1. Home
  2. Explore
  3. Engineering
  4. Engineering Thermodynamics

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

Engineering Thermodynamics

Engineering Thermodynamics: From Energy Balances to the Rankine Cycle

Engineering thermodynamics becomes much easier when the subject is viewed as one connected story:

  1. A system is selected.
  2. Energy and, when necessary, mass are tracked across its boundary.
  3. The system is described using properties such as pressure, temperature, volume, enthalpy, and entropy.
  4. Conservation laws determine what can happen.
  5. The second law determines what actually can happen and how efficiently it can happen.
  6. Property tables and equations supply the numerical values needed to analyze real devices.

The steam power plant provides a useful anchor because it combines nearly every major idea in thermodynamics.


The Rankine Cycle: The Big Picture

A Rankine cycle is the idealized cycle used to model steam power plants. In the real world, a plant contains thousands of pipes, valves, heat exchangers, cooling towers, and machines. Thermodynamically, however, the plant can be reduced to four main components:

  1. Pump
  2. Boiler
  3. Turbine
  4. Condenser

The working fluid, usually water, moves continuously through these components in a closed loop.

The four states are commonly labeled as follows:

  • State 111: liquid leaving the condenser
  • State 222: high-pressure liquid leaving the pump
  • State 333: high-pressure, high-temperature steam leaving the boiler
  • State 444: low-pressure steam or wet mixture leaving the turbine

The pump: state 111 to state 222

The pump receives relatively cold, low-pressure liquid water and raises its pressure. The fluid remains approximately liquid, so the pump requires relatively little work.

This pressure increase is important because it allows the boiler to add heat at a higher pressure and temperature. Higher operating temperatures improve the thermal efficiency of the plant. The pump consumes energy, but the amount is small compared with the energy transferred in the boiler and turbine.

The boiler: state 222 to state 333

The boiler adds heat to the high-pressure water. The heat source could be:

  • Coal
  • Natural gas
  • Nuclear fuel
  • Geothermal energy
  • Solar energy

The source changes the way heat is supplied, but not the basic thermodynamic analysis. The water is heated, boiled, and often superheated until it becomes high-energy steam.

The turbine: state 333 to state 444

The turbine is the main work-producing component. High-pressure steam expands through turbine blades, much like air moving through a windmill. The steam’s enthalpy decreases, and the turbine converts part of that energy into shaft work. The shaft drives an electrical generator.

The turbine is the “moneymaker” because it produces the useful output of the power plant.

The condenser: state 444 to state 111

The turbine exhausts low-energy steam into the condenser. Heat is rejected to the environment, and the steam becomes liquid water again.

It requires much less work to pressurize a liquid than to pressurize a vapor. Therefore, condensing the steam before sending it back to the pump makes the cycle much more efficient.

The visible white cloud from a cooling tower is generally water vapor carrying rejected heat. It is different from dark smoke produced by combustion products.

In an ideal closed-loop power plant, the working fluid circulates internally. Heat and work cross the overall system boundary, but the working fluid does not.

The central calculations are therefore:

  • Heat transfer
  • Work
  • Thermal efficiency

Think About It

Why is it advantageous to condense the turbine exhaust before sending it back to the boiler?


Systems, Boundaries, and Surroundings

Thermodynamic analysis begins by choosing a system.

A system is the mass or region selected for study. Everything outside the system is the surroundings, and the surface separating them is the boundary.

The choice of boundary determines which equations apply.

Closed systems

A closed system contains a fixed amount of mass. Mass cannot cross its boundary, although energy can cross as heat or work.

A gas trapped inside a piston-cylinder is a typical closed system. The gas remains inside the cylinder, but:

  • Heat may enter or leave.
  • The piston may move, allowing boundary work.
  • A shaft or electrical connection could transfer work.

A closed system is sometimes called a control mass because the same mass is followed throughout the analysis.

Open systems and control volumes

An open system allows both mass and energy to cross its boundary. Engineers commonly call the selected region a control volume.

Examples include:

  • Turbines
  • Pumps
  • Nozzles
  • Compressors
  • Pipes
  • Heat exchangers

For example, a control volume surrounding a turbine includes the turbine itself, while steam enters, steam exits, and work leaves through the shaft.

Isolated systems

An isolated system is a special type of closed system. Neither mass nor energy crosses the boundary.

Two common clues are:

  • Rigid: no boundary movement, so boundary work is zero.
  • Insulated: no heat transfer, so heat transfer is zero.

A rigid and insulated closed system is isolated if no other energy interactions are present.

Choosing the boundary

The same physical plant can be analyzed using different systems.

  • A boundary around only the turbine produces an open-system analysis.
  • A boundary around the entire working-fluid loop can produce a closed-system cycle analysis because the fluid returns to its original location.
  • A boundary around an entire plant may include energy transfers with the environment but no net mass transfer.

The system boundary is not a physical fact that must be chosen one way. It is an analytical decision.


Thermodynamic Properties and States

A property is a measurable characteristic of a system. Important properties include:

  • Pressure, PPP
  • Temperature, TTT
  • Volume, VVV
  • Specific volume, vvv
  • Density, ρ\rhoρ
  • Internal energy, UUU
  • Enthalpy, HHH
  • Entropy, SSS

Lowercase letters commonly represent properties per unit mass:

u=Um,h=Hm,s=Smu=\frac{U}{m}, \qquad h=\frac{H}{m}, \qquad s=\frac{S}{m}u=mU​,h=mH​,s=mS​

Pressure

Thermodynamics uses absolute pressure, not gauge pressure.

Gauge pressure measures pressure relative to atmospheric pressure. Absolute pressure is measured relative to a perfect vacuum. Thermodynamic equations and property tables generally require absolute pressure.

Temperature

Thermodynamic temperature calculations use an absolute scale:

  • Kelvin in SI units
  • Rankine in English units

Celsius or Fahrenheit may be used when calculating a temperature difference because the size of a degree interval is preserved within each scale:

ΔT=T2−T1\Delta T = T_2-T_1ΔT=T2​−T1​

However, absolute temperature must be used in equations such as the ideal-gas law and Carnot efficiency.

