1. Home
  2. Explore
  3. Engineering
  4. Boost Converter Control

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

Boost Converter Control

  • 72Unfamiliar
  • 0Learning
  • 0Familiar
  • 0Mastered
Topic: Converter Dynamics
In the boost converter example, the two state variables are the inductor current and the voltage across the
.

72 questions

  1. 1
    In the boost converter example, the two state variables are the inductor current and the voltage across the
    _____
    .
    Hint

    One state describes energy stored magnetically, and the other describes energy stored electrically.

    Answer

    capacitor

  2. 2
    The switching function that is controlled in the converter is q of t; its local average is called the
    _____
    .
    Hint

    It describes the fraction of a switching cycle for which a switch is on.

    Answer

    duty ratio

  3. 3
    In voltage regulation, the output voltage is compared with a reference, and the resulting error is processed by the
    _____
    .
    Hint

    This controller processes the voltage error and generates a command for the converter.

    Answer

    compensator

  4. 4
    A converter transfer function H of S can describe how variations in duty ratio produce variations in
    _____
    .
    Hint

    This is the regulated electrical quantity in the voltage-control loop.

    Answer

    output voltage

  5. 5
    Linearization is useful because the small-signal dynamics of many converters are
    _____
    .
    Hint

    Their behavior does not remain the same across all operating conditions.

    Answer

    nonlinear

  6. 6
    The converter’s second-order oscillations arise from energy exchange between the inductor and the
    _____
    .
    Hint

    This component stores energy in an electric field and helps form the resonant pair with the inductor.

    Answer

    capacitor

  7. 7
    In the converter’s second-order response, oscillations are damped by the load
    _____
    .
    Hint

    This load element dissipates energy and reduces the oscillations.

    Answer

    resistor

  8. 8
    Because switching modulation mediates the inductor-capacitor oscillations, the converter’s dynamics can vary with its operating point, including its input and output
    _____
    .
    Hint

    These operating-point quantities determine the steady-state modulation.

    Answer

    voltages

  9. 9
    The boost-converter transfer function includes a zero in the
    _____
    half-plane.
    Hint

    This zero is associated with the converter’s energy-processing behavior and is not removed by changing the controller.

    Answer

    right

  10. 10
    The converter’s pole locations are determined by how the inductor, capacitor, and load resistance interact as a
    _____
    -order system.
    Hint

    The number of independent energy-storage elements determines this system order.

    Answer

    second

  11. 11
    When the load resistance provides little damping, the converter poles are described as
    _____
    damped.
    Hint

    This describes poles associated with persistent oscillations.

    Answer

    lightly

  12. 12
    Adding a resistor and capacitor to the plant can improve damping; near the oscillation corner frequency, the added capacitor acts approximately as a
    _____
    circuit.
    Hint

    At the relevant frequency, the capacitor provides a low-impedance path.

    Answer

    short

  13. 13
    A drawback of adding damping components to the plant is the extra
    _____
    required.
    Hint

    The added components have to be purchased and physically included in the converter.

    Answer

    hardware

  14. 14
    A controller can sometimes be made easier to design by choosing the inductor and capacitor values to set the converter’s
    _____
    .
    Hint

    These describe how the converter responds over time.

    Answer

    dynamics

  15. 15
    Full-state feedback aims to improve dynamics by feeding back
    _____
    of the system’s state variables.
    Hint

    The name of the strategy indicates how much of the state is fed back.

    Answer

    all

  16. 16
    The general idea behind current mode control originated in the
    _____
    .
    Hint

    This decade preceded the late-1970s development of the specific version discussed.

    Answer

    1960s

  17. 17
    The particular current mode control version described became established in the late
    _____
    .
    Hint

    It followed the decade in which the general concept originated.

    Answer

    1970s

  18. 18
    In current mode control, the inner loop feeds back the inductor
    _____
    .
    Hint

    It is the quantity sensed and compared with a current command.

    Answer

    current

  19. 19
    In the two-loop current mode scheme, the outer loop feeds back the output
    _____
    .
    Hint

    This is the regulated quantity compared with its reference.

    Answer

    voltage

  20. 20
    The output-voltage compensator generates the
    _____
    used by the inner current loop.
    Hint

    It is the command that the inductor current is controlled to follow.

    Answer

    current reference

  21. 21
    The fast inner loop and slow outer loop arrangement is also called
    _____
    control.
    Hint

    This term describes the nested-loop organization used in the scheme.

    Answer

    minor loop

  22. 22
    The outer loop should not change its command rapidly within a switching cycle because average models are intended for time scales slow compared with the
    _____
    frequency.
    Hint

    The model averages behavior associated with the repeated operation of the switches.

    Answer

    switching

  23. 23
    The inner current loop in peak current mode control operates on a
    _____
    -by-cycle basis.
    Hint

    The switching decision is made anew during each switching period.

    Answer

    cycle

  24. 24
    In the described switching sequence, the switch is turned on at the beginning of each
    _____
    .
    Hint

    The sequence repeats with the switching period.

    Answer

    cycle

  25. 25
    In peak current mode control, the switch turns off when the sensed inductor current reaches the commanded peak-current threshold, rather than after a directly specified
    _____
    .
    Hint

    This is the conventional switching command that is determined implicitly in this method.

    Answer

    duty ratio

  26. 26
    The current reference is approximately constant within a switching cycle but moves up and down as commanded by the
    _____
    loop.
    Hint

    This loop regulates output voltage and supplies the current command.

    Answer

    outer

  27. 27
    In peak current mode control, the sensed inductor current is compared with a current command modified by a
    _____
    ramp.
    Hint

    This ramp is added to address a switching-cycle ripple instability.

    Answer

    compensating

  28. 28
    For a boost converter, the rising inductor-current slope M1 is the input voltage divided by the
    _____
    .
    Hint

    The rising slope depends on the input voltage and the energy-storage component’s value.

    Answer

    inductance

  29. 29
    For a boost converter, the magnitude of the falling inductor-current slope M2 is the output voltage minus the input voltage, divided by the
    _____
    .
    Hint

    The falling slope is determined by the difference between output and input voltage and the inductor value.

    Answer

    inductance

  30. 30
    The same rising-and-falling current waveform analysis can be applied to other converter types by using their appropriate current
    _____
    .
    Hint

    Different converter topologies have different rising and falling rates.

    Answer

    slopes

  31. 31
    Compared with duty-ratio control, peak current mode control gives direct control over the
    _____
    current.
    Hint

    This is the current sensed by the inner loop and limited each cycle.

    Answer

    inductor

  32. 32
    A useful benefit of peak current control is automatic
    _____
    limiting.
    Hint

    The switch turns off when the sensed current reaches its commanded threshold.

    Answer

    current

  33. 33
    In a boost converter, peak current control can limit current only while the output voltage is greater than the
    _____
    voltage.
    Hint

    A short circuit can defeat the described current-control mechanism if this voltage condition is not met.

    Answer

    input

  34. 34
    If the output voltage falls below its reference, the outer-loop error grows and the compensator increases the
    _____
    command.
    Hint

    The larger command makes the inductor carry more current to supply the output.

    Answer

    peak current

  35. 35
    The inductor current multiplied by the input voltage indicates the power drawn from the
    _____
    .
    Hint

    This is the source from which the converter draws energy.

    Answer

    input

  36. 36
    When current is sensed only while the switch is on, a small resistor can be placed in the switch-current path to measure the
    _____
    .
    Hint

    The measured switch quantity provides the comparison signal for the current controller.

    Answer

    current

  37. 37
    Instead of a separate sensing resistor, the switch’s own
    _____
    can sometimes be used to sense current.
    Hint

    A voltage associated with this property can indicate the current through the switch.

    Answer

    resistance

  38. 38
    Directly deriving a current-mode model by averaging the switching behavior is described as mathematically
    _____
    .
    Hint

    The approach encounters a substantial mathematical obstacle.

    Answer

    difficult

  39. 39
    A simpler route to a current-mode model is to relate the peak current to the
    _____
    and substitute that relation into an existing averaged model.
    Hint

    The existing model already uses this quantity as its control variable.

    Answer

    duty ratio

  40. 40
    The waveform-based estimate of local average inductor current is made by averaging the current over a switching-period
    _____
    .
    Hint

    It is a time interval over which the waveform is considered.

    Answer

    window

  41. 41
    The relation between local average inductor current, peak current, duty ratio, current slopes, and the compensating ramp is obtained using a
    _____
    approximation.
    Hint

    The method estimates averages using the areas of triangular regions in the waveform.

    Answer

    geometric

  42. 42
    When calculating the local average from the current waveform, the areas of the rising-side and falling-side triangles are
    _____
    from the peak-related value.
    Hint

    These triangular areas lie outside the portion represented by the average current.

    Answer

    subtracted

  43. 43
    The waveform average over the chosen window is an approximation to the local average current; it is not exactly equal at every point in
    _____
    .
    Hint

    The approximation is tied to the waveform’s value at a particular instant.

    Answer

    time

  44. 44
    For a different converter topology, the same modeling procedure can be used after substituting that converter’s appropriate rising and falling current
    _____
    .
    Hint

    These determine the shape of the current waveform used in the geometric approximation.

    Answer

    slopes

  45. 45
    Replacing duty-ratio variation with peak-current variation produces a new transfer function from peak-current variation to output-voltage
    _____
    .
    Hint

    The transfer function describes how the regulated output responds to the new control input.

    Answer

    variation

  46. 46
    The peak-current model retains the converter’s right-half-plane zero because that feature comes from how the converter processes
    _____
    .
    Hint

    The zero reflects the physical operation of the plant rather than a mathematical modeling artifact.

    Answer

    energy

  47. 47
    With current mode control, the two lightly damped poles tend to become a dominant pole and a second pole at a much
    _____
    frequency.
    Hint

    The second pole is separated from the dominant, lower-frequency pole.

    Answer

    higher

  48. 48
    The dominant current-mode pole is largely associated with inductor current charging and discharging the output
    _____
    .
    Hint

    This component stores the output energy and its voltage changes as current flows into or out of it.

