When analyzing an open-system process, which sequence best describes the main analytical steps?
When analyzing an open-system process, which sequence best describes the main analytical steps?
73 questions
- 1
When analyzing an open-system process, which sequence best describes the main analytical steps?
- A
Calculate the heat transfer, neglect mass conservation, and use entropy generation to find the outlet pressure
- B
Define the control volume, apply mass conservation, apply energy conservation, and assess entropy generation if feasibility is in question
- C
Determine the fluid, calculate its entropy, define the control volume, and then apply mass conservation
- D
Apply energy conservation, assume the process is possible, determine the fluid, and then select a control volume
Correct answer
BDefine the control volume, apply mass conservation, apply energy conservation, and assess entropy generation if feasibility is in question
Explanation
Open-system analysis begins by selecting a control volume, then applies mass and energy conservation. A second-law analysis is also needed when determining whether a process is possible.
- A
- 2
For a steady-flow device with one inlet and one outlet, what does mass conservation imply?
- A
The inlet and outlet mass flow rates are equal
- B
The outlet mass flow rate must be zero
- C
The inlet density must equal the outlet density
- D
The inlet and outlet specific volumes are equal
Correct answer
AThe inlet and outlet mass flow rates are equal
Explanation
At steady state, mass does not accumulate within the control volume. With one inlet and one outlet, the mass flow rates must therefore be equal.
- A
- 3
Why should common assumptions in open-system problems not be applied automatically to every problem?
- A
They are valid only for devices with more than one inlet and outlet
- B
They apply only when the working fluid is water rather than an ideal gas
- C
They are useful simplifications, but a problem may provide conditions that require relaxing them
- D
They replace the conservation equations whenever a process is steady
Correct answer
CThey are useful simplifications, but a problem may provide conditions that require relaxing them
Explanation
Steady state, one inlet and outlet, and negligible energy changes are common assumptions, not universal rules. A problem may require analyzing effects that those assumptions would neglect.
- A
- 4
In the imperial-unit first-law expression described in the material, why is kinetic or potential energy divided by gc?
- A
To ensure that the inlet and outlet pressures are equal
- B
To account for heat lost from the control volume
- C
To convert the mass flow rate into a volumetric flow rate
- D
To make the kinetic- and potential-energy terms consistent with the imperial-unit energy units
Correct answer
DTo make the kinetic- and potential-energy terms consistent with the imperial-unit energy units
Explanation
In the stated imperial-unit formulation, gc is included in the kinetic- and potential-energy terms to make the units consistent.
- A
- 5
Which simplifying assumptions are often made about kinetic and potential energy changes in device analyses?
- A
Potential energy is neglected, but kinetic energy must always be retained
- B
Both changes are set equal to the enthalpy change in every device
- C
Kinetic energy is neglected, but potential energy must always be retained
- D
Both changes are neglected when they are small compared with the other energy terms
Correct answer
DBoth changes are neglected when they are small compared with the other energy terms
Explanation
The material describes neglecting both kinetic- and potential-energy changes as common assumptions when they are small relative to the major energy terms.
- A
- 6
If a process is treated as either adiabatic or passive, what is the purpose of that assumption?
- A
It ensures that the process is isentropic regardless of friction
- B
It guarantees that the inlet and outlet enthalpies are equal
- C
It establishes that the mass flow rate changes across the device
- D
It identifies whether heat transfer or power is the relevant interaction and allows the other to be omitted
Correct answer
DIt identifies whether heat transfer or power is the relevant interaction and allows the other to be omitted
Explanation
A process may be simplified by treating it as adiabatic or passive, depending on whether power or heat transfer is the main interaction being analyzed.
- A
- 7
What is a likely consequence of including friction losses in a pipe between two cycle components?
- A
The downstream state remains unchanged because friction affects only velocity
- B
The fluid necessarily returns to its original entropy
- C
The mass flow rate must become zero at the downstream component
- D
The downstream pressure changes, so the downstream state must be evaluated at that pressure
Correct answer
DThe downstream pressure changes, so the downstream state must be evaluated at that pressure
Explanation
Friction losses cause pressure to drop along a pipe. The downstream component therefore receives the fluid at a different pressure, requiring the state to be fixed again.
- A
- 8
Why are heat losses in connecting lines often neglected in cycle analyses?
- A
Neglecting them makes every process in the cycle isentropic
- B
Heat cannot cross the boundary of a pipe in a steady-flow process
- C
Heat losses always cancel exactly with friction losses
- D
They are often assumed small compared with the principal energy transfers being calculated
Correct answer
DThey are often assumed small compared with the principal energy transfers being calculated
Explanation
Cycle analyses often neglect line friction and heat loss when those effects are small compared with the major energy transfers.
- A
- 9
When analyzing the second law for a process, what quantity is used to assess whether the process is possible?
- A
The enthalpy-generation rate, which must equal the mass flow rate
- B
The entropy-generation rate, which must be nonnegative
- C
The heat-transfer rate, which must always be zero
- D
The pressure-change rate, which must be positive
Correct answer
BThe entropy-generation rate, which must be nonnegative
Explanation
The second-law analysis examines entropy generation. A process cannot have negative entropy generation; the material describes positive generation as the condition for a process to proceed.
- A
- 10
Why can analyzing an entire heat exchanger as one control volume simplify a second-law calculation?
- A
The entire exchanger can be treated as having no inlet or outlet streams
- B
Combining the exchanger forces the entropy of each stream to remain constant
- C
The overall exchanger can often be treated as adiabatic, leaving entropy-flow terms associated with the streams
- D
The overall exchanger must have zero entropy generation
Correct answer
CThe overall exchanger can often be treated as adiabatic, leaving entropy-flow terms associated with the streams
Explanation
Considering the whole heat exchanger can allow it to be treated as adiabatic with respect to its surroundings. The analysis can then focus on the entropy carried by the inlet and outlet streams and on entropy generation.
- A
- 11
When fixing thermodynamic states, what should be identified before selecting property data or equations?
- A
The number of power plants using the same fluid
- B
The working fluid and the type of state or process it undergoes
- C
The electrical generator connected to the device
- D
The fuel used to heat the fluid, regardless of the control volume
Correct answer
BThe working fluid and the type of state or process it undergoes
Explanation
The appropriate method for finding properties depends on the fluid and, for a phase-changing fluid, its phase.
- A
- 12
A refrigerant in a vapor-power or refrigeration process is treated like water in property analysis when it undergoes which behavior?
- A
Repeated condensation and evaporation between liquid and vapor states
- B
Only pressure changes while remaining a permanent ideal gas
- C
A constant-volume process without a phase transition
- D
A chemical reaction that changes its molecular composition
Correct answer
ARepeated condensation and evaporation between liquid and vapor states
Explanation
The relevant similarity is that the working fluid undergoes phase changes, such as evaporation and condensation.
- A
- 13
For a phase-changing fluid, which classification helps determine how to find its properties?
- A
Whether its mass flow rate is increasing, decreasing, or constant
- B
Whether it is a subcooled liquid, a two-phase mixture, or a superheated vapor
- C
Whether it is moving upward, downward, or horizontally
- D
Whether it is in a boiler, turbine, or generator
Correct answer
BWhether it is a subcooled liquid, a two-phase mixture, or a superheated vapor
Explanation
For water or a similar phase-changing fluid, the state is identified as subcooled liquid, two-phase mixture, or superheated vapor to select the proper property method.
- A
- 14
Which property resources are appropriate for a two-phase mixture or a superheated vapor?
- A
Only incompressible-liquid equations for both states
- B
Two-phase tables for a mixture and superheated-vapor tables for a superheated state
- C
Only ideal-gas tables for both states
- D
Constant-specific-heat equations without identifying the fluid
Correct answer
BTwo-phase tables for a mixture and superheated-vapor tables for a superheated state
Explanation
The material identifies two-phase tables and superheated-vapor tables as property resources for those respective states.
- A
- 15
For a subcooled liquid treated as incompressible, how can its enthalpy change be approximated?
- A
Δh=TΔs for every process
- B
Δh=cpΔT
- C
Δh=cvΔp
- D
Δh=vΔs
Correct answer
BΔh=cpΔT
Explanation
For an incompressible subcooled liquid, the enthalpy change is approximated by the constant-pressure specific heat multiplied by the temperature change.
- A
- 16
For an ideal pump treated as isentropic, what approximation relates its enthalpy change to its pressure change?
- A
Δh≈cpΔp, using the temperature change
- B
Δh≈pΔv, using a large specific-volume change
- C
Δh=0, because an isentropic process has no enthalpy change
- D
Δh≈vΔp, using the nearly unchanged specific volume
Correct answer
DΔh≈vΔp, using the nearly unchanged specific volume
Explanation
For an ideal pump, the enthalpy change is approximated as specific volume times pressure change. Liquid specific volume changes little across the pump.
- A
- 17
For an ideal gas with constant specific heat, how is its enthalpy change commonly calculated?
- A
Δh=vΔs
- B
Δh=cpΔT
- C
Δh=RΔp
- D
Δh=cvΔp
Correct answer
BΔh=cpΔT
Explanation
For an ideal gas, enthalpy depends on temperature; with constant specific heat, the change is cpΔT.
- A
- 18
What does an isentropic ideal pump or turbine imply about the specific entropy change?
- A
The specific entropy change is zero
- B
The specific entropy change must be positive
- C
The specific entropy change equals the pressure change
- D
The specific entropy change equals the enthalpy change
Correct answer
AThe specific entropy change is zero
Explanation
Isentropic means constant specific entropy, so the entropy change across the ideal pump or turbine is zero.
- A
- 19
For a subcooled liquid, which expression estimates the specific entropy change between two temperatures?
- A
Δs=v(p2−p1)
- B
Δs=Rln(p2/p1)
- C
Δs=cpln(T2/T1)
- D
Δs=cp(T2−T1)
Correct answer
CΔs=cpln(T2/T1)
Explanation
For a subcooled liquid, the material gives the approximation Δs=cpln(T2/T1).
- A
- 20
For an ideal gas with variable specific heat, how can the temperature contribution to entropy change be obtained?
- A
By treating the gas as an incompressible liquid
- B
From the pressure ratio alone without temperature information
- C
By setting the temperature contribution equal to zero
- D
From ideal-gas property tables using the tabulated standard-state entropy function
Correct answer
DFrom ideal-gas property tables using the tabulated standard-state entropy function
Explanation
For variable specific heat, the temperature-dependent ideal-gas entropy term can be obtained from tables, such as the standard-state entropy function described for air.
- A
- 21
Which expression accounts for the pressure contribution to an ideal-gas entropy change?
- A
cp(p2−p1)
- B
Rln(T2/T1)
- C
vln(T2/T1)
- D
−Rln(p2/p1)
Correct answer
D−Rln(p2/p1)
Explanation
The pressure contribution to ideal-gas entropy change is −Rln(p2/p1), where R is the specific gas constant.
- A
- 22
What is the main trade-off between ideal-gas entropy methods using variable and constant specific heats?
- A
Variable-specific-heat methods require no state information; constant-specific-heat methods require a pressure table
- B
Both methods are equally accurate and require no assumptions
- C
Constant-specific-heat formulas are more accurate because they avoid all approximations
- D
Variable-specific-heat methods use tables and are more accurate; constant-specific-heat formulas are less accurate
Correct answer
DVariable-specific-heat methods use tables and are more accurate; constant-specific-heat formulas are less accurate
Explanation
The table-based method accounts for variable specific heat and is more accurate. The compact constant-specific-heat formulas require the assumption that specific heat is constant.
- A
- 23
When is it appropriate to use the ideal-gas isentropic temperature-pressure and temperature-volume relations?
- A
For any process in which the pressure remains constant
- B
For any fluid undergoing a steady process, regardless of entropy change
- C
For an ideal gas undergoing an isentropic process with constant specific heats
- D
For a subcooled liquid undergoing a pressure increase
Correct answer
CFor an ideal gas undergoing an isentropic process with constant specific heats
Explanation
These relations are restricted to ideal-gas isentropic processes and, in the forms presented, also assume constant specific heats.
- A
- 24
In the ideal-gas isentropic relations, what does the specific heat ratio k represent?
- A
k=R/cp, a ratio equal to one
- B
k=p/v, a ratio that depends only on pressure
- C
k=cp/cv, a ratio greater than one
- D
k=cv/cp, a ratio greater than one
Correct answer
Ck=cp/cv, a ratio greater than one
Explanation
The specific heat ratio is k=cp/cv. Since cp is greater than cv, k is greater than one.
- A
- 25
For air, what approximate value of k is used in the material's ideal-gas example?
- A
1.0
- B
0.7
- C
2.4
- D
1.4
Correct answer
D1.4
Explanation
The material uses approximately k=1.4 for air.
- A
- 26
For an ideal gas with constant specific heats undergoing an isentropic process, how is the temperature ratio related to the pressure ratio?
- A
T2/T1=(p2/p1)k
- B
T2/T1=(p2/p1)(k−1)/k
- C
T2/T1=(p1/p2)(k−1)/k
- D
T2/T1=(p2/p1)1−k
Correct answer
BT2/T1=(p2/p1)(k−1)/k
Explanation
The isentropic ideal-gas relation is T2/T1=(p2/p1)(k−1)/k.
- A
- 27
For an ideal gas with constant specific heats undergoing an isentropic process, which relation connects temperature and specific volume?
- A
T2/T1=v1−v2
- B
T2/T1=(v2/v1)k−1
- C
T2/T1=(v1/v2)k
- D
T2/T1=(v1/v2)k−1
Correct answer
DT2/T1=(v1/v2)k−1
Explanation
The isentropic temperature-specific-volume relation is T2/T1=(v1/v2)k−1.
- A
- 28
Which pressure-volume relation applies to an ideal gas with constant specific heats in an isentropic process?
- A
p2/p1=(v1/v2)k−1
- B
p2/p1=v1−v2
- C
p2/p1=(v2/v1)k
- D
p2/p1=(v1/v2)k
Correct answer
Dp2/p1=(v1/v2)k
Explanation
The isentropic pressure-volume relation is p2/p1=(v1/v2)k.
- A
- 29
Why is a pressure ratio often more useful than a specific-volume ratio when analyzing an open-system compressor?
- A
The volume ratio cannot be used in any ideal-gas relation
- B
The pressure ratio is more likely to be known for an open-system device
- C
Pressure ratios are required only when specific heats vary
- D
An open-system compressor always has constant specific volume
Correct answer
BThe pressure ratio is more likely to be known for an open-system device
Explanation
In open systems, the pressure ratio is often known or specified, making the pressure-based relation convenient. A volume ratio is often more accessible in a closed piston system.
- A
- 30
Why might a closed piston-cylinder system use a volume ratio in an isentropic ideal-gas analysis?
- A
Closed systems cannot have pressure changes
- B
Piston motion often makes the volume ratio directly available
- C
A volume ratio eliminates the need to assume constant specific heats
- D
The temperature ratio is undefined in a closed system
Correct answer
BPiston motion often makes the volume ratio directly available
Explanation
In a closed system with a moving piston, the volumes at two states may be known, so the volume-based isentropic relation can be used.
- A
- 31
What assumption is needed before using the presented isentropic ideal-gas relations containing cp, cv, or k?
- A
The specific heats are constant
- B
The process is passive
- C
The gas is incompressible
- D
The pressure is constant
Correct answer
AThe specific heats are constant
Explanation
The presented relations involving cp, cv, or k assume constant specific heats. If specific heats vary, property tables are needed.
- A
- 32
If specific heats vary during an isentropic ideal-gas process, what approach does the material recommend?
- A
Treat the gas as a subcooled liquid
- B
Use thermodynamic tables to determine the states
- C
Assume the outlet temperature equals the inlet temperature
- D
Continue using the constant-specific-heat relations without adjustment
Correct answer
BUse thermodynamic tables to determine the states
Explanation
The constant-specific-heat relations are less accurate when specific heats vary. The material recommends using tables to find the states in that case.
- A
- 33
Why should temperatures be expressed in kelvins when using the ideal-gas isentropic temperature-ratio relations?
- A
The relations use absolute temperature ratios, which require an absolute temperature scale
- B
Kelvins make the gas constant equal to the specific heat
- C
The relations are valid only for temperatures below zero Celsius
- D
Kelvins convert pressure directly into temperature
Correct answer
AThe relations use absolute temperature ratios, which require an absolute temperature scale
Explanation
The equations use ratios of absolute temperatures. Temperatures should therefore be entered in kelvins rather than on a scale with an arbitrary zero.
- A
- 34
An ideal-gas compressor receives air at 300K and raises its pressure from 100kPa to 800kPa. With k=1.4 and an isentropic, constant-specific-heat model, what is the approximate outlet temperature?
- A
543K
- B
1,200K
- C
800K
- D
300K
Correct answer
A543K
Explanation
Using T2=T1(p2/p1)(k−1)/k gives approximately 300(8)0.4/1.4=543K.
- A
- 35
In the compressor example, with cp≈1kJ/(kg\cdotK), what is the specific compressor power under the stated sign convention?
- A
+300kJ/kg
- B
−543kJ/kg
- C
−243kJ/kg
- D
+243kJ/kg
Correct answer
C−243kJ/kg
Explanation
The stated convention gives w=cp(Tin−Tout). Thus w≈1(300−543)=−243kJ/kg; the negative sign indicates power consumed by the compressor.
- A
- 36
Why does the isentropic compressor calculation provide a best-case power estimate rather than the exact power for a real compressor?
- A
The calculation assumes the compressor produces no pressure increase
- B
An ideal isentropic compressor is a model, while a real compressor requires more power
- C
An isentropic process always transfers heat to the surroundings
- D
The calculation assumes the working fluid has no mass flow
Correct answer
BAn ideal isentropic compressor is a model, while a real compressor requires more power
Explanation
The example assumes an ideal, isentropic compressor. A real compressor is less ideal and consumes more power than this best-case estimate.
- A
- 37
Which sequence gives the four basic components of a Rankine cycle in the order followed by the working fluid?
- A
Condenser, boiler, turbine, pump
- B
Pump, turbine, boiler, condenser
- C
Turbine, condenser, pump, boiler
- D
Boiler, pump, condenser, turbine
Correct answer
CTurbine, condenser, pump, boiler
Explanation
The basic Rankine-cycle sequence is turbine, condenser, pump, and boiler, after which the fluid returns to the turbine.
- A
- 38
What is the primary purpose of the turbine in a Rankine cycle?
- A
To condense turbine exhaust into a liquid
- B
To extract power as high-pressure vapor expands to a lower-energy state
- C
To raise the pressure of liquid water before heating
- D
To add heat to the working fluid at high pressure
Correct answer
BTo extract power as high-pressure vapor expands to a lower-energy state
Explanation
The turbine extracts mechanical power as high-pressure, high-enthalpy vapor expands and loses enthalpy.
- A
- 39
Why does a Rankine cycle condense the turbine exhaust before pumping it back to boiler pressure?
- A
A pump can increase the pressure of vapor more efficiently than liquid
- B
Compressing liquid requires much less power than compressing vapor
- C
A condenser raises the vapor pressure without power input
- D
Condensation eliminates the need to add heat in the boiler
Correct answer
BCompressing liquid requires much less power than compressing vapor
Explanation
The cycle cools the turbine exhaust into liquid because pumping liquid back to high pressure requires much less power than compressing vapor.
- A
- 40
What does the pump do to the working fluid in a basic Rankine cycle?
- A
Rejects heat until the fluid becomes a liquid
- B
Raises the pressure of the liquid returning from the condenser
- C
Adds heat to convert high-pressure liquid into vapor
- D
Expands high-pressure vapor to generate shaft power
Correct answer
BRaises the pressure of the liquid returning from the condenser
Explanation
The pump increases the pressure of the liquid leaving the condenser so it can return to the boiler at high pressure.
- A
- 41
What is the boiler's role in a Rankine cycle?
- A
To raise the pressure of the condenser's liquid outlet
- B
To lower the pressure of vapor while producing shaft work
- C
To cool turbine exhaust until it becomes liquid
- D
To add heat to high-pressure liquid and produce vapor for the turbine
Correct answer
DTo add heat to high-pressure liquid and produce vapor for the turbine
Explanation
The boiler adds heat to the high-pressure liquid, producing vapor that can expand through the turbine.
- A
- 42
Why must a heat engine such as a Rankine cycle reject some heat to a sink?
- A
The turbine can operate only if all input heat is rejected
- B
Rejecting heat ensures that the working fluid remains vapor everywhere
- C
It cannot convert all input heat into work in a cycle
- D
A heat sink supplies the pump's entire pressure increase
Correct answer
CIt cannot convert all input heat into work in a cycle
Explanation
A cyclic heat engine must reject some heat; it cannot convert all of its heat input into work.
- A
- 43
Which description best explains what makes a cycle a Rankine cycle?
- A
It must convert mechanical work into electricity inside the turbine
- B
It uses a single closed-system process with no phase changes
- C
It must use coal as its heat source and a cooling tower as its heat sink
- D
It uses a vapor dome and a sequence that moves the working fluid between liquid and vapor states
Correct answer
DIt uses a vapor dome and a sequence that moves the working fluid between liquid and vapor states
Explanation
A Rankine cycle is a vapor-power cycle involving liquid-vapor phase changes; its defining working-fluid processes do not depend on the specific heat source or generator.
- A
- 44
Which operating preference helps protect turbine blades in a practical Rankine cycle?
- A
Allow liquid droplets to strike the blades so they transfer more momentum
- B
Send a two-phase mixture into the turbine to cool the blades
- C
Keep the turbine inlet liquid and the outlet superheated vapor
- D
Keep liquid droplets out of the turbine by using vapor at its inlet and preferably at its outlet
Correct answer
DKeep liquid droplets out of the turbine by using vapor at its inlet and preferably at its outlet
Explanation
Liquid droplets can impact and damage turbine blades. The material therefore describes a preference for vapor entering and leaving the turbine.
- A
- 45
On a temperature-entropy diagram, how is an ideal isentropic turbine process represented?
- A
As a line that crosses the diagram without changing enthalpy
- B
As a vertical line because entropy remains constant
- C
As a horizontal line because temperature remains constant
- D
As a curve along which pressure remains constant
Correct answer
BAs a vertical line because entropy remains constant
Explanation
An ideal turbine is isentropic, so entropy is constant. On a temperature-entropy diagram, constant entropy is represented by a vertical line.
- A
- 46
Which property of the working fluid is required when drawing a Rankine cycle on a temperature-entropy diagram?
- A
A straight line showing constant pressure only
- B
A plot of mass flow rate against turbine power
- C
A temperature scale with no phase boundaries
- D
A vapor dome showing the liquid-vapor region
Correct answer
DA vapor dome showing the liquid-vapor region
Explanation
A Rankine cycle involves transitions between liquid and vapor, so its temperature-entropy diagram needs a vapor dome.
- A
- 47
Which sequence correctly describes the main energy transformations in a fossil-fuel power plant?
- A
Chemical energy becomes heat, raises working-fluid enthalpy, produces mechanical work, and then generates electricity
- B
Mechanical energy becomes heat, lowers working-fluid enthalpy, and then produces chemical energy
- C
Electrical energy becomes chemical energy, raises pressure, and then produces heat
- D
Heat becomes chemical energy, which directly produces electricity without mechanical work
Correct answer
AChemical energy becomes heat, raises working-fluid enthalpy, produces mechanical work, and then generates electricity
Explanation
Fuel's chemical energy is released as heat, transferred to the working fluid, converted to mechanical work in the turbine, and then converted to electricity by a generator.
- A
- 48
Which statement about the source of heat for a Rankine cycle is correct?
- A
Heat must be generated by the turbine itself
- B
Heat may come from sources such as fossil fuels, nuclear reactions, solar collection, or geothermal energy
- C
Heat must always come from burning coal
- D
Heat must always come from a nuclear reaction
Correct answer
BHeat may come from sources such as fossil fuels, nuclear reactions, solar collection, or geothermal energy
Explanation
The Rankine-cycle analysis focuses on the working-fluid components and can be used with different heat sources, including fossil, nuclear, solar, and geothermal sources.
- A
- 49
When a Rankine-cycle analysis draws a control volume around its working-fluid components, where are the heat source and electrical generator generally treated?
- A
As outside the working-fluid control volume
- B
As internal components that determine the fluid's vapor dome
- C
As parts of the turbine's internal flow passage
- D
As part of the condenser's two-phase region
Correct answer
AAs outside the working-fluid control volume
Explanation
The cycle analysis can focus on the open-system working-fluid components. How heat is supplied and how shaft work is converted to electricity are outside that component-level control volume.
- A
- 50
Which assumptions are commonly used when applying the first law to individual Rankine-cycle components?
- A
Unsteady operation, no mass flow, and large kinetic-energy changes
- B
Constant pressure in every component and zero enthalpy change
- C
Isothermal operation and zero heat transfer in every component
- D
Steady state, one inlet and outlet, and negligible kinetic- and potential-energy changes
Correct answer
DSteady state, one inlet and outlet, and negligible kinetic- and potential-energy changes
Explanation
The common component assumptions include steady state, one inlet and one outlet, and negligible kinetic- and potential-energy changes.
- A
- 51
Under the usual assumptions for an adiabatic turbine or pump, what form does the power relation take?
- A
Q˙=m˙(hin−hout)
- B
W˙=m˙(hin−hout)
- C
W˙=m˙(hout−hin)
- D
Q˙=m˙(hout+hin)
Correct answer
BW˙=m˙(hin−hout)
Explanation
For an adiabatic device with negligible kinetic- and potential-energy changes, the stated power convention gives W˙=m˙(hin−hout).
- A
- 52
For a passive boiler or condenser with negligible kinetic- and potential-energy changes, what form does the heat-transfer relation take?
- A
Q˙=m˙(hout+hin)
- B
Q˙=m˙(hin−hout)
- C
Q˙=m˙(hout−hin)
- D
W˙=m˙(hout−hin)
Correct answer
CQ˙=m˙(hout−hin)
Explanation
For a passive component, the material gives Q˙=m˙(hout−hin) under the usual assumptions.
- A
- 53
Using the stated sign convention, what sign should the power of a turbine have?
- A
Positive, because the turbine generates power
- B
Negative, because the turbine receives power
- C
Zero, because the turbine is adiabatic
- D
Positive only if heat enters the turbine
Correct answer
APositive, because the turbine generates power
Explanation
The turbine generates power, so its power is positive under the stated convention.
- A
- 54
Using the stated sign convention, what sign should the pump power have?
- A
Zero, because liquid is nearly incompressible
- B
Positive, because the pump raises pressure
- C
Negative only if heat leaves the pump
- D
Negative, because the pump consumes power
Correct answer
DNegative, because the pump consumes power
Explanation
The pump consumes power, so its power is negative under the stated convention.
- A
- 55
What signs are expected for heat transfer in the boiler and condenser, respectively?
- A
Negative in both components
- B
Positive in both components
- C
Negative in the boiler and positive in the condenser
- D
Positive in the boiler and negative in the condenser
Correct answer
DPositive in the boiler and negative in the condenser
Explanation
Heat entering the working fluid in the boiler is positive; heat rejected by the working fluid in the condenser is negative.
- A
- 56
Why is it safer to add signed component powers when finding net cycle power than to combine magnitudes without checking signs?
- A
The pump's power is a heat-transfer term rather than a work term
- B
The turbine and pump always have equal power magnitudes
- C
The first law assigns the turbine positive power and the pump negative power
- D
The first law makes all component powers positive
Correct answer
CThe first law assigns the turbine positive power and the pump negative power
Explanation
Using the signed first-law results naturally accounts for the turbine producing power and the pump consuming it. Combining magnitudes without care can lead to sign errors.
- A
- 57
What does neglecting heat loss and friction in the lines between cycle components allow an analyst to do?
- A
Assume all components have the same enthalpy
- B
Treat every component as isentropic
- C
Treat one component's outlet state as the next component's inlet state
- D
Set the cycle mass flow rate to zero
Correct answer
CTreat one component's outlet state as the next component's inlet state
Explanation
With no line losses, the fluid state leaving one component is taken to be the state entering the next component.
- A
- 58
How can the ideal-pump approximation be used when analyzing a real Rankine-cycle pump?
- A
Treat the real pump as passive and set its power to zero
- B
Replace the pump calculation with the condenser heat-transfer equation
- C
Use the ideal isentropic result as a reference, then use pump efficiency to determine the real outlet
- D
Use the ideal relation to conclude that the real outlet enthalpy equals the inlet enthalpy
Correct answer
CUse the ideal isentropic result as a reference, then use pump efficiency to determine the real outlet
Explanation
The relation Δh≈vΔp applies to the ideal or isentropic pump. A pump-efficiency model can then be used to determine the real pump outlet.
- A
- 59
For a boiler outlet specified as saturated vapor, which property method is appropriate for finding its enthalpy?
- A
Use the isentropic pump relation vΔp
- B
Use saturated or two-phase water tables at the specified state
- C
Use only the incompressible-liquid relation cpΔT
- D
Use the ideal-gas pressure-volume relation
Correct answer
BUse saturated or two-phase water tables at the specified state
Explanation
A saturated-vapor state is found using saturated or two-phase property data, not a subcooled-liquid approximation.
- A
- 60
How is the enthalpy of a subcooled-liquid state often approximated when using water tables?
- A
As the saturated-vapor enthalpy at the same pressure
- B
As the turbine outlet enthalpy at the same entropy
- C
As the ideal-gas enthalpy at the same pressure
- D
As the saturated-liquid enthalpy at the same temperature
Correct answer
DAs the saturated-liquid enthalpy at the same temperature
Explanation
The material states that subcooled-liquid enthalpy is often approximated by the saturated-liquid enthalpy at the same temperature.
- A
- 61
For a basic Rankine cycle with one turbine and one pump, how is net power found using the signed component powers?
- A
Add turbine power and pump power, allowing the pump term to be negative
- B
Set net power equal to condenser heat rejection
- C
Add the absolute values of turbine and pump power
- D
Subtract the signed pump power from the signed turbine power in every convention
Correct answer
AAdd turbine power and pump power, allowing the pump term to be negative
Explanation
With the stated sign convention, turbine power is positive and pump power is negative, so net power is their signed sum.
- A
- 62
When a steady Rankine cycle has one inlet and one outlet at each component and all components are in series, what is true of the mass flow rate?
- A
The boiler mass flow rate is independent of the condenser mass flow rate
- B
The turbine mass flow rate is zero because it generates power
- C
Each component must have a different mass flow rate
- D
The same mass flow rate passes through every component
Correct answer
DThe same mass flow rate passes through every component
Explanation
In a steady series cycle with one inlet and outlet at each component, mass conservation gives one common mass flow rate throughout.
- A
- 63
Why can mass flow rate cancel from the thermal-efficiency expression for a simple Rankine cycle?
- A
The same mass flow rate multiplies both the net power and boiler heat-input terms
- B
The condenser removes exactly the same mass that the boiler adds
- C
Thermal efficiency is defined without any energy terms
- D
The pump has no mass flow rate because it handles liquid
Correct answer
AThe same mass flow rate multiplies both the net power and boiler heat-input terms
Explanation
Because the mass flow rate is common to all series components, it appears in both the numerator and denominator and cancels.
- A
- 64
Which expression describes the thermal efficiency of a Rankine cycle?
- A
Heat rejected in the condenser divided by pump power
- B
Net power output divided by heat input in the boiler
- C
Turbine power divided by net heat transfer
- D
Boiler heat input divided by net power output
Correct answer
BNet power output divided by heat input in the boiler
Explanation
Rankine-cycle thermal efficiency measures the net power produced relative to the heat supplied in the boiler.
- A
- 65
Why is the boiler heat input, rather than net heat transfer, used in the denominator of Rankine-cycle thermal efficiency?
- A
Using net heat transfer would make the ratio fail to measure how much input heat becomes useful power
- B
Net heat transfer is always greater than the turbine power
- C
The condenser does not transfer heat in a Rankine cycle
- D
The boiler heat input is always equal to the pump power
Correct answer
AUsing net heat transfer would make the ratio fail to measure how much input heat becomes useful power
Explanation
The denominator is the heat supplied to the cycle. Using net heat transfer would not provide the intended measure of the fraction of input heat converted to useful power.
- A
- 66
For a four-state Rankine cycle numbered with state 1 at the turbine inlet, which expression gives its thermal efficiency in terms of enthalpies?
- A
(h1−h2)/(h4−h3)
- B
(h2−h1+h4−h3)/(h1−h4)
- C
(h1−h4)/(h1−h2−h4+h3)
- D
(h1−h2−h4+h3)/(h1−h4)
Correct answer
D(h1−h2−h4+h3)/(h1−h4)
Explanation
The net specific work is (h1−h2)+(h3−h4) using the signed pump contribution, and the boiler heat input is h1−h4. Their ratio gives the stated expression.
- A
- 67
In the four-state Rankine-cycle numbering, which states define the boiler process?
- A
From state 3 to state 4
- B
From state 1 to state 2
- C
From state 4 to state 1
- D
From state 2 to state 3
Correct answer
CFrom state 4 to state 1
Explanation
State 4 is the pump outlet and boiler inlet; state 1 is the boiler outlet and turbine inlet.
- A
- 68
What does a Rankine-cycle thermal efficiency of 55.3% indicate?
- A
About 55.3% of the condenser heat is converted to boiler heat
- B
About 55.3% of the working fluid becomes vapor in the turbine
- C
About 55.3% of the boiler heat input becomes net useful power
- D
About 55.3% of the turbine power is consumed by the pump
Correct answer
CAbout 55.3% of the boiler heat input becomes net useful power
Explanation
Thermal efficiency is net power divided by boiler heat input, so the percentage represents the fraction of input heat converted to net useful power.
- A
- 69
What does the backward ratio, or back-work ratio, measure in a Rankine cycle?
- A
The fraction of turbine power required to drive the pump
- B
The fraction of pump power converted into turbine power
- C
The fraction of boiler heat rejected by the condenser
- D
The ratio of condenser pressure to boiler pressure
Correct answer
AThe fraction of turbine power required to drive the pump
Explanation
The back-work ratio compares the pump power requirement with the turbine power produced, indicating how much turbine output is needed to run the pump.
- A
- 70
Why is the pump's small power requirement a benefit of using a Rankine cycle rather than compressing vapor?
- A
Liquid has greater specific volume than vapor at the same state
- B
The condenser supplies all pump power directly
- C
The pump operates without any pressure increase
- D
The pump compresses liquid, which requires much less power than compressing vapor
Correct answer
DThe pump compresses liquid, which requires much less power than compressing vapor
Explanation
Condensing the vapor before pumping makes it possible to raise pressure with relatively little power because the pump handles liquid rather than vapor.
- A
- 71
Why can a Rankine cycle have a low back-work ratio but still have limited thermal efficiency?
- A
A low back-work ratio means the boiler supplies no heat
- B
The turbine produces no power when the pump is efficient
- C
The condenser converts all rejected heat into additional pump work
- D
The pump uses little power, but substantial heat must still be rejected to the sink
Correct answer
DThe pump uses little power, but substantial heat must still be rejected to the sink
Explanation
Pumping liquid keeps the pump work small, but rejecting heat in the condenser remains necessary and reduces the fraction of input heat converted to net work.
- A
- 72
Which statement best distinguishes thermal efficiency from the back-work ratio?
- A
Both measure the fraction of boiler heat that becomes turbine power
- B
Both measure the pressure ratio across the pump
- C
Thermal efficiency compares net power with heat input, while the back-work ratio compares pump power with turbine power
- D
Thermal efficiency compares pump power with turbine power, while the back-work ratio compares net power with heat input
Correct answer
CThermal efficiency compares net power with heat input, while the back-work ratio compares pump power with turbine power
Explanation
Thermal efficiency measures conversion of boiler heat into net power; the back-work ratio measures how much turbine power is needed to operate the pump.
- A
- 73
Why might a Rankine-cycle efficiency be described as low without further comparison?
- A
The back-work ratio determines whether the thermal efficiency is low
- B
A cycle efficiency cannot be compared with any other cycle
- C
Its significance depends on comparison with an appropriate maximum, such as a Carnot efficiency
- D
Any efficiency below 100% is necessarily low
Correct answer
CIts significance depends on comparison with an appropriate maximum, such as a Carnot efficiency
Explanation
The material cautions that an efficiency should be compared with an appropriate benchmark, such as the Carnot efficiency, before labeling it low.