Specific volume and density

Specific volume is volume per unit mass:

v=Vmv=\frac{V}{m}v=mV​

Density is mass per unit volume:

ρ=mV\rho=\frac{m}{V}ρ=Vm​

Therefore, specific volume and density are reciprocals:

v=1ρv=\frac{1}{\rho}v=ρ1​

A dense substance has a small specific volume, while a low-density gas has a large specific volume.

Internal energy

Internal energy, represented by UUU or uuu, is the microscopic energy stored within a substance. It includes the microscopic kinetic and potential energies associated with:

  • Molecular translation
  • Molecular rotation
  • Molecular vibration
  • Molecular interactions
  • Chemical bonding

Heating a substance generally increases its internal energy, but internal energy is not exactly the same thing as temperature. Temperature describes the thermal condition of a substance, while internal energy includes all microscopic forms of stored energy.

For many introductory problems, changes in macroscopic kinetic and potential energy are negligible, so internal energy is the main energy-storage term.

Enthalpy

Enthalpy is defined as

H=U+PVH=U+PVH=U+PV

or, per unit mass,

h=u+Pvh=u+Pvh=u+Pv

The PvPvPv term represents flow work: the work required for fluid to push its way into or out of a control volume.

Thus:

  • Closed systems are commonly analyzed using internal energy, UUU.
  • Open systems are commonly analyzed using enthalpy, HHH.

Enthalpy does not represent a completely new physical form of energy. It combines internal energy with the pressure-volume energy associated with fluid flow.


Equilibrium, Steady State, and Transient Behavior

These terms describe different features of a system and must not be treated as interchangeable.

Equilibrium

A system is in equilibrium when its properties are uniform and there are no unbalanced driving forces causing change.

For example, a rod with the same temperature everywhere may be in thermal equilibrium.

Steady state

A system is in steady state when its properties at fixed locations do not change with time.

A rod can be at steady state with one end hot and the other end cold. The temperature distribution remains constant, but the temperature is not uniform. Therefore, the rod can be steady without being in equilibrium.

Transient behavior

A transient system changes with time. Its properties at one or more locations vary as time passes.

A slowly leaking tire is a transient system because its pressure eventually changes.

Quasi-equilibrium

A process is quasi-equilibrium when it occurs slowly enough that the system can be treated as being in equilibrium at each instant.

A tire losing air through a very slow leak can be approximated as passing through a sequence of nearly equilibrium states, even though the overall process is transient.

Think About It

Can a system be in steady state without being in equilibrium? A rod with a constant temperature gradient demonstrates why the answer is yes.


States, Processes, and Cycles

A state is a snapshot of a system. Pressure, temperature, volume, and other properties describe the system at that instant.

A system’s state is fixed when two independent intensive properties are known. For example, pressure and temperature usually determine the state of a single-phase substance.

The word independent matters. In a saturated two-phase mixture, pressure and temperature are not independent because saturation pressure and saturation temperature are linked.

A process is a change from one equilibrium state to another.

A cycle consists of several processes that return the system to its original state.

Because internal energy is a property, it depends only on the state, not on the path. Therefore, over a complete cycle,

ΔUcycle=0\Delta U_{\text{cycle}}=0ΔUcycle​=0

The system may receive heat and produce work during the cycle, but its net internal energy does not change because it ends where it started.


The Zeroth and First Laws

The zeroth law

The zeroth law of thermodynamics establishes the meaning of temperature.

If system AAA is in thermal equilibrium with system BBB, and system BBB is in thermal equilibrium with system CCC, then system AAA is in thermal equilibrium with system CCC.

A thermometer acts as system BBB. If it reaches the same equilibrium reading when placed in two different objects, those objects have the same temperature.

This law makes temperature measurement logically consistent.

The first law

The first law of thermodynamics is the conservation of energy principle:

Energy cannot be created or destroyed; it can only be transferred or transformed.

Energy may exist as:

  • Kinetic energy
  • Potential energy
  • Internal energy
  • Heat transfer
  • Work transfer

For a closed system, using the sign convention that heat entering is positive and work done by the system is positive,

ΔU=Q−W\Delta U=Q-WΔU=Q−W

If kinetic and potential energy changes are included, the complete closed-system balance is

ΔE=ΔU+ΔKE+ΔPE=Q−W\Delta E=\Delta U+\Delta KE+\Delta PE=Q-WΔE=ΔU+ΔKE+ΔPE=Q−W

For stationary systems, the usual simplification is

ΔU=Q−W\Delta U=Q-WΔU=Q−W

Kinetic and potential energy

Kinetic energy results from motion:

KE=mV22KE=\frac{mV^2}{2}KE=2mV2​

Potential energy due to elevation is

PE=mgzPE=mgzPE=mgz

In many thermodynamic devices, changes in these terms are small compared with changes in internal energy or enthalpy. Nozzles and diffusers are important exceptions because their purpose is to change fluid velocity.

Heat and work

Heat, QQQ, is energy transferred across a boundary solely because of a temperature difference. Heat naturally transfers from a higher-temperature region to a lower-temperature region.

If there is no temperature difference driving the transfer, then

Q=0Q=0Q=0

Work, WWW, is energy transferred across a boundary for a reason other than temperature difference. Examples include:

  • Piston movement
  • Shaft rotation
  • Electrical work
  • Compression
  • Expansion

Heat and work are not properties stored inside a system. They describe energy crossing the boundary during a process.

Rates of heat and work

The rates of heat and work transfer are written as Q˙\dot QQ˙​ and W˙\dot WW˙:

Q˙=dQdt,W˙=dWdt\dot Q=\frac{dQ}{dt}, \qquad \dot W=\frac{dW}{dt}Q˙​=dtdQ​,W˙=dtdW​

In SI units, both have units of kilowatts:

1 kW=1 kJ/s1\ \mathrm{kW}=1\ \mathrm{kJ/s}1 kW=1 kJ/s

Sign conventions

The convention used here is:

  • Heat entering the system: Q>0Q>0Q>0
  • Heat leaving the system: Q<0Q<0Q<0
  • Work done by the system: W>0W>0W>0
  • Work done on the system: W<0W<0W<0

For a power plant:

  • Boiler heat input is positive.
  • Turbine work output is positive.
  • Pump work input is negative.
  • Condenser heat rejection is negative.

This convention explains why net work for a power plant is turbine work minus pump work.

Adiabatic processes

An adiabatic process has no heat transfer:

Q=0Q=0Q=0

or, for a rate,

Q˙=0\dot Q=0Q˙​=0

A process may be adiabatic because:

  1. The boundary is insulated.
  2. The process occurs so quickly that heat has no time to cross the boundary.

Rapid compression can therefore be approximately adiabatic even when the walls are not perfectly insulated. The work input raises the gas’s internal energy and temperature before heat can escape.

Example: an insulated piston-cylinder

For an insulated closed system, Q=0Q=0Q=0. If the gas expands and performs positive work, then

ΔU=0−W=−W\Delta U=0-W=-WΔU=0−W=−W

Therefore, the gas loses internal energy. Its molecular energy is converted into the work needed to lift or move the piston.

If a paddle wheel does work on an insulated, rigid tank, the work is negative under the chosen convention. Since the tank is rigid, there is no boundary work, but the paddle-wheel work enters the system. The internal energy increases.


Thermal Efficiency

Thermal efficiency measures how effectively a device converts an energy input into a desired output:

η=desired outputrequired input\eta=\frac{\text{desired output}}{\text{required input}}η=required inputdesired output​

For a heat engine or power plant,

η=Wnet,outQin\eta=\frac{W_{\text{net,out}}}{Q_{\text{in}}}η=Qin​Wnet,out​​

Efficiency is dimensionless and normally lies between 000 and 111, or between 0%0\%0% and 100%100\%100%.

For a complete cycle, the first law gives

Wnet,out=Qin−QoutW_{\text{net,out}}=Q_{\text{in}}-Q_{\text{out}}Wnet,out​=Qin​−Qout​

where QoutQ_{\text{out}}Qout​ represents the positive magnitude of rejected heat. Therefore,

η=1−QoutQin\eta=1-\frac{Q_{\text{out}}}{Q_{\text{in}}}η=1−Qin​Qout​​

A plant with a 40%40\%40% efficiency rejects approximately 60%60\%60% of its heat input to the environment. A plant with a 33%33\%33% efficiency rejects approximately 67%67\%67%.

The condenser’s rejected heat is not a failure of energy conservation. It is energy that cannot be converted into useful work under the operating conditions.

For steady operation, the rate form is

W˙net,out=Q˙in−Q˙out\dot W_{\text{net,out}}=\dot Q_{\text{in}}-\dot Q_{\text{out}}W˙net,out​=Q˙​in​−Q˙​out​

Example

Suppose a plant receives

Q˙in=800 MW\dot Q_{\text{in}}=800\ \mathrm{MW}Q˙​in​=800 MW

and rejects

Q˙out=480 MW\dot Q_{\text{out}}=480\ \mathrm{MW}Q˙​out​=480 MW

Then

W˙net,out=800−480=320 MW\dot W_{\text{net,out}}=800-480=320\ \mathrm{MW}W˙net,out​=800−480=320 MW

and

η=320800=0.40=40%\eta=\frac{320}{800}=0.40=40\%η=800320​=0.40=40%

Equivalently,

η=1−480800=0.40\eta=1-\frac{480}{800}=0.40η=1−800480​=0.40

Think About It

Why can a power plant’s overall energy balance be solved without knowing the detailed geometry of its turbine blades?


Phase Change and the Saturation Dome

Thermodynamics frequently analyzes pure substances, substances with a fixed and uniform chemical composition. Examples include water, nitrogen, and refrigerant R134a.

Water is especially important because it changes phase during the Rankine cycle.

The five important water states

During liquid-to-vapor heating, the following terms are used:

  1. Compressed liquid, also called subcooled liquid
  2. Saturated liquid
  3. Saturated mixture, or wet mixture
  4. Saturated vapor
  5. Superheated vapor

Compressed liquid

A compressed liquid is liquid water below its saturation temperature at the given pressure. It is not about to boil.

Saturated liquid

A saturated liquid is liquid at the exact condition where boiling is about to begin.

Two-phase mixture

Once boiling begins, liquid and vapor coexist. The system lies inside the saturation dome.

Saturated vapor

A saturated vapor is vapor at the exact condition where the last liquid droplet has just disappeared.

Superheated vapor

Additional heating after complete vaporization produces superheated vapor. Its temperature is higher than the saturation temperature at the given pressure.

Quality

Quality, represented by xxx, is the mass fraction of vapor in a saturated liquid-vapor mixture:

x=mvapormtotalx=\frac{m_{\text{vapor}}}{m_{\text{total}}}x=mtotal​mvapor​​

Thus:

  • x=0x=0x=0: saturated liquid
  • x=1x=1x=1: saturated vapor
  • 0<x<10<x<10<x<1: wet mixture

For a two-phase mixture, a property such as enthalpy can be found from

h=hf+xhfgh=h_f+xh_{fg}h=hf​+xhfg​

where

hfg=hg−hfh_{fg}=h_g-h_fhfg​=hg​−hf​

Equivalently,

x=h−hfhg−hfx=\frac{h-h_f}{h_g-h_f}x=hg​−hf​h−hf​​

The same mixture relation applies to other properties, such as internal energy, specific volume, and entropy:

u=uf+xufgu=u_f+xu_{fg}u=uf​+xufg​ v=vf+xvfgv=v_f+xv_{fg}v=vf​+xvfg​ s=sf+xsfgs=s_f+xs_{fg}s=sf​+xsfg​

Quality has meaning only inside the two-phase region. A compressed liquid and a superheated vapor do not have quality values.

The pressure-volume diagram

A PPP-vvv diagram plots pressure vertically and specific volume horizontally.

The saturation dome divides the diagram into regions:

  • Left of the dome: compressed liquid
  • Inside the dome: liquid-vapor mixture
  • Right of the dome: superheated vapor

Inside the two-phase region, pressure and temperature are linked. Knowing one determines the other through saturation data.

The top of the dome is the critical point. Above the critical point, distinct liquid and vapor phases no longer exist. For water, the critical point is approximately:

Tc=374∘CT_c=374^\circ\mathrm{C}Tc​=374∘C Pc=22.1 MPaP_c=22.1\ \mathrm{MPa}Pc​=22.1 MPa

Modern power plants may operate above the critical point in the supercritical region, but introductory analyses generally remain below or beside the critical point.


Steam Tables and Property Evaluation

Property tables provide experimentally based values for water and steam. The most important tables are:

  1. Saturated water—temperature table
  2. Saturated water—pressure table
  3. Superheated water-vapor table

Saturated temperature table

Use this table when temperature is known and the state is saturated.

Each temperature row commonly contains:

  • Saturation pressure
  • vfv_fvf​ and vgv_gvg​
  • ufu_fuf​, ugu_gug​, and ufgu_{fg}ufg​
  • hfh_fhf​, hgh_ghg​, and hfgh_{fg}hfg​
  • sfs_fsf​, sgs_gsg​, and sfgs_{fg}sfg​

The subscript fff refers to saturated liquid. The subscript ggg refers to saturated vapor. The subscript fgfgfg refers to the difference between vapor and liquid values:

hfg=hg−hfh_{fg}=h_g-h_fhfg​=hg​−hf​

Saturated pressure table

This table contains the same types of information, but the rows are organized by pressure instead of temperature.

Superheated vapor table

The superheated table is divided into smaller tables, usually one for each pressure. Within each small table, temperature determines the row.

Compressed-liquid approximation

Compressed-liquid tables may be small or omitted. Because liquid water is nearly incompressible, compressed-liquid properties are often approximated using the saturated-liquid property at the same temperature:

vcompressed liquid≈vf(T)v_{\text{compressed liquid}} \approx v_f(T)vcompressed liquid​≈vf​(T)

The temperature must match. Using the saturated-liquid value at the given pressure is not the standard approximation because pressure has little influence on liquid properties compared with temperature.

The table-selection workflow

Every property-table problem follows the same logic:

  1. Identify the substance.
  2. Determine the phase.
  3. Choose the correct table.
  4. Read the value or interpolate between values.

When the phase is uncertain, check the saturation temperature or saturation pressure first.

  • If the actual temperature is greater than the saturation temperature at that pressure, the state is superheated vapor.
  • If the actual temperature is less than the saturation temperature at that pressure, the state is compressed liquid.
  • If the condition lies between the saturated-liquid and saturated-vapor values, it is a two-phase mixture.

Interpolation

If a value lies between two table entries, interpolation estimates the value between them.

For a property yyy at an intermediate variable xxx,

x−x1x2−x1=y−y1y2−y1\frac{x-x_1}{x_2-x_1} = \frac{y-y_1}{y_2-y_1}x2​−x1​x−x1​​=y2​−y1​y−y1​​

For example, if 101∘C101^\circ\mathrm{C}101∘C lies between 100∘C100^\circ\mathrm{C}100∘C and 105∘C105^\circ\mathrm{C}105∘C,

101−100105−100=0.2\frac{101-100}{105-100}=0.2105−100101−100​=0.2

The corresponding enthalpy is therefore 20%20\%20% of the way from the value at 100∘C100^\circ\mathrm{C}100∘C to the value at 105∘C105^\circ\mathrm{C}105∘C.

For a mixture with quality x=0.6x=0.6x=0.6, the property must be 60%60\%60% of the way from the saturated-liquid value to the saturated-vapor value:

h−hfhg−hf=0.6\frac{h-h_f}{h_g-h_f}=0.6hg​−hf​h−hf​​=0.6

The fraction approach reinforces the physical meaning of quality and reduces sign mistakes.

Different textbooks may use slightly different property values because their tables are based on different data correlations. The differences are usually small, but values from different table sets should not be mixed within one problem.


Ideal Gases and Compressibility

For gases such as air, nitrogen, oxygen, and carbon dioxide, the ideal-gas equation is often more convenient than property tables.

The general equation is

PV=mRTPV=mRTPV=mRT

Using specific volume,

Pv=RTPv=RTPv=RT

where:

  • PPP is absolute pressure.
  • VVV is total volume.
  • vvv is specific volume.
  • mmm is mass.
  • TTT is absolute temperature.
  • RRR is the specific gas constant for the particular gas.

The universal gas constant is written differently and is used with molar quantities:

Rˉ=8.314 kJ/(kmol⋅K)\bar R=8.314\ \mathrm{kJ/(kmol\cdot K)}Rˉ=8.314 kJ/(kmol⋅K)

The specific gas constant is related to molar mass by

R=RˉMR=\frac{\bar R}{M}R=MRˉ​

The units must be checked carefully so that all terms are compatible.

When the ideal-gas model is appropriate

The ideal-gas approximation works best when the gas is:

  • At low pressure
  • At high temperature
  • Far from the saturation dome

Air near atmospheric pressure is usually modeled well as an ideal gas. High-pressure steam near saturation should generally be evaluated with steam tables instead.

For constant mass and constant gas constant, the ideal-gas law can be used in ratio form:

P1V1T1=P2V2T2\frac{P_1V_1}{T_1}=\frac{P_2V_2}{T_2}T1​P1​V1​​=T2​P2​V2​​

or, using specific volume,

P1v1T1=P2v2T2\frac{P_1v_1}{T_1}=\frac{P_2v_2}{T_2}T1​P1​v1​​=T2​P2​v2​​

If a tank is rigid, then

V1=V2V_1=V_2V1​=V2​

and the volume cancels. At constant volume,

P1T1=P2T2\frac{P_1}{T_1}=\frac{P_2}{T_2}T1​P1​​=T2​P2​​

Therefore, doubling absolute pressure doubles absolute temperature.

Compressibility factor

Real gases deviate from ideal behavior. The compressibility factor, ZZZ, corrects the ideal-gas relation:

Pv=ZRTPv=ZRTPv=ZRT

For an ideal gas,

Z=1Z=1Z=1

A real gas may have ZZZ above or below 111, depending on pressure and temperature.

To use a generalized compressibility chart, calculate reduced properties:

Pr=PPcP_r=\frac{P}{P_c}Pr​=Pc​P​ Tr=TTcT_r=\frac{T}{T_c}Tr​=Tc​T​

where PcP_cPc​ and TcT_cTc​ are the critical pressure and temperature of the gas.

The chart uses PrP_rPr​ and TrT_rTr​ to determine ZZZ. If ZZZ is close to 111, the ideal-gas model is probably adequate. If it differs substantially from 111, the correction is important.

The three main approaches are:

  1. Property tables: most accurate
  2. Compressibility chart: approximate but often useful
  3. Ideal-gas law: easiest but least accurate when non-ideal effects matter

Think About It

Why might an ideal-gas calculation be unsafe for a high-pressure carbon-dioxide storage container?


Boundary Work in Closed Systems

For a piston-cylinder, the most common work mode is moving-boundary work.

When a gas pushes a piston, the force on the piston is related to pressure:

F=PAF=PAF=PA

The differential work is

δW=F dx=PA dx\delta W=F\,dx=PA\,dxδW=Fdx=PAdx

Since

dV=A dxdV=A\,dxdV=Adx

the boundary work becomes

δW=P dV\delta W=P\,dVδW=PdV

and the total work is

Wb=∫V1V2P dVW_{b}=\int_{V_1}^{V_2}P\,dVWb​=∫V1​V2​​PdV

The units confirm that pressure times volume is energy:

Pa⋅m3=Nm2⋅m3=N⋅m=J\mathrm{Pa}\cdot\mathrm{m^3} = \frac{\mathrm{N}}{\mathrm{m^2}}\cdot\mathrm{m^3} = \mathrm{N\cdot m} = \mathrm{J}Pa⋅m3=m2N​⋅m3=N⋅m=J

Work on a PPP-VVV diagram

Boundary work is the area under the process curve on a PPP-VVV diagram.

  • Expansion moves to the right and gives Wb>0W_b>0Wb​>0.
  • Compression moves to the left and gives Wb<0W_b<0Wb​<0.
  • A constant-volume process is vertical, so the area is zero and Wb=0W_b=0Wb​=0.

Work is path dependent. Two processes can connect the same initial and final states but have different areas under their curves. Therefore, work is not a property of the state.

Common process models

Isochoric process

An isochoric process has constant volume:

V=constantV=\text{constant}V=constant

Because dV=0dV=0dV=0,

Wb=0W_b=0Wb​=0

Isobaric process

An isobaric process has constant pressure:

P=constantP=\text{constant}P=constant

The work is the rectangular area:

Wb=P(V2−V1)W_b=P(V_2-V_1)Wb​=P(V2​−V1​)

Polytropic process

A polytropic process follows

PVn=CPV^n=CPVn=C

where nnn is the polytropic exponent and CCC is a constant.

The endpoint relationship is

P1V1n=P2V2nP_1V_1^n=P_2V_2^nP1​V1n​=P2​V2n​

For n≠1n\neq 1n=1,

Wb=P2V2−P1V11−nW_b=\frac{P_2V_2-P_1V_1}{1-n}Wb​=1−nP2​V2​−P1​V1​​

Isothermal ideal-gas process

For constant temperature,

PV=mRT=constantPV=mRT=\text{constant}PV=mRT=constant

This corresponds to a polytropic process with

n=1n=1n=1

For an ideal gas,

Wb=mRTln⁡(V2V1)W_b=mRT\ln\left(\frac{V_2}{V_1}\right)Wb​=mRTln(V1​V2​​)

The logarithm is the natural logarithm.

Adiabatic ideal-gas process

An ideal-gas adiabatic process is modeled as polytropic with

n=kn=kn=k

where

k=CpCvk=\frac{C_p}{C_v}k=Cv​Cp​​

For air, kkk is approximately 1.41.41.4.

The Otto cycle

A four-stroke gasoline engine follows the Otto cycle model:

  1. Intake
  2. Compression
  3. Ignition and power stroke
  4. Exhaust

Compression involves work done on the gas, so the work is negative. The hot gas expands during the power stroke and does positive work. On a PPP-VVV diagram, the area enclosed by the cycle represents net work output.


Specific Heats and Ideal-Gas Energy Changes

Specific heat measures the energy required per unit mass to change a substance’s temperature by one degree.

For gases, two values are used:

  • CvC_vCv​: specific heat at constant volume
  • CpC_pCp​: specific heat at constant pressure

For an ideal gas, internal energy depends only on temperature:

Δu=Cv(T2−T1)\Delta u=C_v(T_2-T_1)Δu=Cv​(T2​−T1​)

Thus,

ΔU=mCvΔT\Delta U=mC_v\Delta TΔU=mCv​ΔT

Enthalpy also depends only on temperature:

Δh=Cp(T2−T1)\Delta h=C_p(T_2-T_1)Δh=Cp​(T2​−T1​)

Thus,

ΔH=mCpΔT\Delta H=mC_p\Delta TΔH=mCp​ΔT

The key rule is:

  • To calculate internal-energy change, use CvC_vCv​.
  • To calculate enthalpy change, use CpC_pCp​.

This rule applies even if the physical process itself is not constant volume or constant pressure.

For ideal gases,

Cp=Cv+RC_p=C_v+RCp​=Cv​+R

Therefore, CpC_pCp​ is greater than CvC_vCv​. Heating a gas at constant pressure requires extra energy because the gas expands and performs boundary work.

For liquids and solids, compressibility is small, so a single specific heat is usually used.

Specific heats vary somewhat with temperature. Over a small temperature range, they may be treated as constant. Over a large range, an average value based on the initial and final temperatures provides a better approximation.

Calorimetry

Calorimetry measures specific heat using energy conservation.

In an insulated container with no work,

Qtotal=0Q_{\text{total}}=0Qtotal​=0

Heat lost by the hot object equals heat gained by the cooler object:

mhotchotΔThot+mcoldccoldΔTcold=0m_{\text{hot}}c_{\text{hot}}\Delta T_{\text{hot}} + m_{\text{cold}}c_{\text{cold}}\Delta T_{\text{cold}} =0mhot​chot​ΔThot​+mcold​ccold​ΔTcold​=0

The unknown specific heat can be determined if the other quantities are measured.

At constant pressure, the heat-transfer shortcut is

Q=mCpΔTQ=mC_p\Delta TQ=mCp​ΔT

because the boundary work is already incorporated into CpC_pCp​.

At constant volume, work is zero, so

Q=ΔU=mCvΔTQ=\Delta U=mC_v\Delta TQ=ΔU=mCv​ΔT

These shortcuts are especially useful on timed examinations.


Open Systems and the Steady-Flow Energy Equation

An open system, or control volume, allows mass to cross its boundary.

Conservation of mass

Mass cannot be created or destroyed. The general rate balance is

dmCVdt=∑m˙in−∑m˙out\frac{dm_{\text{CV}}}{dt} = \sum \dot m_{\text{in}} - \sum \dot m_{\text{out}}dtdmCV​​=∑m˙in​−∑m˙out​

At steady state,

dmCVdt=0\frac{dm_{\text{CV}}}{dt}=0dtdmCV​​=0

so

∑m˙in=∑m˙out\sum \dot m_{\text{in}} = \sum \dot m_{\text{out}}∑m˙in​=∑m˙out​

For one inlet and one outlet,

m˙in=m˙out\dot m_{\text{in}}=\dot m_{\text{out}}m˙in​=m˙out​

The mass flow rate can be written in several equivalent ways:

m˙=ρAV\dot m=\rho A Vm˙=ρAV

Since v=1/ρv=1/\rhov=1/ρ,

m˙=AVv\dot m=\frac{AV}{v}m˙=vAV​

Here, VVV may represent flow velocity, while vvv represents specific volume. Units are the safest way to distinguish these quantities.

Energy carried by flowing mass

Flowing mass carries:

  • Internal energy
  • Kinetic energy
  • Potential energy
  • Flow work

Enthalpy combines internal energy and flow work:

h=u+Pvh=u+Pvh=u+Pv

This is why enthalpy is the natural property for open-system analysis.

Steady-flow energy equation

For a single-inlet, single-outlet steady-flow device,

Q˙−W˙=m˙[(h2−h1)+V22−V122+g(z2−z1)]\dot Q-\dot W = \dot m \left[ (h_2-h_1) + \frac{V_2^2-V_1^2}{2} + g(z_2-z_1) \right]Q˙​−W˙=m˙[(h2​−h1​)+2V22​−V12​​+g(z2​−z1​)]

The kinetic-energy term must be converted to compatible units. If velocity is in meters per second, then V2/2V^2/2V2/2 is in joules per kilogram. If enthalpy is in kilojoules per kilogram, divide the kinetic-energy term by 100010001000.

When kinetic and potential energy changes are negligible,

Q˙−W˙=m˙(h2−h1)\dot Q-\dot W = \dot m(h_2-h_1)Q˙​−W˙=m˙(h2​−h1​)

This simplified equation is used for most turbines, pumps, and heat exchangers.

Turbines

A turbine is usually:

  • Steady state
  • Adiabatic
  • Negligible in kinetic and potential energy changes

Therefore,

W˙turbine,out=m˙(h1−h2)\dot W_{\text{turbine,out}} = \dot m(h_1-h_2)W˙turbine,out​=m˙(h1​−h2​)

The enthalpy decreases because the fluid gives up energy to the shaft.

Pumps and compressors

A pump or compressor requires work input. Its outlet enthalpy is greater than its inlet enthalpy:

h2>h1h_2>h_1h2​>h1​

Under the sign convention that work out is positive,

W˙pump=m˙(h1−h2)<0\dot W_{\text{pump}}=\dot m(h_1-h_2)<0W˙pump​=m˙(h1​−h2​)<0

For incompressible liquid water, pump work is often approximated by

wpump≈v(P2−P1)w_{\text{pump}}\approx v(P_2-P_1)wpump​≈v(P2​−P1​)

Nozzles and diffusers

A nozzle accelerates a fluid. A diffuser decelerates it. Neither has a shaft, so

W˙=0\dot W=0W˙=0

They are commonly treated as adiabatic with negligible potential-energy change:

h1+V122=h2+V222h_1+\frac{V_1^2}{2} = h_2+\frac{V_2^2}{2}h1​+2V12​​=h2​+2V22​​

A nozzle converts enthalpy into kinetic energy. A diffuser converts kinetic energy back into enthalpy.

Heat exchangers

A heat exchanger transfers heat between fluid streams through a wall. It has no shaft work:

W˙=0\dot W=0W˙=0

If the control volume surrounds only one stream,

Q˙=m˙(h2−h1)\dot Q=\dot m(h_2-h_1)Q˙​=m˙(h2​−h1​)

If the control volume surrounds both streams, heat transfer across the outer boundary is approximately zero:

Q˙external=0\dot Q_{\text{external}}=0Q˙​external​=0

The heat lost by one stream equals the heat gained by the other.

Unsteady tank filling

A filling tank is not at steady state because mass and energy accumulate inside it.

For a rigid, insulated tank initially empty, with one inlet and no outlet:

  • Q=0Q=0Q=0
  • W=0W=0W=0
  • m1=0m_1=0m1​=0
  • No exit energy leaves

The energy balance reduces to

m2u2=minhinm_2u_2=m_{\text{in}}h_{\text{in}}m2​u2​=min​hin​

The mass balance gives

m2=minm_2=m_{\text{in}}m2​=min​

Therefore,

u2=hinu_2=h_{\text{in}}u2​=hin​

This result can seem surprising: the final internal energy in the tank equals the incoming enthalpy. The incoming fluid brings both internal energy and flow work, and the flow-work contribution becomes internal energy in the tank.

Think About It

Why does enthalpy appear in the inlet term of a filling-tank problem, while internal energy describes the final contents of the tank?


The Second Law, Heat Engines, and Refrigerators

The first law addresses the quantity of energy. The second law addresses direction, quality, and limitations.

The first law alone would not prohibit heat from spontaneously moving from a cold room into a hot cup of coffee. The second law explains why natural processes have preferred directions.

Thermal reservoirs

A thermal reservoir is an idealized body capable of absorbing or rejecting very large amounts of heat without changing temperature.

  • A reservoir supplying heat is a source.
  • A reservoir absorbing heat is a sink.

The atmosphere and ocean can often be approximated as reservoirs.

Heat engines

A heat engine operates cyclically:

  1. It receives heat QHQ_HQH​ from a high-temperature source.
  2. It converts part of that heat into net work.
  3. It rejects the remaining heat QLQ_LQL​ to a low-temperature sink.
  4. It repeats.

The cycle energy balance is

QH=Wnet+QLQ_H=W_{\text{net}}+Q_LQH​=Wnet​+QL​

or

Wnet=QH−QLW_{\text{net}}=Q_H-Q_LWnet​=QH​−QL​

The thermal efficiency is

η=WnetQH\eta=\frac{W_{\text{net}}}{Q_H}η=QH​Wnet​​

Kelvin–Planck statement

No cyclic heat engine can receive heat from only one reservoir and convert all of it into work. Some heat must be rejected to a lower-temperature sink.

