Class Reminders and Homework
- 30Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
What type of power plant does the Rankine Cycle model?
30 questions
- 1
What type of power plant does the Rankine Cycle model?
Model answer
The Rankine Cycle models a steam power plant.
Explanation
This is the fundamental application: the Rankine Cycle is used to analyze and design steam power plants.
- 2
List the four main components of the simple Rankine Cycle in order.
Model answer
Pump, boiler, turbine, condenser.
Explanation
The pump pressurizes liquid, the boiler adds heat to vaporize it, the turbine extracts work, and the condenser rejects heat to condense the vapor back to liquid.
- 3
How does heat rejection in the Rankine Cycle differ from that in the Brayton Cycle?
Model answer
In the Rankine Cycle, heat is rejected into a separate water supply (e.g., cooling tower, river) rather than directly into the atmosphere.
Explanation
Unlike the Brayton cycle, the condenser uses an external cooling medium to absorb the waste heat.
- 4
What does the term 'simple' Mean when applied to the Rankine Cycle?
Model answer
It refers to the basic cycle with a single pump, boiler, turbine, and condenser, without reheat or regeneration.
Explanation
The simple Rankine Cycle is the most straightforward configuration.
- 5
In the ideal Rankine Cycle, what is assumed about the work processes in the pump and turbine?
Model answer
They are assumed to be isentropic (adiabatic and reversible).
Explanation
Isentropic means no heat transfer and no irreversibilities; the process is reversible adiabatic.
- 6
Write the equation for pump work per unit mass in the ideal Rankine Cycle, using specific volume and pressure difference.
Model answer
Wpump,in=v1(P2−P1)
Explanation
For an ideal pump handling an incompressible liquid, the work is the product of specific volume and pressure rise.
- 7
Write the equation for turbine work per unit mass in the ideal Rankine Cycle.
Model answer
Wturb,out=h3−h4
Explanation
The turbine work is the enthalpy difference between inlet and outlet under isentropic expansion.
- 8
Write the equation for heat input per unit mass in the boiler of an ideal Rankine Cycle.
Model answer
Qin=h3−h2
Explanation
Heat added at constant pressure equals the enthalpy increase from the pump outlet to the turbine inlet.
- 9
Write the equation for heat rejection per unit mass in the condenser of an ideal Rankine Cycle.
Model answer
Qout=h4−h1
Explanation
Heat rejected at constant pressure is the enthalpy difference from turbine outlet to condenser outlet.
- 10
How is thermal efficiency defined for the Rankine Cycle?
Model answer
ηth=QinWnet=QinWturb,out−Wpump,in
Explanation
The efficiency is the ratio of net work output to total heat input.
- 11
How do you calculate the power output of a Rankine Cycle plant given mass flow rate and specific work?
Model answer
W˙net=m˙×Wnet (power = mass flow rate times net work per unit mass).
Explanation
The power is the product of mass flow rate and the net work per kilogram of working fluid.
- 12
What is the standard state of the working fluid at point 1 (condenser outlet) in any Rankine Cycle?
Model answer
It is a saturated liquid.
Explanation
The condenser is designed to condense vapor to liquid but not subcool it, so the exit is saturated liquid.
- 13
In the ideal Rankine Cycle on a T-s diagram, what shape are the pump and turbine processes?
Model answer
They are vertical lines (constant entropy / isentropic).
Explanation
Isentropic processes on a T-s diagram are vertical lines because entropy does not change.
- 14
Define the isentropic efficiency of a pump.
Model answer
ηpump=Wpump,actualWpump,ideal=h2A−h1v1(P2−P1)
Explanation
It compares the ideal work (using vΔP) to the actual work (using actual enthalpy change).
- 15
Define the isentropic efficiency of a turbine.
Model answer
ηturb=Wturb,idealWturb,actual=h3−h4Sh3−h4A
Explanation
It is the ratio of actual work output to the work output if the expansion were isentropic.
- 16
In a non-ideal Rankine Cycle, how do you find the actual enthalpy at the pump exit (h2A)?
Model answer
Using the pump efficiency: h2A=h1+ηpumpv1(P2−P1)
Explanation
The actual pump work is the ideal work divided by the efficiency, so h2A=h1+Wpump,actual.
- 17
In a non-ideal Rankine Cycle, how do you find the actual enthalpy at the turbine exit (h4A)?
Model answer
Using the turbine efficiency: h4A=h3−ηturb(h3−h4S)
Explanation
The actual work is the ideal work times the efficiency, so h4A=h3−Wturb,actual.
- 18
In the example problem 10-12 (ideal), what were the given pressure limits?
Model answer
3 MPa (maximum) and 50 kPa (minimum).
Explanation
These are the high and low pressures of the cycle.
- 19
In the example problem 10-12 (ideal), what was the turbine inlet temperature and mass flow rate?
Model answer
Turbine inlet temperature = 300°C; mass flow rate = 35 kg/s.
Explanation
These are key inputs to determine state 3 and the overall power.
- 20
What were the thermal efficiency and net power output for the ideal example (10-12)?
Model answer
Thermal efficiency = 27.1%; net power output = 25.2 MW.
Explanation
These results come from solving the ideal cycle with the given data.
- 21
When pump and turbine inefficiencies were introduced (80% pump, 90% turbine) in the same example, how did the efficiency and power change?
Model answer
Efficiency dropped to 24.4% and power to 22.6 MW.
Explanation
Inefficiencies reduce both the net work and the cycle efficiency.
- 22
Why is regeneration not typically used in Rankine Cycles the way it is in Brayton Cycles?
Model answer
Because the pump outlet temperature is higher than the turbine exhaust temperature, so heat cannot be transferred from the exhaust to the feedwater.
Explanation
Regeneration requires a hot exhaust to preheat the incoming fluid, but here the exhaust is cooler than the compressed liquid.
- 23
What is the back work ratio in a typical Rankine Cycle, and why is reducing pump work not cost-effective?
Model answer
The back work ratio (pump work to turbine work) is very small (typical less than 1%), so reducing pump work yields negligible efficiency gains and is not worth the cost.
Explanation
Because pump work is a tiny fraction of turbine work, even large pump improvements have little effect on overall efficiency.
- 24
Why do power plants often use multiple pumps operating in parallel?
Model answer
To allow maintenance on one pump while the others continue operating, avoiding plant shutdowns.
Explanation
Rotating equipment like pumps require frequent maintenance; having three 50% capacity pumps allows one to be serviced while the other two run at full load.
- 25
What are two reasons for using reheat in a Rankine Cycle?
Model answer
To improve thermal efficiency and to avoid excessively high steam temperatures that cause material problems.
Explanation
Reheat increases the average temperature of heat addition and reduces moisture in later turbine stages.
- 26
Sketch the ideal reheat Rankine Cycle on a T-s diagram and label the state points (1 to 6). Describe the processes.
Model answer
1-2: isentropic compression; 2-3: constant pressure heat addition in boiler; 3-4: isentropic expansion in HP turbine; 4-5: constant pressure reheat; 5-6: isentropic expansion in LP turbine; 6-1: constant pressure heat rejection in condenser.
Explanation
The reheat cycle adds an extra heat input at intermediate pressure and expansion in two stages.
- 27
In a reheat Rankine Cycle, how many heat inputs and work outputs are there?
Model answer
Two heat inputs (boiler and reheater) and two work outputs (HP turbine and LP turbine).
Explanation
The boiler and reheater both add heat; the two turbines both produce work.
- 28
In a reheat Rankine Cycle, must the pressure ratios across the two turbines be equal?
Model answer
No, they can be different.
Explanation
There is no requirement for equal pressure ratios; the intermediate pressure is chosen based on design.
- 29
In a reheat Rankine Cycle, must the temperatures at the inlets of the two turbines be the same?
Model answer
No, they can be different.
Explanation
The temperature after reheat can be different from the initial turbine inlet temperature; common practice is to use similar temperatures, but it is not required.
- 30
What is the typical range of pump work compared to turbine work in a Rankine Cycle?
Model answer
Pump work is usually less than 1% of turbine work.
Explanation
This very low back work ratio is a key difference from gas cycles where compressor work can be 50% of turbine work.

Ask anything