Concrete Beam Behavior

5:50
0:00-5:50
  1. Hope

    Concrete is incredibly strong in compression, but it can barely handle any tension. If a beam is loaded, the top compresses and the bottom stretches, so the bottom cracks unless we add steel reinforcement.

  2. Corey

    Right, and that's exactly why reinforced concrete beams exist — the steel carries all the tension while the concrete takes the compression. ACI has specific rules to make sure those beams are safe and ductile.

  3. Hope

    Exactly. First up, stability. If the beam isn't continuously braced by a slab, you need lateral bracing every 50 times the beam width. That prevents sideways buckling.

  4. Corey

    And for depth, ACI Table 9.3.1.1 gives minimum depths for normal-weight concrete with 60 ksi steel. If your steel is different, you multiply by a factor. The table covers simple spans, continuous ends, and cantilevers.

  5. Hope

    We also assume the section is tension-controlled, meaning the steel yields before the concrete crushes. The maximum strain in concrete is 0.003, and tensile strength of concrete is ignored. The stress block is 0.85 fc' over a depth a = β₁ c.

  6. Corey

    That stress block assumption gives us an upper limit on steel area. There's also a minimum — the larger of (3√fc'/fy) b w d or (200/fy) b w d, but fy is capped at 80 ksi. That ensures the beam doesn't fail suddenly.

  7. Hope

    Now, to size the beam width, we start with the factored moment Mu. We estimate As as 0.01 b w d — which is roughly the average of min and max — then solve for b w using Mu = φ M n. It gives a starting point.

  8. Corey

    And some practical tips: use whole inches for dimensions, widths in multiples of 2 or 3, keep beam size constant across spans and vary reinforcement, prefer wide shallow beams, and make the beam at least as wide as the supporting column to simplify formwork.

  9. Hope

    Once you have b w and d, pick actual bars. The number and size should give an As at least the average of min and max. Then check that φ M n ≥ Mu using the exact a = As fy / (0.85 fc' b w).

  10. Corey

    Shear is next. If the factored shear Vu exceeds φ Vc, you need stirrups. Minimum shear reinforcement Av,min/s is the larger of 0.75√fc' b w / f yt or 50 b w / f yt, but there are exceptions when Vu ≤ φ Vc for some members.

  11. Hope

    Vc comes from Table 22.5.5.1 — for non-prestressed, usually 2 λ √fc' b w d, but you can use a more detailed expression with ρ w and M u / V u d. And remember λ s accounts for depth effect.

  12. Corey

    To avoid diagonal compression failure, the section must satisfy Vu ≤ φ (Vc + 8 √fc' b w d). Stirrups are usually perpendicular to the axis, and Vs = Av f yt d / s. You pick spacing s to meet the demand.

  13. Hope

    Spacing limits: first check if Vs ≤ 4 √fc' b w d, then max s is d/2 or 24 inches. If Vs > that, max s is d/4 or 12 inches. Also, at least two legs across the width, more if needed per Table 9.7.6.2.2.

  14. Corey

    Torsion reinforcement is required only if torsion exceeds the threshold from Table 22.7.4.1. Most beams ignore torsion, so they'll cover that in another video. For now, the minimum transverse and longitudinal torsion steel is the greater of certain formulas.

  15. Hope

    Concrete cover per Table 20.5.1.3.1 depends on exposure. For beams, typically 1.5 inches for #5 bars and smaller, 2 inches for larger, but check the table. Minimum clear spacing between bars is at least the bar diameter, 1 inch, or 4/3 times aggregate size.

  16. Corey

    You can fit at most n_max bars in one layer using that spacing. To control cracking, max spacing is the lesser of 12 inches or 2.5 times clear cover plus 12 ksi / f s? Actually, ACI 9.7.2.2 says max spacing = 15(40,000/f s) - 2.5 c c, but not more than 12(40,000/f s).

  17. Hope

    For beams deeper than 36 inches, add skin reinforcement on the sides, total area at least 0.012 (b w)(h - 2c) distributed in the tension zone. That controls wide cracks.

  18. Corey

    Development length ensures the bar doesn't slip. For tension, use the greater of the equation from Table 25.4.2.3 and 12 inches. Modify for epoxy coating, bar spacing, cover, etc. Lap splices for bars use Table 25.5.2.1 — typically Class A or B depending on area ratio.

  19. Hope

    Don't forget that along development and lap splice lengths, if fy ≥ 80 ksi, you need transverse reinforcement so that K tr ≥ 0.5 d b. Also, stirrups must be anchored properly — each bend must enclose a longitudinal bar, and the stirrups extend close to surfaces.

  20. Corey

    Finally, deflection. If the service moment M a is less than 2/3 M cr, the section is uncracked and you use Ig. Otherwise, use cracked Ie. For sustained loads, multiply immediate deflection by λ Δ = ξ / (1 + 50ρ'), where ξ is 2 for 5 years or more.

  21. Hope

    That's a lot, but it's a complete workflow. The video also promises a full example soon, so subscribing makes sense. Together, the theory and example should let you design a reinforced concrete beam per ACI.