1. Home
  2. Explore
  3. Engineering
  4. Open-System Thermodynamics

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

Open-System Thermodynamics

Speaker 1Speaker 2

Open-System Thermodynamics

13:45
0:00-13:45
  1. Maria

    Let’s start with the basic workflow for an open-system thermodynamics problem. First, choose the control volume. Then account for mass crossing its boundary, apply conservation of energy, and—if you need to determine whether a process is possible—use the second law to check entropy generation. Those steps give you symbolic relationships for things like turbine power, heat transfer in a heat exchanger, or whether a proposed process can occur.

  2. Hope

    And even after we have those equations, we usually still need to find properties like specific enthalpy, specific entropy, or specific volume at the states. So the next big question is: what is the working fluid?

  3. Maria

    Exactly. Before that, remember that steady state and one inlet and one outlet are common assumptions, not automatic assumptions. You need to decide whether they fit the problem. For a steady, one-inlet, one-outlet device, the mass balance often simplifies substantially.

  4. Hope

    The first-law equation also depends on the assumptions. In imperial units, kinetic- and potential-energy terms need the conversion factor G C. Often we neglect changes in kinetic and potential energy, and we may treat a process as either mainly involving heat transfer or mainly involving power.

  5. Maria

    Right. For example, a turbine or pump is often modeled as adiabatic, while a boiler or condenser is often treated as passive, meaning there’s no shaft power. Those are useful simplifications, but a problem can ask you to relax them, so it’s important to know how the equations came from the first law.

  6. Hope

    What about the pipes and ducts between components? The usual cycle-analysis assumptions often neglect both friction losses and heat losses in the lines. If you include friction, pressure drops as the fluid travels, so you may have to determine the state again at the new pressure. Heat loss can change temperature too, and can change quality if the fluid is under the vapor dome.

  7. Maria

    And that’s why including line losses can make an analysis much more involved: a state you thought you had fixed at one component’s outlet may no longer be the state at the next component’s inlet. In many cycle problems, those losses are neglected because they’re small compared with the major energy terms.

  8. Hope

    If the question is whether the process is possible, we also make a second-law analysis. We often use steady state, and sometimes one inlet and one outlet. For a heat exchanger, it can be useful to draw the control volume around the whole exchanger; then it may be reasonable to treat it as adiabatic to the surroundings.

  9. Maria

    The key result of that analysis is the entropy-generation rate, usually written sigma dot. It must not be negative for a process to be possible; in the lecture’s practical test, you look for a positive value. Once the states are fixed, the mass-flow terms let you evaluate that check.

  10. Hope

    Now to the fluid question. One broad possibility is water, or another fluid that changes phase in a similar way. Refrigerants in refrigeration cycles are examples: they condense and evaporate, so we work with phase information much as we do for water.

  11. Maria

    For a phase-changing fluid, ask a second question: what phase or region is it in? Is it a subcooled liquid, a two-phase mixture, or a superheated vapor? The answer tells you which property tables to use and how to identify the state.

  12. Hope

    The other broad possibility is an ideal gas. Then ask whether specific heats are being treated as constant or variable. That choice matters because it affects which equations and property data are appropriate.

  13. Maria

    For water, you can use two-phase or superheated-vapor tables, such as those in a textbook or the FE Handbook. For a subcooled liquid, we often approximate it as incompressible, so the enthalpy change is specific heat at constant pressure times the temperature change: delta h equals c p times delta T.

  14. Hope

    There’s a handy special case for an ideal pump. If it’s isentropic, and the liquid’s specific volume changes very little, the enthalpy change is approximately the specific volume times the pressure change. That’s useful for estimating the work needed to raise a liquid’s pressure.

  15. Maria

    For an ideal gas, the same constant-pressure-specific-heat relation gives delta h equals c p times delta T when specific heats are constant. If specific heats vary, use the appropriate tables or variable-specific-heat relations instead.

  16. Hope

    For entropy, an isentropic ideal pump or turbine has zero entropy change by definition. For a subcooled liquid, the change can be approximated as c p times the natural log of T two over T one, with absolute temperatures. That has a similar feel to the liquid enthalpy approximation, but it uses a logarithm.

  17. Maria

    Ideal-gas entropy has temperature and pressure contributions. With variable specific heats, you can look up the temperature-dependent standard entropy term, often written s zero, and combine it with minus the specific gas constant times the natural log of P two over P one.

  18. Hope

    With constant specific heats, there are also compact entropy-change equations involving temperature ratios and pressure ratios, or temperature ratios and specific-volume ratios. The pressure-ratio form is often convenient for open systems, where pressures are more likely to be known; the volume-ratio form can suit a closed system, like a piston with known volume changes.

  19. Maria

    But those compact ratio equations require the constant-specific-heat assumption. They’re less accurate than the variable-specific-heat table method, which requires looking up properties. Always state your assumption rather than quietly using a formula outside its conditions.

  20. Hope

    There’s another important group of relations for an ideal gas undergoing an isentropic process. They help us find the outlet temperature of an ideal compressor or turbine, which we need before we can calculate the enthalpy change.

  21. Maria

    With constant specific heats, the temperature ratio is the pressure ratio raised to the power of k minus one over k. Here k is c p divided by c v, the specific-heat ratio. It’s greater than one, and for air it’s often approximated as 1.4.

  22. Hope

    The same isentropic ideal-gas relationships can also connect temperature and volume: T two over T one equals V one over V two raised to k minus one, and P two over P one equals V one over V two raised to k. State two here is the isentropic outlet, sometimes labeled two s.

  23. Maria

    The conditions are crucial: these relations apply to an ideal gas undergoing an isentropic process, and these particular forms also assume constant specific heats. They follow from setting the entropy change to zero and using the relation between the gas constant, c p, and c v. If specific heats vary, use property tables instead.

  24. Hope

    Let’s apply that to the compressor example. Air enters at 300 kelvin and 100 kilopascals, and leaves at 800 kilopascals. We assume steady state, adiabatic operation, one inlet and one outlet, negligible kinetic and potential energy changes, and an isentropic process.

  25. Maria

    The first law gives compressor power as mass-flow rate times h in minus h out, using the sign convention in the lecture. Divide by mass-flow rate and, for air with constant specific heats, the specific compressor power is c p times T in minus T out. We know the inlet temperature and c p, but we still need the outlet temperature.

  26. Hope

    Use the isentropic pressure-temperature relation. The pressure ratio is eight, k is approximately 1.4, and T in is 300 kelvin. That gives an outlet temperature of about 543 kelvin. Use kelvin here, because the isentropic gas relations require absolute temperature.

  27. Maria

    Then the specific compressor power is about 1 kilojoule per kilogram-kelvin times 300 minus 543 kelvin, or minus 243 kilojoules per kilogram. The negative sign means power is consumed under this convention. This is the ideal compressor result—the minimum power for the stated task—so a real compressor would consume more.

  28. Hope

    That sign check is helpful. A compressor and a pump consume power, so their power should come out negative with this convention; a turbine generating power should come out positive. Checking signs and units is a useful way to catch mistakes.

  29. Maria

    Now we can chain open systems together into a vapor-power system, usually called a Rankine cycle. Its purpose is to use heat to produce useful power. The central device is the turbine: high-pressure, high-enthalpy vapor expands through it, turning the blades and producing shaft work.

  30. Hope

    After the turbine, the fluid is at lower pressure. Rather than compressing vapor—which takes much more power—we cool it in a condenser until it becomes liquid. Then a pump raises the liquid’s pressure with relatively little power, and a boiler adds heat to turn that high-pressure liquid back into vapor.

  31. Maria

    So the simplest Rankine cycle has four components in sequence: turbine, condenser, pump, and boiler. They keep circulating the working fluid. The working fluid is often water, but it could be another fluid that boils and condenses, such as a refrigerant.

  32. Hope

    A Rankine cycle is a heat engine, so it needs heat input and also has to reject heat to a sink; it can’t turn all the input heat into power. The heat source isn’t what defines the cycle. Coal combustion, a nuclear reaction, solar collection, geothermal heat, or biomass can supply heat, and the analysis of the Rankine components is still the focus.

  33. Maria

    That’s why Rankine cycles matter in power generation. Coal-fired and nuclear plants use them, and the lecture also points to renewable heat sources that can run them. The broader energy chain might start with chemical energy in fuel, turn that into heat, then increase the working fluid’s enthalpy, produce mechanical shaft power in the turbine, and finally generate electricity.

  34. Hope

    The plant also needs equipment beyond the four components we analyze in the basic cycle. A generator converts the spinning shaft’s mechanical power to electrical power, and a cooling system provides the heat sink. Those systems matter to the plant, but the basic Rankine-cycle analysis centers on the working fluid moving through its four open-system processes.

  35. Maria

    On a temperature-entropy diagram, the boiler heats the high-pressure liquid toward vapor, the turbine ideally expands the vapor at constant entropy, the condenser rejects heat and turns the fluid back toward liquid, and the pump raises the liquid’s pressure. A Rankine-cycle diagram needs a vapor dome because the working fluid crosses between liquid and vapor.

  36. Hope

    In a real design, we generally want vapor entering and leaving the turbine, because liquid droplets can strike and damage the blades. We also want liquid leaving the condenser before it reaches the pump. The boiler then adds heat to get back to high-pressure vapor.

  37. Maria

    It can help to mark the energy directions on the diagram. Turbine power leaves the cycle, pump power enters it, boiler heat enters, and condenser heat leaves. With the lecture’s sign convention, that means turbine power and boiler heat are positive, while pump power and condenser heat are negative.

  38. Hope

    Thermal efficiency compares the net power generated with the heat input in the boiler. So it’s net power divided by heat in—not net heat transfer. If you counted net heat, the energy balance could make the result look like 100 percent, which wouldn’t be a useful measure of how much input heat became useful work.

  39. Maria

    A reliable way to handle the signs is to apply the first law to every component and add the signed results. For an adiabatic component, the power is mass-flow rate times h in minus h out. That gives positive power for a turbine and negative power for a pump.

  40. Hope

    For a passive component with no shaft power, the heat-transfer rate is mass-flow rate times h out minus h in. That gives negative heat for the condenser, which rejects heat, and positive heat for the boiler, which adds it. If the assumptions change, derive the new equation from the first law rather than relying on a memorized shortcut.

  41. Maria

    To find the states in a Rankine cycle, use the water-property methods we discussed. The turbine may require superheated-vapor data; the condenser often involves two-phase properties; and the pump may be approximated as isentropic, using specific volume times the pressure change for its enthalpy change. For subcooled liquid, the enthalpy is often approximated using saturated-liquid enthalpy at the same temperature.

  42. Hope

    Once the component equations are combined, the mass-flow rates cancel if the cycle is steady, with one inlet and one outlet at each component, all connected in series. Then efficiency can be written using specific enthalpies alone: turbine enthalpy drop plus the signed pump enthalpy change, divided by the boiler enthalpy rise.

  43. Maria

    For the four-state numbering in the lecture, state one is the turbine inlet, state two is its outlet and the condenser inlet, state three is the condenser outlet and pump inlet, and state four is the pump outlet and boiler inlet. The efficiency expression is h one minus h two, plus h four minus h three, all divided by h one minus h four.

  44. Hope

    The example cycle gives a thermal efficiency of 55.3 percent. Whether that seems low depends on what you compare it with, including the Carnot limit. The lecture emphasizes that plants continually seek better efficiency, both to produce more power from a given heat input and to reduce fuel use.

  45. Maria

    Another useful measure is the back-work ratio: the fraction of turbine power that the pump uses. With the same mass flow through the components, it’s the magnitude of the pump’s specific enthalpy change divided by the turbine’s specific enthalpy drop.

  46. Hope

    In the example, the turbine produces about 1,788.9 kilojoules per kilogram, while the pump consumes about 7.6 kilojoules per kilogram. That makes the back-work ratio very small—about four-tenths of one percent. The cycle’s liquid pump takes far less power than compressing vapor would.

  47. Maria

    There’s a tradeoff, though. Condensing the turbine exhaust requires rejecting a lot of heat to the sink, which affects thermal efficiency. A low back-work ratio is a benefit, but thermal efficiency still matters too.

  48. Hope

    So the big picture is: set up each open-system balance carefully, choose the right property method for the fluid and phase, check entropy generation when feasibility matters, and then connect the component analyses to understand the whole Rankine cycle.

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent