Concrete is a material that can  handle a very small amount of   tensile stress. If this stress is exceeded,  the concrete fractures, making it unsuitable   for applications where members are in  tension only. In compression, however,   concrete is very strong and can handle a large  amount of stress before it eventually fractures. Beams are mainly subject to bending moments.  Typically, due to gravity loads, the top of the

beam is compressed while the bottom is in tension.  Because concrete is weak in tension, the beam will   fracture at the bottom. That is why reinforcement  is required, mainly in the form of steel rebars. In the presence of steel rebars, when  the beam is subject to bending moments   with the rebars on the tension side, the top  portion of the concrete will be in compression,   and the tensile loads will be fully carried  out by the steel rebars. This allows for an

effective cross-section against bending that  is not only stronger but also more ductile. This video aims to explain the ACI provisions  for reinforced concrete beams, specifically   for reinforced non-prestressed normal weight  concrete beams subject primarily to bending   moment and shear. It is highly advisable  to watch this video to the end to know how   to reinforce and dimension a concrete beam  according to ACI under different conditions.

We will also soon post a video with a full  example, so please subscribe to not miss that   video. Please note, however, that one example  is never enough as each project is individual,   so both videos combined will  give the best possible insight. ACI specifies stability requirements for  beams. If the beam is not continuously braced,   say by a concrete slab, then  the spacing of lateral bracing   shall not exceed 50 times the width of the  beam. Required strength shall be calculated in accordance with the factored load  combinations in the following table.

The minimum depth of the reinforced  concrete beams can be determined   referring to Table 9.3.1.1 of ACI. This table  is applicable when using normal weight concrete   and steel rebars with a yield strength of  60,000 psi. For fy other than 60,000 psi,   the expressions in Table 9.3.1.1 shall  be multiplied by the following factor. Simply supported means that the beam is supported  at the very ends only. When a beam runs across

multiple supports, the first span is considered  one end continuous. Whenever the beam runs above   two supports, as shown in the middle span, it  has two continuous ends. Cantilever can either   be taken as the overhang portion of a continuous  beam or a beam that is fixed from one end only. Non-prestressed beams with axial forces less  than 0.1 times the concrete compressive strength   multiplied by the gross cross-sectional area  shall be tension controlled as per Table 21.2.2,

where the yield strain can be determined as  follows. Strain in concrete and non-prestressed   reinforcement shall be assumed to be proportional  to the distance from the neutral axis. Equilibrium   shall be satisfied at each section. The maximum  strain at the extreme concrete compression fiber   shall be assumed to be 0.003. Tensile strength  of concrete is assumed to be nonexistent. Concrete stress of 0.85fc shall be assumed  uniformly distributed over an equivalent

compression zone bounded by edges of the  cross-section and a line parallel to the   neutral axis located at a distance “a” from the  fiber of maximum compressive strain. A is equal   to Beta one times c. This sets up an upper  limit for the area of steel reinforcement. A minimum area of flexural reinforcement  As,min shall be provided at every section   where tension reinforcement is required  by analysis. As,min shall be the larger   of (a) and (b). The value of  fy is limited to 80,000 psi.

The width of a beam bw can be determined based on  the flexural strength requirements by satisfying   the following strength design equation  where Mu is the maximum factored moment. At this stage, the required flexural  reinforcement is not yet known,   however, a range can be determined based on the  required minimum and maximum As. For Grade 60   reinforcement and a specified concrete compressive  strength of 4000 psi, as previously discussed,

the minimum and maximum As can be determined  as follows. The equation for maximum As is   coming from the equilibrium of forces. Because  the distance “a” is equal to Beta one times c,   the expression can be written to solve for As  such that the section is tension controlled. Using an initial estimate of 0.01bw d for the area  of the reinforcement, which is about the average   of max and min As, bw can be obtained by setting  Mu equal to Phi Mn. Then bw can be determined

as follows. The following are guidelines for  beam economy when sizing beams: use whole inch   increments for beam dimensions, use beam widths  in multiples of 2 or 3 inches, use constant beam   size from span to span and vary the reinforcement  as required, use wide shallower beams rather than   narrow deeper beams, use beam width at least 4  inches wider than the supporting column whenever   possible. If not, then the same width. Avoid using  beams narrower than the column as this increases

the work required for the formwork because the  columns extend along the depth of the beam.   This also reduces the reinforcement congestion  at the intersection between beam and column. After sizing the beam and approximating the area  of steel required by taking the average of the   minimum required and maximum allowed steel area,  the number and size of bars can be determined to   be equal to or greater than this number. After  obtaining the exact steel reinforcement area,

the strength of the member in flexure should  be greater than the maximum magnified applied   moment. The nominal flexural strength is  based on moment equilibrium. The depth of   the equivalent compressive stress block  “a” can be found by setting the tension   force in the reinforcement equal to the  compressive force in the concrete block. A minimum area of shear reinforcement Av,min  shall be provided at all regions where the following condition is met. Av is the area of  two legs of a closed stirrup. Av,min divided   by the shear reinforcement spacing s shall be  the larger of (a) and (b) in Table 9.6.3.4.

An exception is made for the following cases in  Table 9.6.3.1 where Av minimum is required only if   Vu is greater than Phi Vc. For normal  weight concrete, lambda is equal to 1. The nominal one-way shear strength Vn is  determined according to ACI 22.5, where there is   a contribution from concrete and a contribution  from steel. For non-prestressed members,   Vc is determined according to the equations in  Table 22.5.5.1. The following table contains

these equations as well as the maximum permitted  Vc according to ACI 22.5.5.1.1. The factor lambda   “s” is required to account for the fact that  the concrete shear strength does not increase   proportionally to the depth. The term rho w is  equal to the area of the flexural reinforcement   As divided by bw times d. To minimize the  likelihood of diagonal compression failure,   the cross-sectional dimensions of the section  must be selected to satisfy ACI Equation 22.5.1.2.

Stirrups oriented perpendicular to the axis of the  member and anchored to the longitudinal flexural   reinforcement are the most commonly used type  of shear reinforcement for beams in buildings.   The nominal shear strength provided by stirrups is  determined by ACI Equation 22.5.8.5.3. In general,   Av is equal to Ab times the number of stirrup legs  provided. Ab is the cross-sectional area of one

stirrup leg. The maximum stirrup spacing across  the width of the member is given in ACI Table   9.7.6.2.2 which translates to a minimum number of  stirrup legs needed across the width of the beam.   When more than two stirrup legs are required,  the following configurations are to be used. The required area of transverse reinforcement can  be determined with the following expression. The   shear reinforcement requirements according to ACI  are summarized here as follows. A minimum area

of torsional reinforcement shall be provided  in all regions where the torsion is greater   than or equal to the threshold torsion. The  threshold torsion can be extracted from Table   22.7.4.1(a). The minimum transverse reinforcement  required will be the greater of (a) and (b),   where At is the area of one leg of a closed  stirrup. The minimum longitudinal reinforcement   required will be the lesser of (a) and (b), where  ph is the perimeter of the centerline of outermost

closed transverse torsional reinforcement, and  pcp is the outside perimeter of the concrete   cross-section. As in most cases torsion in  concrete members is ignored or not significant,   the evaluation of the torsional strength  will be explained in a separate video. The minimum concrete cover to be provided can  be determined according to Table 20.5.1.3.1, which depends on the exposure to weather  and humidity as well as the size of the   used reinforcement. The minimum spacing of  flexural reinforcing bars is shown as follows,   where dagg is the nominal aggregate size in  the concrete mixture, and Db is the overall   diameter of the longitudinal reinforcement. The  following equation can be used to determine the   maximum number of reinforcing bars n_max that can  fit in a single layer based on the minimum spacing

limits. The value must be rounded down to the next  whole number. Maximum center-to-center spacing   of reinforcing bars is given in ACI 9.7.2.2 to  control flexural cracking. The following equation   can be used to determine the minimum number of  reinforcing bars n_min that must be in a single   layer to control flexural cracking. The value  must be rounded up to the next whole number. For beams with an overall depth greater than  36 in., longitudinal skin reinforcement must

be uniformly distributed on both faces of the  beam for a distance equal to at least h/2 from   the tension face to help control the width of  the cracks that can form on these faces. The   development length of deformed bars and deformed  wires in tension is the embedment length required   for the reinforcement to achieve the required  tension without slipping from the concrete. The   required development length is the greater of  the lengths calculated in Table 25.4.2.3 and 12

inches. To determine the modification factors  in the equations, refer to Table 25.4.2.5. A reinforcement lap splice is a method  of joining two reinforcement bars   by overlapping them and wiring them together.  For non-contact splices in flexural members,   the transverse center-to-center spacing of  spliced bars shall not exceed the minimum of   one fifth of the required lap splice length and  6 inches. The lap splice length of deformed bars

in tension is determined according to Table  25.5.2.1 and it depends on the development   length shown earlier. Along development  and lap splice lengths of longitudinal   bars with yield strength greater than or equal  to 80,000 psi, transverse reinforcement shall   be provided such that Ktr is not smaller than  0.5 times the bar diameter. N is the number of   longitudinal bars being developed and s is the  spacing between transverse reinforcements. Atr

is the total cross-sectional area of all  transverse reinforcement within spacing s   that crosses the potential plane of splitting  through the reinforcement being developed. Shear reinforcement must be properly anchored and  developed to be fully effective. Requirements for   the development of stirrups are given in ACI  25.7.1 and are illustrated here. In general,   the stirrups must extend as close to the  compression and tension surfaces of the

member as cover and other constraints permit  and must extend at least a distance d from   the extreme compression fiber. Each bend  in the continuous portion of a single or   multiple leg U stirrup and each bend in a closed  stirrup must enclose a longitudinal bar. Minimum   inside bend diameters and standard hook geometry  for stirrups, ties, and hoops are given in ACI   Table 25.3.2. Beams must have sufficient width  to allow for bend radii at corners of stirrups.

The following summarizes the recommended  flexural reinforcement of continuous   perimeter and non-perimeter beams.  Perimeter beams are those located   at the perimeter of the level in question.  All remaining beams are non-perimeter beams. Last but not least, the deflection limits have to  be met for serviceability requirements. For beams   loaded such that the maximum bending moment  at service loads Ma is less than or equal to

two-thirds the cracking moment, the section  is assumed to be uncracked. In this case,   the gross moment of inertia Ig of the section  (neglecting the longitudinal reinforcement) can   be used in the deflection calculations.  The cracking moment is determined by ACI   Equation 24.2.3.5, where yt is the distance  from the centroid of the gross section,   neglecting the reinforcement. The modulus  of rupture fr is calculated as follows.

Once a section cracks, the cracked moment of  inertia should be used instead. In general,   it is determined by transforming the longitudinal  steel reinforcement area to an equivalent area of   concrete. The concrete below the neutral  axis, which is located a distance equal   to kd below the extreme compression fiber,  is cracked and is ignored in the analysis.   For a rectangular concrete beam with  one layer of longitudinal reinforcement,

it works out as follows, where n is the ratio of  the steel elastic modulus to that of the concrete. In one-way flexural beams, creep and  shrinkage due to sustained loads cause   time-dependent deflections that can be 2 to 3  times greater than the immediate deflections.   Ignoring them can be catastrophic. They can  be calculated by multiplying the calculated   immediate deflections due to sustained loads  like dead loads by the factor lambda delta, which is determined by taking into account the  area of the steel compression reinforcement   if it exists. The value Xi depends on  the duration of the load application.