Boost Converter Control
- 54Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
Which quantities are the two state variables identified for the boost converter?
Which quantities are the two state variables identified for the boost converter?
54 questions
- 1
Which quantities are the two state variables identified for the boost converter?
- A
The load resistance and the output voltage
- B
The inductor current and the capacitor voltage
- C
The duty ratio and the input voltage
- D
The switch current and the switching frequency
Correct answer
BThe inductor current and the capacitor voltage
Explanation
The converter's two state variables are the inductor current IL and the capacitor voltage VC.
- A
- 2
In the averaged converter model, what does the duty ratio represent?
- A
The local average of the inductor current IL(t)
- B
The ratio of output voltage to load resistance
- C
The local average of the switch-control function q(t)
- D
The fraction of each cycle spent discharging the capacitor
Correct answer
CThe local average of the switch-control function q(t)
Explanation
The duty ratio is the local average of the switching control function q(t), which modulates the converter.
- A
- 3
What input-output relationship does the converter transfer function H(s) describe in the voltage-mode model?
- A
Small variations in duty ratio to small variations in output voltage
- B
Small variations in output voltage to small variations in duty ratio
- C
Small variations in capacitor voltage to small variations in inductor current
- D
Small variations in load resistance to small variations in input voltage
Correct answer
ASmall variations in duty ratio to small variations in output voltage
Explanation
The model H(s) maps variations in duty ratio to variations in output voltage.
- A
- 4
Why can a converter's small-signal dynamics change when its input voltage changes, even if its output voltage stays the same?
- A
The inductor and capacitor stop forming a second-order system
- B
The capacitor's state variable becomes the load resistance
- C
The output-voltage reference directly changes the switching frequency
- D
The switching modulation and its steady-state operating point affect the dynamics
Correct answer
DThe switching modulation and its steady-state operating point affect the dynamics
Explanation
Switching modulation mediates the inductor-capacitor dynamics, and its steady-state value depends on the input and output voltages. Changing the operating point can therefore change the small-signal dynamics.
- A
- 5
What physical behavior underlies the converter's second-order response?
- A
Repeated switching of the capacitor voltage, damped by the control reference
- B
Oscillation of energy between the inductor and capacitor, damped by resistance
- C
Oscillation of energy between the input source and switch, damped by capacitance
- D
Repeated charging of the inductor by the load, damped by the input voltage
Correct answer
BOscillation of energy between the inductor and capacitor, damped by resistance
Explanation
The second-order response reflects oscillations between the inductor and capacitor, with the load resistance providing damping.
- A
- 6
What is the physical significance of the right-half-plane zero in the converter transfer function?
- A
It results solely from using a compensator in the feedback loop
- B
It reflects the converter's energy-processing behavior after an input change
- C
It is an artifact introduced only by linearizing the converter equations
- D
It indicates that the load resistance has become negative
Correct answer
BIt reflects the converter's energy-processing behavior after an input change
Explanation
The right-half-plane zero arises from how the converter processes energy; it is not merely a mathematical artifact of the model.
- A
- 7
What mainly determines the damping of the converter's lightly damped inductor-capacitor poles in the basic model?
- A
The reference voltage
- B
The switching period alone
- C
The compensator's input impedance
- D
The load resistance
Correct answer
DThe load resistance
Explanation
The load resistance damps the inductor-capacitor oscillations, so the pole damping depends on the load resistance.
- A
- 8
How can adding a resistor-capacitor damping network improve the plant dynamics?
- A
The capacitor acts nearly as a short near the oscillation corner frequency, letting the added resistor provide damping
- B
The resistor acts nearly as a short at every frequency, removing the inductor state
- C
The resistor changes the converter's input voltage so the right-half-plane zero disappears
- D
The capacitor blocks current at the corner frequency, forcing the poles to become zeros
Correct answer
AThe capacitor acts nearly as a short near the oscillation corner frequency, letting the added resistor provide damping
Explanation
Choosing the added capacitor to act as a short near the inductor-capacitor corner frequency lets the added resistor damp the oscillation. The added network costs hardware, including a potentially large capacitor.
- A
- 9
What does full-state feedback suggest when a controllable system has unsatisfactory dynamics?
- A
Feed back all state variables to gain greater ability to place the system dynamics
- B
Feed back only the output voltage to avoid affecting the system poles
- C
Replace the state variables with the switching frequency
- D
Remove the plant and regulate the reference directly
Correct answer
AFeed back all state variables to gain greater ability to place the system dynamics
Explanation
For a controllable system, full-state feedback uses all state variables and can provide more freedom to shape the dynamics.
- A
- 10
In current-mode control, what is the role of the inner loop?
- A
It compares input voltage with a command and sets the capacitor value
- B
It compares inductor current with a command and controls the switching action
- C
It compares duty ratio with a command and controls the switching frequency
- D
It compares output voltage with a command and sets the load resistance
Correct answer
BIt compares inductor current with a command and controls the switching action
Explanation
The fast inner loop uses the inductor-current signal and a current command to determine the switching action.
- A
- 11
What is the role of the outer voltage loop in current-mode control?
- A
It compares inductor current with its reference and directly sets the load
- B
It compares switch current with its reference and sets the input voltage
- C
It compares duty ratio with its reference and adjusts the capacitor current
- D
It compares output voltage with its reference and adjusts the current command
Correct answer
DIt compares output voltage with its reference and adjusts the current command
Explanation
The outer loop processes the output-voltage error through a compensator and uses it to generate the current reference.
- A
- 12
Why is the inner loop described as fast and the outer loop as slow?
- A
The inner loop operates below the resonant frequency, while the outer loop operates above it
- B
The inner loop regulates voltage, while the outer loop regulates current
- C
The inner loop acts cycle by cycle, while the outer-loop command should not change rapidly within a switching cycle
- D
The inner loop acts only at startup, while the outer loop acts once per switching cycle
Correct answer
CThe inner loop acts cycle by cycle, while the outer-loop command should not change rapidly within a switching cycle
Explanation
The inner loop responds on a cycle-by-cycle basis. The outer loop changes the current command more slowly; averaged models are intended for behavior slow compared with switching.
- A
- 13
How does peak-current control determine when to turn off the switch during a cycle?
- A
It turns the switch off after a fixed fraction of the cycle regardless of current
- B
It turns the switch off when sensed inductor current exceeds the commanded peak threshold
- C
It turns the switch off when the inductor current reaches zero
- D
It turns the switch off when output voltage reaches its reference within that cycle
Correct answer
BIt turns the switch off when sensed inductor current exceeds the commanded peak threshold
Explanation
The switch turns on at the start of a cycle and turns off when the inductor current reaches the commanded threshold, adjusted by the compensating ramp.
- A
- 14
What does the compensating ramp do to the peak-current threshold within each switching cycle?
- A
It replaces the peak-current command with the output-voltage reference
- B
It makes the threshold increase with time from the peak-current command
- C
It holds the threshold constant while the inductor current decreases
- D
It makes the threshold decrease with time from the peak-current command
Correct answer
DIt makes the threshold decrease with time from the peak-current command
Explanation
The ramp has slope −MC and is subtracted from the peak-current command, so the threshold decreases during the cycle.
- A
- 15
How does a change in load that causes the output voltage to fall below its reference lead to a higher current command?
- A
The voltage error decreases, the compensator lowers the peak-current command, and the inductor supplies more current
- B
The voltage error increases, the compensator raises the peak-current command, and the inductor supplies more current
- C
The current loop raises the output reference, and the compensator reduces the peak-current command
- D
The switching frequency falls, and the inductor supplies more current without changing its command
Correct answer
BThe voltage error increases, the compensator raises the peak-current command, and the inductor supplies more current
Explanation
An output voltage below its reference increases the voltage error. The outer compensator can raise the peak-current command, leading to more inductor current and energy delivered to the output.
- A
- 16
Why does the peak-current command provide an indirect means of controlling input power?
- A
The peak-current command sets the load resistance in each cycle
- B
The peak-current command directly changes the input voltage
- C
The inductor current determines the capacitor's physical size
- D
The inductor current determines how much power is drawn from the input voltage
Correct answer
DThe inductor current determines how much power is drawn from the input voltage
Explanation
The current drawn from the input is related to input voltage multiplied by current, so controlling inductor current indirectly controls the power drawn.
- A
- 17
Why is the current-mode scheme described as an implicit way to set duty ratio?
- A
The output voltage sets the switching period without sensing current
- B
The turn-off time is determined by when current reaches a threshold rather than by directly specifying a fixed duty ratio
- C
The duty ratio is fixed by the load resistance before each cycle begins
- D
The compensator computes duty ratio from the capacitor voltage alone
Correct answer
BThe turn-off time is determined by when current reaches a threshold rather than by directly specifying a fixed duty ratio
Explanation
The switch turns off when the sensed current reaches the commanded threshold, so the duty ratio emerges from the current waveform rather than being explicitly prescribed.
- A
- 18
Why does the direct derivation of a current-mode averaged model become difficult?
- A
The switching event depends on the inductor current, complicating direct averaging and linearization
- B
The duty ratio cannot be related to any converter waveform
- C
The converter has no state variables that can be averaged
- D
The output voltage is constant during every switching cycle
Correct answer
AThe switching event depends on the inductor current, complicating direct averaging and linearization
Explanation
In current-mode control, switching times depend on the current threshold crossing, making direct averaged-model derivation mathematically difficult.
- A
- 19
What modeling strategy allows an existing duty-ratio model to be adapted for peak-current control?
- A
Assume the right-half-plane zero is absent and use the voltage reference as the input
- B
Discard the existing model and replace both state variables with the peak current
- C
Derive a relation between load resistance and switching frequency, then remove the duty ratio
- D
Derive a relation between peak current and duty ratio, then substitute it into the existing linearized equations
Correct answer
DDerive a relation between peak current and duty ratio, then substitute it into the existing linearized equations
Explanation
The method relates peak-current variation to duty-ratio variation and substitutes that relationship into the existing linearized averaged equations.
- A
- 20
What geometric approximation is used to relate the inductor waveform to its local average?
- A
Approximate the local average current by the area under the compensating ramp alone
- B
Approximate the local average current by the average of the inductor-current waveform over a switching-period window
- C
Approximate the local average current by the maximum current reached over several switching periods
- D
Approximate the local average current by the current at the beginning of each cycle
Correct answer
BApproximate the local average current by the average of the inductor-current waveform over a switching-period window
Explanation
The derivation approximates local average inductor current by averaging the inductor-current waveform over a window of length T.
- A
- 21
In the boost-converter waveform used for the peak-current model, what are the rising and falling inductor-current slopes?
- A
M1=L/u and M2=L/(V−u)
- B
M1=V/L and M2=u/L
- C
M1=(V−u)/L and M2=u/L
- D
M1=u/L and M2=(V−u)/L
Correct answer
DM1=u/L and M2=(V−u)/L
Explanation
For the boost converter, the rising slope is M1=u/L, and the magnitude of the falling slope is M2=(V−u)/L.
- A
- 22
Which expression best describes the geometric estimate of the local average inductor current over one cycle?
- A
IˉL≈Ipeak−MCdT−21d2TM1−21(1−d)2TM2
- B
IˉL≈Ipeak+MCdT+21d2TM1+21(1−d)2TM2
- C
IˉL≈Ipeak−MCT−21dTM1−21(1−d)TM2
- D
IˉL≈Ipeak−M1dT−M2(1−d)T
Correct answer
AIˉL≈Ipeak−MCdT−21d2TM1−21(1−d)2TM2
Explanation
The estimate starts with the peak threshold after the ramp reduction, Ipeak−MCdT, then subtracts the normalized areas of the rising- and falling-segment triangles.
- A
- 23
Why are triangular areas subtracted when estimating average inductor current from the peak threshold?
- A
The duty ratio measures only the areas below the current waveform
- B
The compensating ramp adds triangular areas to the measured current
- C
The threshold-based level includes regions above the actual rising and falling current waveform
- D
The inductor current is negative throughout both parts of the cycle
Correct answer
CThe threshold-based level includes regions above the actual rising and falling current waveform
Explanation
The peak threshold is above portions of the actual inductor-current waveform. Subtracting the two triangular areas accounts for the difference when estimating the waveform's average.
- A
- 24
What should be changed when applying the same peak-current modeling procedure to a converter other than a boost converter?
- A
Replace the inductor-current waveform with the load-voltage waveform
- B
Keep the boost slopes and change only the output reference
- C
Remove the compensating ramp and assume the duty ratio is fixed
- D
Use that converter's appropriate rising and falling current slopes in the geometric relation
Correct answer
DUse that converter's appropriate rising and falling current slopes in the geometric relation
Explanation
The same geometric approach can be used for other converter topologies, but their appropriate inductor-current slopes must be used.
- A
- 25
After substituting the linearized peak-current relation into the converter equations, what becomes the control variable in the resulting model?
- A
The capacitor-value variation C~
- B
The switching-period variation T~
- C
The load-resistance variation R~
- D
The peak-current variation I~peak
Correct answer
DThe peak-current variation I~peak
Explanation
The substitution eliminates duty-ratio variation as the control variable and introduces peak-current variation, allowing a transfer function from I~peak to output-voltage variation.
- A
- 26
What is a practical reason the cycle-by-cycle current loop can provide current limiting?
- A
It guarantees that current is limited even if the output is shorted in a boost converter
- B
It removes the load from the converter at the start of each cycle
- C
It turns off the switch when sensed inductor current reaches the commanded peak threshold
- D
It forces the input voltage to zero whenever the output voltage falls
Correct answer
CIt turns off the switch when sensed inductor current reaches the commanded peak threshold
Explanation
A peak threshold can limit the inductor current processed during each cycle. In a boost converter, this does not guarantee control during an output short circuit, because the switch cannot control the inductor current in that condition.
- A
- 27
Under what condition does peak-current control provide the described current-limiting protection in a boost converter?
- A
Only when the output is short-circuited
- B
When the output voltage is greater than the input voltage
- C
When the output voltage is less than the input voltage
- D
Only when the input and output voltages are equal
Correct answer
BWhen the output voltage is greater than the input voltage
Explanation
The stated current-limiting behavior applies when the boost converter's output voltage is greater than its input voltage. A short circuit is an exception because the switch cannot control the inductor current there.
- A
- 28
Why can sensing switch current provide the information needed for peak-current control?
- A
The switch current equals the output voltage whenever the switch is off
- B
The switch current is identical to the load current throughout the cycle
- C
The switch current measures the compensating ramp without sensing the inductor
- D
While the switch is on, its current corresponds to the inductor current being compared
Correct answer
DWhile the switch is on, its current corresponds to the inductor current being compared
Explanation
The inductor current is observed through the switch during the switch-on interval, so a small series resistor or the switch's own resistance can be used to sense it.
- A
- 29
What change in the current-mode transfer function is typically associated with improved pole damping?
- A
A single pole with the right-half-plane zero removed
- B
Two nearly coincident, lightly damped poles at low frequency
- C
A pair of right-half-plane poles and no finite zero
- D
A dominant lower-frequency pole and a much higher-frequency second pole
Correct answer
DA dominant lower-frequency pole and a much higher-frequency second pole
Explanation
Current-mode control typically produces a dominant low-frequency pole and a much higher-frequency second pole, rather than the two closely problematic, lightly damped poles of the basic voltage-mode plant.
- A
- 30
Why is it inaccurate to say that current-mode control turns the converter into a first-order system?
- A
The converter becomes first order only if the right-half-plane zero is retained
- B
The current loop removes both converter state variables but leaves two zeros
- C
The converter still has two state variables and remains a second-order system, though one pole may dominate
- D
The outer loop adds a second state variable to an otherwise stateless plant
Correct answer
CThe converter still has two state variables and remains a second-order system, though one pole may dominate
Explanation
Current-mode control does not remove the two state variables. It often makes one pole dominant and the other much higher in frequency, which can make the system behave approximately like a first-order system over a range.
- A
- 31
What happens to the right-half-plane zero when peak-current control is used?
- A
It disappears because the inner loop directly controls inductor current
- B
It becomes a left-half-plane pole when the compensating ramp is added
- C
It remains because it is tied to the converter's energy-processing behavior
- D
It appears only when the outer voltage loop is removed
Correct answer
CIt remains because it is tied to the converter's energy-processing behavior
Explanation
The right-half-plane zero persists under current-mode control because it reflects the converter's underlying energy-processing behavior.
- A
- 32
Which combination best describes the principal control benefits of peak-current mode?
- A
Fixed pole locations across all operating points, no current sensing, and automatic short-circuit control
- B
Removal of every converter zero, elimination of switching ripple, and no need for voltage feedback
- C
Improved pole behavior, cycle-by-cycle current limiting, and a more manageable voltage-loop design
- D
A first-order plant, constant duty ratio, and independence from the load
Correct answer
CImproved pole behavior, cycle-by-cycle current limiting, and a more manageable voltage-loop design
Explanation
Peak-current control commonly improves the pole arrangement, provides cycle-by-cycle current control, and makes the outer-loop dynamics easier to compensate, although the right-half-plane zero remains.
- A
- 33
What happens to the inductor-current ripple when the peak-current loop exhibits subharmonic oscillation?
- A
It disappears while the output voltage becomes unregulated
- B
It becomes constant but shifts to the switching frequency
- C
It can become larger and vary from cycle to cycle
- D
It becomes zero because the current reaches the same peak each cycle
Correct answer
CIt can become larger and vary from cycle to cycle
Explanation
Without adequate ramp compensation, the waveform may alternate between different cycle behaviors, producing larger, irregular ripple and lower-frequency content.
- A
- 34
What is meant by subharmonic oscillation in peak-current control?
- A
The switching waveform repeats at exactly the switching frequency with identical cycles
- B
The compensating ramp repeats twice within every switching cycle
- C
The output voltage oscillates only at a frequency above the switching frequency
- D
The switching waveform repeats over multiple switching cycles rather than settling to the same pattern each cycle
Correct answer
DThe switching waveform repeats over multiple switching cycles rather than settling to the same pattern each cycle
Explanation
Subharmonic oscillation occurs when the current waveform does not repeat identically each switching cycle; for example, it may alternate between two cycle patterns.
- A
- 35
What broader instability can occur when the inductor-current ripple fails to settle into periodic steady-state behavior?
- A
The right-half-plane zero changes into a right-half-plane pole
- B
The converter necessarily stops switching permanently
- C
The output voltage is forced to equal the input voltage
- D
The behavior can become irregular or even chaotic
Correct answer
DThe behavior can become irregular or even chaotic
Explanation
The ripple may alternate periodically or, in some operating conditions, exhibit more irregular behavior described as chaotic.
- A
- 36
Why can ripple instability be undesirable even if the output voltage remains regulated?
- A
It necessarily destroys the voltage reference and removes current sensing
- B
It forces the converter poles to become exactly undamped
- C
It can increase ripple, create lower-frequency content, and make switching behavior jittery
- D
It prevents the outer loop from changing the current command
Correct answer
CIt can increase ripple, create lower-frequency content, and make switching behavior jittery
Explanation
The converter may still regulate at a broad level, but irregular switching can increase ripple, introduce lower-frequency content, and make the control behavior jittery.
- A
- 37
How does adding a sufficiently large compensating-ramp slope affect cycle-to-cycle ripple error?
- A
It converts the error into a fixed duty-ratio offset
- B
It holds the error constant while the output voltage changes
- C
It makes the error decay toward zero over successive cycles
- D
It makes the error grow linearly until the switch stops turning on
Correct answer
CIt makes the error decay toward zero over successive cycles
Explanation
A sufficiently large stabilizing ramp makes deviations from periodic steady state decay over successive switching cycles.
- A
- 38
For the cycle-to-cycle error model, what condition ensures that an initial ripple error decays?
- A
MC−M1MC+M2>1
- B
MCM1−M2=1
- C
MC+M1MC−M2<1
- D
M1+M2MC>1
Correct answer
CMC+M1MC−M2<1
Explanation
The cycle-to-cycle error is multiplied by MC+M1MC−M2. Its magnitude must be less than 1 for the error to decay.
- A
- 39
What happens to the cycle-to-cycle error in the idealized model if MC=M2?
