Controller Design Basics

Transcript

So, in the last lectures, in the last couple  of lectures what we saw were designing of   basic controller or compensating elements. The  basic elements were a proportional element,   a derivative element, an integral element or a  combination of proportional and a derivative or   a proportional integral control or a combination  of all of these three these elements. And through   some problems we saw well when can we add a PI,  when can we not add a PI, what are the effects of adding just a proportional controller, what are  the effects of adding just a derivative controller   and so on and those problems gave us little idea  of what happens actually when we try to design   controllers, to do it blindly without worrying  about stability or not is what PI controller asks   us to be careful of right. The derivative control  we saw had it is in the transient response of the   system in case when a proportional control is  not good enough to stabilise my system. So,

what we will do here is to do a little  further more analysis of those components. So, what we did so far is well just to  sum up. So, we had a proportional element,   a derivative element and an integral element,  the standard thing is just to be the objective   being to track a certain reference at the  output. So, well proportional controller   its well what we saw was it very very simply  simple to implement, but it may not be able to   meet some specifications sometimes it is not  even good enough to stabilise the system.

Stability, so when I look at proportional and the  derivative control we saw that it actually had a   very good transient response it could stabilise  the systems and then based on the value of the K d   which added damping into the into a simple second  order system it provides more control over where I   should place my poles of the closed loop systems.  Integral control well it had well perfect tracking of constant reference inputs because it has a 0,  adds a 0 at the origin and I know that of type   one systems if the reference signal is a step then  I could track it perfectly. And it also had good   effect of rejection of constant disturbance inputs  where we saw that if the plant had some 0s at   sorry some poles at the origin they were not good  enough to neglect or reduce or reject the effect

of disturbance in that case we actually needed to  have a controller which had a pole at the origin.   So, for second order systems all these  proportional derivative and integral control   they add to stability. I can also look at where to  place the poles placing the poles I know has lot   of effect on the relative stability of the system  perfect tracking of constant reference inputs and   also I could reject constant disturbances  with the help of an integral control.

So, what we will do here is to just get  little more understanding of this integral   and derivative actions and what are the practical  issues while I implement PID controllers and this   would lead us to some kind of approximation of  this PID components called the lead and the lag   compensation right. And then of course, we will  also look at these performance specifications   both in the time and the frequency domain and see  how they actually like connect to each other.

So, let’s start with a very basic first order  system with a proportional controller what do   I usually want to do is to track a reference at  the output. So, as long as a is greater than 0   I know that this system is stable and it will  have a steady state value of y equal to 0 right   some response like this. And through a feedback  controller I just want to see if I could try to   shift this steady state value to 1 right for  example, if I am just something is lying on

the table, if I were to lift it I will just need  some external force right can I just lift it to   some 1 meter above the ground right. So, here  as we were through a feedback controller can I   try to shift the steady state position to one. So, let’s try to understand does a proportional   controller help me help me achieve this. So,  what is the structure? So I have the reference,   I have the output the error goes via K p and  the U p is K p times E s and this goes as a input to the controller and then generates  an output. So, typically what I would like   is e t should go to 0 as t goes to infinity  right or this steady state error should be   0 or which means that this y should track  this reference asymptomatically right.

So, let just try to understand this with the  help of the block diagram here right. So,   let’s just see with this help of this block  diagram just what do I want I want e to go to 0   as t goes to infinity or y to track r as time goes  to infinity let’s see how this propagates. So,   once e goes to 0 then I will have that this is 0.5  times 0 this is also 0. So, this will be 0 now,   what is this actually is - this actually is  computed to be this one which is actually 0,

now this is 0 I go back here and I compare this  with this I see that the error is actually not 0.   So, there is there is actually a contradiction  here I cannot have the steady state error to be   0 and in this setting it could be something else.  I am not really worried about that something else   I am just worried about keeping my steady state  error to 0 or y tracking r asymptotically right   which means that if this was assumed to be true  or if this was feasible it would mean that this

actual input to the plant would be 0.5 times  0 and the controller applies no input right   its natural state is 0 without applying any  input I cannot get any output here right. So,   the controller applies no input to the system to  maintain the system at the new steady state which   contradicts this is contradiction right because if  I want were to hold this at some non-zero steady   state the controller must supply some input right  the controller must apply some non-zero input to

the plant to maintain the output at some non-zero  value or a non-zero equilibrium if I may call. So,   therefore, in this case the steady state error  cannot be 0 we are only worried is the steady   state error 0 when I have a first order plant  with a proportional controller in the closed loop   tracking a step? well the answer is no. We also  know these answers via the time domain analysis,   we also know the answers via the error  constants which we had found out. Now, let’s say well I am not really worried  about having a steady state error of 0,   but some number. So, if I take this plant  controller configuration then I can compute   that the error is point one right. So, this  is again for follows the first order system   analysis which were in the earlier course I  think module four or something like that.

Now let us see how is this consistent. So, there  is a steady state error of 0.1 this error gets   multiplied by 9 and I have a input at 0.1, input  signal here as 0.9 and then the output because   of this input will be 0.9 at steady state. So, I  am holding this guy at 0.9, but to hold this guy   at 0.9 I am actually having a non-zero input  right which is actually also 0.9 right. So,   I can with some adjustment of this guy reduce  it reduce the steady state error, but of course, for the steady state error go to 0 this has  to go to infinity and again it will lead to   some other contradictions. The steady  state will error will never go to 0,   but it we can reduce it to some small number  depending on the choice of the K p right.   So, the proportional controller it reduces the  steady state error, but does not eliminate it   completely. Of course, there are practical  issues of noise amplification and things

like that when I choose K p to be very large it  may not be practically feasible sometimes and   could come up with some other issues ok. So, can I add an integral control? Well   integral control would mean that just add  an integrator here this would increase the   type of this system to 1 and I know by the error  constant analysis that type one system if I have   a step here I will track it perfectly right. So, what does it mean again in terms of this signals? So, if I compute the error signal then  the error is something like this and it goes to   0 asymptotically now the input has some value like  this right it has some input value even at steady   state and based on this input value the output  is tracking the reference asymptotically. So,   U p this guy is now one over s times e t or  in if I talk in terms of the time domain it   is an integral of the error right this signal you  integrate it and you get U p earlier it was just

getting multiplied if it was 0 it was 0.5 times 0.  If it was 5 its 0.5 times 5 and so on right. So,   the controller input is now the integral of  the error signal right. And when I do this   what I also observed is the controller output is  non-zero see it is all always non-zero. So, there   are some points here, the error goes to 0 error  goes to 0 and whatever, but the control input is   non-zero even though the error has gone to 0. Similarly, I could also show we also did this

in some problems earlier that when there is  a constant disturbance which could possibly   come from here the error due to disturbance  accumulates and it is used to reject the effect   of disturbance. So, in this case the output of  the controller is the integral of the error so   the controller output which is the input to the  plant right this guy is non-zero even though the   error has gone to 0 because you see here the error  has gone to 0 the input to the plant is non-zero

right and then for as it goes to 0 there is some  steady state value for the input right. Similarly,   analysis I could also do for the disturbance  rejection as we have seen in some problems   earlier. So, is that all, is life now  easy that just add an integrator and   then steady state errors are gone well  it also comes with one set of rules.   So, what are the important points to observe  when I have plant with integrator? When the

plant already has an integrator the integral  control may not be necessary for 0 steady state   error that we have also seen in problems earlier  that I had a second order system it was tracking   a step signal perfectly asymptotically right. So, and we also saw that the integrator in the   plant does not help in disturbances rejection  right and therefore, for this kind of scenarios   I would need to have an integral control  via the compensator or the controller.

Now second thing is called the integral wind up  phenomena and this is very very practical issue   right. So, first is well these guys are not always  stable right I have a pole at the origin right and   if I just it could at best be marginally stable  right. And then not only that when there is a   limit on the actuation capability let’s say my  actuation signal is some kind of force right   which I cannot just apply infinite force right  if I just buy an equipment which could give me

some force it is bounded by a above and below  by some values right that phenomena is usually   called as the actuator saturation right. So, in  this case well this is my controller input n. So,   the input to the controller from the from  the error it goes via this and this U p is   now has to go through some functions like this  because my control action or my actuator has a   limit here which does not allow the input force or  the input voltage to go beyond a certain value.

So, what happens here is that I may need if I  just you know roughly draw a graph I may need   an input which is somewhere here or an input  which is somewhere here n to drive the error   to 0 or to meet some performance specifications  and so on, but well my thing my controller via   this actuator could just give me you know may be  four volts even though I need 10 volts right. So,   in this case what happens is that the integral,  there will of course, an error. So, I need 10 volts, but all I am getting is 4 volts the error  will still keep on accumulating accumulating   accumulating and then the output could go  to very large values right. So, it does not   really work in cases where I have some kind of  an of limitation in my actuator capabilities.   So, that also I need to be careful of right  we will not really discuss on how these kind   of situations will be will be handled in practice  right, but this is good to know that it is it just

that the integral control action even though it  looks extremely beautiful , it looks very simple,   just 1 over s, it eliminates lots of steady  state errors, it rejects disturbances, but   it comes with two you know two of these this not  really drawbacks, but something which we should   be careful of while we are deciding a system. Also what we could observe is that an integral   control leads to sluggish close loop response  for a first order system. What does this mean?

Let's just take well normal proportional  controller and a plant as 1 over s plus 3,   the root locus will tell me that as K increases  this guy just runs away to infinity. Now,,   if I add an integral control which means I am  adding a pole at the origin then my root locus   is like somewhere here right here and here. So, I  am actually having my dominant say for a here for   a larger value of K and somewhere here if I just  put the same value of K here I might just end up

somewhere here. So, this means that for that  value of K where you know my pole in without   the integral action was say at minus 12 or minus  10 or somewhere in between this response is faster   than just having a poles or this complex poles  at minus 1.5 plus minus j something right which   means the response has becomes sluggish which  means my poles or what I would now define as   the dominant poles are now closer to the origin  and that might. So, here this system might be

oscillatory here they are not oscillatory ok. So, and then if I look at higher order plants   they may lead to instability as we had seen  in the problems slide. So, we just add some   cases where I just had j s square plus something  times s plus 1 and you get some constants here,   and no matter what the values of the constants  were this system is always unstable right.   Okay now, what about the original plus derivative  control action? The input to the plant now comes

out later where K p plus K d s times E s is K  p times e t plus K d times the derivative of   the error right. So, what we had seen earlier  in the first lecture of this module was that   a derivative control not only acts on the error,  but also on the rate of change of the error which   improves the relative stability right. So, we are  adding a zero to the open loop transfer function   in the left half plane and this zero has the  effect of pulling the root locus to the left,

right? Away from the imaginary axis in the  stable region of the more away I am from the   imaginary axis the more I can say that I am  more, more and more relatively stable right.   And not only that right the derivative term is  in some sense it has some anticipatory effect   or some anticipatory behaviour it predicts how  fast the error is changing and the and therefore,   it could take corrective actions much better  than if I wouldn’t have this e dot term. So, what is the effect of adding this proportional  and derivative terms right? We have seen this   again in earlier problems, but it is its good  for us to remind us every now and then. So,   this j s square if it just had a K p without  a K d I know that it is not stable then the   roots will always be on the imaginary axis  as soon as I add a K d I have I introduce   a damping term and by proper choice of this K  d I could choose this system is under damped

over damped critically damped or I can play  around with the response of the system right.   Now K d influences only the s power 1,  term K p influences s power 0 term right,   but then well to have control over the close  loop pole locations I need two things right. So,   the standard thing was I had omega n square  over s square plus 2 zeta omega n s plus omega   n square and this omega n together with zeta  characterise the complete behaviour of the close

loop system right. So, therefore, here both  these terms K p and K d are necessary to have   complete control over the close loop poles. So, in the previous slides we had said well the   derivatives term is in some sense anticipatory  or predictable it can predict what is going to   happen in the future and these systems  we called as non-causal systems moreover   while defining transfer functions we said.  Or we defined a proper transfer function in such a way that the number of poles should be  equal to the number of zeros or the number of   poles should be greater than the number of  zeros where the number of zeros were great,   were greater than the number of poles as in  this case there is one zero and no pole this   were improper transfer functions and I could  not realise or I would not be able to realise   in practice right or I can just cannot just  go to the market or say amazon dot com and say

