Centrifugal Pump Performance
Centrifugal Pumps and Pump-System Operation
1. Centrifugal Pump Fundamentals
A centrifugal pump is a common radial-flow pump used in applications such as swimming pools, spas, water-supply systems, and many industrial fluid systems.
Its primary purpose is to increase the pressure and energy of a fluid.
Main components and flow directions
Impeller: A rotating set of blades inside the pump. The impeller transfers energy to the fluid.
Suction side: The side where fluid enters the pump.
Discharge side: The side where fluid leaves the pump at a higher pressure.
Motor: Supplies mechanical power to the pump.
Shaft coupling: Connects the motor shaft to the pump shaft.
Torque meter: Measures the torque transmitted through the shaft.
Tachometer: Measures the rotational speed of the pump shaft.
Pressure taps or gauges: Measure pressure before and after the pump.
Flow meter: Measures the volumetric flow rate, Q.
The impeller rotates and throws the fluid outward in a radial direction. This outward motion, together with the pump casing, produces an increase in fluid pressure.
A centrifugal pump converts mechanical shaft power into hydraulic energy, primarily by increasing the fluid pressure and total head.
2. Centrifugal Pump Testing
Engineers test pumps to determine how much head, power, and efficiency the pump can provide at different flow rates.
A typical laboratory setup contains:
A large water reservoir
A centrifugal pump
A closed piping circuit that returns water to the reservoir
A flow meter
Pressure measurements at the suction and discharge sides
A motor and shaft coupling
Torque and rotational-speed measurements
The pump is generally tested at a constant rotational speed while the flow rate is varied. A valve in the piping system can be adjusted to produce different flow rates.
For each operating condition, the test can provide:
Flow rate, Q
Pressure rise across the pump
Pump head, HP
Shaft torque
Shaft rotational speed, ω
Shaft power
Pump efficiency
These measurements are then used to construct pump-performance curves.
3. Energy Equation Across a Pump
Consider point 1 on the suction side and point 2 on the discharge side. Applying the mechanical energy equation from point 1 to point 2 gives
where:
P is pressure
γ is the specific weight of the fluid
V is average flow velocity
g is gravitational acceleration
z is elevation
HP is the head added by the pump
hL is the head loss between points 1 and 2
The pressure terms are often expressed as pressure head:
Simplifications for pressure taps near the pump
In a pump test, the pressure taps are usually located very close to the pump. Therefore:
The change in elevation, z2−z1, is usually very small.
The lengths of straight pipe between the pressure taps and the pump are minimal.
The velocity heads at the two measurement locations are often approximately equal.
The piping losses between points 1 and 2 are usually neglected.
Under these assumptions,
Thus, the pump head is approximately equal to the pressure rise across the pump divided by the fluid specific weight.
Because of the pump’s function,
Continuity
For steady flow through the pump, conservation of mass requires
If the pipe diameter is approximately the same at the suction and discharge pressure taps, the average velocities are also approximately equal.
4. Pump Performance Curves
A pump-performance curve describes how a pump behaves as the flow rate changes.
The primary performance curve plots:
Vertical axis: Pump head, HP
Horizontal axis: Volumetric flow rate, Q
Typical pump-head curve
At a fixed pump speed, the pump head generally behaves as follows:
At zero flow, the pump produces its maximum head.
The head remains relatively constant over an initial range of flow rates.
At higher flow rates, the head decreases.
At sufficiently large flow rates, the head may decrease rapidly because of increasing internal losses.
This curve is called the pump head curve or pump characteristic curve.
The decrease at high flow rates occurs because friction, turbulence, recirculation, and other hydraulic losses inside the pump become more significant.
Shutoff head
The head produced when the flow rate is zero is called the shutoff head.
At shutoff:
The pump is running, but a closed valve prevents fluid from flowing through the system. The pump still develops pressure and head, although this condition is generally not desirable for extended operation because the fluid may overheat or the pump may be damaged.
5. Pump Shaft Power
The motor supplies power to the pump through the rotating shaft. This input power is called the shaft power or power into the pump.
The shaft power is
where:
W˙M is the mechanical shaft power
T is shaft torque
ω is angular velocity in radians per second
The shaft power may be reported in:
Watts or kilowatts
Horsepower
Torque and rotational speed are measured experimentally using the torque meter and tachometer in the shaft coupling.
At a fixed pump speed, shaft power commonly increases as flow rate increases. The exact shape depends on the pump design and the operating range.
6. Pump Hydraulic Power and Efficiency
The power delivered to the water is called the hydraulic power, or historically the water horsepower.
The hydraulic power is
where:
γ is the specific weight of the fluid
Q is volumetric flow rate
HP is pump head
The pump efficiency is the useful hydraulic power delivered to the water divided by the shaft power supplied to the pump:
Pump efficiency is dimensionless and is commonly reported as a percentage.
Equivalently,
Typical efficiency curve
At a constant speed, the efficiency curve generally has a maximum:
Efficiency is low at very small flow rates.
Efficiency increases as flow rate approaches an optimum value.
Efficiency reaches a maximum.
Efficiency decreases again at larger flow rates.
The flow rate corresponding to the maximum efficiency is the best-efficiency point, commonly abbreviated BEP.
The best-efficiency point is the operating condition at which the pump converts shaft power into hydraulic power most effectively.
Operating near the BEP is generally preferred because it reduces energy consumption, vibration, recirculation, and mechanical stress.
7. Effect of Pump Speed and Pump Condition
The pump-performance curves described above apply to a particular pump operating at a particular rotational speed.
If the pump speed changes:
The pump-head curve changes.
The power curve changes.
The efficiency curve may shift.
The flow rate and operating point in a system may change.
Manufacturers therefore provide separate performance information for different rotational speeds or impeller sizes.
Pump aging and performance degradation
A new pump generally has smooth impeller surfaces. Over time:
The impeller may become rough.
Surfaces may be eroded or pitted.
Internal clearances may increase.
Hydraulic losses may become larger.
Pump head may decrease.
Efficiency may decrease.
Therefore, the performance of an older pump may differ from the manufacturer’s original performance data.
8. Manufacturer Pump Performance Maps
Manufacturers often present pump data in the form of a pump performance map rather than as separate individual graphs.
A performance map may include:
Pump head versus flow rate
Efficiency contours or efficiency curves
Shaft power versus flow rate
Net positive suction head required versus flow rate
Impeller diameter curves
A single pump casing may accept impellers of several different diameters.
A manufacturer’s map may show curves for impeller diameters such as:
260 mm
240 mm
230 mm
205 mm
In general:
A larger impeller diameter produces a greater pump head.
A smaller impeller diameter produces a lower pump head.
The available flow range and power requirement also change with impeller diameter.
The performance map may show several head curves, each corresponding to a different impeller diameter, along with efficiency curves or efficiency regions.
Interpreting a manufacturer’s map
To determine pump performance for a selected impeller:
Select the curve corresponding to the impeller diameter.
Locate the desired flow rate on the horizontal axis.
Read the corresponding pump head from the head curve.
Read the efficiency from the efficiency curves or efficiency contours.
Read the shaft power from the power graph.
Read the required NPSH from the NPSH graph.
9. Net Positive Suction Head and Cavitation
Definition of NPSH
Net positive suction head, abbreviated NPSH, describes the pressure-head margin available at the pump suction above the fluid’s vapor pressure.
The manufacturer usually provides an NPSH curve, generally called the NPSH required curve. It indicates how much suction pressure head the pump needs at a particular flow rate to avoid cavitation.
NPSH depends on factors such as:
Flow rate
Pump design
Pump speed
Impeller diameter
Suction-pipe arrangement
Fluid temperature
Atmospheric pressure
Elevation of the pump relative to the reservoir
Vapor pressure
The vapor pressure of water, PV, is the pressure at which water begins to vaporize at a specified temperature.
For example, at 15∘C, the vapor pressure of water is approximately
Vapor pressure must be used as an absolute pressure, not as a gauge pressure.
Atmospheric pressure must also be expressed as absolute pressure when it is used in the same equation. Near standard atmospheric conditions,
Cavitation process
Cavitation occurs when the local absolute pressure in the pump falls to or below the fluid vapor pressure.
The process is:
The pump is placed above the suction reservoir.
As the elevation difference increases, pressure at the pump suction decreases.
If the local absolute pressure falls to the vapor pressure, vapor bubbles form.
These bubbles enter the impeller region.
As the fluid moves through the pump, pressure rises.
The vapor bubbles collapse suddenly.
The collapsing bubbles create localized high-impact pressure pulses.
Repeated impacts pit and erode the impeller surface.
Cavitation may produce:
A rattling, knocking, or crackling sound
Vibration
Impeller pitting
Roughened impeller surfaces
Reduced efficiency
Reduced pump head
Eventual pump failure
Cavitation is not merely the presence of bubbles; it is the formation and violent collapse of vapor bubbles caused by insufficient suction pressure.
10. Maximum Pump Elevation Above a Suction Reservoir
A pump can be positioned above a reservoir only if the pressure at the pump suction remains sufficiently above the water vapor pressure.
For a reservoir open to the atmosphere, a typical suction-side energy equation leads to
where Δz is the elevation of the pump suction above the reservoir free surface.
At the limiting condition for cavitation, the suction pressure is equal to the vapor pressure:
Solving for the maximum allowable elevation gives a relationship of the form
The manufacturer’s NPSH requirement is used to represent the necessary suction-pressure margin. In simplified form, the available elevation is calculated using
If suction-pipe losses are neglected,
Example calculation
Suppose:
Water temperature: 15∘C
Atmospheric pressure: Patm=101 kPa absolute
Water vapor pressure: PV=1.666 kPa absolute
Required NPSH: 7.4 m
Suction-pipe losses: negligible
Water specific weight: approximately γ=9800 N/m3
Then
which gives approximately
Thus, the pump should not be placed more than approximately 2.74 m above the suction-reservoir water surface under the stated operating conditions.
A higher pump elevation would reduce suction pressure and increase the likelihood of cavitation.
11. Pump Specific Speed and Pump Selection
Pump specific speed is a parameter used to select the most suitable pump type for a required flow rate, head, and rotational speed.
It is represented by Ns and is evaluated at the best-efficiency point.
Therefore, the required values of Q and H in the specific-speed calculation must be taken from the pump’s BEP:
Q is the flow rate at maximum efficiency.
H is the pump head at maximum efficiency.
The rotational speed is the pump speed.
Specific-speed equations depend on the unit system and the convention used. One form uses angular speed, flow rate, gravitational acceleration, and head; another engineering form is designed for rotational speed in RPM, flow rate in gallons per minute, and head in feet. The correct equation must be used with its corresponding units.
A commonly used SI-style form is
where ω is angular speed, Q is flow rate, g is gravitational acceleration, and H is head.
Pump type classification
Using the English-engineering form of specific speed, the general classifications are:
Centrifugal or radial-flow pump: approximately Ns=500 to 4000
Mixed-flow pump: approximately Ns=4000 to 10000
Axial-flow pump: approximately Ns>10000
A normalized form, often denoted Ns′, uses different numerical ranges:
Radial flow: Ns′<1
Mixed flow: approximately 1<Ns′<4
Axial flow: Ns′>4
The numerical value depends on the definition and unit convention, but the physical interpretation remains the same: increasing specific speed corresponds generally to a transition from radial flow to mixed flow and then to axial flow.
Pump flow directions
Radial-flow pump
A centrifugal pump is a radial-flow pump:
Fluid enters near the impeller axis.
The impeller throws the fluid outward.
The dominant flow direction is radial.
Axial-flow pump
An axial-flow pump operates similarly to a propeller:
The impeller pushes fluid along the pipe axis.
The dominant flow direction is parallel to the shaft.
Axial-flow pumps are generally suited to high flow rates and relatively low heads.
Mixed-flow pump
A mixed-flow pump combines the two behaviors:
Fluid receives both radial and axial velocity components.
It provides characteristics between those of radial-flow and axial-flow pumps.
12. Pump and System Head Curves
A pump does not operate at an arbitrary point on its performance curve. Its actual operating condition is determined by the interaction between:
The pump’s capability
The resistance of the connected piping system
The system is analyzed by writing an energy equation between the lower and upper reservoirs.
Consider two large reservoirs connected by a pipe and a pump. The reservoirs are open to the atmosphere, and the pump raises water through an elevation difference Δz.
The general energy equation is
where:
HP is the head supplied by the pump.
Δz is the elevation difference between reservoir free surfaces.
hL is the total pipe-system head loss.
For a pipe system containing major and minor losses,
where:
f is the Darcy friction factor
L is pipe length
D is pipe diameter
∑K is the sum of minor-loss coefficients
V is average pipe velocity
The total loss includes:
Major loss: Pipe-wall friction, represented by fL/D
Minor losses: Entrance, valves, bends, exits, fittings, and other components
Converting velocity to flow rate
Because pump curves are commonly plotted against flow rate, velocity is replaced using
so that
For a circular pipe,
Therefore,
Substituting this relationship into the system-energy equation produces a system-head equation in terms of Q.
13. Example: Finding the Operating Point
Suppose a system has:
Elevation difference: Δz=150 ft
Pipe length: L=1000 ft
Pipe diameter: D=1 ft
Friction factor: f=0.015
Combined minor-loss coefficient: ∑K=1.85
A centrifugal pump with a 205 mm impeller
The energy equation becomes
After replacing velocity with flow rate, the equation is represented in the form
when the appropriate flow-rate units are used.
Constructing the system-head curve
The system curve can be generated by selecting flow rates and calculating the corresponding system head.
For example:
At Q=0,
At Q=500 GPM, the corresponding flow rate is approximately 1.114 ft3/s, giving approximately
At Q=1000 GPM, the corresponding flow rate is approximately 2.228 ft3/s, giving approximately
The system curve begins at the static elevation head and rises as flow rate increases because friction and minor losses increase with velocity.
Operating point
The operating point is the intersection of:
The pump head curve, HP(Q)
The system head curve, Hsystem(Q)
At the operating point,
For the example, the intersection occurs at approximately:
Flow rate:
Pump head:
The operating point is the actual flow rate and pump head produced when that pump is connected to that particular piping system.
The pump curve describes what the pump can provide; the system curve describes what the piping system requires. Their intersection determines the actual operating condition.
14. Determining Power and Efficiency at the Operating Point
Once the operating flow rate is known, the manufacturer’s performance map can be used to determine the remaining pump characteristics.
For the example at approximately 880 GPM:
The required shaft power is approximately
Converting to horsepower gives approximately
The pump efficiency, interpolated from the manufacturer’s efficiency curves, is approximately
The hydraulic power delivered to the water is
For the example,
Thus, the pump-system operating condition is approximately:
Flow rate: 880 GPM
Pump head: 152 ft
Shaft input power: 40.2 hp
Hydraulic output power: approximately 28.9 hp
Pump efficiency: 72%
The NPSH requirement can also be read from the manufacturer’s performance map at the same operating flow rate.
15. Effect of Changing the Piping System
The pump curve is determined by the pump, its impeller, and its speed. The system curve is determined by the connected piping system.
Changing the following system characteristics changes the system curve:
Pipe diameter
Pipe length
Pipe roughness or material
Valve settings
Number and type of fittings
Entrance and exit conditions
Minor-loss coefficients
Decreasing pipe diameter
If the pipe diameter is reduced:
The flow velocity increases for the same flow rate.
Friction losses increase.
The system curve becomes steeper.
The operating-point flow rate decreases.
For example, reducing the pipe diameter from 1 ft to 0.5 ft greatly increases the velocity and therefore the loss term.
Increasing pipe diameter
If the pipe diameter is increased:
The velocity decreases for the same flow rate.
Friction losses decrease.
The system curve becomes flatter.
The operating-point flow rate increases.
For example, increasing the diameter from 1 ft to 2 ft reduces the resistance of the system and allows the same pump to produce a higher flow rate.
The pump curve remains unchanged when only the piping system is changed. The system curve shifts, and the new intersection with the unchanged pump curve gives the new operating point.

Ask anything
We've read this whole study set, so questions about it get the best answers.