- A
The error remains unchanged after every cycle
- B
The error alternates sign without changing magnitude
- C
The error becomes zero after one cycle
- D
The error doubles after every cycle
Correct answer
CThe error becomes zero after one cycle
Explanation
When MC=M2, the numerator of the error multiplier MC−M2 is zero, so the initial error disappears in one cycle in this model.
- A
- 40
For a boost converter with no compensating ramp, what duty-ratio condition is associated with ripple instability?
- A
The duty ratio is greater than 0.5
- B
The duty ratio is exactly zero
- C
The duty ratio is less than 0.25
- D
The duty ratio is always unstable, regardless of its value
Correct answer
AThe duty ratio is greater than 0.5
Explanation
With MC=0, the error multiplier's magnitude for the boost converter exceeds 1 when the duty ratio is greater than 0.5, leading to ripple instability.
- A
- 41
Why does a ramp generator already present in many converters make slope compensation convenient to implement?
- A
The timing ramp directly sets the load resistance
- B
The timing ramp eliminates the need to sense inductor current
- C
A portion of the existing timing ramp can be used to create the compensating ramp
- D
The timing ramp automatically measures the output voltage without additional circuitry
Correct answer
CA portion of the existing timing ramp can be used to create the compensating ramp
Explanation
Converters commonly generate a ramp to establish the switching clock. A portion of this available ramp can be added to or subtracted from the current command to provide compensation.
- A
- 42
What is the likely effect of making the compensating-ramp slope excessively large?
- A
The converter's pole locations shift, potentially becoming poorly damped again
- B
The inductor current becomes independent of its reference
- C
The converter becomes a first-order system at every operating point
- D
The right-half-plane zero disappears and all poles become fixed
Correct answer
AThe converter's pole locations shift, potentially becoming poorly damped again
Explanation
The compensating-ramp slope appears in the current-mode averaged model. Increasing it excessively can shift the poles and undermine the improved damping.
- A
- 43
How should the compensating-ramp slope generally be selected?
- A
Make it zero so the current threshold remains constant
- B
Make it large enough to stabilize the ripple, but avoid making it larger than necessary
- C
Make it as large as possible so the current loop becomes first order
- D
Set it equal to the output voltage in every converter
Correct answer
BMake it large enough to stabilize the ripple, but avoid making it larger than necessary
Explanation
The slope should be sufficient to make ripple errors decay, but an unnecessarily large slope can worsen the pole locations and move behavior toward that of duty-ratio control.
- A
- 44
Why can making the compensating ramp too large make current-mode behavior resemble voltage-mode behavior?
- A
A larger ramp makes the switch operate continuously rather than switching
- B
A larger ramp changes the averaged dynamics and can erode the distinctive pole arrangement of current-mode control
- C
A larger ramp eliminates the converter's inductor and capacitor states
- D
A larger ramp removes current feedback and directly senses output voltage
Correct answer
BA larger ramp changes the averaged dynamics and can erode the distinctive pole arrangement of current-mode control
Explanation
As MC increases, the modeled poles move; with an excessively large slope, the current-mode transfer function can resemble the less favorable dynamics of duty-ratio or voltage-mode control.
- A
- 45
What determines the current slopes used to select a stabilizing-ramp slope for a particular converter?
- A
The compensator's integration constant alone
- B
The voltage reference alone
- C
The converter topology and its operating conditions
- D
The physical size of the output capacitor alone
Correct answer
CThe converter topology and its operating conditions
Explanation
The relevant rising and falling current slopes depend on the converter topology and operating point, so they inform the choice of compensating ramp.
- A
- 46
How is the compensating-ramp slope commonly set in a practical design?
- A
By removing the switching clock and measuring the output ripple
- B
By changing the inductor value automatically every cycle
- C
As a chosen fixed slope, often set with a resistor
- D
By setting it equal to the instantaneous load current
Correct answer
CAs a chosen fixed slope, often set with a resistor
Explanation
Designers commonly choose a ramp slope and set it with a component such as a resistor. More adaptive choices may be considered for converters operating over a very wide range.
- A
- 47
What behavior is expected when the compensating ramp is enabled and properly sized?
- A
The duty ratio alternates indefinitely between long and short values
- B
The inductor current becomes constant throughout the switching cycle
- C
The output voltage stops responding to the outer-loop command
- D
The current ripple settles into a repeatable pattern from cycle to cycle
Correct answer
DThe current ripple settles into a repeatable pattern from cycle to cycle
Explanation
With adequate compensation, the current waveform tends to settle into periodic steady-state operation, repeating its pattern each cycle.
- A
- 48
How can a boost converter's boosting ratio affect the severity of ripple instability when no compensating ramp is used?
- A
A lower boosting ratio necessarily causes chaotic operation
- B
The boosting ratio has no relationship to the ripple behavior
- C
A higher boosting ratio can make the irregular ripple behavior more pronounced
- D
A higher boosting ratio always removes subharmonic oscillation
Correct answer
CA higher boosting ratio can make the irregular ripple behavior more pronounced
Explanation
The described behavior tends to be less problematic at low boosting ratios and more pronounced as the boosting ratio increases.
- A
- 49
Which term names the most common version of current-mode control described here?
- A
Peak current mode control
- B
Direct duty-ratio control
- C
Average voltage mode control
- D
Valley voltage mode control
Correct answer
APeak current mode control
Explanation
The described method controls the peak of the inductor current and is therefore called peak current mode control. Valley control is another version of the broader idea.
- A
- 50
What is the distinction between peak-current control and valley-current control?
- A
Peak control sets switching frequency, whereas valley control removes switching
- B
Peak control uses voltage feedback, whereas valley control cannot use current feedback
- C
Peak control regulates output voltage, whereas valley control regulates input voltage
- D
Peak control regulates the current peak, whereas valley control regulates the current valley
Correct answer
DPeak control regulates the current peak, whereas valley control regulates the current valley
Explanation
Peak current mode controls the peak of the inductor-current waveform; valley control is a different version that controls its valley.
- A
- 51
How should the phrase “current-mode control makes the inductor a commandable current source” be interpreted?
- A
It means the inductor current follows its command instantaneously
- B
It proves that the capacitor state no longer affects the output
- C
It means the voltage loop is unnecessary once current is sensed
- D
It is a useful simplification, but the converter still has two state variables and second-order dynamics
Correct answer
DIt is a useful simplification, but the converter still has two state variables and second-order dynamics
Explanation
Treating the inductor as a commandable current source is a helpful way to think about the inner loop, but it is an oversimplification: the converter remains a second-order system.
- A
- 52
Why is peak-current control widely used in PWM DC-to-DC converter control chips?
- A
It removes the need for switching devices and output capacitors
- B
It eliminates the need for any voltage regulation loop
- C
It offers practical current control and often makes the outer-loop plant easier to compensate
- D
It guarantees identical dynamics at every input and output voltage
Correct answer
CIt offers practical current control and often makes the outer-loop plant easier to compensate
Explanation
Peak-current control is widely used because it provides cycle-by-cycle current control and typically improves the dynamics presented to the outer voltage loop, though it does not remove all plant limitations.
- A
- 53
What is a likely design tradeoff between adding a damping network and using current-mode control?
- A
A damping network eliminates the right-half-plane zero, while current-mode control eliminates all poles
- B
A damping network sets the current reference, while current-mode control sets the load resistance
- C
A damping network removes current sensing, while current-mode control requires a larger output capacitor
- D
A damping network can improve plant damping but requires added hardware, while current-mode control can improve dynamics through feedback
Correct answer
DA damping network can improve plant damping but requires added hardware, while current-mode control can improve dynamics through feedback
Explanation
Adding a damping network can improve pole damping but requires components such as a large capacitor. Current-mode control instead uses current feedback to improve the dynamics presented for control.
- A
- 54
What does the output-voltage compensator ultimately regulate in a current-mode converter?
- A
The input voltage, by adjusting the capacitor voltage
- B
The switching frequency, by adjusting the output reference
- C
The inductor current, by adjusting the load resistance
- D
The output voltage, by adjusting the inductor-current reference
Correct answer
DThe output voltage, by adjusting the inductor-current reference
Explanation
The outer loop still regulates output voltage by comparing it with its reference and adjusting the current command sent to the inner loop.
- A