Therefore, no heat engine can have

η=1\eta=1η=1

This is why the condenser is not optional in a power plant.

Clausius statement

Heat does not naturally flow from cold to hot. Moving heat uphill from a cold reservoir to a hot reservoir requires external work.

This is the operating principle of refrigerators and heat pumps.

Refrigerators and heat pumps

A refrigerator removes heat from a cold space. Its useful output is QLQ_LQL​:

COPR=QLWin\mathrm{COP}_{R}=\frac{Q_L}{W_{\text{in}}}COPR​=Win​QL​​

A heat pump delivers heat to a warm space. Its useful output is QHQ_HQH​:

COPHP=QHWin\mathrm{COP}_{HP}=\frac{Q_H}{W_{\text{in}}}COPHP​=Win​QH​​

Because

QH=QL+WinQ_H=Q_L+W_{\text{in}}QH​=QL​+Win​

the coefficients of performance satisfy

COPHP=COPR+1\mathrm{COP}_{HP}=\mathrm{COP}_{R}+1COPHP​=COPR​+1

A coefficient of performance can exceed 111 because it measures heat moved, not heat created. A heat pump may deliver several units of heat for each unit of electrical work by extracting additional heat from the outdoor environment.

Perpetual-motion machines

A perpetual-motion machine of the first kind violates the first law by producing more energy than it receives.

A perpetual-motion machine of the second kind violates the second law by converting heat completely into work or moving heat from cold to hot without work input.

Both are impossible.

Reversible and irreversible processes

A reversible process is an ideal process that can be undone without leaving any trace in the system or surroundings. It is frictionless and represents the maximum possible performance.

An irreversible process includes real-world losses such as:

  • Friction
  • Unrestrained expansion
  • Heat transfer across a finite temperature difference
  • Mixing
  • Electrical resistance
  • Chemical reactions

An impossible process would exceed the reversible limit or violate the second law.


The Carnot Cycle

The Carnot cycle establishes the maximum possible performance of a heat engine operating between two temperature reservoirs.

It consists of four reversible processes:

  1. Isothermal expansion at the hot temperature
  2. Adiabatic expansion
  3. Isothermal compression at the cold temperature
  4. Adiabatic compression

The maximum thermal efficiency is

ηCarnot=1−TLTH\eta_{\text{Carnot}}=1-\frac{T_L}{T_H}ηCarnot​=1−TH​TL​​

where THT_HTH​ and TLT_LTL​ are absolute temperatures in Kelvin or Rankine.

Celsius and Fahrenheit cannot be used in this equation.

The Carnot efficiency increases when:

  • THT_HTH​ increases
  • TLT_LTL​ decreases

This explains why engineers seek higher boiler temperatures and colder condenser temperatures.

The Carnot limits for a refrigerator and heat pump are

COPR,Carnot=TLTH−TL\mathrm{COP}_{R,\text{Carnot}} = \frac{T_L}{T_H-T_L}COPR,Carnot​=TH​−TL​TL​​

and

COPHP,Carnot=THTH−TL\mathrm{COP}_{HP,\text{Carnot}} = \frac{T_H}{T_H-T_L}COPHP,Carnot​=TH​−TL​TH​​

Actual devices must perform below these limits.

A practical engine related to the Carnot concept is the Stirling cycle, which uses two isothermal processes and two constant-volume processes. It can operate from an external temperature difference without internal combustion, but it still cannot achieve the ideal Carnot limit.

Performance comparison

To classify a real heat engine:

  1. Calculate actual efficiency.
  2. Calculate Carnot efficiency.
  3. Compare the two.
  • Actual efficiency below Carnot: possible and irreversible.
  • Actual efficiency equal to Carnot: reversible idealization.
  • Actual efficiency above Carnot: impossible or indicative of an error.

Entropy

Entropy is a thermodynamic property used to quantify the direction of processes and the effect of irreversibility.

Third law

The third law states that the entropy of a perfect crystal at absolute zero is zero:

S=0at T=0 KS=0 \qquad \text{at } T=0\ \mathrm{K}S=0at T=0 K

This supplies a reference point for entropy values.

Classical definition

For a reversible process,

dS=δQrevTdS=\frac{\delta Q_{\text{rev}}}{T}dS=TδQrev​​

or, for a finite reversible process,

ΔS=∫δQrevT\Delta S=\int\frac{\delta Q_{\text{rev}}}{T}ΔS=∫TδQrev​​

The classical engineering interpretation focuses on how heat transfer and temperature affect entropy.

Statistical interpretation

The statistical interpretation connects entropy with the number of microscopic arrangements corresponding to a macroscopic state. More possible microscopic arrangements correspond to greater entropy.

Regardless of interpretation, engineering problems treat entropy as a property, just like internal energy or enthalpy. For water and refrigerants, entropy is read from tables. For ideal gases, entropy changes are calculated with equations.

The TTT-sss diagram

A TTT-sss diagram plots temperature vertically and entropy horizontally.

It has the same general phase regions as the PPP-vvv diagram:

  • Compressed liquid on the left
  • Two-phase mixture under the dome
  • Superheated vapor on the right

For a reversible process, the area under a TTT-sss curve represents heat transfer:

Qrev=∫T dSQ_{\text{rev}}=\int T\,dSQrev​=∫TdS

The Carnot cycle becomes a rectangle on a TTT-sss diagram:

  • Horizontal lines: isothermal heat-transfer processes
  • Vertical lines: constant-entropy processes

Isentropic processes

An isentropic process has constant entropy:

ΔS=0\Delta S=0ΔS=0

A process is isentropic when it is both:

  1. Adiabatic
  2. Reversible

Thus,

adiabatic+reversible=isentropic\text{adiabatic}+\text{reversible} = \text{isentropic}adiabatic+reversible=isentropic

For an ideal turbine, pump, compressor, or nozzle, an isentropic assumption provides the ideal reference case.

For a turbine, knowing

s2=s1s_2=s_1s2​=s1​

allows the exit state to be found. If the exit condition lies inside the saturation dome, quality is determined using

x=s−sfsg−sfx=\frac{s-s_f}{s_g-s_f}x=sg​−sf​s−sf​​

This is a central Rankine-cycle calculation.

Isentropic efficiency

Real machines are not perfectly reversible, even when they are approximately adiabatic.

For a turbine, the desired output is work output:

ηt=wactualwisentropic\eta_{t} = \frac{w_{\text{actual}}}{w_{\text{isentropic}}}ηt​=wisentropic​wactual​​

The actual turbine produces less work than the ideal turbine.

For a pump or compressor, the desired result is minimum work input:

ηp=wisentropicwactual\eta_{p} = \frac{w_{\text{isentropic}}}{w_{\text{actual}}}ηp​=wactual​wisentropic​​

The actual pump requires more work than the isentropic pump.

On a TTT-sss diagram, real adiabatic components generally move to the right because entropy increases.

Entropy balance

The entropy balance includes entropy transfer and internal entropy generation. In rate form for a control volume,

dSCVdt=∑Q˙jTj+∑m˙insin−∑m˙outsout+S˙gen\frac{dS_{\text{CV}}}{dt} = \sum\frac{\dot Q_j}{T_j} + \sum\dot m_{\text{in}}s_{\text{in}} - \sum\dot m_{\text{out}}s_{\text{out}} + \dot S_{\text{gen}}dtdSCV​​=∑Tj​Q˙​j​​+∑m˙in​sin​−∑m˙out​sout​+S˙gen​

The entropy-generation rate satisfies

S˙gen≥0\dot S_{\text{gen}}\geq 0S˙gen​≥0
  • S˙gen=0\dot S_{\text{gen}}=0S˙gen​=0: reversible process
  • S˙gen>0\dot S_{\text{gen}}>0S˙gen​>0: irreversible process
  • S˙gen<0\dot S_{\text{gen}}<0S˙gen​<0: impossible result or calculation error

For a steady, insulated compressor with one inlet and one outlet, the entropy balance reduces to

S˙gen=m˙(s2−s1)\dot S_{\text{gen}} = \dot m(s_2-s_1)S˙gen​=m˙(s2​−s1​)

Therefore, a physically possible process must have

s2≥s1s_2\geq s_1s2​≥s1​

Think About It

What does a negative entropy-generation result indicate about a proposed engineering process?


Complete Rankine-Cycle Analysis

The Rankine cycle can now be analyzed as four steady-flow control volumes.

Pump: state 111 to state 222

Typical assumptions:

  • Steady state
  • Adiabatic
  • Negligible kinetic and potential energy changes
  • Liquid approximately incompressible

For an ideal pump,

s2=s1s_2=s_1s2​=s1​

The pump work is approximately

wp≈v1(P2−P1)w_p\approx v_1(P_2-P_1)wp​≈v1​(P2​−P1​)

The pump work is usually small because liquid water has a small specific volume.

Boiler: state 222 to state 333

Typical assumptions:

  • Steady state
  • No shaft work
  • Negligible kinetic and potential energy changes

The heat added is

qin=h3−h2q_{\text{in}}=h_3-h_2qin​=h3​−h2​

The boiler raises the fluid’s temperature, enthalpy, and generally entropy. During boiling under a fixed pressure, temperature remains at the saturation temperature while the phase changes.

Turbine: state 333 to state 444

Typical assumptions:

  • Steady state
  • Adiabatic
  • Negligible kinetic and potential energy changes

For an ideal turbine,

s4=s3s_4=s_3s4​=s3​

The ideal turbine work is

wt,isentropic=h3−h4sw_{t,\text{isentropic}}=h_3-h_{4s}wt,isentropic​=h3​−h4s​

For an actual turbine, the exit enthalpy is higher and the work output is lower. The turbine is the main work-producing component.

Condenser: state 444 to state 111

Typical assumptions:

  • Steady state
  • No shaft work
  • Negligible kinetic and potential energy changes

The rejected heat is

qout=h4−h1q_{\text{out}}=h_4-h_1qout​=h4​−h1​

The condenser returns the working fluid to liquid form. Heat rejection cannot be eliminated because the second law requires a low-temperature sink for a heat engine.

Overall thermal efficiency

The net work is

wnet=wt−wpw_{\text{net}}=w_t-w_pwnet​=wt​−wp​

The thermal efficiency is

ηRankine=wt−wpqin\eta_{\text{Rankine}} = \frac{w_t-w_p}{q_{\text{in}}}ηRankine​=qin​wt​−wp​​

The most important practical observations are:

  • Pump work is small.
  • Boiler heat input is large.
  • Turbine work output is the primary useful output.
  • Condenser heat rejection is unavoidable.
  • Small efficiency improvements in turbine performance can produce large economic benefits.

The most efficient problem-solving strategy is to identify the component being asked about and use only the two enthalpies that bound that component. Extra state data may be included as distractors.


Comprehensive Review

The complete logic of engineering thermodynamics can be summarized as follows:

  1. Choose a system. Decide whether the analysis uses a closed system or an open-system control volume.
  2. Identify the type of behavior. Determine whether the system is in equilibrium, steady state, transient operation, or quasi-equilibrium.
  3. Track mass and energy. Use mass conservation for open systems and the first law for energy.
  4. Use the correct energy property. Internal energy is central for closed systems; enthalpy is central for flowing open systems because it includes flow work.
  5. Apply the sign convention carefully. Heat entering and work leaving are positive under the chosen convention.
  6. Recognize keywords. Rigid implies no boundary work; insulated or adiabatic implies no heat transfer; steady state eliminates accumulation; isothermal means constant temperature; isentropic means constant entropy.
  7. Identify the phase. Compare the state with saturation conditions and locate it relative to the saturation dome.
  8. Choose the correct property tool. Use saturated tables, superheated tables, compressed-liquid approximations, ideal-gas equations, or compressibility corrections as appropriate.
  9. Calculate process work. For piston-cylinder systems, boundary work is the area under the PPP-VVV curve and depends on the path.
  10. Use the second law. Heat engines require heat rejection, refrigerators require work input, and entropy generation cannot be negative.
  11. Compare real and ideal devices. Reversible or isentropic performance is the upper limit; real machines are irreversible and perform below that limit.
  12. Return to the Rankine cycle. The pump raises pressure, the boiler adds heat, the turbine produces work, and the condenser rejects heat.

The Rankine cycle is not a collection of unrelated equations. It is one continuous application of conservation of mass, conservation of energy, phase-property evaluation, process analysis, and the second law of thermodynamics.

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent