Bridge Load Analysis


Bridge Load Analysis

Maria
Today we’re analyzing a two-span highway bridge to find the largest support reaction, shear force, and positive and negative bending moments caused by permanent and moving loads. The deck rests on four identical girders, and we’ll assume the loads are shared equally, so we can analyze one typical girder.

Michael
That distinction between permanent and transient loads is important. The deck and the girder’s own weight are permanent loads because they remain essentially constant. Vehicle loads are transient: their positions and magnitudes on the bridge change over time.

Maria
Let’s calculate the permanent load first. The reinforced-concrete deck has a specific weight of 25 kilonewtons per cubic meter, a width of 14 meters, and an average thickness of 0.3 meters. Multiplying those values gives 105 kilonewtons per meter of bridge.

Michael
And because four girders share that deck load equally, each girder carries 105 divided by four, or 26.25 kilonewtons per meter. We also include the girder’s own weight: its area is 0.09 square meters, and steel weighs 78 kilonewtons per cubic meter, giving 7.02 kilonewtons per meter.

Maria
So the total permanent uniformly distributed load on one girder is 26.25 plus 7.02, which is 33.27 kilonewtons per meter. That load will act along the girder when we calculate its effects.

Michael
For transient loading, we use the AASHTO HL-93 pattern. It includes a Design Lane Load, representing a stream of vehicles, plus a choice between a Design Truck Load and a Design Tandem Load. The lane load is 9.3 kilonewtons per meter for the lane, and the truck and tandem are concentrated-load patterns.

Maria
The Design Truck has three axle loads: 35 kilonewtons at the front and 145 kilonewtons at each of the two rear axles. The front and first rear axles are 4.3 meters apart; the spacing between the rear axles can vary from 4.3 to 9 meters. The Design Tandem has two 110-kilonewton loads spaced 1.2 meters apart.

Michael
For this bridge, each traffic lane is supported by two girders, so we assign half of each transient lane load and vehicle load to the girder we’re analyzing. That makes the lane load 4.65 kilonewtons per meter, each tandem load 55 kilonewtons, and the truck axle loads 17.5, 72.5, and 72.5 kilonewtons.

Maria
The girder has a pin at A, rollers at B and C, and an internal hinge at the splice, point D. Influence lines let us track how a moving load affects a particular response. For a distributed load, we multiply its intensity by the relevant signed area under the influence line; for a point load, we multiply its magnitude by the influence-line height at its position.

Michael
And when a load can move, we place it where it produces the greatest effect of interest. Positive and negative portions of an influence line matter differently: for a maximum positive response, we load the positive region; for a maximum negative response, we load the negative region.

Maria
Let’s start with the support reactions. For reaction A, the influence line has a positive triangular area of 4.5, followed by negative areas of 0.5 and 2. Its signed total is 4.5 minus 0.5 minus 2, or 2. Multiplying by the permanent load of 33.27 gives a reaction of 66.54 kilonewtons at A.

Michael
For reaction B, similar triangles give a peak height of four-thirds, and the influence-line area is 16. So the permanent-load reaction there is 33.27 times 16, or 532.32 kilonewtons. At C, the influence-line area is positive 6, giving 33.27 times 6, or 199.62 kilonewtons.

Maria
That already tells us that the permanent load creates its largest support reaction at B. We still need to test the transient loads, though, and the governing reaction may depend on how the moving loads are placed.

Michael
For the lane load, the reaction influence line at B has the largest positive area, so B is the support to focus on. We place the lane load over that positive region, whose area is 16. The resulting reaction is 4.65 times 16, or 74.4 kilonewtons.

Maria
We can make the same comparison for the truck: multiply each axle load by the influence-line height beneath it, then add the three contributions. The truck position that maximizes the reaction at B gives 173.67 kilonewtons. The short bridge cannot accommodate more than one full truck at a time, even though HL-93 allows multiple trucks when the tail-to-nose spacing is at least 15 meters.

Michael
The tandem also needs to be checked. A single tandem placed for maximum effect gives a reaction of 139.33 kilonewtons at B. The analysis also considers tandem groups with a practical 10-meter separation; even with that placement, the tandem reaction remains below the truck’s 173.67 kilonewtons.

Maria
So the governing transient combination for the support reaction is lane load plus truck load: 74.4 plus 173.67 equals 248.07 kilonewtons at B. Combining that with the permanent reaction using the stated design factors—1.25 on permanent load and 1.75 on transient load—gives 1.25 times 532.32 plus 1.75 times 248.07, or about 1,099.52 kilonewtons.

Michael
That’s the maximum design reaction per girder, and it occurs at the interior support B. The key steps were identifying the critical support from the influence lines, positioning each transient load for maximum effect, and then combining the governing transient case with the permanent load.

Maria
Next is shear at the internal hinge D. Its influence line has a signed area of 6, so the permanent load produces 33.27 times 6, or 199.62 kilonewtons of shear.

Michael
For the lane load, we cover the positive part of the hinge’s shear influence line. The resulting shear is 27.90 kilonewtons. For the truck, the critical placement puts the axles where they produce the largest combined influence-line contribution; that gives 123.97 kilonewtons.

Maria
The tandem’s critical placement gives 104.50 kilonewtons of shear at D. Since 123.97 is greater than 104.50, the truck governs over the tandem for this response. So the transient shear combination is lane load plus truck load.

Michael
Applying the design factors, we get 1.25 times the permanent shear of 199.62, plus 1.75 times the transient shear of 27.90 plus 123.97. That gives a maximum design shear at the hinge of 515.30 kilonewtons per girder.

Maria
Now let’s find the maximum positive bending moment. Qualitatively, the likely locations are the mid-span points E and F, so we compare their moment influence lines. At E, the peak influence-line height is 2.25; at F, it is 3.

Michael
The positive and negative areas help us make the comparison. At E, the positive area is 10.125 and the negative area is minus 11.25. At F, the positive area is 18. Since we’re looking for the greatest positive moment, F is the more critical point.

Maria
The permanent load acting over F’s influence line gives 33.27 times 18, or 598.86 kilonewton-meters. For the lane load, we cover the positive influence-line region on segment DC, giving 4.65 times 18, or 83.7 kilonewton-meters.

Michael
For the truck, we position the axles to maximize their combined contributions at F, using the influence-line heights beneath them. The tandem is positioned the same way for its own maximum effect and gives 297 kilonewton-meters. Since that exceeds the truck contribution, the governing transient combination for positive moment is lane load plus tandem load.

Maria
The design positive moment is therefore 1.25 times 598.86, plus 1.75 times the transient total of 83.7 plus 297. The result is 1,414.8 kilonewton-meters per girder. This maximum positive moment occurs at F, 6 meters from the right end of the bridge.

Michael
For the maximum negative moment, the candidates are E and the interior support B. The influence line at E does show a negative region when loads are on segment BC, but we need to compare its negative area with the influence line at B.

Maria
To establish the needed height for B’s influence line, place a unit load at D and calculate the resulting moment at B from the free-body diagram of segment AD. That moment is 3, which sets the influence-line height. The negative triangular area at B is minus 22.5, larger in magnitude than the negative area at E, so B governs.

Michael
The permanent load’s contribution at B is 33.27 times minus 22.5, or minus 748.58 kilonewton-meters. For the lane load, placing it over segment BC produces minus 104.63 kilonewton-meters.

Maria
We then position the truck to maximize the negative moment at B and calculate each axle’s contribution from the influence-line height under it. The tandem is positioned for its own extreme effect as well; the analysis includes an additional truck in the tandem case, giving a total tandem contribution of minus 324.5 kilonewton-meters.

Michael
In this comparison, the truck produces a larger negative moment than the tandem, so the governing transient combination is lane load plus truck load. Applying the design factors to the permanent and transient contributions gives a maximum negative design moment of about minus 1,770 kilonewton-meters per girder at support B.

Maria
Let’s recap the results for one girder. The maximum design support reaction is about 1,100 kilonewtons at the interior support. The maximum design shear at the internal hinge is 515 kilonewtons.

Michael
And the maximum positive design moment is 1,415 kilonewton-meters at F, 6 meters from the right end. The maximum negative design moment is 1,770 kilonewton-meters at the interior support. Together, the influence lines and the load combinations show both where each extreme occurs and which transient load pattern governs it.

Ask anything
We've read this whole study set, so questions about it get the best answers.