well I am was looking for a derivative  control that will not happen right.   And amplification of noise when I am looking at  a derivative component here and say I have first   you know like where you have frequency noise  the effect of the derivative could be very   bad in terms of the amplification of the noise  right. So, the derivative term acts on the rate   of the error right and therefore, the output is  highly susceptible to noise if it is changing or a higher frequency and this noises can cancel  can come either through the measurement sensors   or through the reference signal itself. So,  just for practical purposes sometimes it is   good for us to add the derivative control in the  feedback loop if I have no noise sensor right. So,   I can then affect, so I can reduce the effect of  noise which are evaluating through this right. So,   in this case the noisy reference signal gets  filtered before or it gets filtered in the

forward path before encountering a differentiate  it does not the noisy signal does not really   affect or encounter the differentiator  right, but of course, still I have to   take care of the noise which is coming from  y of s that is a bit of a trade-off here,   but just some issues which we have to be careful  of while dealing with these things in practice. So, the point is now well I have this derivative  controller I design nice properties and as I   also told you that cannot buy it in the  market well. So, what do I do? Well can   I make an approximation, so to address both  issues I will tell you why I am addressing   actually both of these issues: amplification  of noise and I can also take care of this non   causality to address both these issues I have an  approximation of a PD controller now right. So,

in such a way that as so I just if you see  here I am just taking K d s which is the actual   derivative term and I am adding a pole here and I  do this s over p just to maintain the DC gain. So,   T d s is causal I have one pole, one zero.  Now and as p goes to infinity T d s goes to   K d s and we recover the original derivative  controller again which is non causal ok.   So, what does this guy do? 1 over s over p plus  one this acts as a low pass filter right as we

saw in that the frequency response well it goes  something like this right and you have some kind   of bandwidth right a cut off frequency as we had  called. So, this multiplicative term acts as a low   pass filter and eliminates high frequency content  before passing through the differentiator right   and usually noise is a high frequency signal  so there. So, if I just add a add a additional   pole here that will take care of the high  frequency signals right and of course,

again as p goes to infinity we have an low pass  filter and we get back a pure differentiator.   So, I have done two things here I have made this  guy to be causal or a realisable transfer function   still comes with its own set of you know it still  not done and what we also saw is that I can place   the poles further away from the origin. So, in  one of the earlier lectures we saw what is the   effect of adding a pole to a transfer function  what is the effect of adding a zero to transfer

function if I add poles to further to the left  then the effect becomes small and small right. So,   I can smartly choose the location of poles such  that the effect is like a derivative controller   it is causal and it also eliminates this the  issues related to amplification of noise right.   Now this brings us to some kind of approximation  of this PID controllers which are in text   referred to as lead and lag compensation. Well just start with a lag compensation which

essentially is an approximation of a proportional  plus integral controller a PI controller well   I know provides perfect tracking for constant  reference inputs and helps in rejecting constant   external disturbances we said this repeatedly will  keep saying this over and over right. Of course,   this is not by itself stable it has a  pole at at the origin and so therefore,   well it is not a stable system and we also saw we  have this integrator wind up property and also in some cases we had seen for higher order plants  that it can actually destabilise the closed loop   system. I add a integrator and I do the math  it says steady state error is 0, but say hold   on you know the system is actually unstable you  cannot apply the final value theorem blindly.   So, now let us say let me say take a condition  where small steady state errors are acceptable   right. In that case a perfect tracking may not be  necessary right if I look at the cricket ball I

do this and it goes to I do this right it goes to  the DRS its okay right even if the you know ball   is hitting the stumps and if the margin  of error is say point 0 one millimetre,   I'm I'm okay with that right it will still be  the umpires call 3 reds or 3 greens and all those   drama which adds up while we are watching  while we are watching cricket these days,   in that case a some small steady state errors are  acceptable right. Now these things leads us to the following approximation of a PI controller. So, we start with the ideal one which is K p   plus K I over s that is K I over K p plus s, but  I just add not a pole at the origin, but very   close to the origin could be as much as 0.01 with  p being very close to 0. Now the design procedure   we will see how close to 0 it should be right.  So, and further well this now looks like a gain K,   a zero, and a pole in such a way that the pole  is very close to the origin and some zero right,

this we will see how to design this right  where K is K p and z is K I over K p right. So,   the approximation of PI which is a lag compensator  what does it do - instead of having a pole at the   origin and see this was the pole at the origin,  a zero on the left half plane. Now we have a pole   and zero both in the left half plane right and  it is a stable controller right z is less than 0,   p is less than 0, it is always stable and this  approximation is called a lag compensator.

Now, we may ask ourselves from when you know  actually you are actually you know playing around   too much with a system right you are teaching us  something and, but then you are approximating now   we will see is the effect of these approximation  disastrous or is this good enough. So, again we will start with the first order plant  I have this PI controller and the static position   error you know all these I do the error as say  well because of this integral action the steady   state error goes to 0. Now consider the same  plant with a lag compensator this was the ideal   one right which we said has very good properties  in addition to some not very good properties too,   now if I do this K s plus z s plus p and I pass  it through my plant I do all the error analysis

and what I get is that the steady state error  is 1 over 1 plus K z over p this p is very small   0.001 or 0.01 and say this you know so based on  these choices I can make this error as close to   0 as possible right. So, this is not equal to 0,  but this is well as close to 0 as possible. So,   that would be the objective right. The steady state error will not be 0   with a lag compensator right. However, what  is in my in my control I can have K I have

z and I have p and I can make this as large  as possible to achieve as smaller errors as   possible. Now what is the effect of adding  the lag compensator on the root locus?   So, let me start with a plant well it just kind  of fairly good looking I have two poles and there   is no zero, so everybody goes to infinity and  just by adding a proportional controller well   I see you know this the red line right. So, the  poles are always at an this complex conjugate poles and then I have a certain steady state  error sorry this I could compute by hand.

Now if add a lag compensator first let’s see what  is the ideal case right the proportional plus   integral controller I do all these things and get  a steady state error to be 0 which theoretically I   learn I have been learning since a very long time  now. Now if I instead of this I do something like   this I still have s plus 0.15 and I have a pole  very very close to the origin that’s like 0.015   right and then the dominant closed loop poles  are at this location and some somewhere here right. And then the steady state error instead  of 0 is now 0.03 which is you know a kind of   fairly acceptable right and if you look at the  root locus it does not really change much. So,   the qualitative behaviour of the system with  respect to gain has not changed much if not   little it will change via very small margin,  but we still be in a very safe zone right.   So, I will start with 0 and 0.05 this is right.  So, what these plots tell us right, so I have a

plot here with the p and a PI. So, and all the  time well we talking of p I we were talking of   perfect tracking right disturbance rejection. So,  all these are steady state behaviour these are all   important add the steady state, now while I am  playing around with a steady state behaviour or   I am trying to improve the steady state behaviour  does it have any bad influence on the transient   behaviour. So, the first plot which is just  adding a proportional controller and comparing it with a PI controller you see that this section  is fairly close enough. So, there is not too much   of compromise on my transient behaviour it will be  very small right. However, now this is the ideal   PI controller now I say well this is actually  not very good and I need to actually have go to   something called as lag compensator which is an  approximation of a PI controller and here I say   well they are more or less they are very they  are very much the same right this show so much

seem that with this plot I cannot really find out  any difference if I zoom in like a hundred times   possibly something would happen here right. So, first thing is the PI controller has a   good effect on the steady state performance  without compromising too much on the transient   behaviour and the PI is close to the lag  compensator and therefore, I can conclude   that the lag compensator if I implemented this  way it improves my steady state performance without compromising too much on the transient  behaviour. That’s what that we will keep in   mind whenever we are doing a steady state error  design for a for a lag compensator design.

Now, having found a causal approximation  for a derivative controller and we would   again like to do something similar as  we did for the PI controller right. So,   under a similar approximation, we will again  K s plus z and s plus p where again K here I   can find what are the constants and z  and so on. Now again this is causal,   this is stable and again this is less susceptible  to high frequency noise right because it is not

a pure derivative term right. So, both the pole  and zero are in the left half plane with a pole   further away from the origin than the zero. Now,  we will really see why this is true right. So,   here it’s so even though both the structures were  the same K s plus z K s plus p here I also had   the same structure right it really depends then on  the choice of the poles and zeros to decide which   one is the lead compensator which one is the lag  compensator and I will shortly tell you that.

But before that let us again analyse what is  the effect of adding a lead compensator on   the root locus. So, what we saw earlier was  adding a derivative component significantly   improved my transient response without possibly  much changing in the steady state response.   So, start with 1 over s square for which I saw  that all the time that my poles how much ever I   change the gain they are on the imaginary axis.  Now adding a proportional derivative control

which is I am just adding zero it just has the  effect, it just pulls the root locus to the left   right. So, the poles for a certain gain which were  here sorry which were at this location have now   becomes somewhere here right approximately  right. So, through this PD control and a   smart choice of K and z, I can place my poles  anywhere on this circle or the circle could be   different for different kind of stuff right. Now look at this thing right. So, this is

desirable right that the root locus experiences  a significant shift to the left and shift to   the left is required because I am interested in  improving the transient performance. Now this PD   controller how does it compare to when I just look  at a lead compensator which is an approximation,   well say I have a say a zero at minus 1 here and  a pole significantly further right, now when I   do this you will only see that there is not much  difference right the green and the blue are fairly

close enough to each other and again with some  little adjustments here I can get my close loop   here we to perform in a certain manner right. So, what we conclude here is that the ideal PD   controller it affects or it improves the transient  performance via this kind of a behaviour that   it pulls the root locus to the left it also  helps in increasing the relative stability,   but this approximation also does more or less same  kind of a job and this is realisable this possibly is not this is never realisable right and you can  say well then what does this pole do right. So,   the only significant difference here is  I have a s plus z, but I have a pole. So,   the reason I had a pole very further away is  that the effect of pole as it goes further   and further to the left it reduces right  as we have seen in the first lecture.   So, I will add a pole to make it a proper  transfer function, but I will keep it far

enough in such a way that it does not really  affect my behaviour of the system right. So,   both compensators now have this structure  s plus z it has a pole, it has a zero,   it has a gain right. So, when z is greater than  p then it is a lag compensator. If I were just to   write down in a very you know very nice way. So,  the lag compensator should have an integral action   I just cannot have a pole at the origin. So, I  place it somewhere very close by and then the zero

would be somewhere here right. So, that the zero  is to the left of the pole for a lag compensation   what did we see for the lead compensation is that  if I add a zero here it pulls the root locus to   the left which is nice which is I want right it  improves the transient response. But to make it   realisable I have to add a pole. So, I add a pole  further to the left which means the effect of this   on the transients will be will be as minimal  as possible right and then of course, when we

will see why these are called lead and lag right.  So, I will skip this discussion when we actually   draw the bode plots of this compensators. So, having had an approximation for both PD and PI   well will there exist what about PID controllers  right. So, this problem is solved by using lead   and lag compensators in cascade to each other. So,  as to approximate a PID control action right.

So, after all these design approximations the lead  and the lag and the PID being a cascade of a lead   and a lag how do we relate this to performance  specifications. So, while we started our time   response analysis we said that the performance  was based on the overshoot it was based on the   rise time, settling time, steady state error and  so on, then we also had an equivalent frequency   domain analysis where we talked of resonance  frequency, we talked of bandwidth, and how are all these related to each other and how are  all these related to the design specifications   and how could we do this via a lead and a lag.  So, before we do that we will just compare the   performance specifications both in the time and  the frequency domain and see if they are actually   related to each other. So, so what we have done so  far is from the description and specification of

the close loop in terms of the overshoot as I said  the rise time, settling time, steady state error   and these are very nice to visualise right. And this actually came across as finding all   these, all these were like second order system  analysis right. So, all these were nice when we   say there are several poles in the system, but  if there is dominant second order pole maybe   all other guys lying further to the left and there  will some zeros here, zeros here. So, this is what detected my behaviour of the closed loop system  right. So, all those analysis could be just made   based on this dominant closed loop systems right. So, however, we did not really talk of talk much   of relative stability noise rejection and this  were nicer to understand in the frequency domain   in terms of what we saw when I actually add a  integral component or a pole in my what was said   the lead compensator it had a good affect two  good affects - one was it made that derivative

controller look a little more realisable it also  had the effect of attenuation of higher frequency   signals which are essentially the noise signals  right. So, and these are in some sense better to   understand in the frequency domain and therefore,  we see sometimes these parameters or the design   specifications are well to loosely speaking  simpler than the time domain. Simpler not in terms   of that the problems which I gave in frequency  domain are simpler than the time domain it will actually turn out to be the reverse that you  know this might need a little more you know trial   and error or some approximations than the  design data domain. So, simplicity comes   from this from one or two parameters I can  actually get lots of information right.   So, before we do that we just find out is there  a correlation between these parameters such as   the rise time overshoot to its, to the frequency  domain parameters which were the resonant peak,

the resonant frequency, bandwidth, the gain  margin, phase margin, and so on. Again all over   analysis for obvious reasons of the dominant pole  behaviour was or we tried to find this correlation   for second order systems right this correlation  holds very nicely when the closed loop systems   has a pair of dominant poles right. And for higher  order systems where there is possibly no concept of this domination poles we may have to do some  better simulations to achieve the results, but for   our analysis purpose we just restrict ourselves  to the dominant poles and that also gives us lots   of rich information. So, starting with a second  order system I know all these formulas now, well   possibly by heart right. So, peak overshoot and  the settling time, the rise time and I have this   error constants K p, K v, K a and so on right. And at the same time I also have if I have a

frequency response like this, this is Bode  diagram of a typical second order transfer   function I will have a resonant peak. So, this  is the resonant peak occurring at some resonant   frequency and these formulas we derived earlier.  It will also have a bandwidth right this one of this is a ugly looking expression, but I will  just quickly tell you how to do it by hand.   So, I start with a second order system which is  omega n square by s square plus twice zeta omega   n s plus omega n square then I do the sinusoidal  version of it the T of j omega is omega n square   over minus omega square omega n square plus 2 j  two zeta omega and then this is should be j omega.   So, I will have another omega n. So, when I define  the bandwidth I look at this thing right. So,

at which the magnitude is about point seven times  the magnitude at a here. So, the magnitude of this   guy Y of j omega this 1 over square root 1 minus  u square whole square plus 4 zeta square u square   where u I had defined earlier it also to be omega  over omega n right. So, first is how do you define   the bandwidth or even the cut off frequency right.  So, this is the frequency at which the magnitude

of the response now in terms of the frequency  response not the time response is three d b   or below right and the bandwidth isn’t defined  as this 0 less than omega less omega b right.   So, how do we find this we just looked at take the  transfer function and evaluate it to 1 over square   root 2 in the absolute scale or in the in the log  scale we say 20 log of T j omega should be minus   3 and I will just keep the computations because  it is just kind of the business very manual right

you can just do it by yourself. And then I can say  that the bandwidth is related to zeta and omega n   via this you know kind of ugly looking expressions  square root inside the square root and so on.   So, I will not ask you to differentiate this or  anything like that, but we will just try to not   even remember this formula only to show that there  exists a relationship between the bandwidth which is essentially a frequency domain concept which  relates directly to omega n and zeta which came   from the time domain specifications right. For  a system to track inputs quickly it must have a   large bandwidth this again comes from here right  what is bandwidth is depending upon omega n and   zeta right. And however, sometimes it will be it  is not desirable from the noise perspective right

because if I have a higher bandwidth as I saw when  I were just having a pure derivative controller it   was an all pass filter and it had the drawback of  not dealing very well with high frequency noise   signals right. So in practice we will actually  look at trade-offs between good and bad right. Now the M r or the resonant peak it depends only  on zeta. So, somewhere here and then we also have   this have the formula for the resonant frequency.  So, in this case well it has an exact correlation   with M p if I just draw M r. So, look at these two  formulas right they are they are kind of nice. So,   M r is directly depending on sorry M p the peak  overshoot in the time domain specifications   is directly depending on zeta nothing else  similarly the M r also has a relation. So,

if I find an M r here with gives me a value I  could correspondingly find a value for M p right.   Now can I do it all the time well let us just  see that right resonant peak only exists for   these frequencies right and therefore, whenever I  look at the correlation between M p and just from   here till here from points point till the it is  this .707 right if you just because of this guy   over here. So, for these guys well I can just  see that you know there is a direct correlation

between M p and M r of course, this is not  defined for zeta equal to 0 right. And then   this is this is really too much of concern  not really because the peak overshoot for   zeta being greater than 1 over square root 2 is  very small right. So, for a given zeta either   the bandwidth or the resonant frequency can  be used to specify omega n via these guys.   Given this guy you know I can compute these  things right and therefore, the bandwidth