Centrifugal Pump Performance


Centrifugal Pump Performance

Hope
Let’s begin with centrifugal pumps, a very common type of pump used in swimming pools, spas, and many other systems. In a fluids laboratory, you can test one by placing it in a closed water circuit connected to a large reservoir. Water flows from the reservoir through the pump and back again, while flow meters measure the flow rate, Q.

Corey
And the test setup measures more than just flow rate. Pressure gauges or differential pressure gauges are connected at points one and two on either side of the pump. A tachometer measures the pump shaft speed, and a torque meter measures the torque transmitted from the motor to the pump.

Hope
Exactly. Point one is on the suction side, where water enters the pump, and point two is on the discharge side, where water leaves. A centrifugal pump is a radial-flow pump because a rotating impeller throws the water outward in a radial direction. Its main purpose is to increase the fluid pressure, so the discharge pressure is greater than the suction pressure.

Corey
To analyze the pump, we write the energy equation from point one to point two. In head form, the pressure head, velocity head, and elevation head at point one, plus the pump head, equal the corresponding terms at point two.

Hope
In the laboratory setup, the pressure taps are very close to the pump, so there is little straight-pipe length to consider. The elevation difference between the taps is usually only a few inches, and the difference between the velocity heads is generally negligible. That leaves the pressure rise across the pump divided by the specific weight, approximately equal to the pump head, H sub P.

Corey
Continuity also gives us Q1 equals Q2, because the same flow passes through the suction and discharge sides. So, under those usual approximations, the pressure increase across the pump directly represents the head developed by the pump.

Hope
To create a performance curve, engineers operate the pump at a constant speed and vary the flow rate. They plot pump head on the vertical axis and flow rate, Q, on the horizontal axis. The typical head curve is fairly flat at lower flow rates, then drops more rapidly as flow increases because losses inside the pump become more significant.

Corey
The motor also provides the input shaft power. That power is the torque multiplied by angular speed: W dot M equals torque times omega. With torque and speed measured by the coupling, the power can be reported in kilowatts or converted to horsepower.

Hope
Then pump efficiency is the useful power delivered to the water divided by the shaft power entering the pump. The water power is gamma Q H sub P, so the efficiency is gamma Q H sub P divided by the input power. It is dimensionless.

Corey
Efficiency usually has a clear maximum. It is lower at both very small and very large flow rates, and it reaches a peak at one particular operating range. That peak is called the best efficiency point, or BEP. A pump generally operates most desirably near that point.

Hope
All of those curves depend on pump speed. If the speed changes, the head, power, and efficiency characteristics change as well. Pump manufacturers test their pumps and provide performance data, although an older pump may perform worse than a new one because its impeller surfaces become rough and worn.

Corey
Manufacturers often present the information as a pump performance map. One map can show several impeller diameters, such as 260, 240, 230, and 205 millimeters. For the same pump casing, a larger impeller generally produces a greater pump head.

Hope
On that same type of map, efficiency may be shown as contours such as 65, 70, or 75 percent rather than as one separate curve. Other sections show input power and NPSH, or net positive suction head, for the different impeller diameters.

Corey
There is also a special value called shutoff head. If a valve in the discharge line is closed while the pump is running, the flow rate is zero, but the pump still develops a head. That zero-flow head is the shutoff head.

Hope
NPSH is important because it helps determine how high a pump can be placed above the surface of its suction reservoir without cavitation. Imagine a reservoir feeding a pump located above it. As the pump is raised, the pressure at the suction side tends to fall.

Corey
If that pressure falls to the vapor pressure of the water, vapor bubbles form. Those bubbles enter the impeller along with the liquid. As the fluid moves through the pump, pressure rises, and the bubbles collapse. That process is cavitation.

Hope
Cavitation can produce a distinctive clunking or rattling sound, but the more serious problem is damage. The collapsing bubbles repeatedly strike the impeller, pitting and roughening its surface. Over time, efficiency decreases and the pump can eventually fail.

Corey
For a typical NPSH calculation, the pressure quantities must be absolute pressures. For example, at 15 degrees Celsius, the water vapor pressure is about 1,666 pascals, or 1.666 kilopascals, while atmospheric pressure is about 101 kilopascals. The pump manufacturer supplies the required NPSH at the specified flow rate.

Hope
The available elevation above the suction reservoir is found by balancing atmospheric pressure, vapor pressure, the water specific weight, the manufacturer’s NPSH value, and any suction-line losses. If the example uses an NPSH of 7.4 meters and neglects pipe losses, the maximum elevation comes out to about 2.74 meters.

Corey
So NPSH tells the engineer how far above the reservoir surface the pump can be installed before cavitation is expected to begin. That is why even a swimming-pool pump placed only a few feet above the pool may need to be checked.

Hope
Another selection tool is pump specific speed, written as N sub S. It is evaluated using the pump speed, flow rate, and head at the best efficiency point, not at an arbitrary point on the performance curve.

Corey
There are different versions of the specific-speed equation depending on the unit system. One version uses consistent SI units, while an English-engineering version is convenient because it uses pump speed in revolutions per minute, flow in gallons per minute, and head in feet.

Hope
Using the English-unit classification from the course, a specific speed between about 500 and 4,000 indicates a centrifugal, or radial-flow, pump. Values from about 4,000 to 10,000 indicate a mixed-flow pump, and values above 10,000 indicate an axial-flow pump.

Corey
The physical distinction matches those categories. A centrifugal pump sends fluid radially outward, an axial-flow pump moves fluid along the axis like a propeller, and a mixed-flow pump combines radial and axial motion. The alternate nondimensional classification uses different numerical ranges, so the units and definition must be identified before interpreting the number.

Hope
Now let’s put a pump into a complete pipe system. Suppose a lower reservoir feeds an upper reservoir, with a 150-foot elevation difference. Between them is 1,000 feet of one-foot-diameter pipe, with a friction factor of 0.015, and the pipe system also has minor losses with a combined coefficient of 1.85.

Corey
Because both reservoirs are open to the atmosphere, their gauge pressures are zero. Because the reservoirs are large, the surface velocities are approximately zero. Applying the energy equation from the lower free surface to the upper free surface gives the pump head as the elevation rise plus the major and minor head losses.

Hope
In this example, that relationship can be written as H sub P equals 150 plus 0.43 Q squared, when Q is expressed in cubic feet per second. The left side comes from the manufacturer’s pump curve, while the right side is the system head curve. The system curve starts at 150 feet when the flow is zero and rises as flow increases because friction losses increase.

Corey
To find the actual operating condition, plot both curves against flow rate. Where the pump-head curve and system-head curve intersect, the pump head exactly matches the head required by the pipe network. That intersection is the operating point.

Hope
For the stated 205-millimeter impeller and system, the intersection occurs at approximately 880 gallons per minute and a pump head of about 152 feet. The manufacturer’s input-power curve gives roughly 30 kilowatts, or about 40.2 horsepower, at that operating point.

Corey
Reading the efficiency contours at the same operating condition gives an efficiency of approximately 72 percent. The water horsepower can then be found from the efficiency relation: water power equals efficiency multiplied by shaft input power.

Hope
That operating point is not determined by the pump alone. The pump curve comes from the manufacturer, but the system curve comes from the elevation difference, pipe diameter, pipe length, friction factor, valves, entrances, exits, and other losses.

Corey
That is why changing the pipe changes the flow even if the pump stays the same. A smaller pipe creates more resistance, so the system curve becomes steeper and the operating-point flow rate decreases. A larger pipe reduces resistance, shifts the system curve downward, and increases the flow rate.

Hope
The same idea applies if you change the pipe length, the pipe material, or the minor-loss elements. In every case, you redraw or recalculate the system curve and find its new intersection with the pump curve.

Corey
One final fluids example involved three pipes in series with a known flow rate of 12.5 cubic meters per hour. Because the flow rate is already known, the velocities, Reynolds numbers, relative roughness values, and friction factors can be determined directly without iteration.

Hope
The reported friction factors were approximately 0.028, 0.026, and 0.031 for the three pipes. Substituting the losses into the energy equation gives an elevation difference of roughly 29.8 meters, or about 30 meters. That example reinforces the same central method: identify the flow, determine the losses, and apply the energy equation across the system.

Ask anything