Engineering Thermodynamics
Engineering Thermodynamics: From Energy Balances to the Rankine Cycle
Engineering thermodynamics becomes much easier when the subject is viewed as one connected story:
- A system is selected.
- Energy and, when necessary, mass are tracked across its boundary.
- The system is described using properties such as pressure, temperature, volume, enthalpy, and entropy.
- Conservation laws determine what can happen.
- The second law determines what actually can happen and how efficiently it can happen.
- Property tables and equations supply the numerical values needed to analyze real devices.
The steam power plant provides a useful anchor because it combines nearly every major idea in thermodynamics.
The Rankine Cycle: The Big Picture
A Rankine cycle is the idealized cycle used to model steam power plants. In the real world, a plant contains thousands of pipes, valves, heat exchangers, cooling towers, and machines. Thermodynamically, however, the plant can be reduced to four main components:
- Pump
- Boiler
- Turbine
- Condenser
The working fluid, usually water, moves continuously through these components in a closed loop.
The four states are commonly labeled as follows:
- State 1: liquid leaving the condenser
- State 2: high-pressure liquid leaving the pump
- State 3: high-pressure, high-temperature steam leaving the boiler
- State 4: low-pressure steam or wet mixture leaving the turbine
The pump: state 1 to state 2
The pump receives relatively cold, low-pressure liquid water and raises its pressure. The fluid remains approximately liquid, so the pump requires relatively little work.
This pressure increase is important because it allows the boiler to add heat at a higher pressure and temperature. Higher operating temperatures improve the thermal efficiency of the plant. The pump consumes energy, but the amount is small compared with the energy transferred in the boiler and turbine.
The boiler: state 2 to state 3
The boiler adds heat to the high-pressure water. The heat source could be:
- Coal
- Natural gas
- Nuclear fuel
- Geothermal energy
- Solar energy
The source changes the way heat is supplied, but not the basic thermodynamic analysis. The water is heated, boiled, and often superheated until it becomes high-energy steam.
The turbine: state 3 to state 4
The turbine is the main work-producing component. High-pressure steam expands through turbine blades, much like air moving through a windmill. The steam’s enthalpy decreases, and the turbine converts part of that energy into shaft work. The shaft drives an electrical generator.
The turbine is the “moneymaker” because it produces the useful output of the power plant.
The condenser: state 4 to state 1
The turbine exhausts low-energy steam into the condenser. Heat is rejected to the environment, and the steam becomes liquid water again.
It requires much less work to pressurize a liquid than to pressurize a vapor. Therefore, condensing the steam before sending it back to the pump makes the cycle much more efficient.
The visible white cloud from a cooling tower is generally water vapor carrying rejected heat. It is different from dark smoke produced by combustion products.
In an ideal closed-loop power plant, the working fluid circulates internally. Heat and work cross the overall system boundary, but the working fluid does not.
The central calculations are therefore:
- Heat transfer
- Work
- Thermal efficiency
Think About It
Why is it advantageous to condense the turbine exhaust before sending it back to the boiler?
Systems, Boundaries, and Surroundings
Thermodynamic analysis begins by choosing a system.
A system is the mass or region selected for study. Everything outside the system is the surroundings, and the surface separating them is the boundary.
The choice of boundary determines which equations apply.
Closed systems
A closed system contains a fixed amount of mass. Mass cannot cross its boundary, although energy can cross as heat or work.
A gas trapped inside a piston-cylinder is a typical closed system. The gas remains inside the cylinder, but:
- Heat may enter or leave.
- The piston may move, allowing boundary work.
- A shaft or electrical connection could transfer work.
A closed system is sometimes called a control mass because the same mass is followed throughout the analysis.
Open systems and control volumes
An open system allows both mass and energy to cross its boundary. Engineers commonly call the selected region a control volume.
Examples include:
- Turbines
- Pumps
- Nozzles
- Compressors
- Pipes
- Heat exchangers
For example, a control volume surrounding a turbine includes the turbine itself, while steam enters, steam exits, and work leaves through the shaft.
Isolated systems
An isolated system is a special type of closed system. Neither mass nor energy crosses the boundary.
Two common clues are:
- Rigid: no boundary movement, so boundary work is zero.
- Insulated: no heat transfer, so heat transfer is zero.
A rigid and insulated closed system is isolated if no other energy interactions are present.
Choosing the boundary
The same physical plant can be analyzed using different systems.
- A boundary around only the turbine produces an open-system analysis.
- A boundary around the entire working-fluid loop can produce a closed-system cycle analysis because the fluid returns to its original location.
- A boundary around an entire plant may include energy transfers with the environment but no net mass transfer.
The system boundary is not a physical fact that must be chosen one way. It is an analytical decision.
Thermodynamic Properties and States
A property is a measurable characteristic of a system. Important properties include:
- Pressure, P
- Temperature, T
- Volume, V
- Specific volume, v
- Density, ρ
- Internal energy, U
- Enthalpy, H
- Entropy, S
Lowercase letters commonly represent properties per unit mass:
u=mU,h=mH,s=mSPressure
Thermodynamics uses absolute pressure, not gauge pressure.
Gauge pressure measures pressure relative to atmospheric pressure. Absolute pressure is measured relative to a perfect vacuum. Thermodynamic equations and property tables generally require absolute pressure.
Temperature
Thermodynamic temperature calculations use an absolute scale:
- Kelvin in SI units
- Rankine in English units
Celsius or Fahrenheit may be used when calculating a temperature difference because the size of a degree interval is preserved within each scale:
ΔT=T2−T1However, absolute temperature must be used in equations such as the ideal-gas law and Carnot efficiency.
Specific volume and density
Specific volume is volume per unit mass:
v=mVDensity is mass per unit volume:
ρ=VmTherefore, specific volume and density are reciprocals:
v=ρ1A dense substance has a small specific volume, while a low-density gas has a large specific volume.
Internal energy
Internal energy, represented by U or u, is the microscopic energy stored within a substance. It includes the microscopic kinetic and potential energies associated with:
- Molecular translation
- Molecular rotation
- Molecular vibration
- Molecular interactions
- Chemical bonding
Heating a substance generally increases its internal energy, but internal energy is not exactly the same thing as temperature. Temperature describes the thermal condition of a substance, while internal energy includes all microscopic forms of stored energy.
For many introductory problems, changes in macroscopic kinetic and potential energy are negligible, so internal energy is the main energy-storage term.
Enthalpy
Enthalpy is defined as
H=U+PVor, per unit mass,
h=u+PvThe Pv term represents flow work: the work required for fluid to push its way into or out of a control volume.
Thus:
- Closed systems are commonly analyzed using internal energy, U.
- Open systems are commonly analyzed using enthalpy, H.
Enthalpy does not represent a completely new physical form of energy. It combines internal energy with the pressure-volume energy associated with fluid flow.
Equilibrium, Steady State, and Transient Behavior
These terms describe different features of a system and must not be treated as interchangeable.
Equilibrium
A system is in equilibrium when its properties are uniform and there are no unbalanced driving forces causing change.
For example, a rod with the same temperature everywhere may be in thermal equilibrium.
Steady state
A system is in steady state when its properties at fixed locations do not change with time.
A rod can be at steady state with one end hot and the other end cold. The temperature distribution remains constant, but the temperature is not uniform. Therefore, the rod can be steady without being in equilibrium.
Transient behavior
A transient system changes with time. Its properties at one or more locations vary as time passes.
A slowly leaking tire is a transient system because its pressure eventually changes.
Quasi-equilibrium
A process is quasi-equilibrium when it occurs slowly enough that the system can be treated as being in equilibrium at each instant.
A tire losing air through a very slow leak can be approximated as passing through a sequence of nearly equilibrium states, even though the overall process is transient.
Think About It
Can a system be in steady state without being in equilibrium? A rod with a constant temperature gradient demonstrates why the answer is yes.
States, Processes, and Cycles
A state is a snapshot of a system. Pressure, temperature, volume, and other properties describe the system at that instant.
A system’s state is fixed when two independent intensive properties are known. For example, pressure and temperature usually determine the state of a single-phase substance.
The word independent matters. In a saturated two-phase mixture, pressure and temperature are not independent because saturation pressure and saturation temperature are linked.
A process is a change from one equilibrium state to another.
A cycle consists of several processes that return the system to its original state.
Because internal energy is a property, it depends only on the state, not on the path. Therefore, over a complete cycle,
ΔUcycle=0The system may receive heat and produce work during the cycle, but its net internal energy does not change because it ends where it started.
The Zeroth and First Laws
The zeroth law
The zeroth law of thermodynamics establishes the meaning of temperature.
If system A is in thermal equilibrium with system B, and system B is in thermal equilibrium with system C, then system A is in thermal equilibrium with system C.
A thermometer acts as system B. If it reaches the same equilibrium reading when placed in two different objects, those objects have the same temperature.
This law makes temperature measurement logically consistent.
The first law
The first law of thermodynamics is the conservation of energy principle:
Energy cannot be created or destroyed; it can only be transferred or transformed.
Energy may exist as:
- Kinetic energy
- Potential energy
- Internal energy
- Heat transfer
- Work transfer
For a closed system, using the sign convention that heat entering is positive and work done by the system is positive,
ΔU=Q−WIf kinetic and potential energy changes are included, the complete closed-system balance is
ΔE=ΔU+ΔKE+ΔPE=Q−WFor stationary systems, the usual simplification is
ΔU=Q−WKinetic and potential energy
Kinetic energy results from motion:
KE=2mV2Potential energy due to elevation is
PE=mgzIn many thermodynamic devices, changes in these terms are small compared with changes in internal energy or enthalpy. Nozzles and diffusers are important exceptions because their purpose is to change fluid velocity.
Heat and work
Heat, Q, is energy transferred across a boundary solely because of a temperature difference. Heat naturally transfers from a higher-temperature region to a lower-temperature region.
If there is no temperature difference driving the transfer, then
Q=0Work, W, is energy transferred across a boundary for a reason other than temperature difference. Examples include:
- Piston movement
- Shaft rotation
- Electrical work
- Compression
- Expansion
Heat and work are not properties stored inside a system. They describe energy crossing the boundary during a process.
Rates of heat and work
The rates of heat and work transfer are written as Q˙ and W˙:
Q˙=dtdQ,W˙=dtdWIn SI units, both have units of kilowatts:
1 kW=1 kJ/sSign conventions
The convention used here is:
- Heat entering the system: Q>0
- Heat leaving the system: Q<0
- Work done by the system: W>0
- Work done on the system: W<0
For a power plant:
- Boiler heat input is positive.
- Turbine work output is positive.
- Pump work input is negative.
- Condenser heat rejection is negative.
This convention explains why net work for a power plant is turbine work minus pump work.
Adiabatic processes
An adiabatic process has no heat transfer:
Q=0or, for a rate,
Q˙=0A process may be adiabatic because:
- The boundary is insulated.
- The process occurs so quickly that heat has no time to cross the boundary.
Rapid compression can therefore be approximately adiabatic even when the walls are not perfectly insulated. The work input raises the gas’s internal energy and temperature before heat can escape.
Example: an insulated piston-cylinder
For an insulated closed system, Q=0. If the gas expands and performs positive work, then
ΔU=0−W=−WTherefore, the gas loses internal energy. Its molecular energy is converted into the work needed to lift or move the piston.
If a paddle wheel does work on an insulated, rigid tank, the work is negative under the chosen convention. Since the tank is rigid, there is no boundary work, but the paddle-wheel work enters the system. The internal energy increases.
Thermal Efficiency
Thermal efficiency measures how effectively a device converts an energy input into a desired output:
η=required inputdesired outputFor a heat engine or power plant,
η=QinWnet,outEfficiency is dimensionless and normally lies between 0 and 1, or between 0% and 100%.
For a complete cycle, the first law gives
Wnet,out=Qin−Qoutwhere Qout represents the positive magnitude of rejected heat. Therefore,
η=1−QinQoutA plant with a 40% efficiency rejects approximately 60% of its heat input to the environment. A plant with a 33% efficiency rejects approximately 67%.
The condenser’s rejected heat is not a failure of energy conservation. It is energy that cannot be converted into useful work under the operating conditions.
For steady operation, the rate form is
W˙net,out=Q˙in−Q˙outExample
Suppose a plant receives
Q˙in=800 MWand rejects
Q˙out=480 MWThen
W˙net,out=800−480=320 MWand
η=800320=0.40=40%Equivalently,
η=1−800480=0.40Think About It
Why can a power plant’s overall energy balance be solved without knowing the detailed geometry of its turbine blades?
Phase Change and the Saturation Dome
Thermodynamics frequently analyzes pure substances, substances with a fixed and uniform chemical composition. Examples include water, nitrogen, and refrigerant R134a.
Water is especially important because it changes phase during the Rankine cycle.
The five important water states
During liquid-to-vapor heating, the following terms are used:
- Compressed liquid, also called subcooled liquid
- Saturated liquid
- Saturated mixture, or wet mixture
- Saturated vapor
- Superheated vapor
Compressed liquid
A compressed liquid is liquid water below its saturation temperature at the given pressure. It is not about to boil.
Saturated liquid
A saturated liquid is liquid at the exact condition where boiling is about to begin.
Two-phase mixture
Once boiling begins, liquid and vapor coexist. The system lies inside the saturation dome.
Saturated vapor
A saturated vapor is vapor at the exact condition where the last liquid droplet has just disappeared.
Superheated vapor
Additional heating after complete vaporization produces superheated vapor. Its temperature is higher than the saturation temperature at the given pressure.
Quality
Quality, represented by x, is the mass fraction of vapor in a saturated liquid-vapor mixture:
x=mtotalmvaporThus:
- x=0: saturated liquid
- x=1: saturated vapor
- 0<x<1: wet mixture
For a two-phase mixture, a property such as enthalpy can be found from
h=hf+xhfgwhere
hfg=hg−hfEquivalently,
x=hg−hfh−hfThe same mixture relation applies to other properties, such as internal energy, specific volume, and entropy:
u=uf+xufg v=vf+xvfg s=sf+xsfgQuality has meaning only inside the two-phase region. A compressed liquid and a superheated vapor do not have quality values.
The pressure-volume diagram
A P-v diagram plots pressure vertically and specific volume horizontally.
The saturation dome divides the diagram into regions:
- Left of the dome: compressed liquid
- Inside the dome: liquid-vapor mixture
- Right of the dome: superheated vapor
Inside the two-phase region, pressure and temperature are linked. Knowing one determines the other through saturation data.
The top of the dome is the critical point. Above the critical point, distinct liquid and vapor phases no longer exist. For water, the critical point is approximately:
Tc=374∘C Pc=22.1 MPaModern power plants may operate above the critical point in the supercritical region, but introductory analyses generally remain below or beside the critical point.
Steam Tables and Property Evaluation
Property tables provide experimentally based values for water and steam. The most important tables are:
- Saturated water—temperature table
- Saturated water—pressure table
- Superheated water-vapor table
Saturated temperature table
Use this table when temperature is known and the state is saturated.
Each temperature row commonly contains:
- Saturation pressure
- vf and vg
- uf, ug, and ufg
- hf, hg, and hfg
- sf, sg, and sfg
The subscript f refers to saturated liquid. The subscript g refers to saturated vapor. The subscript fg refers to the difference between vapor and liquid values:
hfg=hg−hfSaturated pressure table
This table contains the same types of information, but the rows are organized by pressure instead of temperature.
Superheated vapor table
The superheated table is divided into smaller tables, usually one for each pressure. Within each small table, temperature determines the row.
Compressed-liquid approximation
Compressed-liquid tables may be small or omitted. Because liquid water is nearly incompressible, compressed-liquid properties are often approximated using the saturated-liquid property at the same temperature:
vcompressed liquid≈vf(T)The temperature must match. Using the saturated-liquid value at the given pressure is not the standard approximation because pressure has little influence on liquid properties compared with temperature.
The table-selection workflow
Every property-table problem follows the same logic:
- Identify the substance.
- Determine the phase.
- Choose the correct table.
- Read the value or interpolate between values.
When the phase is uncertain, check the saturation temperature or saturation pressure first.
- If the actual temperature is greater than the saturation temperature at that pressure, the state is superheated vapor.
- If the actual temperature is less than the saturation temperature at that pressure, the state is compressed liquid.
- If the condition lies between the saturated-liquid and saturated-vapor values, it is a two-phase mixture.
Interpolation
If a value lies between two table entries, interpolation estimates the value between them.
For a property y at an intermediate variable x,
x2−x1x−x1=y2−y1y−y1For example, if 101∘C lies between 100∘C and 105∘C,
105−100101−100=0.2The corresponding enthalpy is therefore 20% of the way from the value at 100∘C to the value at 105∘C.
For a mixture with quality x=0.6, the property must be 60% of the way from the saturated-liquid value to the saturated-vapor value:
hg−hfh−hf=0.6The fraction approach reinforces the physical meaning of quality and reduces sign mistakes.
Different textbooks may use slightly different property values because their tables are based on different data correlations. The differences are usually small, but values from different table sets should not be mixed within one problem.
Ideal Gases and Compressibility
For gases such as air, nitrogen, oxygen, and carbon dioxide, the ideal-gas equation is often more convenient than property tables.
The general equation is
PV=mRTUsing specific volume,
Pv=RTwhere:
- P is absolute pressure.
- V is total volume.
- v is specific volume.
- m is mass.
- T is absolute temperature.
- R is the specific gas constant for the particular gas.
The universal gas constant is written differently and is used with molar quantities:
Rˉ=8.314 kJ/(kmol⋅K)The specific gas constant is related to molar mass by
R=MRˉThe units must be checked carefully so that all terms are compatible.
When the ideal-gas model is appropriate
The ideal-gas approximation works best when the gas is:
- At low pressure
- At high temperature
- Far from the saturation dome
Air near atmospheric pressure is usually modeled well as an ideal gas. High-pressure steam near saturation should generally be evaluated with steam tables instead.
For constant mass and constant gas constant, the ideal-gas law can be used in ratio form:
T1P1V1=T2P2V2or, using specific volume,
T1P1v1=T2P2v2If a tank is rigid, then
V1=V2and the volume cancels. At constant volume,
T1P1=T2P2Therefore, doubling absolute pressure doubles absolute temperature.
Compressibility factor
Real gases deviate from ideal behavior. The compressibility factor, Z, corrects the ideal-gas relation:
Pv=ZRTFor an ideal gas,
Z=1A real gas may have Z above or below 1, depending on pressure and temperature.
To use a generalized compressibility chart, calculate reduced properties:
Pr=PcP Tr=TcTwhere Pc and Tc are the critical pressure and temperature of the gas.
The chart uses Pr and Tr to determine Z. If Z is close to 1, the ideal-gas model is probably adequate. If it differs substantially from 1, the correction is important.
The three main approaches are:
- Property tables: most accurate
- Compressibility chart: approximate but often useful
- Ideal-gas law: easiest but least accurate when non-ideal effects matter
Think About It
Why might an ideal-gas calculation be unsafe for a high-pressure carbon-dioxide storage container?
Boundary Work in Closed Systems
For a piston-cylinder, the most common work mode is moving-boundary work.
When a gas pushes a piston, the force on the piston is related to pressure:
F=PAThe differential work is
δW=Fdx=PAdxSince
dV=Adxthe boundary work becomes
δW=PdVand the total work is
Wb=∫V1V2PdVThe units confirm that pressure times volume is energy:
Pa⋅m3=m2N⋅m3=N⋅m=JWork on a P-V diagram
Boundary work is the area under the process curve on a P-V diagram.
- Expansion moves to the right and gives Wb>0.
- Compression moves to the left and gives Wb<0.
- A constant-volume process is vertical, so the area is zero and Wb=0.
Work is path dependent. Two processes can connect the same initial and final states but have different areas under their curves. Therefore, work is not a property of the state.
Common process models
Isochoric process
An isochoric process has constant volume:
V=constantBecause dV=0,
Wb=0Isobaric process
An isobaric process has constant pressure:
P=constantThe work is the rectangular area:
Wb=P(V2−V1)Polytropic process
A polytropic process follows
PVn=Cwhere n is the polytropic exponent and C is a constant.
The endpoint relationship is
P1V1n=P2V2nFor n=1,
Wb=1−nP2V2−P1V1Isothermal ideal-gas process
For constant temperature,
PV=mRT=constantThis corresponds to a polytropic process with
n=1For an ideal gas,
Wb=mRTln(V1V2)The logarithm is the natural logarithm.
Adiabatic ideal-gas process
An ideal-gas adiabatic process is modeled as polytropic with
n=kwhere
k=CvCpFor air, k is approximately 1.4.
The Otto cycle
A four-stroke gasoline engine follows the Otto cycle model:
- Intake
- Compression
- Ignition and power stroke
- Exhaust
Compression involves work done on the gas, so the work is negative. The hot gas expands during the power stroke and does positive work. On a P-V diagram, the area enclosed by the cycle represents net work output.
Specific Heats and Ideal-Gas Energy Changes
Specific heat measures the energy required per unit mass to change a substance’s temperature by one degree.
For gases, two values are used:
- Cv: specific heat at constant volume
- Cp: specific heat at constant pressure
For an ideal gas, internal energy depends only on temperature:
Δu=Cv(T2−T1)Thus,
ΔU=mCvΔTEnthalpy also depends only on temperature:
Δh=Cp(T2−T1)Thus,
ΔH=mCpΔTThe key rule is:
- To calculate internal-energy change, use Cv.
- To calculate enthalpy change, use Cp.
This rule applies even if the physical process itself is not constant volume or constant pressure.
For ideal gases,
Cp=Cv+RTherefore, Cp is greater than Cv. Heating a gas at constant pressure requires extra energy because the gas expands and performs boundary work.
For liquids and solids, compressibility is small, so a single specific heat is usually used.
Specific heats vary somewhat with temperature. Over a small temperature range, they may be treated as constant. Over a large range, an average value based on the initial and final temperatures provides a better approximation.
Calorimetry
Calorimetry measures specific heat using energy conservation.
In an insulated container with no work,
Qtotal=0Heat lost by the hot object equals heat gained by the cooler object:
mhotchotΔThot+mcoldccoldΔTcold=0The unknown specific heat can be determined if the other quantities are measured.
At constant pressure, the heat-transfer shortcut is
Q=mCpΔTbecause the boundary work is already incorporated into Cp.
At constant volume, work is zero, so
Q=ΔU=mCvΔTThese shortcuts are especially useful on timed examinations.
Open Systems and the Steady-Flow Energy Equation
An open system, or control volume, allows mass to cross its boundary.
Conservation of mass
Mass cannot be created or destroyed. The general rate balance is
dtdmCV=∑m˙in−∑m˙outAt steady state,
dtdmCV=0so
∑m˙in=∑m˙outFor one inlet and one outlet,
m˙in=m˙outThe mass flow rate can be written in several equivalent ways:
m˙=ρAVSince v=1/ρ,
m˙=vAVHere, V may represent flow velocity, while v represents specific volume. Units are the safest way to distinguish these quantities.
Energy carried by flowing mass
Flowing mass carries:
- Internal energy
- Kinetic energy
- Potential energy
- Flow work
Enthalpy combines internal energy and flow work:
h=u+PvThis is why enthalpy is the natural property for open-system analysis.
Steady-flow energy equation
For a single-inlet, single-outlet steady-flow device,
Q˙−W˙=m˙[(h2−h1)+2V22−V12+g(z2−z1)]The kinetic-energy term must be converted to compatible units. If velocity is in meters per second, then V2/2 is in joules per kilogram. If enthalpy is in kilojoules per kilogram, divide the kinetic-energy term by 1000.
When kinetic and potential energy changes are negligible,
Q˙−W˙=m˙(h2−h1)This simplified equation is used for most turbines, pumps, and heat exchangers.
Turbines
A turbine is usually:
- Steady state
- Adiabatic
- Negligible in kinetic and potential energy changes
Therefore,
W˙turbine,out=m˙(h1−h2)The enthalpy decreases because the fluid gives up energy to the shaft.
Pumps and compressors
A pump or compressor requires work input. Its outlet enthalpy is greater than its inlet enthalpy:
h2>h1Under the sign convention that work out is positive,
W˙pump=m˙(h1−h2)<0For incompressible liquid water, pump work is often approximated by
wpump≈v(P2−P1)Nozzles and diffusers
A nozzle accelerates a fluid. A diffuser decelerates it. Neither has a shaft, so
W˙=0They are commonly treated as adiabatic with negligible potential-energy change:
h1+2V12=h2+2V22A nozzle converts enthalpy into kinetic energy. A diffuser converts kinetic energy back into enthalpy.
Heat exchangers
A heat exchanger transfers heat between fluid streams through a wall. It has no shaft work:
W˙=0If the control volume surrounds only one stream,
Q˙=m˙(h2−h1)If the control volume surrounds both streams, heat transfer across the outer boundary is approximately zero:
Q˙external=0The heat lost by one stream equals the heat gained by the other.
Unsteady tank filling
A filling tank is not at steady state because mass and energy accumulate inside it.
For a rigid, insulated tank initially empty, with one inlet and no outlet:
- Q=0
- W=0
- m1=0
- No exit energy leaves
The energy balance reduces to
m2u2=minhinThe mass balance gives
m2=minTherefore,
u2=hinThis result can seem surprising: the final internal energy in the tank equals the incoming enthalpy. The incoming fluid brings both internal energy and flow work, and the flow-work contribution becomes internal energy in the tank.
Think About It
Why does enthalpy appear in the inlet term of a filling-tank problem, while internal energy describes the final contents of the tank?
The Second Law, Heat Engines, and Refrigerators
The first law addresses the quantity of energy. The second law addresses direction, quality, and limitations.
The first law alone would not prohibit heat from spontaneously moving from a cold room into a hot cup of coffee. The second law explains why natural processes have preferred directions.
Thermal reservoirs
A thermal reservoir is an idealized body capable of absorbing or rejecting very large amounts of heat without changing temperature.
- A reservoir supplying heat is a source.
- A reservoir absorbing heat is a sink.
The atmosphere and ocean can often be approximated as reservoirs.
Heat engines
A heat engine operates cyclically:
- It receives heat QH from a high-temperature source.
- It converts part of that heat into net work.
- It rejects the remaining heat QL to a low-temperature sink.
- It repeats.
The cycle energy balance is
QH=Wnet+QLor
Wnet=QH−QLThe thermal efficiency is
η=QHWnetKelvin–Planck statement
No cyclic heat engine can receive heat from only one reservoir and convert all of it into work. Some heat must be rejected to a lower-temperature sink.
Therefore, no heat engine can have
η=1This is why the condenser is not optional in a power plant.
Clausius statement
Heat does not naturally flow from cold to hot. Moving heat uphill from a cold reservoir to a hot reservoir requires external work.
This is the operating principle of refrigerators and heat pumps.
Refrigerators and heat pumps
A refrigerator removes heat from a cold space. Its useful output is QL:
COPR=WinQLA heat pump delivers heat to a warm space. Its useful output is QH:
COPHP=WinQHBecause
QH=QL+Winthe coefficients of performance satisfy
COPHP=COPR+1A coefficient of performance can exceed 1 because it measures heat moved, not heat created. A heat pump may deliver several units of heat for each unit of electrical work by extracting additional heat from the outdoor environment.
Perpetual-motion machines
A perpetual-motion machine of the first kind violates the first law by producing more energy than it receives.
A perpetual-motion machine of the second kind violates the second law by converting heat completely into work or moving heat from cold to hot without work input.
Both are impossible.
Reversible and irreversible processes
A reversible process is an ideal process that can be undone without leaving any trace in the system or surroundings. It is frictionless and represents the maximum possible performance.
An irreversible process includes real-world losses such as:
- Friction
- Unrestrained expansion
- Heat transfer across a finite temperature difference
- Mixing
- Electrical resistance
- Chemical reactions
An impossible process would exceed the reversible limit or violate the second law.
The Carnot Cycle
The Carnot cycle establishes the maximum possible performance of a heat engine operating between two temperature reservoirs.
It consists of four reversible processes:
- Isothermal expansion at the hot temperature
- Adiabatic expansion
- Isothermal compression at the cold temperature
- Adiabatic compression
The maximum thermal efficiency is
ηCarnot=1−THTLwhere TH and TL are absolute temperatures in Kelvin or Rankine.
Celsius and Fahrenheit cannot be used in this equation.
The Carnot efficiency increases when:
- TH increases
- TL decreases
This explains why engineers seek higher boiler temperatures and colder condenser temperatures.
The Carnot limits for a refrigerator and heat pump are
COPR,Carnot=TH−TLTLand
COPHP,Carnot=TH−TLTHActual devices must perform below these limits.
A practical engine related to the Carnot concept is the Stirling cycle, which uses two isothermal processes and two constant-volume processes. It can operate from an external temperature difference without internal combustion, but it still cannot achieve the ideal Carnot limit.
Performance comparison
To classify a real heat engine:
- Calculate actual efficiency.
- Calculate Carnot efficiency.
- Compare the two.
- Actual efficiency below Carnot: possible and irreversible.
- Actual efficiency equal to Carnot: reversible idealization.
- Actual efficiency above Carnot: impossible or indicative of an error.
Entropy
Entropy is a thermodynamic property used to quantify the direction of processes and the effect of irreversibility.
Third law
The third law states that the entropy of a perfect crystal at absolute zero is zero:
S=0at T=0 KThis supplies a reference point for entropy values.
Classical definition
For a reversible process,
dS=TδQrevor, for a finite reversible process,
ΔS=∫TδQrevThe classical engineering interpretation focuses on how heat transfer and temperature affect entropy.
Statistical interpretation
The statistical interpretation connects entropy with the number of microscopic arrangements corresponding to a macroscopic state. More possible microscopic arrangements correspond to greater entropy.
Regardless of interpretation, engineering problems treat entropy as a property, just like internal energy or enthalpy. For water and refrigerants, entropy is read from tables. For ideal gases, entropy changes are calculated with equations.
The T-s diagram
A T-s diagram plots temperature vertically and entropy horizontally.
It has the same general phase regions as the P-v diagram:
- Compressed liquid on the left
- Two-phase mixture under the dome
- Superheated vapor on the right
For a reversible process, the area under a T-s curve represents heat transfer:
Qrev=∫TdSThe Carnot cycle becomes a rectangle on a T-s diagram:
- Horizontal lines: isothermal heat-transfer processes
- Vertical lines: constant-entropy processes
Isentropic processes
An isentropic process has constant entropy:
ΔS=0A process is isentropic when it is both:
- Adiabatic
- Reversible
Thus,
adiabatic+reversible=isentropicFor an ideal turbine, pump, compressor, or nozzle, an isentropic assumption provides the ideal reference case.
For a turbine, knowing
s2=s1allows the exit state to be found. If the exit condition lies inside the saturation dome, quality is determined using
x=sg−sfs−sfThis is a central Rankine-cycle calculation.
Isentropic efficiency
Real machines are not perfectly reversible, even when they are approximately adiabatic.
For a turbine, the desired output is work output:
ηt=wisentropicwactualThe actual turbine produces less work than the ideal turbine.
For a pump or compressor, the desired result is minimum work input:
ηp=wactualwisentropicThe actual pump requires more work than the isentropic pump.
On a T-s diagram, real adiabatic components generally move to the right because entropy increases.
Entropy balance
The entropy balance includes entropy transfer and internal entropy generation. In rate form for a control volume,
dtdSCV=∑TjQ˙j+∑m˙insin−∑m˙outsout+S˙genThe entropy-generation rate satisfies
S˙gen≥0- S˙gen=0: reversible process
- S˙gen>0: irreversible process
- S˙gen<0: impossible result or calculation error
For a steady, insulated compressor with one inlet and one outlet, the entropy balance reduces to
S˙gen=m˙(s2−s1)Therefore, a physically possible process must have
s2≥s1Think About It
What does a negative entropy-generation result indicate about a proposed engineering process?
Complete Rankine-Cycle Analysis
The Rankine cycle can now be analyzed as four steady-flow control volumes.
Pump: state 1 to state 2
Typical assumptions:
- Steady state
- Adiabatic
- Negligible kinetic and potential energy changes
- Liquid approximately incompressible
For an ideal pump,
s2=s1The pump work is approximately
wp≈v1(P2−P1)The pump work is usually small because liquid water has a small specific volume.
Boiler: state 2 to state 3
Typical assumptions:
- Steady state
- No shaft work
- Negligible kinetic and potential energy changes
The heat added is
qin=h3−h2The boiler raises the fluid’s temperature, enthalpy, and generally entropy. During boiling under a fixed pressure, temperature remains at the saturation temperature while the phase changes.
Turbine: state 3 to state 4
Typical assumptions:
- Steady state
- Adiabatic
- Negligible kinetic and potential energy changes
For an ideal turbine,
s4=s3The ideal turbine work is
wt,isentropic=h3−h4sFor an actual turbine, the exit enthalpy is higher and the work output is lower. The turbine is the main work-producing component.
Condenser: state 4 to state 1
Typical assumptions:
- Steady state
- No shaft work
- Negligible kinetic and potential energy changes
The rejected heat is
qout=h4−h1The condenser returns the working fluid to liquid form. Heat rejection cannot be eliminated because the second law requires a low-temperature sink for a heat engine.
Overall thermal efficiency
The net work is
wnet=wt−wpThe thermal efficiency is
ηRankine=qinwt−wpThe most important practical observations are:
- Pump work is small.
- Boiler heat input is large.
- Turbine work output is the primary useful output.
- Condenser heat rejection is unavoidable.
- Small efficiency improvements in turbine performance can produce large economic benefits.
The most efficient problem-solving strategy is to identify the component being asked about and use only the two enthalpies that bound that component. Extra state data may be included as distractors.
Comprehensive Review
The complete logic of engineering thermodynamics can be summarized as follows:
- Choose a system. Decide whether the analysis uses a closed system or an open-system control volume.
- Identify the type of behavior. Determine whether the system is in equilibrium, steady state, transient operation, or quasi-equilibrium.
- Track mass and energy. Use mass conservation for open systems and the first law for energy.
- Use the correct energy property. Internal energy is central for closed systems; enthalpy is central for flowing open systems because it includes flow work.
- Apply the sign convention carefully. Heat entering and work leaving are positive under the chosen convention.
- Recognize keywords. Rigid implies no boundary work; insulated or adiabatic implies no heat transfer; steady state eliminates accumulation; isothermal means constant temperature; isentropic means constant entropy.
- Identify the phase. Compare the state with saturation conditions and locate it relative to the saturation dome.
- Choose the correct property tool. Use saturated tables, superheated tables, compressed-liquid approximations, ideal-gas equations, or compressibility corrections as appropriate.
- Calculate process work. For piston-cylinder systems, boundary work is the area under the P-V curve and depends on the path.
- Use the second law. Heat engines require heat rejection, refrigerators require work input, and entropy generation cannot be negative.
- Compare real and ideal devices. Reversible or isentropic performance is the upper limit; real machines are irreversible and perform below that limit.
- Return to the Rankine cycle. The pump raises pressure, the boiler adds heat, the turbine produces work, and the condenser rejects heat.
The Rankine cycle is not a collection of unrelated equations. It is one continuous application of conservation of mass, conservation of energy, phase-property evaluation, process analysis, and the second law of thermodynamics.

Ask anything