1. Thermodynamic Systems and the Rankine Cycle

Thermodynamics analyzes how energy, heat, and work interact with matter. A useful starting point is the steam power plant, because it combines many of the central ideas in one machine.

The Rankine Cycle

The Rankine cycle is the idealized cycle used by most steam power plants. The working fluid, usually water, circulates in a closed loop through four main components:

  1. Pump: state 1 →\rightarrow→ state 2

  2. Boiler: state 2 →\rightarrow→ state 3

  3. Turbine: state 3 →\rightarrow→ state 4

  4. Condenser: state 4 →\rightarrow→ state 1

1. Pump

The pump receives cold, low-pressure liquid water and raises it to a higher pressure.

  • State 1: low-pressure liquid

  • State 2: high-pressure liquid

  • The pump requires work input.

  • Pressurizing liquid requires much less energy than pressurizing vapor.

  • Pump work is small relative to the work produced by the turbine, but it should not automatically be neglected.

2. Boiler

The boiler adds heat to high-pressure liquid water.

The heat source may be:

  • Coal

  • Natural gas

  • Nuclear energy

  • Geothermal energy

  • Solar energy

Regardless of the source, the thermodynamic function is the same: heat converts the liquid into high-pressure, high-temperature steam.

  • State 2: high-pressure liquid

  • State 3: high-pressure vapor, usually superheated

  • Heat enters the system in the boiler.

3. Turbine

The turbine is the primary work-producing component.

High-energy steam expands through turbine blades, causing a shaft to rotate. The shaft drives an electrical generator.

  • State 3: high-pressure, high-energy steam

  • State 4: lower-pressure steam, often a liquid-vapor mixture

  • Work leaves the system.

  • The turbine is the “moneymaker” of the cycle.

4. Condenser

The condenser rejects heat to the environment and converts the low-energy steam back into liquid water.

  • State 4: low-pressure wet steam

  • State 1: low-pressure liquid

  • Heat leaves the system.

  • Condensation is important because liquid requires much less work to pump than vapor.

The visible white clouds from cooling towers are generally water vapor carrying rejected heat, not smoke or combustion pollution. Combustion pollution, when present, exits through a chimney.

The Rankine cycle is a closed loop: the working fluid returns to its initial state, while heat and work cross the system boundary.


2. Systems, Boundaries, and Control Volumes

System, Surroundings, and Boundary

A system is the mass or region selected for analysis.

  • System: everything inside the chosen boundary

  • Surroundings: everything outside the system

  • Boundary: the surface separating the system from its surroundings

The boundary may be real or imaginary and may be fixed, moving, rigid, insulated, or permeable to mass.

Open Systems

An open system, also called a control volume, permits both mass and energy to cross its boundary.

Examples include:

  • Pipes

  • Turbines

  • Pumps

  • Nozzles

  • Compressors

  • Heat exchangers

A control volume usually focuses on a fixed region in space while fluid flows through it.

Closed Systems

A closed system does not allow mass to cross its boundary, although energy may cross as heat or work.

Examples include:

  • Gas trapped in a piston-cylinder

  • A sealed tank

  • A fixed amount of fluid in a container

For a closed system:

  • Mass remains inside.

  • Heat may enter or leave.

  • Work may enter or leave.

Isolated Systems

An isolated system is a special type of closed system through which neither mass nor energy crosses the boundary.

An isolated system is typically described as:

  • Rigid: no boundary movement, so no boundary work

  • Insulated: no heat transfer

Important keyword implications:

  • Rigid: volume is constant and boundary work is zero.

  • Insulated: heat transfer is zero.

  • Adiabatic: heat transfer is zero, either because the boundary is insulated or because the process occurs too quickly for heat to transfer.

Choosing the System

The same physical device can be treated differently depending on the selected boundary.

  • A boundary around a turbine creates an open system because fluid enters and exits.

  • A boundary around an entire power plant may create a closed system if all working fluid remains inside the boundary.

  • The best system boundary is the one that makes the desired energy transfers easiest to analyze.


3. Thermodynamic Properties and States

A property is a measurable characteristic of a system.

Common Properties

The basic properties are:

  • Pressure, PPP

  • Temperature, TTT

  • Volume, VVV

Additional thermodynamic properties include:

  • Internal energy, UUU

  • Enthalpy, HHH

  • Entropy, SSS

Specific properties are properties per unit mass:

  • Specific volume: vvv

  • Specific internal energy: uuu

  • Specific enthalpy: hhh

  • Specific entropy: sss

Pressure

Thermodynamics uses absolute pressure, not gauge pressure.

The relationship is:

Pabsolute=Pgauge+PatmosphericP_{\text{absolute}}=P_{\text{gauge}}+P_{\text{atmospheric}}Pabsolute​=Pgauge​+Patmospheric​

Absolute pressure is measured relative to a perfect vacuum.

Temperature

Absolute temperature scales must be used in thermodynamic equations:

  • Kelvin in SI units

  • Rankine in English units

Celsius or Fahrenheit may be used for a temperature difference because temperature intervals have the same size relationship:

ΔTK=ΔT°C\Delta T_{\text{K}}=\Delta T_{\degree\text{C}}ΔTK​=ΔT°C​

However, absolute temperature must be used in equations such as the ideal gas law and Carnot efficiency.

Specific Volume and Density

Specific volume is volume per unit mass:

v=Vmv=\frac{V}{m}v=mV​

Density is mass per unit volume:

ρ=mV\rho=\frac{m}{V}ρ=Vm​

Therefore:

v=1ρv=\frac{1}{\rho}v=ρ1​

A high-density substance has a low specific volume, while a low-density substance has a high specific volume.

Equilibrium

A system is in thermodynamic equilibrium when it is uniform and unchanging, with no unbalanced driving forces.

Equilibrium generally implies that relevant properties are uniform throughout the system.

Steady State and Transient Behavior

A system is at steady state when its properties do not change with time at a fixed location.

A system is transient or unsteady when its properties change with time.

Steady state and equilibrium are not interchangeable:

  • A rod may have a constant temperature distribution in time but still have a hot side and a cold side. It is steady-state but not in thermal equilibrium.

  • A slowly leaking tire is transient, but each instant may be approximated as an equilibrium state. This is called quasi-equilibrium.

State

A state is a snapshot of a system described by its properties.

For example, pressure, temperature, and specific volume may describe the state of a fluid.

The Rankine cycle has four principal states, corresponding to the four major components.

The State Postulate

For a simple compressible substance, two independent intensive properties determine the state.

For example, knowing pressure and temperature allows the remaining properties to be obtained from property tables.

The two properties must be independent. In a saturated two-phase region, pressure and temperature are not independent because saturation pressure and saturation temperature are linked.

Processes and Cycles

A process is a change from one equilibrium state to another.

A cycle consists of a series of processes that returns the system to its original state.

For a cycle:

ΔUcycle=0\Delta U_{\text{cycle}}=0ΔUcycle​=0

This occurs because internal energy is a property. The system ends at the same state at which it began.


4. The Laws of Thermodynamics

The Zeroth Law

The zeroth law of thermodynamics establishes the concept of temperature.

If system AAA is in thermal equilibrium with system BBB, and system BBB is in thermal equilibrium with system CCC, then systems AAA and CCC are in thermal equilibrium with each other.

This is the transitive property of thermal equilibrium.

A thermometer acts as system BBB. If it gives the same reading for two objects, the objects have the same temperature.


The First Law: Conservation of Energy

The first law of thermodynamics is the principle of conservation of energy.

Energy cannot be created or destroyed; it can only be transferred or converted from one form to another.

Relevant forms of energy include:

Kinetic Energy

Kinetic energy results from motion:

KE=mV22KE=\frac{mV^2}{2}KE=2mV2​

Per unit mass:

ke=V22ke=\frac{V^2}{2}ke=2V2​

Potential Energy

Potential energy results from elevation in a gravitational field:

PE=mgzPE=mgzPE=mgz

Per unit mass:

pe=gzpe=gzpe=gz

Mechanical Work

Mechanical work is energy transferred by an applied force acting through a distance.

The simplest form is:

W=FΔxW=F\Delta xW=FΔx

Internal Energy

Internal energy is microscopic energy stored within a substance.

It includes the microscopic kinetic and potential energies associated with:

  • Molecular translation

  • Molecular rotation

  • Molecular vibration

  • Chemical bonds

  • Intermolecular interactions

Internal energy is represented by:

  • Total internal energy: UUU

  • Specific internal energy: uuu

Heating a substance generally increases its internal energy, but internal energy is not exactly the same as temperature. A substance can experience a change in internal energy even when its temperature remains constant, such as during phase change or certain gas processes.

For many engineering problems, changes in kinetic and potential energy are negligible, so internal energy is the primary stored-energy term.


Heat and Work

For a closed system, energy crosses the boundary in two distinct forms: heat and work.

Heat

Heat, QQQ, is energy transferred across a boundary solely because of a temperature difference.

Heat naturally transfers from hot to cold.

  • Heat entering the system is positive.

  • Heat leaving the system is negative.

  • If there is no temperature difference, there is no heat transfer.

Work

Work, WWW, is energy transferred across a boundary for any reason other than temperature difference.

Examples include:

  • Shaft rotation

  • Electrical current

  • Piston movement

  • Compression or expansion

  • Paddle-wheel work

Using the sign convention in these notes:

  • Work done by the system is positive.

  • Work done on the system is negative.

Rates of Heat and Work

The rate of heat transfer is:

Q˙=dQdt\dot Q=\frac{dQ}{dt}Q˙​=dtdQ​

The rate of work transfer is:

W˙=dWdt\dot W=\frac{dW}{dt}W˙=dtdW​

Both rates have units of power.

In SI units:

1 kW=1 kJ/s1\ \text{kW}=1\ \text{kJ/s}1 kW=1 kJ/s

In English units, heat-transfer rate may be measured in Btu/h, while work rate may be measured in horsepower.


Adiabatic Processes

An adiabatic process has no heat transfer:

Q=0Q=0Q=0

or, in rate form,

Q˙=0\dot Q=0Q˙​=0

An adiabatic process can occur because:

  1. The system is well insulated.

  2. The process happens so rapidly that heat has no time to cross the boundary.

A rapid compression can greatly increase internal energy and temperature because work enters the system while heat has not had time to escape.


Closed-System Energy Balance

For a closed system, the first law can initially be written as:

E2−E1=Q−WE_2-E_1=Q-WE2​−E1​=Q−W

The total energy is:

E=U+KE+PEE=U+KE+PEE=U+KE+PE

Therefore:

ΔU+ΔKE+ΔPE=Q−W\Delta U+\Delta KE+\Delta PE=Q-WΔU+ΔKE+ΔPE=Q−W

For a stationary closed system, changes in kinetic and potential energy are negligible:

ΔU=Q−W\boxed{\Delta U=Q-W}ΔU=Q−W​

This is the primary closed-system energy equation.

Sign-Convention Examples

Work by the system

If a gas expands and pushes a piston outward:

  • W>0W>0W>0

  • If no heat enters, Q=0Q=0Q=0

  • Therefore:

ΔU=−W\Delta U=-WΔU=−W

The gas loses internal energy while performing work.

Work on the system

If a paddle wheel or compressor does work on a fluid:

  • W<0W<0W<0

  • If heat enters, Q>0Q>0Q>0

Then:

ΔU=Q−W\Delta U=Q-WΔU=Q−W

Because WWW is negative, subtracting WWW increases the internal energy.

Keyword Strategy

Important words in a problem statement often eliminate terms:

  • Insulated: Q=0Q=0Q=0

  • Adiabatic: Q=0Q=0Q=0

  • Rigid: boundary work is zero

  • Steady state: no accumulation with time

  • Closed system: no mass crosses the boundary

  • Isothermal: temperature is constant

  • Constant pressure: use constant-pressure relationships

  • Constant volume: use constant-volume relationships


Thermal Efficiency

Thermal efficiency measures how effectively an energy-conversion device produces useful work.

η=desired outputrequired input\eta=\frac{\text{desired output}}{\text{required input}}η=required inputdesired output​

Efficiency is dimensionless and satisfies:

0≤η≤10\leq \eta\leq 10≤η≤1

or 0%0\%0% to 100%100\%100%.

For a power plant:

ηth=Wnet,outQin\eta_{\text{th}}=\frac{W_{\text{net,out}}}{Q_{\text{in}}}ηth​=Qin​Wnet,out​​

For a Rankine cycle, pump work is work input and therefore has a negative sign under the convention used here:

Wnet,out=Wturbine,out−Wpump,inW_{\text{net,out}}=W_{\text{turbine,out}}-W_{\text{pump,in}}Wnet,out​=Wturbine,out​−Wpump,in​

Using heat input and heat rejection:

ηth=1−QoutQin\eta_{\text{th}} = 1-\frac{Q_{\text{out}}}{Q_{\text{in}}}ηth​=1−Qin​Qout​​

A real plant must reject some heat. A plant efficiency of 40%40\%40% means approximately 60%60\%60% of the supplied energy is rejected to the environment.


Steady-State Rate Energy Balance

Taking the time derivative of the closed-system energy equation gives a rate form.

For a steady-state closed system, stored internal energy is not changing, so heat and work rates balance:

Q˙=W˙\dot Q=\dot WQ˙​=W˙

when no other energy terms change.

For a power plant:

W˙net,out=Q˙in−Q˙out\dot W_{\text{net,out}} = \dot Q_{\text{in}}-\dot Q_{\text{out}}W˙net,out​=Q˙​in​−Q˙​out​

For example, if a plant receives 800 MW800\ \text{MW}800 MW and rejects 480 MW480\ \text{MW}480 MW:

W˙net,out=800−480=320 MW\dot W_{\text{net,out}}=800-480=320\ \text{MW}W˙net,out​=800−480=320 MW

The efficiency is:

η=320800=0.40=40%\eta=\frac{320}{800}=0.40=40\%η=800320​=0.40=40%

5. Pure Substances and Phase Behavior

Pure Substances

A pure substance has a fixed and uniform chemical composition.