    Answer

    capacitor

  49. 49
    Without a compensating ramp, peak current control can fail to repeat the same waveform every switching
    _____
    .
    Hint

    The desired steady state repeats after each interval of the switching clock.

    Answer

    period

  50. 50
    A current waveform that repeats every other switching cycle is an example of a
    _____
    oscillation.
    Hint

    Its repetition frequency is below the switching frequency.

    Answer

    subharmonic

  51. 51
    The broader name for failure of the current ripple to settle into periodic steady-state behavior is
    _____
    instability.
    Hint

    The term refers to the varying current waveform from cycle to cycle.

    Answer

    ripple

  52. 52
    Without sufficient slope compensation, the cycle-to-cycle behavior can sometimes become
    _____
    rather than merely periodic.
    Hint

    This describes behavior that does not settle into a regular repeating pattern.

    Answer

    chaotic

  53. 53
    A ripple instability can produce larger current ripple and more
    _____
    control behavior.
    Hint

    The switching duty ratio varies unpredictably from cycle to cycle.

    Answer

    jittery

  54. 54
    The ripple instability may introduce lower-frequency content into the converter’s
    _____
    .
    Hint

    This is the signal that can be affected by the enlarged, irregular ripple.

    Answer

    output

  55. 55
    Adding a sufficiently large compensating ramp makes the current ripple decay toward a fixed repeating
    _____
    .
    Hint

    This is the desired stable pattern that repeats each switching cycle.

    Answer

    waveform

  56. 56
    The compensating ramp is practical to implement partly because converters already use a ramp generator to establish the switching
    _____
    .
    Hint

    The ramp’s threshold crossing can set the timing of the oscillator.

    Answer

    clock frequency

  57. 57
    In the cycle-to-cycle error analysis, stability requires the magnitude of the error multiplier to be
    _____
    than one.
    Hint

    For the error to decay from one cycle to the next, its multiplying factor must have magnitude below this threshold.

    Answer

    less

  58. 58
    In the error multiplier, increasing the compensating-ramp slope tends to reduce the multiplier’s magnitude by increasing its denominator and reducing its
    _____
    .
    Hint

    This is the other part of a fraction besides its denominator.

    Answer

    numerator

  59. 59
    If the compensating-ramp slope equals the falling-current slope M2, the cycle-to-cycle error can disappear in
    _____
    cycle.
    Hint

    The error multiplier becomes zero in this case.

    Answer

    one

  60. 60
    For the boost converter with no slope compensation, ripple instability becomes a concern as the duty ratio approaches or exceeds
    _____
    percent.
    Hint

    This is the halfway point of a switching period.

    Answer

    50

  61. 61
    A larger compensating ramp is not always better because it changes the converter’s linearized
    _____
    .
    Hint

    This is why the ramp value must be considered when designing the controller.

    Answer

    dynamics

  62. 62
    If the compensating ramp is made too large, the converter can again develop
    _____
    poles.
    Hint

    These poles would make oscillatory behavior difficult to control.

    Answer

    undamped

  63. 63
    A practical design chooses a compensating ramp large enough to stabilize the ripple but avoids making it much
    _____
    than necessary.
    Hint

    Excessive ramp slope can worsen the pole locations.

    Answer

    larger

  64. 64
    The compensating-ramp slope is commonly set with a
    _____
    rather than continuously adjusted for every operating condition.
    Hint

    It is a simple circuit component often used to set a control parameter.

    Answer

    resistor

  65. 65
    Peak current mode control is widely used in PWM DC-to-DC converters and is found in many control
    _____
    .
    Hint

    These integrated components implement converter control functions.

    Answer

    chips

  66. 66
    Peak current mode control is the most common version of the broader current mode control idea, while another version is
    _____
    control.
    Hint

    This alternative focuses on the low point of the current waveform rather than its peak.

    Answer

    valley

  67. 67
    Current mode control makes the converter easier to compensate because its dominant pole is more clearly separated from the higher-frequency
    _____
    .
    Hint

    This is the other pole in the second-order model.

    Answer

    pole

  68. 68
    Even with current mode control, the designer must account for the right-half-plane zero when designing the
    _____
    loop.
    Hint

    This loop regulates output voltage using the current reference.

    Answer

    outer

  69. 69
    The inner current loop does not make the converter truly first order; it remains a
    _____
    -order system.
    Hint

    The converter still has two state variables and two poles.

    Answer

    second

  70. 70
    At low boost ratios, the ripple instability may disappear even without a compensating ramp, whereas higher boost ratios can produce more
    _____
    behavior.
    Hint

    The current ripple may vary from cycle to cycle instead of settling into a regular pattern.

    Answer

    irregular

  71. 71
    When the compensating ramp is enabled in the demonstration, the converter returns to stable periodic steady-state
    _____
    .
    Hint

    This is the desired repeating behavior from cycle to cycle.

    Answer

    operation

  72. 72
    To analyze a current-mode converter, the averaged and linearized converter modeling approach is extended with an additional
    _____
    relating peak current and duty ratio.
    Hint

    This is the extra modeling operation needed to form the current-mode model.

    Answer

    step

1 of 72
Question 1 of 72

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent