Open-System Thermodynamics

Open-System Thermodynamics and Rankine Cycles

Analyzing open-system processes

An open system allows mass to cross its boundary. Common examples include turbines, compressors, pumps, boilers, condensers, and heat exchangers. Analysis usually follows three steps:

  1. Choose a control volume. Draw the boundary around the component or collection of components being analyzed. The location of the boundary determines which heat, work, and mass transfers are included.

  2. Apply conservation of mass and energy. These balances relate the inlet and outlet flows to changes within the control volume.

  3. Apply the second law when needed. If the question is whether a process is possible, determine whether the process is consistent with the entropy balance.

These steps produce symbolic relationships, such as expressions for turbine power or heat transfer. To evaluate those relationships numerically, the thermodynamic states must also be determined. This requires finding properties such as specific enthalpy, specific entropy, and specific volume.

A useful order of operations is to establish the control volume, write the balances, identify justified assumptions, and then determine the properties needed to evaluate the result.

Conservation of mass

The general mass balance for a control volume is

dmCVdt=∑inm˙−∑outm˙.\frac{d m_{\mathrm{CV}}}{d t} = \sum_{\mathrm{in}} \dot{m} - \sum_{\mathrm{out}} \dot{m}.dtdmCV​​=∑in​m˙−∑out​m˙.

At steady state, mass does not accumulate inside the control volume, so

∑inm˙=∑outm˙.\sum_{\mathrm{in}} \dot{m} = \sum_{\mathrm{out}} \dot{m}.∑in​m˙=∑out​m˙.

For one inlet and one outlet, this simplifies to

m˙in=m˙out.\dot{m}_{\mathrm{in}}=\dot{m}_{\mathrm{out}}.m˙in​=m˙out​.

This equality is especially useful when several steady-flow components are connected in series: if each has one inlet and one outlet and there are no branches or leaks, the same mass flow rate passes through each component.

First-law energy analysis

A common steady-flow energy balance, with heat transfer into the control volume and work output from it taken as positive, is

Q˙−W˙=∑outm˙(h+V22+gz)−∑inm˙(h+V22+gz).\dot{Q}-\dot{W} = \sum_{\mathrm{out}}\dot{m} \left( h+\frac{V^2}{2}+gz \right) - \sum_{\mathrm{in}}\dot{m} \left( h+\frac{V^2}{2}+gz \right).Q˙​−W˙=∑out​m˙(h+2V2​+gz)−∑in​m˙(h+2V2​+gz).

Here, hhh is specific enthalpy, VVV is flow speed, ggg is gravitational acceleration, and zzz is elevation. In imperial-unit calculations, kinetic- and potential-energy terms may require the conversion factor gcg_cgc​ to maintain consistent units.

Common simplifying assumptions include:

  • Steady state

  • One inlet and one outlet

  • Negligible changes in kinetic and potential energy

  • A process that is either primarily a work-producing or work-consuming process, or primarily a heat-transfer process

  • Adiabatic operation for components such as turbines and pumps, when justified

  • Negligible pressure and heat losses in connecting pipes or ducts

These are common assumptions, not automatic rules. They should be used only when they are appropriate to the problem. For example, neglecting pipe friction and heat loss makes it possible to treat a component’s outlet state as the next component’s inlet state. If line losses are included, pressure and temperature may change between components, so the state must be determined again at the new conditions. Cycle analyses often neglect these losses because they are small relative to the major energy transfers being studied.

Second-law analysis and process feasibility

The second law can be used to test whether a process is physically possible. At steady state, the entropy balance for a control volume can be written as

S˙gen=∑outm˙s−∑inm˙s−∑jQ˙jTj,\dot{S}_{\mathrm{gen}} = \sum_{\mathrm{out}}\dot{m}s - \sum_{\mathrm{in}}\dot{m}s - \sum_j\frac{\dot{Q}_j}{T_j},S˙gen​=∑out​m˙s−∑in​m˙s−∑j​Tj​Q˙​j​​,

where sss is specific entropy, S˙gen\dot{S}_{\mathrm{gen}}S˙gen​ is the entropy-generation rate, and Q˙j\dot{Q}_jQ˙​j​ is heat transfer into the control volume at boundary temperature TjT_jTj​.

The second law requires

S˙gen≥0.\dot{S}_{\mathrm{gen}}\geq 0.S˙gen​≥0.
  • A process with S˙gen=0\dot{S}_{\mathrm{gen}}=0S˙gen​=0 is reversible in the idealized thermodynamic sense.

  • A process with S˙gen>0\dot{S}_{\mathrm{gen}}>0S˙gen​>0 is irreversible.

  • A result with S˙gen<0\dot{S}_{\mathrm{gen}}<0S˙gen​<0 indicates that the proposed process or assumptions are not physically possible.

For a heat exchanger, one useful strategy is to include the entire exchanger within the control volume. If the exchanger is adiabatic with respect to its surroundings, there is no external heat-transfer term in the entropy balance. The mass-flow and state information for the exchanger streams can then be used to evaluate entropy generation.


Determining thermodynamic properties

Before finding enthalpy or entropy, the working fluid must be identified. Two broad cases are common:

  1. A substance that undergoes phase change, such as water or a refrigerant

  2. An ideal gas, such as air modeled as an ideal gas

Water and other phase-changing fluids

For water and similar substances, property selection depends on the phase or region of the substance:

  • Subcooled (compressed) liquid: liquid below its saturation temperature at the given pressure

  • Two-phase mixture: liquid and vapor coexist beneath the saturation dome

  • Superheated vapor: vapor above its saturation temperature at the given pressure

Two-phase and superheated-vapor tables are commonly used to determine properties. The correct table depends on the state being analyzed.

Subcooled-liquid approximations

A subcooled liquid is often treated as incompressible. If its specific heat is approximately constant, its enthalpy change is

Δh≈cp(T2−T1).\Delta h \approx c_p(T_2-T_1).Δh≈cp​(T2​−T1​).

For an ideal pump moving an incompressible liquid, the enthalpy change can also be estimated from the pressure rise:

Δh≈v Δp,\Delta h \approx v\,\Delta p,Δh≈vΔp,

where vvv is the liquid’s specific volume. Because liquid specific volume changes little between pump inlet and outlet, it is often approximated as constant.

For a subcooled liquid with approximately constant specific heat, the entropy change is

Δs≈cpln⁡(T2T1).\Delta s \approx c_p\ln\left(\frac{T_2}{T_1}\right).Δs≈cp​ln(T1​T2​​).

Temperatures in logarithmic property relations must be expressed on an absolute scale.

Ideal gases

For an ideal gas, enthalpy depends primarily on temperature. With constant specific heat,

Δh=cp(T2−T1).\Delta h=c_p(T_2-T_1).Δh=cp​(T2​−T1​).

If specific heats vary appreciably with temperature, property tables or variable-specific-heat relations are more accurate.

For ideal-gas entropy, the temperature and pressure contributions can be combined as

s2−s1=s∘(T2)−s∘(T1)−Rln⁡(p2p1),s_2-s_1 = s^{\circ}(T_2)-s^{\circ}(T_1) - R\ln\left(\frac{p_2}{p_1}\right),s2​−s1​=s∘(T2​)−s∘(T1​)−Rln(p1​p2​​),

where s∘(T)s^{\circ}(T)s∘(T) is a tabulated ideal-gas entropy function and RRR is the specific gas constant. The specific gas constant is the universal gas constant divided by the gas’s molar mass.

If specific heats are assumed constant, the same entropy change can be calculated using temperature and pressure ratios:

Δs=cpln⁡(T2T1)−Rln⁡(p2p1).\Delta s = c_p\ln\left(\frac{T_2}{T_1}\right) - R\ln\left(\frac{p_2}{p_1}\right).Δs=cp​ln(T1​T2​​)−Rln(p1​p2​​).

It can instead be expressed using temperature and specific-volume ratios:

Δs=cvln⁡(T2T1)+Rln⁡(v2v1).\Delta s = c_v\ln\left(\frac{T_2}{T_1}\right) + R\ln\left(\frac{v_2}{v_1}\right).Δs=cv​ln(T1​T2​​)+Rln(v1​v2​​).

The pressure-ratio form is often convenient for open-system devices because inlet and outlet pressures are commonly known. The specific-volume-ratio form is often convenient for closed systems, such as a piston-cylinder device, where volume ratios are known. Both constant-specific-heat forms are approximations; the tabulated s∘(T)s^{\circ}(T)s∘(T) method accounts more accurately for varying specific heat.


Isentropic ideal-gas relations

An isentropic process has no change in entropy. In ideal-device analysis, an adiabatic, internally reversible turbine or compressor is often modeled as isentropic. The following ideal-gas relations require both an ideal gas and constant specific heats.

The specific-heat ratio is

k=cpcv,k=\frac{c_p}{c_v},k=cv​cp​​,

and is greater than 111. For air, a commonly used approximate value is k≈1.4k\approx 1.4k≈1.4.

The isentropic temperature and pressure relation is

T2sT1=(p2p1)(k−1)/k,\frac{T_{2s}}{T_1} = \left(\frac{p_2}{p_1}\right)^{(k-1)/k},T1​T2s​​=(p1​p2​​)(k−1)/k,

where state 2s2s2s denotes the ideal isentropic outlet state. A temperature and volume relation is

T2sT1=(v1v2s)k−1,\frac{T_{2s}}{T_1} = \left(\frac{v_1}{v_{2s}}\right)^{k-1},T1​T2s​​=(v2s​v1​​)k−1,

and the pressure and volume relation is

p2p1=(v1v2s)k.\frac{p_2}{p_1} = \left(\frac{v_1}{v_{2s}}\right)^k.p1​p2​​=(v2s​v1​​)k.

These equations follow from setting the ideal-gas entropy change to zero while assuming constant specific heats. They are useful for finding an ideal outlet temperature when a pressure ratio is known, such as in an ideal compressor or turbine.

For a gas with variable specific heats, these constant-kkk equations should not be used; property tables or variable-specific-heat methods are needed instead.


Example: Ideal air compressor

Consider steady compression of air from T1=300 KT_1=300\ \mathrm{K}T1​=300 K and p1=100 kPap_1=100\ \mathrm{kPa}p1​=100 kPa to p2=800 kPap_2=800\ \mathrm{kPa}p2​=800 kPa. Assume the compressor is adiabatic, has one inlet and one outlet, has negligible kinetic- and potential-energy changes, and operates isentropically. With constant specific heats and k=1.4k=1.4k=1.4, the outlet temperature is

T2s=T1(p2p1)(k−1)/k≈543 K.T_{2s} = T_1 \left(\frac{p_2}{p_1}\right)^{(k-1)/k} \approx 543\ \mathrm{K}.T2s​=T1​(p1​p2​​)(k−1)/k≈543 K.

For an adiabatic steady-flow compressor, the work output using the convention that work out is positive is

W˙m˙=h1−h2.\frac{\dot{W}}{\dot{m}}=h_1-h_2.m˙W˙​=h1​−h2​.

Using h2−h1=cp(T2−T1)h_2-h_1=c_p(T_2-T_1)h2​−h1​=cp​(T2​−T1​) and cp≈1 kJ/(kg⋅K)c_p\approx 1\ \mathrm{kJ/(kg\cdot K)}cp​≈1 kJ/(kg⋅K) for air gives

W˙m˙=cp(T1−T2s)≈−243 kJ/kg.\frac{\dot{W}}{\dot{m}} = c_p(T_1-T_{2s}) \approx -243\ \mathrm{kJ/kg}.m˙W˙​=cp​(T1​−T2s​)≈−243 kJ/kg.

The negative sign means the compressor consumes work. The specific work input is therefore approximately 243 kJ/kg243\ \mathrm{kJ/kg}243 kJ/kg. This is the ideal compressor requirement; a real compressor generally requires more work. Absolute temperature is essential when applying the isentropic temperature-ratio equation.


Rankine cycles and vapor power systems

A Rankine cycle is a sequence of open-system processes that converts heat into net mechanical work while circulating a phase-changing working fluid. Water is common, but other fluids, including refrigerants, can also be used. The essential feature is that the working fluid passes between liquid and vapor states, represented by a vapor dome on a temperature–entropy diagram.

The basic Rankine cycle consists of four components in sequence:

  1. Turbine: high-pressure vapor expands and produces shaft work.

  2. Condenser: low-pressure vapor rejects heat and becomes liquid.

  3. Pump: liquid pressure is raised so it can return to the boiler.

  4. Boiler: heat is added to convert the high-pressure liquid into vapor.

The turbine is the cycle’s principal source of power. The condenser and pump return the fluid to conditions suitable for another pass through the boiler and turbine.

Why the fluid is condensed before pumping

Compressing vapor to high pressure requires substantially more work than pumping liquid to the same pressure. The cycle therefore condenses the turbine exhaust before raising its pressure. This makes the pump’s work small compared with the turbine’s work and gives the Rankine cycle a low back work ratio.

The condenser must reject heat to a sink, such as cooling water or the surrounding environment. Some heat must be rejected by a cyclic heat engine; not all of the input heat can be converted into work.

Heat sources and power-plant context

The Rankine-cycle analysis is largely independent of how heat is supplied or how the turbine’s shaft work is converted into electricity. Heat can come from:

  • Burning coal or natural gas

  • A nuclear reaction

  • Biomass combustion

  • Geothermal sources

  • Concentrated solar heat

In each case, the heat source supplies energy to the working fluid, which then expands through a turbine. An electrical generator can convert the turbine’s rotating shaft work into electrical power. The method used to supply heat, cool the working fluid, or generate electricity is outside the basic four-component cycle analysis unless it is explicitly included in the control volume.

The overall energy conversion in a fossil-fuel plant can be described as

chemical energy→heat→working-fluid enthalpy→shaft work→electrical energy.\text{chemical energy} \rightarrow \text{heat} \rightarrow \text{working-fluid enthalpy} \rightarrow \text{shaft work} \rightarrow \text{electrical energy}.chemical energy→heat→working-fluid enthalpy→shaft work→electrical energy.

Nuclear, geothermal, and solar-thermal plants supply heat by different means, but the Rankine cycle performs the conversion from heat to turbine work in a similar way.


Rankine-cycle states and temperature–entropy diagram

A common state numbering is:

  • State 1: turbine inlet and boiler outlet

  • State 2: turbine outlet and condenser inlet

  • State 3: condenser outlet and pump inlet

  • State 4: pump outlet and boiler inlet

The processes are therefore 1→21\to21→2 through the turbine, 2→32\to32→3 through the condenser, 3→43\to43→4 through the pump, and 4→14\to14→1 through the boiler.

A temperature–entropy diagram shows the liquid–vapor region beneath the saturation dome and the four approximate cycle processes.

  • Boiler, 4→14\to14→1: heat addition raises the fluid’s enthalpy and converts high-pressure liquid into vapor. The turbine inlet may be saturated vapor or superheated vapor.

  • Turbine, 1→21\to21→2: expansion reduces pressure and enthalpy while producing work. An ideal isentropic turbine is shown as a vertical line on a temperature–entropy diagram.

  • Condenser, 2→32\to32→3: heat rejection condenses the turbine exhaust. The outlet is ideally liquid, avoiding vapor at the pump inlet.

  • Pump, 3→43\to43→4: work input raises the pressure of the liquid. An ideal pump is approximately isentropic.

For turbine durability, it is often desirable to keep water droplets from forming during expansion. Liquid droplets can strike turbine blades and cause damage. Superheating the turbine inlet vapor can help keep the turbine exhaust from becoming too wet, while the condenser is designed to produce liquid for the pump.

Heat and work arrows on a cycle diagram can also help keep track of signs:

  • Boiler heat input is positive.

  • Condenser heat rejection is negative.

  • Turbine work output is positive.

  • Pump work input is negative when work output is the positive convention.


First-law equations for Rankine-cycle components

A common set of assumptions for component analysis includes steady state, one inlet and one outlet, negligible kinetic- and potential-energy changes, and negligible heat or pressure loss in connecting lines. A turbine or pump is often modeled as adiabatic; a boiler or condenser is often modeled as passive, meaning that it has no shaft work.

Using heat transfer into the control volume and work output from it as positive:

Turbine

For an adiabatic turbine,

W˙turbine=m˙(h1−h2).\dot{W}_{\mathrm{turbine}} = \dot{m}(h_1-h_2).W˙turbine​=m˙(h1​−h2​).

The turbine is expected to produce positive work because the fluid’s enthalpy falls during expansion.

Pump

For an adiabatic pump,

W˙pump=m˙(h3−h4).\dot{W}_{\mathrm{pump}} = \dot{m}(h_3-h_4).W˙pump​=m˙(h3​−h4​).

The pump’s work is negative under the work-output-positive convention because enthalpy increases across the pump. Its positive work input magnitude is

∣W˙pump∣=m˙(h4−h3).\left|\dot{W}_{\mathrm{pump}}\right| = \dot{m}(h_4-h_3).​W˙pump​​=m˙(h4​−h3​).

For an ideal liquid pump, the enthalpy rise may be estimated with

h4−h3≈v3(p4−p3).h_4-h_3\approx v_3(p_4-p_3).h4​−h3​≈v3​(p4​−p3​).

Condenser

For a passive condenser with negligible changes in kinetic and potential energy,

Q˙condenser=m˙(h3−h2).\dot{Q}_{\mathrm{condenser}} = \dot{m}(h_3-h_2).Q˙​condenser​=m˙(h3​−h2​).

This heat transfer is negative because the working fluid rejects heat.

Boiler

For a passive boiler,

Q˙boiler=m˙(h1−h4).\dot{Q}_{\mathrm{boiler}} = \dot{m}(h_1-h_4).Q˙​boiler​=m˙(h1​−h4​).

This heat transfer is positive because heat is added to the working fluid.

These equations depend on their assumptions. If heat loss, friction, kinetic-energy changes, or other effects are significant, the relevant terms must remain in the balance rather than being neglected.


Thermal efficiency

The purpose of a Rankine cycle is to produce net work from heat input. Its thermal efficiency is

ηth=W˙netQ˙in.\eta_{\mathrm{th}} = \frac{\dot{W}_{\mathrm{net}}}{\dot{Q}_{\mathrm{in}}}.ηth​=Q˙​in​W˙net​​.

For a cycle with one turbine and one pump,

W˙net=W˙turbine+W˙pump,\dot{W}_{\mathrm{net}} = \dot{W}_{\mathrm{turbine}} + \dot{W}_{\mathrm{pump}},W˙net​=W˙turbine​+W˙pump​,

where pump work is negative under the work-output-positive convention. Heat input is the boiler heat transfer; it is not the net heat transfer over the whole cycle.

If the same mass flow rate passes through all four components, it cancels from the efficiency expression. The specific enthalpy form is

ηth=(h1−h2)+(h3−h4)h1−h4.\eta_{\mathrm{th}} = \frac{(h_1-h_2)+(h_3-h_4)}{h_1-h_4}.ηth​=h1​−h4​(h1​−h2​)+(h3​−h4​)​.

Equivalently, since h4−h3h_4-h_3h4​−h3​ is the positive pump work input per unit mass,

ηth=(h1−h2)−(h4−h3)h1−h4.\eta_{\mathrm{th}} = \frac{(h_1-h_2)-(h_4-h_3)}{h_1-h_4}.ηth​=h1​−h4​(h1​−h2​)−(h4​−h3​)​.

The sign convention should be applied consistently: the turbine contribution is positive, and the pump contribution is negative in the net-work sum. The cycle efficiency indicates what fraction of boiler heat input becomes net mechanical work. It is less than 100%100\%100% because heat must be rejected and because real systems have irreversibilities.

A sample cycle calculation in the source obtains an efficiency of 55.3%55.3\%55.3% from its particular state enthalpies. That value is an example for those states, not a universal Rankine-cycle efficiency. Efficiency can be compared with the Carnot limit for the relevant heat-source and heat-sink temperatures to assess how closely a cycle approaches the maximum possible efficiency.


Back work ratio

The back work ratio measures the fraction of turbine output required to drive the pump:

BWR=∣W˙pump∣W˙turbine.\mathrm{BWR} = \frac{\left|\dot{W}_{\mathrm{pump}}\right|} {\dot{W}_{\mathrm{turbine}}}.BWR=W˙turbine​∣W˙pump​∣​.

For a steady cycle with one inlet and one outlet per component, the common mass flow rate cancels, giving

BWR=h4−h3h1−h2.\mathrm{BWR} = \frac{h_4-h_3}{h_1-h_2}.BWR=h1​−h2​h4​−h3​​.

A low back work ratio means that only a small portion of the turbine’s output is needed to run the pump. This is a major advantage of condensing the vapor before pumping: raising the pressure of liquid requires much less work than compressing vapor.

In the example described, the turbine produces about 1788.9 kJ/kg1788.9\ \mathrm{kJ/kg}1788.9 kJ/kg of specific work and the pump requires about 7.6 kJ/kg7.6\ \mathrm{kJ/kg}7.6 kJ/kg. The resulting back work ratio is approximately

BWR≈7.61788.9≈0.0043,\mathrm{BWR}\approx\frac{7.6}{1788.9}\approx 0.0043,BWR≈1788.97.6​≈0.0043,

or about 0.43%0.43\%0.43%. A low back work ratio is beneficial, but it is distinct from thermal efficiency: thermal efficiency measures how much input heat becomes net work, whereas the back work ratio measures how much turbine output is consumed by the pump.