Examples include:

  • Water

  • Nitrogen

  • Oxygen

  • Carbon dioxide

  • Refrigerant R134a

Water is especially important because it changes phase throughout the Rankine cycle.

Phases of Water

The three common phases are:

  • Solid

  • Liquid

  • Vapor

For water, the gas phase is generally called vapor.

Five Important Liquid-Vapor States

Compressed Liquid

A compressed liquid, also called a subcooled liquid, is a liquid at a temperature below its saturation temperature for its pressure.

Saturated Liquid

A saturated liquid is a liquid exactly at the condition where vaporization is about to begin.

Its quality is:

x=0x=0x=0

Two-Phase Mixture

A two-phase mixture contains liquid and vapor simultaneously.

It exists beneath the saturation dome.

Saturated Vapor

A saturated vapor is vapor exactly at the condition where condensation is about to begin.

Its quality is:

x=1x=1x=1

Superheated Vapor

A superheated vapor is vapor at a temperature above its saturation temperature for a given pressure.

Superheated steam has relatively high energy and is desirable at the turbine inlet.


Quality

Quality, xxx, is the mass fraction of vapor in a saturated liquid-vapor mixture:

x=mgmf+mgx=\frac{m_g}{m_f+m_g}x=mf​+mg​mg​​

where mgm_gmg​ is vapor mass and mfm_fmf​ is liquid mass.

Quality ranges from 000 to 111:

  • x=0x=0x=0: saturated liquid

  • 0<x<10<x<10<x<1: wet mixture

  • x=1x=1x=1: saturated vapor

For any specific property yyy in the two-phase region:

y=yf+x(yg−yf)y=y_f+x(y_g-y_f)y=yf​+x(yg​−yf​)

Equivalently:

y=yf+xyfgy=y_f+x y_{fg}y=yf​+xyfg​

where:

  • yfy_fyf​ is the saturated-liquid value

  • ygy_gyg​ is the saturated-vapor value

  • yfg=yg−yfy_{fg}=y_g-y_fyfg​=yg​−yf​

For enthalpy:

h=hf+x(hg−hf)h=h_f+x(h_g-h_f)h=hf​+x(hg​−hf​)

Thus:

x=h−hfhg−hfx=\frac{h-h_f}{h_g-h_f}x=hg​−hf​h−hf​​

Quality has meaning only inside the two-phase region. It is not defined for compressed liquids or superheated vapors.


The Pressure-Volume Diagram

A PPP-vvv diagram plots:

  • Pressure on the vertical axis

  • Specific volume on the horizontal axis

For a pure substance, the phase boundaries form a saturation dome.

Regions of the Saturation Dome

  • Left of the dome: compressed liquid

  • Inside the dome: saturated liquid-vapor mixture

  • Right of the dome: superheated vapor

  • Top of the dome: critical point

Inside the two-phase region, pressure and temperature are linked. If one is known, the other is automatically determined through saturation relations.

Critical Point

At the critical point, liquid and vapor become indistinguishable.

For water, the critical point is approximately:

  • Temperature: 374∘C374^\circ\text{C}374∘C

  • Pressure: 22.1 MPa22.1\ \text{MPa}22.1 MPa

Above the critical point, there is no distinct boiling process with separate liquid and vapor bubbles. This is the supercritical region.

Rankine States on the PPP-vvv Diagram

  • State 1: saturated liquid leaving the condenser

  • State 2: compressed liquid after the pump

  • State 3: superheated vapor leaving the boiler

  • State 4: wet vapor mixture leaving the turbine


6. Enthalpy and Property Tables

Enthalpy

Enthalpy is defined as:

H=U+PVH=U+PVH=U+PV

Specific enthalpy is:

h=u+Pvh=u+Pvh=u+Pv

The PvPvPv term represents flow work, the work required for flowing fluid to push itself through a pipe or control volume.

Because flow work naturally accompanies mass crossing a boundary, enthalpy is especially useful for open systems.

  • Closed systems generally use internal energy, UUU or uuu.

  • Flowing open systems generally use enthalpy, HHH or hhh.

Enthalpy has units of energy:

  • Total enthalpy: kJ

  • Specific enthalpy: kJ/kg


Steam Tables

Property tables provide values such as:

  • Pressure

  • Temperature

  • Specific volume

  • Internal energy

  • Enthalpy

  • Entropy

For water, the most frequently used tables are:

Saturated Water—Temperature Table

Use this table when:

  • Temperature is known.

  • The fluid is saturated or suspected to be saturated.

Each temperature row provides the saturation pressure and saturated-liquid and saturated-vapor properties.

Saturated Water—Pressure Table

Use this table when:

  • Pressure is known.

  • The fluid is saturated or suspected to be saturated.

The information is the same as the saturation-temperature table, but the rows are organized by pressure.

Superheated Water-Vapor Table

Use this table when the fluid is superheated.

The table is divided into pressure sub-tables, with temperature rows within each pressure table.

Compressed-Liquid Table

Compressed-liquid tables exist but are often not needed.

For water, compressed-liquid properties are commonly approximated using the saturated-liquid property at the same temperature:

vcompressed liquid(T,P)≈vf(T)v_{\text{compressed liquid}}(T,P) \approx v_f(T)vcompressed liquid​(T,P)≈vf​(T)

The temperature is used rather than pressure because liquid water is nearly incompressible.


Table-Selection Procedure

A reliable property-table procedure is:

  1. Identify the fluid.

  2. Determine the phase.

  3. Choose the appropriate table.

  4. Interpolate if the exact value is not listed.

  5. Check that the result is physically reasonable.

Phase Identification

Compare the given pressure and temperature to saturation conditions.

  • If T>TsatT>T_{\text{sat}}T>Tsat​ at the given pressure, the fluid is superheated vapor.

  • If T<TsatT<T_{\text{sat}}T<Tsat​ at the given pressure, the fluid is compressed liquid.

  • If the state is specified as saturated or has 0<x<10<x<10<x<1, use the saturation table.

  • If the pressure is below the saturation pressure at the given temperature, the fluid is generally superheated.

  • If the pressure is above the saturation pressure at the given temperature, the fluid is generally compressed liquid.

Interpolation

Interpolation estimates a property between two tabulated values.

If XXX lies between X1X_1X1​ and X2X_2X2​, and the desired property YYY lies between Y1Y_1Y1​ and Y2Y_2Y2​:

X−X1X2−X1=Y−Y1Y2−Y1\frac{X-X_1}{X_2-X_1} = \frac{Y-Y_1}{Y_2-Y_1}X2​−X1​X−X1​​=Y2​−Y1​Y−Y1​​

The corresponding values must remain in matching positions on both sides of the equation.

For example, a temperature of 101∘C101^\circ\text{C}101∘C is 20%20\%20% of the way from 100∘C100^\circ\text{C}100∘C to 105∘C105^\circ\text{C}105∘C:

101−100105−100=0.2\frac{101-100}{105-100}=0.2105−100101−100​=0.2

The desired enthalpy must therefore be 20%20\%20% of the way between the enthalpies at 100∘C100^\circ\text{C}100∘C and 105∘C105^\circ\text{C}105∘C.

Table Consistency

Different textbooks may list slightly different property values because they use different experimental correlations. The differences are usually small.

  • Use the tables provided for the problem.

  • Do not mix values from different table sets within one problem.


7. Ideal-Gas Relations and Compressibility

Ideal-Gas Equation of State

For gases at sufficiently low pressure or high temperature, the ideal-gas model is useful:

PV=mRTPV=mRTPV=mRT

Using specific volume:

Pv=RTPv=RTPv=RT

where:

  • PPP is absolute pressure

  • VVV is total volume

  • vvv is specific volume

  • mmm is mass

  • TTT is absolute temperature

  • RRR is the specific gas constant

Gas Constants

The specific gas constant depends on the gas.

The universal gas constant is:

Rˉ=8.314 kJkmol⋅K\bar R=8.314\ \frac{\text{kJ}}{\text{kmol}\cdot\text{K}}Rˉ=8.314 kmol⋅KkJ​

The specific gas constant is found from:

R=RˉMR=\frac{\bar R}{M}R=MRˉ​

where MMM is molar mass.

The universal gas constant should not be substituted directly into PV=mRTPV=mRTPV=mRT unless the equation is written in a molar form.

Validity of the Ideal-Gas Model

The ideal-gas assumption is most accurate when:

  • Pressure is low.

  • Temperature is high.

  • The state is far from the saturation dome.

Air near atmospheric pressure is usually modeled well as an ideal gas. High-pressure steam near saturation should generally be evaluated with steam tables instead.

Boyle’s Law

At constant temperature for a fixed mass of ideal gas:

PV=constantPV=\text{constant}PV=constant

Therefore:

P1V1=P2V2P_1V_1=P_2V_2P1​V1​=P2​V2​

If pressure increases, volume decreases.

Constant-Mass, Constant-Gas-Constant Relation

For fixed mmm and RRR:

P1V1T1=P2V2T2\frac{P_1V_1}{T_1} = \frac{P_2V_2}{T_2}T1​P1​V1​​=T2​P2​V2​​

Using specific volume:

P1v1T1=P2v2T2\frac{P_1v_1}{T_1} = \frac{P_2v_2}{T_2}T1​P1​v1​​=T2​P2​v2​​

A rigid tank has constant volume:

V1=V2V_1=V_2V1​=V2​

so:

P1T1=P2T2\frac{P_1}{T_1} = \frac{P_2}{T_2}T1​P1​​=T2​P2​​

At constant volume, doubling absolute pressure doubles absolute temperature.


Compressibility Factor

Real gases deviate from ideal behavior, especially at high pressure or near saturation.

The compressibility factor is:

Z=PvRTZ=\frac{Pv}{RT}Z=RTPv​

For an ideal gas:

Z=1Z=1Z=1

For a real gas:

  • ZZZ close to 111: ideal-gas approximation is reasonable.

  • ZZZ significantly different from 111: real-gas correction is needed.

The corrected equation is:

Pv=ZRTPv=ZRTPv=ZRT

Generalized Compressibility Chart

To use the chart, calculate reduced properties:

Tr=TTcT_r=\frac{T}{T_c}Tr​=Tc​T​
Pr=PPcP_r=\frac{P}{P_c}Pr​=Pc​P​

where TcT_cTc​ and PcP_cPc​ are the critical temperature and pressure of the gas.

The procedure is:

  1. Look up TcT_cTc​ and PcP_cPc​.

  2. Calculate TrT_rTr​ and PrP_rPr​.

  3. Locate PrP_rPr​ on the chart.

  4. Follow the curve corresponding to TrT_rTr​.

  5. Read ZZZ.

  6. Use Pv=ZRTPv=ZRTPv=ZRT.

Three Property-Evaluation Methods

From most accurate to least accurate:

  1. Property tables: generally treated as the most accurate.

  2. Compressibility chart: useful for real-gas corrections but limited in precision.

  3. Ideal-gas equation: easiest, but least accurate when real-gas effects are significant.


8. Closed Systems and Boundary Work

Moving-Boundary Work

Moving-boundary work occurs when a piston moves because of pressure acting on a boundary.

The differential work is:

δW=P dV\delta W=P\,dVδW=PdV

For a process from state 1 to state 2:

W1→2=∫V1V2P dVW_{1\rightarrow 2} = \int_{V_1}^{V_2}P\,dVW1→2​=∫V1​V2​​PdV

For specific work:

w1→2=∫v1v2P dvw_{1\rightarrow 2} = \int_{v_1}^{v_2}P\,dvw1→2​=∫v1​v2​​Pdv

Physical Derivation

Mechanical work is force times distance:

δW=F dx\delta W=F\,dxδW=Fdx

For a piston:

F=PAF=PAF=PA

Therefore:

δW=PA dx\delta W=PA\,dxδW=PAdx

Since:

A dx=dVA\,dx=dVAdx=dV

the boundary-work relation becomes:

δW=P dV\delta W=P\,dVδW=PdV

Pressure multiplied by volume has units of energy.

Work on a PPP-VVV Diagram

Boundary work equals the area under the process curve on a PPP-VVV diagram.

  • Expansion to the right: W>0W>0W>0

  • Compression to the left: W<0W<0W<0

Work is path dependent. Two processes can connect the same initial and final states but produce different work because their paths differ.

Pressure, temperature, and internal energy are properties; work is not a property.


Common Boundary-Work Processes

Constant-Volume Process

A constant-volume or isochoric process is represented by a vertical line.

Since dV=0dV=0dV=0:

W=∫P dV=0W=\int P\,dV=0W=∫PdV=0

Constant-Pressure Process

A constant-pressure or isobaric process is represented by a horizontal line.

W=P(V2−V1)W=P(V_2-V_1)W=P(V2​−V1​)

The area is a rectangle.

Polytropic Process

A polytropic process follows:

PVn=CPV^n=CPVn=C

where:

  • nnn is the polytropic exponent

  • CCC is a constant

For n≠1n\neq 1n=1:

W=P2V2−P1V11−nW= \frac{P_2V_2-P_1V_1}{1-n}W=1−nP2​V2​−P1​V1​​

The process relation can be used to find an unknown endpoint property:

P1V1n=P2V2nP_1V_1^n=P_2V_2^nP1​V1n​=P2​V2n​

Isothermal Ideal-Gas Process

For a constant-temperature ideal-gas process:

PV=mRT=constantPV=mRT=\text{constant}PV=mRT=constant

The boundary work is:

W=mRTln⁡(V2V1)W=mRT\ln\left(\frac{V_2}{V_1}\right)W=mRTln(V1​V2​​)

Equivalently:

W=mRTln⁡(P1P2)W=mRT\ln\left(\frac{P_1}{P_2}\right)W=mRTln(P2​P1​​)

The natural logarithm is required.

