Controller Design Basics
- 20Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
What is a key characteristic of a proportional controller?
What is a key characteristic of a proportional controller?
20 questions
- 1
What is a key characteristic of a proportional controller?
- A
It increases steady-state error.
- B
It eliminates steady-state error completely.
- C
It reduces steady-state error but does not eliminate it.
- D
It has no effect on steady-state error.
Correct answer
CIt reduces steady-state error but does not eliminate it.
Explanation
The proportional controller reduces steady-state error, but cannot eliminate it entirely unless the gain is infinite.
- A
- 2
What aspect of system performance does derivative control primarily improve?
- A
Steady-state error
- B
Disturbance rejection
- C
Noise immunity
- D
Transient response and relative stability
Correct answer
DTransient response and relative stability
Explanation
Derivative control improves transient response by adding damping and pulling the root locus to the left, enhancing relative stability.
- A
- 3
Why is a pure derivative controller considered non-causal?
- A
It requires infinite gain.
- B
It has a pole at the origin.
- C
It has more poles than zeros.
- D
It has more zeros than poles, making it improper.
Correct answer
DIt has more zeros than poles, making it improper.
Explanation
A pure derivative controller has a transfer function K_d s, which has one zero and no poles, making it improper and non-causal.
- A
- 4
What is a major practical drawback of derivative control?
- A
It increases steady-state error.
- B
It amplifies high-frequency noise.
- C
It cannot be implemented with operational amplifiers.
- D
It always destabilizes the system.
Correct answer
BIt amplifies high-frequency noise.
Explanation
Derivative control amplifies high-frequency noise because differentiation increases the magnitude of high-frequency signals.
- A
- 5
What is the main benefit of integral control?
- A
It improves transient response speed.
- B
It eliminates steady-state error for constant reference inputs.
- C
It reduces sensitivity to noise.
- D
It increases the damping ratio.
Correct answer
BIt eliminates steady-state error for constant reference inputs.
Explanation
Integral control adds a pole at the origin, increasing the system type to one, which provides perfect tracking of step inputs.
- A
- 6
What is integral wind-up?
- A
The integral term accumulates error during actuator saturation, causing large overshoot.
- B
The steady-state error becomes zero but transient worsens.
- C
The controller output oscillates due to high gain.
- D
The system becomes unstable due to derivative action.
Correct answer
AThe integral term accumulates error during actuator saturation, causing large overshoot.
Explanation
When the actuator saturates, the error continues to accumulate in the integrator, leading to large control inputs and poor transient behavior.
- A
- 7
What is a potential disadvantage of integral control for higher-order plants?
- A
It increases the bandwidth.
- B
It can destabilize the closed-loop system.
- C
It always reduces stability margins.
- D
It eliminates all steady-state errors.
Correct answer
BIt can destabilize the closed-loop system.
Explanation
As shown in the content, adding an integrator to some higher-order plants (e.g., with transfer function 1/(s^2+...)) can make the closed-loop system unstable regardless of gain.
- A
- 8
Besides tracking constant references, what other benefit does integral control provide?
- A
It improves the damping ratio.
- B
It increases the system bandwidth.
- C
It rejects constant disturbance inputs.
- D
It reduces noise amplification.
Correct answer
CIt rejects constant disturbance inputs.
Explanation
Integral control accumulates the error due to constant disturbances and generates a control signal to reject them, as shown in the lecture.
- A
- 9
How is a pure derivative controller approximated to make it causal?
- A
Both adding a pole and a low-pass filter.
- B
By adding a pole far away from the origin.
- C
By adding a zero at the origin.
- D
By using a low-pass filter in series with a differentiator.
Correct answer
ABoth adding a pole and a low-pass filter.
Explanation
The approximation is Td(s)=Kds/p+1s, which adds a pole at −p and acts as a low-pass filter, making the transfer function causal.
- A
- 10
In a lag compensator, where are the pole and zero located relative to each other?
- A
The pole is at the origin and the zero is in the right half-plane.
- B
The pole is to the left of the zero.
- C
Both pole and zero are at the origin.
- D
The zero is to the left of the pole.
Correct answer
DThe zero is to the left of the pole.
Explanation
For a lag compensator, the zero is closer to the origin than the pole (i.e., zero is to the left of the pole), approximating an integral action.
- A
- 11
In a lead compensator, where are the pole and zero located?
- A
The zero is to the left of the pole.
- B
The pole is to the left of the zero.
- C
The zero is at the origin.
- D
Both are at the same location.
Correct answer
BThe pole is to the left of the zero.
Explanation
For a lead compensator, the pole is placed further to the left (larger magnitude) than the zero, so the effect of the pole is minimal while the zero improves transient response.
- A
- 12
What is the effect of a lead compensator on the root locus?
- A
It pulls the root locus to the left.
- B
It has no effect on the root locus.
- C
It adds a pole at the origin.
- D
It pulls the root locus to the right.
Correct answer
AIt pulls the root locus to the left.
Explanation
The zero in the lead compensator pulls the root locus to the left, improving relative stability and transient response.
- A
- 13
How does a lag compensator affect steady-state error compared to a PI controller?
- A
It has no effect on steady-state error.
- B
It makes steady-state error exactly zero.
- C
It increases steady-state error.
- D
It reduces steady-state error to a small, non-zero value.
Correct answer
DIt reduces steady-state error to a small, non-zero value.
Explanation
The lag compensator approximates a PI controller; its steady-state error is 1/(1+Kz/p), which can be made very small but not zero.
- A
- 14
How is a PID controller approximated using lead and lag compensators?
- A
By summing a lead and a lag compensator.
- B
By cascading a lead compensator with a lag compensator.
- C
By using only a lead compensator.
- D
By using only a lag compensator.
Correct answer
BBy cascading a lead compensator with a lag compensator.
Explanation
The PID control action can be approximated by cascading a lead compensator (PD approximation) with a lag compensator (PI approximation).
- A
- 15
What is the definition of bandwidth in the frequency domain?
- A
The frequency where the magnitude is -3 dB (or 1/2).
- B
The frequency where the magnitude is 0 dB.
- C
The frequency range over which the gain is positive.
- D
The frequency where the phase is -90 degrees.
Correct answer
AThe frequency where the magnitude is -3 dB (or 1/2).
Explanation
Bandwidth is defined as the frequency range from 0 to the frequency where the magnitude drops to -3 dB (or 1/2 of the DC gain).
- A
- 16
What does the resonant peak Mr depend on?
- A
The gain of the system.
- B
Only the damping ratio ζ.
- C
Only the natural frequency ωn.
- D
Both damping ratio ζ and natural frequency ωn.
Correct answer
BOnly the damping ratio ζ.
Explanation
For a second-order system, Mr=1/(2ζ1−ζ2) for ζ<0.707, so it depends only on ζ.
- A
- 17
What is the relationship between rise time and bandwidth?
- A
Rise time is proportional to the reciprocal of bandwidth squared.
- B
Larger bandwidth leads to larger rise time.
- C
Larger bandwidth leads to smaller rise time.
- D
Rise time is independent of bandwidth.
Correct answer
CLarger bandwidth leads to smaller rise time.
Explanation
From the content: a larger bandwidth implies a smaller rise time, as seen from the formulas relating tr and ωb.
- A
- 18
For what range of damping ratio ζ does a resonant peak exist in the frequency response?
- A
ζ<0.707
- B
ζ<1
- C
ζ>0.707
- D
ζ=0
Correct answer
Aζ<0.707
Explanation
The resonant peak exists only when ζ<1/2≈0.707; for larger ζ, the magnitude decreases monotonically.
- A
- 19
For a second-order system, how are peak overshoot Mp and resonant peak Mr related?
- A
There is no relation between them.
- B
Mp depends on ζ, Mr depends on ωn.
- C
Both depend only on ζ and are directly correlated.
- D
Mp is always larger than Mr.
Correct answer
CBoth depend only on ζ and are directly correlated.
Explanation
Mp=e−πζ/1−ζ2 and Mr=1/(2ζ1−ζ2); both depend only on ζ, so they are correlated.
- A
- 20
When can the correlation between time-domain and frequency-domain specifications be used for higher-order systems?
- A
When the system is of first order.
- B
When the system has no zeros.
- C
Always, for any higher-order system.
- D
When the system has a pair of dominant closed-loop poles.
Correct answer
DWhen the system has a pair of dominant closed-loop poles.
Explanation
The correlation holds for second-order systems; for higher-order systems, it can be used if the response is dominated by a pair of poles.
- A

Ask anything
We've read this whole study set, so questions about it get the best answers.