowing the position of each concentrated load, we can easily calculate the height of the influence line under the middle and front loads. Hence, the shear force due to the Design Truck Load can be computed as shown here:

Finally, to determine the contribution of the Design Tandem Load to the shear force at D, we place the load on the beam for the maximum effect. The height of the influence line under this concentrated load equals 0.9 The resulting force, therefore, equals 104.50 kN. In summary, under the permanent load, the shear force at D equals 199.62 kN. The Lane Load produces a force of 27.90 kN. The Truck Load gives us a force of 123.97 kN. And, the Tandem Load yields a force of 104.50 kN. Compared to the Design Tandem Load, the Design Truck Load produces a larger shear force at D. Therefore, we are going to use it to calculate the total shear force due to the transient load. Finally, using the load combination equation, we can calculate the maximum design shear force at the hinge. It equals 515.30 kN.

To determine the maximum positive moment in the beam, we start by applying basic qualitative reasoning to the problem. Knowing that for this beam maximum positive moment occurs at the mid-span, we can conclude that bending moment reaches its maximum value either at point E or at point F. To decide which point is going to be subjected to a more critical bending moment, we are going to use moment influence lines. Here is the influence line for the bending moment at E.

And here is the influence line for the moment at F. Please review Lecture SA18 if you are not sure how these diagrams are drawn. Since we are interested in the maximum positive bending moment only, we are going to focus on the positive areas under the influence lines. To be able to accurately compare the areas, we need to know the peak values at E and F. The peak value at E represents the magnitude of the bending moment at E when the beam is subjected to a unit load placed at E. So let's compute that value. We place a load at E,

isolate segment AD, and draw its free-body diagram. Since the load unit is placed halfway between the two reaction forces, they must be equal in magnitude. Therefore, the bending moment at E equals 2.25 That is, the height of the influence line at E is 2.25 Note that we can also determine height h. The ratio of the height to base of this triangle equals to the height to base ratio of this smaller triangle. Therefore, we can write: So, h equals 1.5 We can determine this height in a similar manner. The height represents the bending moment at F when a unit load is placed at F. Here is the free-body diagram of segment DC.

Here too, the two reaction forces are going to have the same magnitude. Therefore, the bending moment at F can be calculated like this: So the height of this influence line at F equals 3. Knowing the heights, we can calculate the area under each influence line. This area equals positive 10.125 This area is negative 11.25 And for this area, we get positive 18.

Since this influence line has the largest positive area, we conclude that bending moment in the beam reaches its maximum value at point F. To calculate that value, we are going to load the beam with the permanent and transient loads. The permanent load has a magnitude of 33.27 kN/m. The area under the influence line is positive 18. This results in a bending moment of 598.86 kN-m.

The intensity of the Design Lane Load is 4.65 kN/m. To get the maximum effect from this load, we place it over segment DC. The resulting bending moment magnitude is 83.7 kN-m. To maximize the resulting bending moment due to the Design Truck Load, we place the load on the beam, like this: Since we know all the relevant distances in this triangle, we can easily determine the height under the two outer loads. It equals 0.85 Therefore, the moment at F due to the load can be computed as shown here: And, when we place the Tandem Load on the beam like this: We get 297 kN-m for bending moment at F.

Here is a summary of the computed positive bending moments at F. Since the moment due to the Tandem Load is larger than the moment due to the Truck Load, we compute the total bending moment due to the transient load by combining the lane load and tandem load moments. Finally, using the load combination equation, we can determine the maximum positive bending moment in the beam. It equals 1414.8 kN-m.

To determine the maximum negative moment in the beam, first we need to decide where the moment takes place. There are two candidate points at which negative moment could reach its maximum value: point E, and point B. We constructed the influence line for point E a minute ago, here it is: This negative region tells us that when the load is placed on segment BC, bending moment at E is going to be negative.

A negative bending moment also develops at point B. Let's draw the influence line for it. To compare the two influence lines, we need to know this height. To determine the height, we are going to place a unit load at D. Then, calculate the bending moment that results at B. To calculate the internal moment at B, we can isolate segment AD, and draw its free-body diagram. We are looking for this bending moment, which can be determined easily by multiplying this force by this distance. The bending moment equals 3, which means this height is 3.

Therefore the area of this triangle equals -22.5 Since this area is larger than this one, we can conclude that the largest negative moment in the beam occurs at point B. To determine the magnitude of that moment, we need to load the beam with the permanent and transient loads. The permanent load has a magnitude of 33.27 kN/m. The area under the influence line is -22.5 This results in a bending moment of -748.58 kN-m at point B. The intensity of the Design Lane Load is 4.65 kN/m. To get the maximum effect from this load, we place it over segment BC. The resulting bending moment is -104.63 kN-m

To maximize the effect of the Design Truck Load on the bending moment at B, we place the load on the beam like this: Since we know all the relevant distances in this triangle, we can easily determine these two heights under the influence line. The bending moment at B due to the Truck Load can be computed as shown here: To get the extreme effect for the Tandem Load, we place it on the beam like this: After determining this height, we can compute the bending moment at B as shown here:

Note that a second truck can be placed on the beam, like this: The resulting bending moment at B due to this additional load equals -11 kN-m The total negative moment at B due to the Tandem Load, therefore, equals -324.5 kN-m Here is a summary of the computed negative bending moments at B. Since the bending moment due to the Truck Load is larger than the moment due to the Tandem Load, we compute the total moment due to the transient load by combining the Lane Load and Truck Load moments.

Then, using the load combination equation, we determine the maximum negative design bending moment in the beam. It equals 1770 kN-m In conclusion, for our short-span bridge, the maximum reaction force develops at the interior support. It equals 1100 kN per girder. The maximum shear force at the hinge, per girder, equals 515 kN.

The maximum positive moment takes place 6 m away from the right end of the bridge. The magnitude of that moment in each girder is 1415 kN-m And, the maximum negative moment occurs at the interior support. Each girder should be designed to accommodate a negative moment of 1770 kN-m at that support.