Adiabatic Ideal-Gas Process

A reversible adiabatic ideal-gas process is a polytropic process with:

n=kn=kn=k

where:

k=CpCvk=\frac{C_p}{C_v}k=Cv​Cp​​

Thus:

PVk=constantPV^k=\text{constant}PVk=constant

An adiabatic process is not automatically reversible. Only an adiabatic reversible process is isentropic.


Closed-System Problem Procedure

For a typical closed-system problem:

  1. Identify the system.

  2. Determine the process type.

  3. Calculate boundary work from the process relation or the PPP-VVV area.

  4. Determine ΔU\Delta UΔU from property tables or specific heats.

  5. Apply:

ΔU=Q−W\Delta U=Q-WΔU=Q−W
  1. Check the signs and physical meaning of the result.

For a cycle:

∑ΔU=0\sum \Delta U=0∑ΔU=0

because the system returns to its initial state.


9. Specific Heats and Calorimetry

Specific Heat

Specific heat measures the energy required to change the temperature of a unit mass of material by one degree.

For gases:

  • CvC_vCv​: specific heat at constant volume

  • CpC_pCp​: specific heat at constant pressure

Units commonly include:

kJkg⋅K\frac{\text{kJ}}{\text{kg}\cdot\text{K}}kg⋅KkJ​

For an ideal gas, internal energy and enthalpy depend only on temperature.

Internal Energy of an Ideal Gas

Δu=Cv(T2−T1)\Delta u=C_v(T_2-T_1)Δu=Cv​(T2​−T1​)

For a fixed mass:

ΔU=mCv(T2−T1)\Delta U=mC_v(T_2-T_1)ΔU=mCv​(T2​−T1​)

Enthalpy of an Ideal Gas

Δh=Cp(T2−T1)\Delta h=C_p(T_2-T_1)Δh=Cp​(T2​−T1​)

For a fixed mass:

ΔH=mCp(T2−T1)\Delta H=mC_p(T_2-T_1)ΔH=mCp​(T2​−T1​)

The subscript is chosen according to the property being found:

  • Finding internal energy: use CvC_vCv​.

  • Finding enthalpy: use CpC_pCp​.

The subscripts do not mean that the process itself must occur at constant volume or constant pressure.

Relationship Between CpC_pCp​, CvC_vCv​, and RRR

For an ideal gas:

Cp=Cv+RC_p=C_v+RCp​=Cv​+R

Therefore:

Cv=Cp−RC_v=C_p-RCv​=Cp​−R

Since R>0R>0R>0:

Cp>CvC_p>C_vCp​>Cv​

At constant pressure, part of the supplied energy performs boundary work, so more energy is required per degree of temperature increase.

Specific-Heat Ratio

The specific-heat ratio is:

k=CpCvk=\frac{C_p}{C_v}k=Cv​Cp​​

Typical values include:

  • Air: k≈1.4k\approx 1.4k≈1.4

  • Monatomic gases: k≈1.67k\approx 1.67k≈1.67

The ratio kkk appears in reversible adiabatic processes and compressible-flow relations.

Temperature Dependence

Specific heats vary somewhat with temperature.

  • For small temperature changes, constant values are usually acceptable.

  • For changes of several hundred degrees, using an average of the initial and final values improves the estimate.


Calorimetry

Calorimetry measures energy transfer through temperature changes.

In an insulated container with no work:

Qtotal=0Q_{\text{total}}=0Qtotal​=0

Heat lost by a hot material equals heat gained by a cooler material:

mhotChotΔThot+mcoldCcoldΔTcold=0m_{\text{hot}}C_{\text{hot}}\Delta T_{\text{hot}} + m_{\text{cold}}C_{\text{cold}}\Delta T_{\text{cold}} =0mhot​Chot​ΔThot​+mcold​Ccold​ΔTcold​=0

Equivalently, in magnitude form:

mhotChot∣ΔThot∣=mcoldCcoldΔTcoldm_{\text{hot}}C_{\text{hot}}|\Delta T_{\text{hot}}| = m_{\text{cold}}C_{\text{cold}}\Delta T_{\text{cold}}mhot​Chot​∣ΔThot​∣=mcold​Ccold​ΔTcold​

This method can determine an unknown specific heat and identify a material by comparing it with property tables.


Constant-Pressure and Constant-Volume Shortcuts

At constant pressure:

Q=mCpΔTQ=mC_p\Delta TQ=mCp​ΔT

Boundary work is already included in the constant-pressure enthalpy relationship.

At constant volume, boundary work is zero:

W=0W=0W=0

Therefore:

Q=ΔU=mCvΔTQ=\Delta U=mC_v\Delta TQ=ΔU=mCv​ΔT

Recognizing the process can eliminate substantial algebra.


10. Open Systems and Control Volumes

Conservation of Mass

Mass is conserved:

Mass cannot appear or disappear; it can only accumulate, enter, or leave.

The mass flow rate is:

m˙=dmdt\dot m=\frac{dm}{dt}m˙=dtdm​

Common forms are:

m˙=ρAV\dot m=\rho A Vm˙=ρAV

and, since ρ=1/v\rho=1/vρ=1/v:

m˙=AVv\dot m=\frac{AV}{v}m˙=vAV​

where:

  • ρ\rhoρ is density

  • AAA is flow area

  • VVV is flow velocity

  • vvv is specific volume

Care must be taken to distinguish:

  • VVV: total volume or velocity, depending on context

  • vvv: specific volume

General Control-Volume Mass Balance

dmCVdt=∑m˙in−∑m˙out\frac{dm_{\text{CV}}}{dt} = \sum \dot m_{\text{in}} - \sum \dot m_{\text{out}}dtdmCV​​=∑m˙in​−∑m˙out​

At steady state:

dmCVdt=0\frac{dm_{\text{CV}}}{dt}=0dtdmCV​​=0

For one inlet and one outlet:

m˙in=m˙out\dot m_{\text{in}}=\dot m_{\text{out}}m˙in​=m˙out​

Control-Volume Energy Balance

Fluid crossing a boundary carries:

  • Internal energy

  • Flow work

  • Kinetic energy

  • Potential energy

Internal energy plus flow work is grouped as enthalpy:

h=u+Pvh=u+Pvh=u+Pv

The general control-volume energy balance includes heat transfer, work, enthalpy flow, kinetic energy, and potential energy.

For a steady-flow, single-inlet, single-outlet control volume:

Q˙−W˙=m˙[(h2−h1)+V22−V122+g(z2−z1)]\dot Q-\dot W = \dot m \left[ (h_2-h_1) + \frac{V_2^2-V_1^2}{2} + g(z_2-z_1) \right]Q˙​−W˙=m˙[(h2​−h1​)+2V22​−V12​​+g(z2​−z1​)]

This is the steady-flow energy equation, or SFEE.

If kinetic and potential energy changes are negligible:

Q˙−W˙=m˙(h2−h1)\boxed{\dot Q-\dot W=\dot m(h_2-h_1)}Q˙​−W˙=m˙(h2​−h1​)​

This simplified form applies to most turbine, pump, compressor, and heat-exchanger problems.


Turbines and Compressors

Turbines and compressors generally operate rapidly and are often approximated as adiabatic:

Q˙=0\dot Q=0Q˙​=0

Kinetic and potential energy changes are usually small.

Turbine

A turbine produces work:

W˙out=m˙(h1−h2)\dot W_{\text{out}} = \dot m(h_1-h_2)W˙out​=m˙(h1​−h2​)

Because enthalpy decreases through the turbine, work output is positive.

Pump or Compressor

A pump or compressor requires work input:

W˙in=m˙(h2−h1)\dot W_{\text{in}} = \dot m(h_2-h_1)W˙in​=m˙(h2​−h1​)

Under the sign convention where work leaving the system is positive:

W˙=−m˙(h2−h1)\dot W=-\dot m(h_2-h_1)W˙=−m˙(h2​−h1​)

Since h2>h1h_2>h_1h2​>h1​, the calculated work term is negative.


Nozzles and Diffusers

A nozzle accelerates fluid by converting enthalpy into kinetic energy.

A diffuser decelerates fluid and converts kinetic energy into enthalpy.

For a nozzle or diffuser:

  • No shaft work: W˙=0\dot W=0W˙=0

  • Usually adiabatic: Q˙=0\dot Q=0Q˙​=0

  • Usually negligible potential-energy change

The simplified balance is:

h1+V122=h2+V222h_1+\frac{V_1^2}{2} = h_2+\frac{V_2^2}{2}h1​+2V12​​=h2​+2V22​​

The kinetic-energy term must use consistent units. If velocity is in m/s, then V2/2V^2/2V2/2 is in J/kg and must be divided by 100010001000 to convert to kJ/kg.


Heat Exchangers

A heat exchanger transfers heat between two fluid streams through a wall.

For a control volume around one stream:

Q˙=m˙(h2−h1)\dot Q=\dot m(h_2-h_1)Q˙​=m˙(h2​−h1​)

For a control volume around the entire heat exchanger:

Q˙external=0\dot Q_{\text{external}}=0Q˙​external​=0

because heat remains inside the control volume. Therefore:

m˙hot(hhot,in−hhot,out)=m˙cold(hcold,out−hcold,in)\dot m_{\text{hot}}(h_{\text{hot,in}}-h_{\text{hot,out}}) = \dot m_{\text{cold}}(h_{\text{cold,out}}-h_{\text{cold,in}})m˙hot​(hhot,in​−hhot,out​)=m˙cold​(hcold,out​−hcold,in​)

The choice of control-volume boundary determines whether the inter-stream heat transfer appears as external heat transfer.


Unsteady Tank Filling

Filling and emptying tanks are transient control-volume problems.

For a rigid, insulated tank being filled with no outlet:

  • W=0W=0W=0

  • Q=0Q=0Q=0

  • m˙out=0\dot m_{\text{out}}=0m˙out​=0

  • Initial tank mass may be zero.

The mass balance gives:

m2=minm_2=m_{\text{in}}m2​=min​

The energy balance becomes:

m2u2=minhinm_2u_2=m_{\text{in}}h_{\text{in}}m2​u2​=min​hin​

Because m2=minm_2=m_{\text{in}}m2​=min​:

u2=hin\boxed{u_2=h_{\text{in}}}u2​=hin​​

The final internal energy in the tank equals the enthalpy supplied by the incoming stream. This can produce a final tank temperature higher than the inlet temperature because the incoming fluid’s flow work becomes internal energy in the tank.


11. The Second Law of Thermodynamics

First Law Versus Second Law

The first law concerns the quantity of energy:

  • Energy is conserved.

The second law concerns:

  • The direction of processes

  • The quality of energy

  • The impossibility of perfect energy conversion

  • Entropy generation

For example, the first law does not prohibit a cool room from transferring heat spontaneously into hot coffee. The second law explains why that process does not occur naturally.


Thermal Reservoirs

A thermal reservoir is an idealized body with such a large thermal capacity that it can absorb or reject heat without changing temperature.

  • A reservoir that supplies heat is a source.

  • A reservoir that absorbs heat is a sink.

The atmosphere and ocean can often be approximated as thermal reservoirs.


Heat Engines

A heat engine is a cyclic device that converts heat into work.

Every heat engine:

  1. Receives heat QHQ_HQH​ from a high-temperature source.

  2. Converts part of that energy into net work WnetW_{\text{net}}Wnet​.

  3. Rejects the remaining heat QLQ_LQL​ to a low-temperature sink.

  4. Repeats cyclically.

For a cycle:

QH=Wnet+QLQ_H=W_{\text{net}}+Q_LQH​=Wnet​+QL​

Thus:

Wnet=QH−QLW_{\text{net}}=Q_H-Q_LWnet​=QH​−QL​

The thermal efficiency is:

η=WnetQH\eta=\frac{W_{\text{net}}}{Q_H}η=QH​Wnet​​

or:

η=1−QLQH\eta=1-\frac{Q_L}{Q_H}η=1−QH​QL​​

Kelvin-Planck Statement

No cyclic heat engine can receive heat from a single reservoir and convert all of that heat into work. Some heat must always be rejected to a lower-temperature sink.

Consequences:

  • A heat engine cannot have 100%100\%100% efficiency.

  • A cold reservoir is necessary.

  • The condenser in a power plant is required by the second law.

  • Eliminating heat rejection would stop the engine.


Clausius Statement

Heat cannot spontaneously flow from a colder body to a hotter body.

Heat naturally flows from hot to cold. Moving heat from cold to hot requires external work.

This is the operating principle of:

  • Refrigerators

  • Heat pumps

  • Air conditioners


Refrigerators and Heat Pumps

A refrigerator and a heat pump use the same physical cycle. They differ only in the desired output.

Refrigerator

The useful output is heat removed from the cold region:

COPR=QLWin\text{COP}_{R}=\frac{Q_L}{W_{\text{in}}}COPR​=Win​QL​​

Heat Pump

The useful output is heat delivered to the hot region:

COPHP=QHWin\text{COP}_{HP}=\frac{Q_H}{W_{\text{in}}}COPHP​=Win​QH​​

Because:

QH=QL+WinQ_H=Q_L+W_{\text{in}}QH​=QL​+Win​

the coefficients of performance satisfy:

COPHP=COPR+1\boxed{\text{COP}_{HP}=\text{COP}_{R}+1}COPHP​=COPR​+1​

Coefficient of performance can exceed one because the device moves heat rather than converting all input work into heat.

A heat pump with a COP of 444 delivers four units of heat for every unit of electrical work.


Perpetual-Motion Machines

Perpetual-Motion Machine of the First Kind

A PMM of the first kind violates the first law.

  • It produces more energy than it receives.

  • It creates energy from nothing.

  • It is impossible.

Perpetual-Motion Machine of the Second Kind

A PMM of the second kind violates the second law.

Examples include:

  • A heat engine with 100%100\%100% efficiency

  • A device that moves heat from cold to hot without work input

Both types are impossible.


Reversible and Irreversible Processes

Reversible Process

A reversible process is an ideal limiting process that can be completely undone without leaving a change in the system or surroundings.

Reversible processes are:

  • Frictionless

  • Infinitely slow or quasi-equilibrium

  • Free of mixing

  • Free of finite-temperature-difference heat transfer

A reversible process does not exist perfectly in the real world but provides the maximum theoretical performance.

Irreversible Process

An irreversible process includes losses such as:

  • Friction

  • Unrestrained expansion

  • Heat transfer across a finite temperature difference

  • Mixing of different fluids

  • Electrical resistance

  • Chemical reactions

  • Viscous effects

All real processes are irreversible to some degree.

Impossible Process

A process that exceeds the reversible limit or converts heat to work with 100%100\%100% efficiency violates the second law.


12. Carnot Cycle and Maximum Performance

Carnot Cycle

The Carnot cycle is a theoretical reversible heat-engine cycle operating between a hot reservoir and a cold reservoir.

It contains four reversible processes:

  1. Isothermal expansion at THT_HTH​

  2. Adiabatic expansion from THT_HTH​ to TLT_LTL​

  3. Isothermal compression at TLT_LTL​

  4. Adiabatic compression from TLT_LTL​ back to THT_HTH​

The Carnot cycle establishes the maximum possible efficiency for any engine operating between two temperatures.

Carnot Efficiency

ηCarnot=1−TLTH\boxed{\eta_{\text{Carnot}}=1-\frac{T_L}{T_H}}ηCarnot​=1−TH​TL​​​

Temperatures must be absolute:

  • Kelvin

  • Rankine

Celsius and Fahrenheit cannot be substituted directly.

The maximum efficiency increases when:

  • THT_HTH​ increases

  • TLT_LTL​ decreases

Engineering methods include:

  • Higher furnace or reactor temperature

  • Superheated or supercritical steam

  • Colder cooling water

  • Lower condenser pressure

  • Deep-ocean cooling

Carnot Coefficients of Performance

For a refrigerator:

COPR,Carnot=TLTH−TL\text{COP}_{R,\text{Carnot}} = \frac{T_L}{T_H-T_L}COPR,Carnot​=TH​−TL​TL​​

For a heat pump:

COPHP,Carnot=THTH−TL\text{COP}_{HP,\text{Carnot}} = \frac{T_H}{T_H-T_L}COPHP,Carnot​=TH​−TL​TH​​

The temperatures must again be absolute.

The Carnot cycle is theoretical. Real machines must operate below its performance limit.

Stirling Cycle

The Stirling cycle is a practical cycle related to the Carnot cycle.

It consists of:

  • Two isothermal processes

  • Two constant-volume processes

Stirling engines can operate using a temperature difference without internal combustion. They have applications in:

  • Early refrigeration

  • Spacecraft thermal management

  • Low-grade waste-heat recovery

They are efficient and quiet but cannot reach Carnot performance because real processes contain irreversibilities.


13. Entropy

Third Law of Thermodynamics

The entropy of a perfect crystal at absolute zero is exactly zero.

This establishes a reference point for entropy.


Classical Definition of Entropy

For a reversible process:

dS=δQrevTdS=\frac{\delta Q_{\text{rev}}}{T}dS=TδQrev​​

For a finite reversible process:

ΔS=∫δQrevT\Delta S=\int\frac{\delta Q_{\text{rev}}}{T}ΔS=∫TδQrev​​

Entropy is a property, so its change depends only on the initial and final states, even though the definition uses a reversible path.

For an isolated system:

ΔSisolated≥0\Delta S_{\text{isolated}}\geq 0ΔSisolated​≥0

The entropy of the universe never decreases.


Statistical Interpretation

The statistical interpretation, associated with Boltzmann, relates entropy to the number of microscopic arrangements compatible with a macroscopic state.

More possible molecular arrangements correspond to higher entropy.

Examples:

  • A substance with molecules arranged in a restricted configuration has lower entropy.

  • A dispersed substance or mixed system has higher entropy.

  • A gas spreading throughout a container increases entropy.

The classical and statistical interpretations describe entropy from different perspectives. The classical engineering approach focuses on measurable macroscopic properties, while the statistical approach focuses on microscopic arrangements and probability.


Entropy in Property Tables

Entropy is represented by:

  • Total entropy: SSS

  • Specific entropy: sss

It is listed in steam tables along with pressure, temperature, volume, internal energy, and enthalpy.

For saturated mixtures:

s=sf+x(sg−sf)s=s_f+x(s_g-s_f)s=sf​+x(sg​−sf​)

Therefore:

x=s−sfsg−sfx=\frac{s-s_f}{s_g-s_f}x=sg​−sf​s−sf​​

The same quality-interpolation method used for enthalpy applies to entropy.


The TTT-SSS Diagram

A TTT-sss diagram plots:

  • Temperature on the vertical axis

  • Specific entropy on the horizontal axis

It has the same general phase regions as the PPP-vvv diagram:

  • Compressed liquid on the left

  • Two-phase mixture under the dome

  • Superheated vapor on the right

Area on a TTT-sss Diagram

For a reversible process:

δqrev=T ds\delta q_{\text{rev}}=T\,dsδqrev​=Tds

Therefore, the area under a reversible process curve on a TTT-sss diagram represents heat transfer.

For a cycle:

  • Area under the upper process corresponds to heat input.

  • Area under the lower process corresponds to heat rejection.

  • Area enclosed by the cycle corresponds to net work.

The Carnot cycle appears as a rectangle on a TTT-sss diagram:

  • Horizontal lines: isothermal processes

  • Vertical lines: isentropic processes


Isentropic Processes

An isentropic process has constant entropy:

ΔS=0\Delta S=0ΔS=0

A process is isentropic when it is both:

  1. Adiabatic

  2. Reversible

Thus:

adiabatic+reversible⇒isentropic\text{adiabatic}+\text{reversible} \Rightarrow \text{isentropic}adiabatic+reversible⇒isentropic

Adiabatic alone does not guarantee constant entropy because irreversibilities can generate entropy.

On a TTT-sss diagram, an isentropic process is vertical.

Isentropic Ideal-Gas Relations

For an ideal gas undergoing a reversible adiabatic process:

PVk=constantPV^k=\text{constant}PVk=constant

Other useful relationships include:

T2T1=(V1V2)k−1\frac{T_2}{T_1} = \left(\frac{V_1}{V_2}\right)^{k-1}T1​T2​​=(V2​V1​​)k−1

and:

T2T1=(P2P1)k−1k\frac{T_2}{T_1} = \left(\frac{P_2}{P_1}\right)^{\frac{k-1}{k}}T1​T2​​=(P1​P2​​)kk−1​

Isentropic Efficiency

Real components are not perfectly reversible. Isentropic efficiency compares actual performance with ideal reversible performance.

Turbine Efficiency

A turbine seeks maximum work output:

ηt=WactualWisentropic=h1−h2,actualh1−h2s\eta_t = \frac{W_{\text{actual}}}{W_{\text{isentropic}}} = \frac{h_1-h_{2,\text{actual}}} {h_1-h_{2s}}ηt​=Wisentropic​Wactual​​=h1​−h2s​h1​−h2,actual​​

The actual turbine exit enthalpy is higher than the isentropic exit enthalpy:

h2,actual>h2sh_{2,\text{actual}}>h_{2s}h2,actual​>h2s​

Typical turbine isentropic efficiencies may be approximately 85%85\%85% to 90%90\%90%.

Pump or Compressor Efficiency

A pump or compressor seeks minimum work input:

ηp=WisentropicWactual=h2s−h1h2,actual−h1\eta_p = \frac{W_{\text{isentropic}}}{W_{\text{actual}}} = \frac{h_{2s}-h_1} {h_{2,\text{actual}}-h_1}ηp​=Wactual​Wisentropic​​=h2,actual​−h1​h2s​−h1​​

The actual exit enthalpy is higher:

h2,actual>h2sh_{2,\text{actual}}>h_{2s}h2,actual​>h2s​

The efficiency expression is inverted relative to the turbine because the desired outcome is minimum work input.

Rankine-Cycle Isentropic Analysis

For an ideal turbine:

s4s=s3s_{4s}=s_3s4s​=s3​

The turbine exit state is found by:

  1. Looking up s3s_3s3​.

  2. Setting s4s=s3s_{4s}=s_3s4s​=s3​.

  3. Using the exit pressure.

  4. Determining whether state 4 is superheated or a two-phase mixture.

  5. If two-phase, calculating quality from:

x=s−sfsg−sfx=\frac{s-s_f}{s_g-s_f}x=sg​−sf​s−sf​​
  1. Finding h4sh_{4s}h4s​ from the quality.


Entropy Generation

The entropy balance includes entropy generation caused by irreversibilities.

For a control volume, entropy can:

  • Accumulate inside the control volume

  • Enter with heat transfer

  • Enter with mass flow

  • Leave with mass flow

  • Be generated internally

The entropy-generation rate is S˙gen\dot S_{\text{gen}}S˙gen​.

The second law requires:

S˙gen≥0\boxed{\dot S_{\text{gen}}\geq 0}S˙gen​≥0​

Interpretation:

  • S˙gen>0\dot S_{\text{gen}}>0S˙gen​>0: irreversible, real process

  • S˙gen=0\dot S_{\text{gen}}=0S˙gen​=0: reversible ideal process

  • S˙gen<0\dot S_{\text{gen}}<0S˙gen​<0: impossible process or calculation error

Entropy generation measures the departure from reversible performance.

For a steady, adiabatic, single-inlet, single-outlet device:

S˙gen=m˙(s2−s1)\dot S_{\text{gen}} = \dot m(s_2-s_1)S˙gen​=m˙(s2​−s1​)

Per unit mass:

sgen=s2−s1s_{\text{gen}}=s_2-s_1sgen​=s2​−s1​

A negative result signals an impossible design or an incorrect calculation.


14. Complete Rankine-Cycle Analysis

The Rankine cycle combines the energy, property, open-system, and entropy tools.

Component 1: Pump

The pump raises the pressure of saturated liquid water.

Typical assumptions:

  • Steady state

  • Adiabatic

  • Negligible kinetic and potential energy changes

  • Nearly incompressible liquid

For an ideal isentropic pump:

s2=s1s_2=s_1s2​=s1​

For incompressible liquid, pump work can be approximated by:

wpump≈v1(P2−P1)w_{\text{pump}}\approx v_1(P_2-P_1)wpump​≈v1​(P2​−P1​)

The pump work is usually small.

Component 2: Boiler

The boiler adds heat at approximately constant pressure.

  • No shaft work

  • Heat input is the major energy input

  • Liquid becomes vapor and may become superheated

  • During boiling under the saturation dome, temperature remains constant while entropy increases

For a steady-flow boiler:

qin=h3−h2q_{\text{in}}=h_3-h_2qin​=h3​−h2​

Component 3: Turbine

The turbine expands high-pressure steam and produces work.

Typical assumptions:

  • Steady state

  • Adiabatic

  • Negligible kinetic and potential energy changes

For an ideal turbine:

s4s=s3s_{4s}=s_3s4s​=s3​

The ideal turbine work is:

wt,s=h3−h4sw_{t,s}=h_3-h_{4s}wt,s​=h3​−h4s​

For a real turbine:

wt,actual=h3−h4,actualw_{t,\text{actual}}=h_3-h_{4,\text{actual}}wt,actual​=h3​−h4,actual​

Component 4: Condenser

The condenser rejects heat at approximately constant pressure.

  • No shaft work

  • Heat leaves the cycle

  • Wet steam condenses into saturated liquid

The heat rejection is:

qout=h4−h1q_{\text{out}}=h_4-h_1qout​=h4​−h1​

Heat rejection cannot be reduced to zero because the second law requires a cold sink.


Rankine-Cycle Thermal Efficiency

The net work is:

wnet=wt−wpw_{\text{net}}=w_t-w_pwnet​=wt​−wp​

The boiler heat input is:

qin=h3−h2q_{\text{in}}=h_3-h_2qin​=h3​−h2​

Therefore:

ηRankine=wt−wpqin\boxed{ \eta_{\text{Rankine}} = \frac{w_t-w_p}{q_{\text{in}}} }ηRankine​=qin​wt​−wp​​​

Equivalently:

ηRankine=1−qoutqin\eta_{\text{Rankine}} = 1-\frac{q_{\text{out}}}{q_{\text{in}}}ηRankine​=1−qin​qout​​

Rankine-Cycle Problem Workflow

  1. Identify the component or quantity requested.

  2. Determine which two states bound that component.

  3. Identify the phase at each state.

  4. Use the appropriate property table.

  5. Find the required enthalpies or entropies.

  6. Apply the simplified SFEE.

  7. Include pump work unless the problem explicitly permits neglecting it.

  8. Check signs and magnitudes.

For example:

  • Boiler heat requires h2h_2h2​ and h3h_3h3​.

  • Turbine work requires h3h_3h3​ and h4h_4h4​.

  • Condenser heat rejection requires h4h_4h4​ and h1h_1h1​.

  • Pump work requires h1h_1h1​ and h2h_2h2​.

Unneeded data may be distractors; the required component usually depends only on the properties immediately before and after that component.

Effects of Irreversibility

A real turbine with less than 100%100\%100% isentropic efficiency produces less work than the ideal turbine.

Consequences include:

  • Higher actual turbine exit enthalpy

  • Lower turbine work

  • Lower net work

  • Lower overall thermal efficiency

  • Greater operating cost

Even small improvements in component efficiency can produce large economic benefits in large power plants.

Rankine-Cycle Diagram Summary

On a TTT-sss diagram:

  • Pump: approximately vertical upward

  • Boiler: heat addition toward the right

  • Ideal turbine: vertical downward

  • Real turbine: downward and slightly to the right

  • Condenser: heat rejection toward the left

The enclosed area represents net work, while the upper and lower areas represent heat input and heat rejection.

The central strategy for Rankine-cycle problems is to identify the component, select the two bounding enthalpies, and apply the appropriate simplified steady-flow energy equation.