The Rankine Cycle: Steam Power Plant Analysis

πŸš‚ Introduction to the Rankine Cycle

The Rankine Cycle is the thermodynamic cycle used to model steam power plants. Unlike gas power cycles (Brayton, Otto, Diesel) that use air as the working fluid, the Rankine Cycle uses water/steam (Hβ‚‚O) as the working fluid.

Basic Schematic of the Simple Rankine Cycle

The cycle consists of four main components connected in a closed loop:

  1. Pump: Moves liquid water from low pressure to high pressure (work input)

  2. Boiler: Adds heat to convert liquid water into steam (heat input at constant pressure)

  3. Turbine: Expands steam to produce work (work output)

  4. Condenser: Removes heat to condense steam back into liquid (heat rejection at constant pressure)

The working fluid circulates continuously: liquid from pump β†’ boiler β†’ steam β†’ turbine β†’ condenser β†’ liquid back to pump.

Key distinction: Unlike the Brayton Cycle where heat rejection is directly to the atmosphere, in the Rankine Cycle heat is rejected into a separate water supply (a heat sink), typically from a river, ocean, or cooling tower.

Constant Pressure Heat Transfer

Both heat addition (boiler) and heat rejection (condenser) occur at constant pressure. This is similar to the Brayton Cycle. Work processes (pump and turbine) are assumed isentropic (adiabatic and reversible) in the ideal cycle.

State Point on the T-s Diagram

  • State point 1: Always a saturated liquid at the condenser pressure. This is by design: the condenser condenses vapor to saturated liquid but does not subcool it further.

  • State point 2: Compressed liquid after isentropic compression in the pump (vertical line on T-s diagram, constant entropy).

  • State point 3: Steam entering the turbine. It may be superheated, saturated vapor, or a high-quality two-phase mixtureβ€”depends on heat added in the boiler.

  • State point 4: Steam exiting the turbine (isentropic expansion). May be two-phase, saturated, or superheated.

Important: The exact location of state points 3 and 4 varies depending on the problem data. The only fixed point is state 1 (saturated liquid). Analysis always uses appropriate steam tables (superheated, saturated, or compressed liquid).


πŸ“ Equations for the Simple Ideal Rankine Cycle

All analyses assume no changes in kinetic or potential energy. Work processes are isentropic (no heat transfer during work), and heat transfer processes involve no work.

First Law for Each Component

For any steady-flow device, the first law reduces to:

  • Heat transfer equals enthalpy change (if no work)

  • Work equals enthalpy change (if no heat transfer)

Pump (Work Input)

wpump=h2βˆ’h1w_{\text{pump}} = h_2 - h_1wpump​=h2β€‹βˆ’h1​

For an ideal pump with a liquid (incompressible substance), an alternative expression applies:

wpump=v1(P2βˆ’P1)w_{\text{pump}} = v_1 (P_2 - P_1)wpump​=v1​(P2β€‹βˆ’P1​)

Where v1v_1v1​ is the specific volume of the saturated liquid at state 1. This avoids using the compressed liquid tables (Table A7), which are sparse. The two expressions are equivalent in the ideal case.

Turbine (Work Output)

wturbine=h3βˆ’h4w_{\text{turbine}} = h_3 - h_4wturbine​=h3β€‹βˆ’h4​

Boiler (Heat Input)

qin=h3βˆ’h2q_{\text{in}} = h_3 - h_2qin​=h3β€‹βˆ’h2​

Condenser (Heat Rejection)

qout=h4βˆ’h1q_{\text{out}} = h_4 - h_1qout​=h4β€‹βˆ’h1​

Thermal Efficiency

The efficiency of any heat engine cycle is:

Ξ·th=wnetqin=wturbineβˆ’wpumpqin\eta_{\text{th}} = \frac{w_{\text{net}}}{q_{\text{in}}} = \frac{w_{\text{turbine}} - w_{\text{pump}}}{q_{\text{in}}}Ξ·th​=qin​wnet​​=qin​wturbineβ€‹βˆ’wpump​​

All terms are based on enthalpy values from steam tables.

Power and Heat Transfer Rates

If the mass flow rate mΛ™\dot{m}mΛ™ is known:

WΛ™=mΛ™wandQΛ™=mΛ™q\dot{W} = \dot{m} w \quad \text{and} \quad \dot{Q} = \dot{m} qWΛ™=mΛ™wandQ˙​=mΛ™q

Using Steam Tables Instead of Ideal Gas Relations

Critical reminder: For the Rankine Cycle, do not use ideal gas equations (relative pressures, relative specific volumes, PV=nRTPV = nRTPV=nRT). Instead, use steam/water tables (Tables A4–A6 in typical textbooks). For an isentropic process, set s1=s2s_1 = s_2s1​=s2​ and use the known pressure to look up enthalpy from the tables.

  • Saturated mixtures: Use Table A4 (temperature table) or A5 (pressure table)

  • Superheated steam: Use Table A6

  • Compressed liquid: Rarely used; prefer wpump=vΞ”Pw_{\text{pump}} = v\Delta Pwpump​=vΞ”P for ideal case


πŸ”’ Example Problem: Simple Ideal Rankine Cycle (Problem 10-12)

Given: Steam power plant operating on simple ideal Rankine Cycle

  • Pressure limits: Pmax=3Β MPaP_{\text{max}} = 3\ \text{MPa}Pmax​=3Β MPa, Pmin=50Β kPaP_{\text{min}} = 50\ \text{kPa}Pmin​=50Β kPa

  • Turbine inlet temperature: T3=300∘CT_3 = 300^\circ \text{C}T3​=300∘C

  • Mass flow rate: mΛ™=35Β kg/s\dot{m} = 35\ \text{kg/s}mΛ™=35Β kg/s

Required: T-s diagram, thermal efficiency, net power output

Step-by-Step Solution

State 1: Saturated liquid at P1=50Β kPaP_1 = 50\ \text{kPa}P1​=50Β kPa

From Table A5 (saturated water – pressure table):

  • h1=hf=340.54Β kJ/kgh_1 = h_f = 340.54\ \text{kJ/kg}h1​=hf​=340.54Β kJ/kg

  • v1=vf=0.001030Β m3/kgv_1 = v_f = 0.001030\ \text{m}^3/\text{kg}v1​=vf​=0.001030Β m3/kg

State 2 (Ideal): Compressed liquid at P2=3Β MPaP_2 = 3\ \text{MPa}P2​=3Β MPa

Using pump work equation:

wpump=v1(P2βˆ’P1)=0.001030Γ—(3000βˆ’50)=3.04Β kJ/kgw_{\text{pump}} = v_1(P_2 - P_1) = 0.001030 \times (3000 - 50) = 3.04\ \text{kJ/kg}wpump​=v1​(P2β€‹βˆ’P1​)=0.001030Γ—(3000βˆ’50)=3.04Β kJ/kg

Since wpump=h2βˆ’h1w_{\text{pump}} = h_2 - h_1wpump​=h2β€‹βˆ’h1​:

h2=h1+wpump=340.54+3.04=343.58Β kJ/kgh_2 = h_1 + w_{\text{pump}} = 340.54 + 3.04 = 343.58\ \text{kJ/kg}h2​=h1​+wpump​=340.54+3.04=343.58Β kJ/kg

State 3: Superheated steam at P3=3Β MPaP_3 = 3\ \text{MPa}P3​=3Β MPa, T3=300∘CT_3 = 300^\circ \text{C}T3​=300∘C

Tsat@3Β MPaβ‰ˆ233.9∘CT_{\text{sat}}@3\ \text{MPa} \approx 233.9^\circ \text{C}Tsat​@3Β MPaβ‰ˆ233.9∘C, so T3>TsatT_3 > T_{\text{sat}}T3​>Tsat​ β†’ superheated. From Table A6:

  • h3=2994.3Β kJ/kgh_3 = 2994.3\ \text{kJ/kg}h3​=2994.3Β kJ/kg

  • s3=6.5412Β kJ/(kgβ‹…K)s_3 = 6.5412\ \text{kJ/(kgΒ·K)}s3​=6.5412Β kJ/(kgβ‹…K)

State 4 (Ideal): After isentropic expansion to P4=50Β kPaP_4 = 50\ \text{kPa}P4​=50Β kPa, s4=s3s_4 = s_3s4​=s3​

At 50 kPa, from Table A5:

  • sf=1.0912Β kJ/(kgβ‹…K)s_f = 1.0912\ \text{kJ/(kgΒ·K)}sf​=1.0912Β kJ/(kgβ‹…K), sg=7.5931Β kJ/(kgβ‹…K)s_g = 7.5931\ \text{kJ/(kgΒ·K)}sg​=7.5931Β kJ/(kgβ‹…K)

Since sf<s4<sgs_f < s_4 < s_gsf​<s4​<sg​, state 4 is a two-phase mixture.

Calculate quality x4x_4x4​:

x4=s4βˆ’sfsgβˆ’sf=6.5412βˆ’1.09127.5931βˆ’1.0912=5.456.5019β‰ˆ0.8382x_4 = \frac{s_4 - s_f}{s_g - s_f} = \frac{6.5412 - 1.0912}{7.5931 - 1.0912} = \frac{5.45}{6.5019} \approx 0.8382x4​=sgβ€‹βˆ’sf​s4β€‹βˆ’sf​​=7.5931βˆ’1.09126.5412βˆ’1.0912​=6.50195.45β€‹β‰ˆ0.8382

Enthalpy:

h4=hf+x4hfg=340.54+0.8382Γ—2304.7=340.54+1931.76β‰ˆ2272.3Β kJ/kgh_4 = h_f + x_4 h_{fg} = 340.54 + 0.8382 \times 2304.7 = 340.54 + 1931.76 \approx 2272.3\ \text{kJ/kg}h4​=hf​+x4​hfg​=340.54+0.8382Γ—2304.7=340.54+1931.76β‰ˆ2272.3Β kJ/kg

T-s Diagram

State 1: saturated liquid on lower saturation line at 50 kPa
State 2: vertical line up to 3 MPa (compressed liquid region)
State 3: superheated region at 3 MPa, 300Β°C
State 4: vertical line down to 50 kPa, two-phase region (quality 0.838)

Calculate Thermal Efficiency

Heat input:

qin=h3βˆ’h2=2994.3βˆ’343.58=2650.72Β kJ/kgq_{\text{in}} = h_3 - h_2 = 2994.3 - 343.58 = 2650.72\ \text{kJ/kg}qin​=h3β€‹βˆ’h2​=2994.3βˆ’343.58=2650.72Β kJ/kg

Turbine work:

wturb=h3βˆ’h4=2994.3βˆ’2272.3=722.0Β kJ/kgw_{\text{turb}} = h_3 - h_4 = 2994.3 - 2272.3 = 722.0\ \text{kJ/kg}wturb​=h3β€‹βˆ’h4​=2994.3βˆ’2272.3=722.0Β kJ/kg

Net work:

wnet=wturbβˆ’wpump=722.0βˆ’3.04=718.96Β kJ/kgw_{\text{net}} = w_{\text{turb}} - w_{\text{pump}} = 722.0 - 3.04 = 718.96\ \text{kJ/kg}wnet​=wturbβ€‹βˆ’wpump​=722.0βˆ’3.04=718.96Β kJ/kg

Thermal efficiency:

Ξ·th=wnetqin=718.962650.72β‰ˆ0.271Β orΒ 27.1%\eta_{\text{th}} = \frac{w_{\text{net}}}{q_{\text{in}}} = \frac{718.96}{2650.72} \approx 0.271 \ \text{or} \ 27.1\%Ξ·th​=qin​wnet​​=2650.72718.96β€‹β‰ˆ0.271Β orΒ 27.1%

Net Power Output

WΛ™net=mΛ™wnet=35Γ—718.96=25,163.6Β kWβ‰ˆ25.2Β MW\dot{W}_{\text{net}} = \dot{m} w_{\text{net}} = 35 \times 718.96 = 25{,}163.6\ \text{kW} \approx 25.2\ \text{MW}WΛ™net​=mΛ™wnet​=35Γ—718.96=25,163.6Β kWβ‰ˆ25.2Β MW

βš™οΈ Non-Ideal (Actual) Rankine Cycle

Real devices have irreversibilities (friction, heat loss, fluid friction). These are accounted for using isentropic efficiencies for the pump and turbine.

T-s Diagram for the Non-Ideal Cycle

  • 2s: Ideal exit from pump (isentropic compression)

  • 2a: Actual exit from pump (slightly to the right of 2s along the maximum pressure line)

  • 4s: Ideal exit from turbine (isentropic expansion)

  • 4a: Actual exit from turbine (to the right of 4s along the condenser pressure line)

Modified Equations

Pump Work (Actual)

wpump,actual=h2aβˆ’h1w_{\text{pump,actual}} = h_{2a} - h_1wpump,actual​=h2aβ€‹βˆ’h1​

Pump Isentropic Efficiency

Ξ·pump=wpump,idealwpump,actual=h2sβˆ’h1h2aβˆ’h1\eta_{\text{pump}} = \frac{w_{\text{pump,ideal}}}{w_{\text{pump,actual}}} = \frac{h_{2s} - h_1}{h_{2a} - h_1}Ξ·pump​=wpump,actual​wpump,ideal​​=h2aβ€‹βˆ’h1​h2sβ€‹βˆ’h1​​

Where h2sh_{2s}h2s​ is found using the ideal pump work formula h2sβˆ’h1=v1(P2βˆ’P1)h_{2s} - h_1 = v_1(P_2 - P_1)h2sβ€‹βˆ’h1​=v1​(P2β€‹βˆ’P1​).

Turbine Work (Actual)

wturb,actual=h3βˆ’h4aw_{\text{turb,actual}} = h_3 - h_{4a}wturb,actual​=h3β€‹βˆ’h4a​

Turbine Isentropic Efficiency

Ξ·turb=wturb,actualwturb,ideal=h3βˆ’h4ah3βˆ’h4s\eta_{\text{turb}} = \frac{w_{\text{turb,actual}}}{w_{\text{turb,ideal}}} = \frac{h_3 - h_{4a}}{h_3 - h_{4s}}Ξ·turb​=wturb,ideal​wturb,actual​​=h3β€‹βˆ’h4s​h3β€‹βˆ’h4a​​

Heat Input (Actual)

qin=h3βˆ’h2aq_{\text{in}} = h_3 - h_{2a}qin​=h3β€‹βˆ’h2a​

The thermal efficiency equation remains:

Ξ·th=wturb,actualβˆ’wpump,actualqin\eta_{\text{th}} = \frac{w_{\text{turb,actual}} - w_{\text{pump,actual}}}{q_{\text{in}}}Ξ·th​=qin​wturb,actualβ€‹βˆ’wpump,actual​​

πŸ”§ Example Problem: Non-Ideal Rankine Cycle (Same Problem with Efficiencies)

Same conditions as the ideal example, but now:

  • Pump isentropic efficiency: Ξ·pump=80%\eta_{\text{pump}} = 80\%Ξ·pump​=80%

  • Turbine isentropic efficiency: Ξ·turb=90%\eta_{\text{turb}} = 90\%Ξ·turb​=90%

State 1 and state 3 data are identical to the ideal case. The ideal states (now labeled 2s and 4s) are exactly what we computed previously.

Actual Pump Exit (State 2a)

Ideal pump work: wpump,ideal=3.04Β kJ/kgw_{\text{pump,ideal}} = 3.04\ \text{kJ/kg}wpump,ideal​=3.04Β kJ/kg

Ξ·pump=3.04h2aβˆ’340.54=0.8\eta_{\text{pump}} = \frac{3.04}{h_{2a} - 340.54} = 0.8Ξ·pump​=h2aβ€‹βˆ’340.543.04​=0.8
h2aβˆ’340.54=3.040.8=3.80h_{2a} - 340.54 = \frac{3.04}{0.8} = 3.80h2aβ€‹βˆ’340.54=0.83.04​=3.80
h2a=340.54+3.80=344.34Β kJ/kgh_{2a} = 340.54 + 3.80 = 344.34\ \text{kJ/kg}h2a​=340.54+3.80=344.34Β kJ/kg

Actual Turbine Exit (State 4a)

Ideal turbine work: wturb,ideal=h3βˆ’h4s=2994.3βˆ’2272.3=722.0Β kJ/kgw_{\text{turb,ideal}} = h_3 - h_{4s} = 2994.3 - 2272.3 = 722.0\ \text{kJ/kg}wturb,ideal​=h3β€‹βˆ’h4s​=2994.3βˆ’2272.3=722.0Β kJ/kg

Ξ·turb=2994.3βˆ’h4a722.0=0.9\eta_{\text{turb}} = \frac{2994.3 - h_{4a}}{722.0} = 0.9Ξ·turb​=722.02994.3βˆ’h4a​​=0.9
2994.3βˆ’h4a=722.0Γ—0.9=649.82994.3 - h_{4a} = 722.0 \times 0.9 = 649.82994.3βˆ’h4a​=722.0Γ—0.9=649.8
h4a=2994.3βˆ’649.8=2344.5Β kJ/kgh_{4a} = 2994.3 - 649.8 = 2344.5\ \text{kJ/kg}h4a​=2994.3βˆ’649.8=2344.5Β kJ/kg

Check Phase of State 4a

At 50 kPa, hg=2645.2Β kJ/kgh_g = 2645.2\ \text{kJ/kg}hg​=2645.2Β kJ/kg (approximate). Since h4a=2344.5<hgh_{4a} = 2344.5 < h_gh4a​=2344.5<hg​, the actual exit is still a two-phase mixture (quality can be computed if needed).

Heat Input (Actual)

qin=h3βˆ’h2a=2994.3βˆ’344.34=2649.96Β kJ/kgq_{\text{in}} = h_3 - h_{2a} = 2994.3 - 344.34 = 2649.96\ \text{kJ/kg}qin​=h3β€‹βˆ’h2a​=2994.3βˆ’344.34=2649.96Β kJ/kg

Net Work (Actual)

wturb,actual=649.8Β kJ/kgw_{\text{turb,actual}} = 649.8\ \text{kJ/kg}wturb,actual​=649.8Β kJ/kg
wpump,actual=3.80Β kJ/kgw_{\text{pump,actual}} = 3.80\ \text{kJ/kg}wpump,actual​=3.80Β kJ/kg
wnet=649.8βˆ’3.80=646.0Β kJ/kgw_{\text{net}} = 649.8 - 3.80 = 646.0\ \text{kJ/kg}wnet​=649.8βˆ’3.80=646.0Β kJ/kg

Thermal Efficiency

Ξ·th=646.02649.96β‰ˆ0.244Β orΒ 24.4%\eta_{\text{th}} = \frac{646.0}{2649.96} \approx 0.244 \ \text{or} \ 24.4\%Ξ·th​=2649.96646.0β€‹β‰ˆ0.244Β orΒ 24.4%

Net Power

WΛ™net=35Γ—646.0=22,610Β kWβ‰ˆ22.6Β MW\dot{W}_{\text{net}} = 35 \times 646.0 = 22{,}610\ \text{kW} \approx 22.6\ \text{MW}WΛ™net​=35Γ—646.0=22,610Β kWβ‰ˆ22.6Β MW

Comparison: The non-ideal efficiency (24.4%) is lower than the ideal (27.1%) due to losses. Note that the pump work is very small relative to turbine workβ€”the back work ratio (pump work/turbine work) is only about 0.6%.


πŸ’‘ Improving Rankine Cycle Efficiency

Two common modifications: regeneration and reheat.

Regeneration: Different from Brayton Cycle

In the Brayton Cycle, regeneration preheats combustion air using hot turbine exhaust, reducing fuel consumption. In the Rankine Cycle, the water leaving the pump is already hotter than the steam leaving the turbine. Therefore, conventional regeneration (transferring heat from exhaust to feedwater) is not thermodynamically feasible because heat cannot spontaneously flow from a cold to a hot stream. Regeneration in steam cycles is possible but uses open feedwater heaters β€” a different concept not covered in this lecture.

Reheat: The Practical Improvement

Reheat is the standard method to improve efficiency and address material constraints.

Why Reheat?

  1. Higher thermal efficiency: The net work gained from the reheat process per unit heat input is greater than the average efficiency of the cycle, raising the overall efficiency.

  2. Material temperature limits: Without reheat, very high turbine inlet temperatures are needed for high efficiency, but materials cannot withstand extreme temperatures. Reheat allows operation at moderate temperatures while still achieving high efficiency.

Schematic of Rankine Cycle with Reheat

  1. Pump: Liquid from condenser (state 1) β†’ high pressure (state 2)

  2. Boiler: Heat added at high pressure β†’ superheated steam (state 3)

  3. High-pressure turbine (HP turbine): Expansion to an intermediate pressure (state 4)

  4. Reheater: Heat added again at constant intermediate pressure β†’ reheated steam (state 5). The reheater is physically located inside the furnace, adjacent to the boiler.

  5. Low-pressure turbine (LP turbine): Expansion from state 5 to condenser pressure (state 6)

  6. Condenser: Heat rejection to state 1

Key: There are two work outputs (HP and LP turbines) and two heat inputs (boiler and reheater). The pump work remains the same.

T-s Diagram for Ideal Reheat Cycle

  • 1β†’2: Isentropic compression in pump (vertical, up to max pressure)

  • 2β†’3: Constant pressure heat addition in boiler

  • 3β†’4: Isentropic expansion in HP turbine (vertical, down to intermediate pressure)

  • 4β†’5: Constant pressure heat addition in reheater at intermediate pressure

  • 5β†’6: Isentropic expansion in LP turbine (vertical, down to condenser pressure)

  • 6β†’1: Constant pressure heat rejection in condenser

Important Notes on Reheat

  • No requirement that pressure ratios be equal across the two turbines.

  • No requirement that turbine inlet temperatures be equal (T3T_3T3​ and T5T_5T5​ may differ). Common practice is to reheat to the same temperature as boiler exit, but not mandatory.

  • Multiple reheat stages are theoretically possible but rarely used in practice.

  • Multiple pumps are sometimes installed in parallel (e.g., three 50% capacity pumps) to allow maintenance without shutting down the plant.

Practical Considerations for Pumps and Turbines

  • Pumps are the biggest maintenance issue in power plants due to rotating equipment.

  • Having multiple fractional-capacity devices allows continuous operation during maintenance, justifying the extra cost through reduced downtime.


This concludes the foundational analysis of the Rankine Cycle for steam power plants. The next session will cover additional example problems and further discussion of reheat cycles.