♻️ Sustainability in Data Centre Design: Concepts and Strategies

Data centre development is growing rapidly, and improving sustainability in design and operation is a critical focus. Significant wins can be achieved in power usage through clean, energy-efficient resources that lower operational costs and meet sustainability targets. Material choices in building design and the adoption of Design for Manufacture and Assembly (DfMA) also offer major opportunities.


Three Key Areas for Efficiency

Three main areas exist where data centre design can become more ecologically sound:

1. Efficient Building Systems

  • MEP efficiency – the systems that cool and power IT equipment. This area has been widely explored but continues to evolve.

  • Shifting from traditional air-cooled systems to liquid cooling for high-density racks offers further energy savings by eliminating the inefficiencies of fan-based air cooling.

2. Power Source

  • Decarbonisation of the grid is essential but largely outside the data centre provider’s direct control.

  • Clients are prioritising sites close to renewable energy generation. Historically, power purchase agreements (PPAs) were common; now physical proximity to renewables is a key site selection criterion.

3. Embodied Carbon

  • Embodied carbon – the emissions from material extraction, manufacturing, transport, and installation – is the area where architects and structural engineers can have the greatest impact.

  • Unlike operational savings, reducing embodied carbon often carries an upfront cost, yet it also provides a sales advantage and aligns with client sustainability aspirations.

Embodied carbon comprises the total greenhouse gas emissions associated with the entire construction process, from raw material extraction through to building completion.

  • Scope 3 emissions (indirect emissions in the value chain) are currently offset by many organisations. Reducing embodied carbon at the front end lowers the need for costly offsets at the back end.

  • For a contractor, 99.4% of their carbon footprint may be Scope 3. Minimising material use from the start is therefore a huge lever.


Embodied Carbon: From Theory to Reality

While embodied carbon is often measured and reported during early design stages, few project briefs currently include a specific embodied carbon target. As a result, the metric tends to be diluted in later stages (4 and 5) due to value engineering or loss of focus.

How to Overcome the Gap

  • Designers must demonstrate that low-carbon solutions can simultaneously save money, save time, save material, and reduce carbon – the “utopian unicorn” that benefits all parties.

  • Slabs made thinner, foundation sizes reduced, and structural steel optimised are proven examples. One project saved 11,000 m³ of concrete (equivalent to ~2,500 round-trip flights from London to New York). Another saved 25% and 30% of steel across two projects – a saving large enough to build a fifth building from the steel saved.

  • Building lean, building offsite, and building efficiently are the fastest ways to reduce carbon. Cost and time savings catch client attention.

Challenges

  • Existing legislation and regulations can make lean construction difficult.

  • End-tenant requirements are often overly stringent and unchallenged by designers. Loading requirements, tolerances, and deflection criteria are sometimes over-specified, leading to oversized structural members. Challenging these assumptions can yield significant savings.


New Materials for a Lower Carbon Future

Cross-Laminated Timber (CLT)

  • Microsoft’s CLT data centre in the US is a positive step.

  • Trade-off: When CLT replaces concrete and steel, the interaction that reduces steel (via composite action) is lost, so more steel may be needed. The overall carbon equation still favours CLT.

  • Opportunity exists to design structural systems that integrate steel and timber in ways that minimise both materials – an area largely unexplored.

Cement Replacements

  • GGBS (Ground Granulated Blast-furnace Slag) is already standard in many specifications where a source is nearby.

  • Concretene – concrete impregnated with graphene – can eliminate rebar and further reduce cement content.

  • These innovations are burgeoning but carry risk. Designers must be brave and put forward such solutions, educating clients on what is now acceptable in a modern sustainable world.

Aggregates and Cements

  • New “green” cements and aggregates are emerging, initially more expensive but falling in price with utilisation. Including them in specifications early will drive costs down across the industry.


Design for Manufacture and Assembly (DfMA)

DfMA is already used in other parts of the built environment but could be adopted more broadly in data centres.

Current Applications

  • Services cassettes – pre-assembled units that hang from ceilings.

  • Packaged plant rooms and drivetrain units that bolt onto the building.

  • However, DfMA for the building fabric itself (structure, floor plates) is rare in the UK, while more common in other regions.

Opportunities

  • Template designs applied across multiple sites allow early DfMA planning.

  • Integrating secondary systems (the frame that supports services) with the primary structural system could eliminate redundant material – each element currently provides independent strength; a combined DfMA unit would serve multiple functions with fewer materials.

  • Remote sites with labour and accommodation shortages benefit greatly from offsite fabrication, which reduces on-site work, improves safety, and ensures quality control.

  • Material wastage is reduced when components are manufactured in a controlled factory environment.

Barriers

  • Rapid programmes and strict briefs leave little time for collaborative negotiation between all parties (designers, contractors, clients, tenants).

  • Data centres require long spans (e.g. 8m × 12m clear), which are too large for a single offsite component. However, systems that can be assembled on-site from prefabricated modules could solve this.

  • The industry defaults to what it knows, insurers approve, and tenants prescribe. Bravery from designers and engineers is needed to push for DfMA solutions.


AI and Liquid Cooling

Shift from Air to Liquid

  • High-density racks drive demand for liquid cooling. Current systems can shift from 100% air cooling to ~75% liquid cooling.

  • Liquid cooling eliminates the inefficiencies of fans and the air-based heat transfer medium.

  • Chips now operate at higher off-temperatures (moving from 6–12°C to 25–30°C, and likely higher). These higher temperatures make heat reuse far more viable.

Liquid cooling uses a liquid coolant (often water or dielectric fluid) to absorb heat directly from IT equipment, offering much greater efficiency than air cooling for high-density loads.

Enabler for District Heating

  • Higher off-temperatures from chips (an extra 5–10°C) substantially improve the economics of district heating.

  • Historically, data centre heat was at “mundane” temperatures; as chip operating temperatures rise, the heat becomes a more valuable resource for surrounding buildings.


District Heating: Potential and Challenges

  • District heating is already realised in parts of northern Europe, but remains largely conceptual in the UK.

  • Implementation requires either a district heating network (complex and costly) or private agreements between industrial and residential sectors.

  • Planning authorities could play a stronger role in encouraging heat export.

  • The UK lacks the infrastructure to distribute heat widely. Success often depends on having a heat consumer immediately adjacent to the data centre.

  • The government’s AI Growth Zones (co-locating data centres in one area) raise interesting questions about how heat export could be planned and what other building uses could be included to take advantage of the heat.


Overcoming Inertia: The Role of Design Professionals

  • Cost and time savings are the most effective arguments for convincing clients to adopt sustainable measures.

  • Designers must challenge overly prescriptive tenant specs and advocate for efficient structural and MEP systems from the start.

  • Computer modelling now allows engineers to prove that traditional rules can be relaxed (e.g., lighter structures, less material) while still meeting performance and safety requirements.

  • A shift in mindset – from “we’ve always done it this way” to “let’s use modern calculations to prove a leaner solution” – is essential.

  • The combined effort of architects, structural engineers, MEP engineers, and contractors, working collaboratively, can deliver a data centre sector that remains vibrant, economically successful, and truly sustainable.


Summary of Key Takeaways

Area

Key Point

Operational carbon

Best tackled by efficient MEP systems and renewable power sourcing.

Embodied carbon

Often overlooked; can be reduced by lean design, material substitution, and DfMA.

New materials

CLT, GGBS, and concretene offer significant savings but need championing.

DfMA

Underused in building fabric; huge potential for cost, time, and waste reduction.

Liquid cooling

Enables higher energy efficiency and heat reuse for district heating.

Scope 3 emissions

Minimising material use upfront reduces the need for offsetting later.

Industry challenge

Overly prescriptive specs, fast programmes, and risk aversion must be overcome by brave, data-driven design.