Class Reminders and Homework
The Rankine Cycle: Steam Power Plant Analysis
π Introduction to the Rankine Cycle
The Rankine Cycle is the thermodynamic cycle used to model steam power plants. Unlike gas power cycles (Brayton, Otto, Diesel) that use air as the working fluid, the Rankine Cycle uses water/steam (HβO) as the working fluid.
Basic Schematic of the Simple Rankine Cycle
The cycle consists of four main components connected in a closed loop:
Pump: Moves liquid water from low pressure to high pressure (work input)
Boiler: Adds heat to convert liquid water into steam (heat input at constant pressure)
Turbine: Expands steam to produce work (work output)
Condenser: Removes heat to condense steam back into liquid (heat rejection at constant pressure)
The working fluid circulates continuously: liquid from pump β boiler β steam β turbine β condenser β liquid back to pump.
Key distinction: Unlike the Brayton Cycle where heat rejection is directly to the atmosphere, in the Rankine Cycle heat is rejected into a separate water supply (a heat sink), typically from a river, ocean, or cooling tower.
Constant Pressure Heat Transfer
Both heat addition (boiler) and heat rejection (condenser) occur at constant pressure. This is similar to the Brayton Cycle. Work processes (pump and turbine) are assumed isentropic (adiabatic and reversible) in the ideal cycle.
State Point on the T-s Diagram
State point 1: Always a saturated liquid at the condenser pressure. This is by design: the condenser condenses vapor to saturated liquid but does not subcool it further.
State point 2: Compressed liquid after isentropic compression in the pump (vertical line on T-s diagram, constant entropy).
State point 3: Steam entering the turbine. It may be superheated, saturated vapor, or a high-quality two-phase mixtureβdepends on heat added in the boiler.
State point 4: Steam exiting the turbine (isentropic expansion). May be two-phase, saturated, or superheated.
Important: The exact location of state points 3 and 4 varies depending on the problem data. The only fixed point is state 1 (saturated liquid). Analysis always uses appropriate steam tables (superheated, saturated, or compressed liquid).
π Equations for the Simple Ideal Rankine Cycle
All analyses assume no changes in kinetic or potential energy. Work processes are isentropic (no heat transfer during work), and heat transfer processes involve no work.
First Law for Each Component
For any steady-flow device, the first law reduces to:
Heat transfer equals enthalpy change (if no work)
Work equals enthalpy change (if no heat transfer)
Pump (Work Input)
For an ideal pump with a liquid (incompressible substance), an alternative expression applies:
Where v1β is the specific volume of the saturated liquid at state 1. This avoids using the compressed liquid tables (Table A7), which are sparse. The two expressions are equivalent in the ideal case.
Turbine (Work Output)
Boiler (Heat Input)
Condenser (Heat Rejection)
Thermal Efficiency
The efficiency of any heat engine cycle is:
All terms are based on enthalpy values from steam tables.
Power and Heat Transfer Rates
If the mass flow rate mΛ is known:
Using Steam Tables Instead of Ideal Gas Relations
Critical reminder: For the Rankine Cycle, do not use ideal gas equations (relative pressures, relative specific volumes, PV=nRT). Instead, use steam/water tables (Tables A4βA6 in typical textbooks). For an isentropic process, set s1β=s2β and use the known pressure to look up enthalpy from the tables.
Saturated mixtures: Use Table A4 (temperature table) or A5 (pressure table)
Superheated steam: Use Table A6
Compressed liquid: Rarely used; prefer wpumpβ=vΞP for ideal case
π’ Example Problem: Simple Ideal Rankine Cycle (Problem 10-12)
Given: Steam power plant operating on simple ideal Rankine Cycle
Pressure limits: Pmaxβ=3Β MPa, Pminβ=50Β kPa
Turbine inlet temperature: T3β=300βC
Mass flow rate: mΛ=35Β kg/s
Required: T-s diagram, thermal efficiency, net power output
Step-by-Step Solution
State 1: Saturated liquid at P1β=50Β kPa
From Table A5 (saturated water β pressure table):
h1β=hfβ=340.54Β kJ/kg
v1β=vfβ=0.001030Β m3/kg
State 2 (Ideal): Compressed liquid at P2β=3Β MPa
Using pump work equation:
Since wpumpβ=h2ββh1β:
State 3: Superheated steam at P3β=3Β MPa, T3β=300βC
Tsatβ@3Β MPaβ233.9βC, so T3β>Tsatβ β superheated. From Table A6:
h3β=2994.3Β kJ/kg
s3β=6.5412Β kJ/(kgβ K)
State 4 (Ideal): After isentropic expansion to P4β=50Β kPa, s4β=s3β
At 50 kPa, from Table A5:
sfβ=1.0912Β kJ/(kgβ K), sgβ=7.5931Β kJ/(kgβ K)
Since sfβ<s4β<sgβ, state 4 is a two-phase mixture.
Calculate quality x4β:
Enthalpy:
T-s Diagram
State 1: saturated liquid on lower saturation line at 50 kPa
State 2: vertical line up to 3 MPa (compressed liquid region)
State 3: superheated region at 3 MPa, 300Β°C
State 4: vertical line down to 50 kPa, two-phase region (quality 0.838)
Calculate Thermal Efficiency
Heat input:
Turbine work:
Net work:
Thermal efficiency:
Net Power Output
βοΈ Non-Ideal (Actual) Rankine Cycle
Real devices have irreversibilities (friction, heat loss, fluid friction). These are accounted for using isentropic efficiencies for the pump and turbine.
T-s Diagram for the Non-Ideal Cycle
2s: Ideal exit from pump (isentropic compression)
2a: Actual exit from pump (slightly to the right of 2s along the maximum pressure line)
4s: Ideal exit from turbine (isentropic expansion)
4a: Actual exit from turbine (to the right of 4s along the condenser pressure line)
Modified Equations
Pump Work (Actual)
Pump Isentropic Efficiency
Where h2sβ is found using the ideal pump work formula h2sββh1β=v1β(P2ββP1β).
Turbine Work (Actual)
Turbine Isentropic Efficiency
Heat Input (Actual)
The thermal efficiency equation remains:
π§ Example Problem: Non-Ideal Rankine Cycle (Same Problem with Efficiencies)
Same conditions as the ideal example, but now:
Pump isentropic efficiency: Ξ·pumpβ=80%
Turbine isentropic efficiency: Ξ·turbβ=90%
State 1 and state 3 data are identical to the ideal case. The ideal states (now labeled 2s and 4s) are exactly what we computed previously.
Actual Pump Exit (State 2a)
Ideal pump work: wpump,idealβ=3.04Β kJ/kg
Actual Turbine Exit (State 4a)
Ideal turbine work: wturb,idealβ=h3ββh4sβ=2994.3β2272.3=722.0Β kJ/kg
Check Phase of State 4a
At 50 kPa, hgβ=2645.2Β kJ/kg (approximate). Since h4aβ=2344.5<hgβ, the actual exit is still a two-phase mixture (quality can be computed if needed).
Heat Input (Actual)
Net Work (Actual)
Thermal Efficiency
Net Power
Comparison: The non-ideal efficiency (24.4%) is lower than the ideal (27.1%) due to losses. Note that the pump work is very small relative to turbine workβthe back work ratio (pump work/turbine work) is only about 0.6%.
π‘ Improving Rankine Cycle Efficiency
Two common modifications: regeneration and reheat.
Regeneration: Different from Brayton Cycle
In the Brayton Cycle, regeneration preheats combustion air using hot turbine exhaust, reducing fuel consumption. In the Rankine Cycle, the water leaving the pump is already hotter than the steam leaving the turbine. Therefore, conventional regeneration (transferring heat from exhaust to feedwater) is not thermodynamically feasible because heat cannot spontaneously flow from a cold to a hot stream. Regeneration in steam cycles is possible but uses open feedwater heaters β a different concept not covered in this lecture.
Reheat: The Practical Improvement
Reheat is the standard method to improve efficiency and address material constraints.
Why Reheat?
Higher thermal efficiency: The net work gained from the reheat process per unit heat input is greater than the average efficiency of the cycle, raising the overall efficiency.
Material temperature limits: Without reheat, very high turbine inlet temperatures are needed for high efficiency, but materials cannot withstand extreme temperatures. Reheat allows operation at moderate temperatures while still achieving high efficiency.
Schematic of Rankine Cycle with Reheat
Pump: Liquid from condenser (state 1) β high pressure (state 2)
Boiler: Heat added at high pressure β superheated steam (state 3)
High-pressure turbine (HP turbine): Expansion to an intermediate pressure (state 4)
Reheater: Heat added again at constant intermediate pressure β reheated steam (state 5). The reheater is physically located inside the furnace, adjacent to the boiler.
Low-pressure turbine (LP turbine): Expansion from state 5 to condenser pressure (state 6)
Condenser: Heat rejection to state 1
Key: There are two work outputs (HP and LP turbines) and two heat inputs (boiler and reheater). The pump work remains the same.
T-s Diagram for Ideal Reheat Cycle
1β2: Isentropic compression in pump (vertical, up to max pressure)
2β3: Constant pressure heat addition in boiler
3β4: Isentropic expansion in HP turbine (vertical, down to intermediate pressure)
4β5: Constant pressure heat addition in reheater at intermediate pressure
5β6: Isentropic expansion in LP turbine (vertical, down to condenser pressure)
6β1: Constant pressure heat rejection in condenser
Important Notes on Reheat
No requirement that pressure ratios be equal across the two turbines.
No requirement that turbine inlet temperatures be equal (T3β and T5β may differ). Common practice is to reheat to the same temperature as boiler exit, but not mandatory.
Multiple reheat stages are theoretically possible but rarely used in practice.
Multiple pumps are sometimes installed in parallel (e.g., three 50% capacity pumps) to allow maintenance without shutting down the plant.
Practical Considerations for Pumps and Turbines
Pumps are the biggest maintenance issue in power plants due to rotating equipment.
Having multiple fractional-capacity devices allows continuous operation during maintenance, justifying the extra cost through reduced downtime.
This concludes the foundational analysis of the Rankine Cycle for steam power plants. The next session will cover additional example problems and further discussion of reheat cycles.