Boost Converter Control
- 72Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
72 questions
- 1In the boost converter example, the two state variables are the inductor current and the voltage across the_____.
Hint
One state describes energy stored magnetically, and the other describes energy stored electrically.
Answer
capacitor
- 2The switching function that is controlled in the converter is q of t; its local average is called the_____.
Hint
It describes the fraction of a switching cycle for which a switch is on.
Answer
duty ratio
- 3In voltage regulation, the output voltage is compared with a reference, and the resulting error is processed by the_____.
Hint
This controller processes the voltage error and generates a command for the converter.
Answer
compensator
- 4A converter transfer function H of S can describe how variations in duty ratio produce variations in_____.
Hint
This is the regulated electrical quantity in the voltage-control loop.
Answer
output voltage
- 5Linearization is useful because the small-signal dynamics of many converters are_____.
Hint
Their behavior does not remain the same across all operating conditions.
Answer
nonlinear
- 6The converter’s second-order oscillations arise from energy exchange between the inductor and the_____.
Hint
This component stores energy in an electric field and helps form the resonant pair with the inductor.
Answer
capacitor
- 7In the converter’s second-order response, oscillations are damped by the load_____.
Hint
This load element dissipates energy and reduces the oscillations.
Answer
resistor
- 8Because switching modulation mediates the inductor-capacitor oscillations, the converter’s dynamics can vary with its operating point, including its input and output_____.
Hint
These operating-point quantities determine the steady-state modulation.
Answer
voltages
- 9The boost-converter transfer function includes a zero in the_____half-plane.
Hint
This zero is associated with the converter’s energy-processing behavior and is not removed by changing the controller.
Answer
right
- 10The converter’s pole locations are determined by how the inductor, capacitor, and load resistance interact as a_____-order system.
Hint
The number of independent energy-storage elements determines this system order.
Answer
second
- 11When the load resistance provides little damping, the converter poles are described as_____damped.
Hint
This describes poles associated with persistent oscillations.
Answer
lightly
- 12Adding a resistor and capacitor to the plant can improve damping; near the oscillation corner frequency, the added capacitor acts approximately as a_____circuit.
Hint
At the relevant frequency, the capacitor provides a low-impedance path.
Answer
short
- 13A drawback of adding damping components to the plant is the extra_____required.
Hint
The added components have to be purchased and physically included in the converter.
Answer
hardware
- 14A controller can sometimes be made easier to design by choosing the inductor and capacitor values to set the converter’s_____.
Hint
These describe how the converter responds over time.
Answer
dynamics
- 15Full-state feedback aims to improve dynamics by feeding back_____of the system’s state variables.
Hint
The name of the strategy indicates how much of the state is fed back.
Answer
all
- 16The general idea behind current mode control originated in the_____.
Hint
This decade preceded the late-1970s development of the specific version discussed.
Answer
1960s
- 17The particular current mode control version described became established in the late_____.
Hint
It followed the decade in which the general concept originated.
Answer
1970s
- 18In current mode control, the inner loop feeds back the inductor_____.
Hint
It is the quantity sensed and compared with a current command.
Answer
current
- 19In the two-loop current mode scheme, the outer loop feeds back the output_____.
Hint
This is the regulated quantity compared with its reference.
Answer
voltage
- 20The output-voltage compensator generates the_____used by the inner current loop.
Hint
It is the command that the inductor current is controlled to follow.
Answer
current reference
- 21The fast inner loop and slow outer loop arrangement is also called_____control.
Hint
This term describes the nested-loop organization used in the scheme.
Answer
minor loop
- 22The outer loop should not change its command rapidly within a switching cycle because average models are intended for time scales slow compared with the_____frequency.
Hint
The model averages behavior associated with the repeated operation of the switches.
Answer
switching
- 23The inner current loop in peak current mode control operates on a_____-by-cycle basis.
Hint
The switching decision is made anew during each switching period.
Answer
cycle
- 24In the described switching sequence, the switch is turned on at the beginning of each_____.
Hint
The sequence repeats with the switching period.
Answer
cycle
- 25In peak current mode control, the switch turns off when the sensed inductor current reaches the commanded peak-current threshold, rather than after a directly specified_____.
Hint
This is the conventional switching command that is determined implicitly in this method.
Answer
duty ratio
- 26The current reference is approximately constant within a switching cycle but moves up and down as commanded by the_____loop.
Hint
This loop regulates output voltage and supplies the current command.
Answer
outer
- 27In peak current mode control, the sensed inductor current is compared with a current command modified by a_____ramp.
Hint
This ramp is added to address a switching-cycle ripple instability.
Answer
compensating
- 28For a boost converter, the rising inductor-current slope M1 is the input voltage divided by the_____.
Hint
The rising slope depends on the input voltage and the energy-storage component’s value.
Answer
inductance
- 29For a boost converter, the magnitude of the falling inductor-current slope M2 is the output voltage minus the input voltage, divided by the_____.
Hint
The falling slope is determined by the difference between output and input voltage and the inductor value.
Answer
inductance
- 30The same rising-and-falling current waveform analysis can be applied to other converter types by using their appropriate current_____.
Hint
Different converter topologies have different rising and falling rates.
Answer
slopes
- 31Compared with duty-ratio control, peak current mode control gives direct control over the_____current.
Hint
This is the current sensed by the inner loop and limited each cycle.
Answer
inductor
- 32A useful benefit of peak current control is automatic_____limiting.
Hint
The switch turns off when the sensed current reaches its commanded threshold.
Answer
current
- 33In a boost converter, peak current control can limit current only while the output voltage is greater than the_____voltage.
Hint
A short circuit can defeat the described current-control mechanism if this voltage condition is not met.
Answer
input
- 34If the output voltage falls below its reference, the outer-loop error grows and the compensator increases the_____command.
Hint
The larger command makes the inductor carry more current to supply the output.
Answer
peak current
- 35The inductor current multiplied by the input voltage indicates the power drawn from the_____.
Hint
This is the source from which the converter draws energy.
Answer
input
- 36When current is sensed only while the switch is on, a small resistor can be placed in the switch-current path to measure the_____.
Hint
The measured switch quantity provides the comparison signal for the current controller.
Answer
current
- 37Instead of a separate sensing resistor, the switch’s own_____can sometimes be used to sense current.
Hint
A voltage associated with this property can indicate the current through the switch.
Answer
resistance
- 38Directly deriving a current-mode model by averaging the switching behavior is described as mathematically_____.
Hint
The approach encounters a substantial mathematical obstacle.
Answer
difficult
- 39A simpler route to a current-mode model is to relate the peak current to the_____and substitute that relation into an existing averaged model.
Hint
The existing model already uses this quantity as its control variable.
Answer
duty ratio
- 40The waveform-based estimate of local average inductor current is made by averaging the current over a switching-period_____.
Hint
It is a time interval over which the waveform is considered.
Answer
window
- 41The relation between local average inductor current, peak current, duty ratio, current slopes, and the compensating ramp is obtained using a_____approximation.
Hint
The method estimates averages using the areas of triangular regions in the waveform.
Answer
geometric
- 42When calculating the local average from the current waveform, the areas of the rising-side and falling-side triangles are_____from the peak-related value.
Hint
These triangular areas lie outside the portion represented by the average current.
Answer
subtracted
- 43The waveform average over the chosen window is an approximation to the local average current; it is not exactly equal at every point in_____.
Hint
The approximation is tied to the waveform’s value at a particular instant.
Answer
time
- 44For a different converter topology, the same modeling procedure can be used after substituting that converter’s appropriate rising and falling current_____.
Hint
These determine the shape of the current waveform used in the geometric approximation.
Answer
slopes
- 45Replacing duty-ratio variation with peak-current variation produces a new transfer function from peak-current variation to output-voltage_____.
Hint
The transfer function describes how the regulated output responds to the new control input.
Answer
variation
- 46The peak-current model retains the converter’s right-half-plane zero because that feature comes from how the converter processes_____.
Hint
The zero reflects the physical operation of the plant rather than a mathematical modeling artifact.
Answer
energy
- 47With current mode control, the two lightly damped poles tend to become a dominant pole and a second pole at a much_____frequency.
Hint
The second pole is separated from the dominant, lower-frequency pole.
Answer
higher
- 48The dominant current-mode pole is largely associated with inductor current charging and discharging the output_____.
Hint
This component stores the output energy and its voltage changes as current flows into or out of it.
Answer
capacitor
- 49Without a compensating ramp, peak current control can fail to repeat the same waveform every switching_____.
Hint
The desired steady state repeats after each interval of the switching clock.
Answer
period
- 50A current waveform that repeats every other switching cycle is an example of a_____oscillation.
Hint
Its repetition frequency is below the switching frequency.
Answer
subharmonic
- 51The broader name for failure of the current ripple to settle into periodic steady-state behavior is_____instability.
Hint
The term refers to the varying current waveform from cycle to cycle.
Answer
ripple
- 52Without sufficient slope compensation, the cycle-to-cycle behavior can sometimes become_____rather than merely periodic.
Hint
This describes behavior that does not settle into a regular repeating pattern.
Answer
chaotic
- 53A ripple instability can produce larger current ripple and more_____control behavior.
Hint
The switching duty ratio varies unpredictably from cycle to cycle.
Answer
jittery
- 54The ripple instability may introduce lower-frequency content into the converter’s_____.
Hint
This is the signal that can be affected by the enlarged, irregular ripple.
Answer
output
- 55Adding a sufficiently large compensating ramp makes the current ripple decay toward a fixed repeating_____.
Hint
This is the desired stable pattern that repeats each switching cycle.
Answer
waveform
- 56The compensating ramp is practical to implement partly because converters already use a ramp generator to establish the switching_____.
Hint
The ramp’s threshold crossing can set the timing of the oscillator.
Answer
clock frequency
- 57In the cycle-to-cycle error analysis, stability requires the magnitude of the error multiplier to be_____than one.
Hint
For the error to decay from one cycle to the next, its multiplying factor must have magnitude below this threshold.
Answer
less
- 58In the error multiplier, increasing the compensating-ramp slope tends to reduce the multiplier’s magnitude by increasing its denominator and reducing its_____.
Hint
This is the other part of a fraction besides its denominator.
Answer
numerator
- 59If the compensating-ramp slope equals the falling-current slope M2, the cycle-to-cycle error can disappear in_____cycle.
Hint
The error multiplier becomes zero in this case.
Answer
one
- 60For the boost converter with no slope compensation, ripple instability becomes a concern as the duty ratio approaches or exceeds_____percent.
Hint
This is the halfway point of a switching period.
Answer
50
- 61A larger compensating ramp is not always better because it changes the converter’s linearized_____.
Hint
This is why the ramp value must be considered when designing the controller.
Answer
dynamics
- 62If the compensating ramp is made too large, the converter can again develop_____poles.
Hint
These poles would make oscillatory behavior difficult to control.
Answer
undamped
- 63A practical design chooses a compensating ramp large enough to stabilize the ripple but avoids making it much_____than necessary.
Hint
Excessive ramp slope can worsen the pole locations.
Answer
larger
- 64The compensating-ramp slope is commonly set with a_____rather than continuously adjusted for every operating condition.
Hint
It is a simple circuit component often used to set a control parameter.
Answer
resistor
- 65Peak current mode control is widely used in PWM DC-to-DC converters and is found in many control_____.
Hint
These integrated components implement converter control functions.
Answer
chips
- 66Peak current mode control is the most common version of the broader current mode control idea, while another version is_____control.
Hint
This alternative focuses on the low point of the current waveform rather than its peak.
Answer
valley
- 67Current mode control makes the converter easier to compensate because its dominant pole is more clearly separated from the higher-frequency_____.
Hint
This is the other pole in the second-order model.
Answer
pole
- 68Even with current mode control, the designer must account for the right-half-plane zero when designing the_____loop.
Hint
This loop regulates output voltage using the current reference.
Answer
outer
- 69The inner current loop does not make the converter truly first order; it remains a_____-order system.
Hint
The converter still has two state variables and two poles.
Answer
second
- 70At low boost ratios, the ripple instability may disappear even without a compensating ramp, whereas higher boost ratios can produce more_____behavior.
Hint
The current ripple may vary from cycle to cycle instead of settling into a regular pattern.
Answer
irregular
- 71When the compensating ramp is enabled in the demonstration, the converter returns to stable periodic steady-state_____.
Hint
This is the desired repeating behavior from cycle to cycle.
Answer
operation
- 72To analyze a current-mode converter, the averaged and linearized converter modeling approach is extended with an additional_____relating peak current and duty ratio.
Hint
This is the extra modeling operation needed to form the current-mode model.
Answer
step

Ask anything