Gas Chromatography Mass Spectrometry

Transcript

boom all right so again thank you  guys for stopping by today and um   taking part in our little i just say scientific  discussion on gas chromatography mass spectrometry   as many of you probably know the  science department does have a gc   mass spec located in ms 212 and you know  this workshop presentation is mostly to   give you some idea of the things that we have been  doing as far as using the gc mass spec and then hopefully uh prop some ideas promote some ideas  for your classes to possibly use the gc mass spec   as well alright so i know the title is a little  longer than what was in the initial description   the actual title was design and implementation of  practical qualitative experiments involving gas   chromatography mass spectrometry as an analytical  tool and again if you guys are just joining please raise your hand during the discussion and you can  open mic and ask a question all right so to begin

we just want to become familiar first with  gas chromatography mass spectrometry the   instrumentation and operation i've got  a background in mass spectrometry and so   there are a few more details that i'll share i  won't go too far in depth i hope but the idea is   to let you know what the instrument is capable of  doing then we want to discuss the types of samples   sample amount and sample preparation that might  seem trivial but this instrument is very sensitive i can pick up fiptomolar and that's femto meaning  the prefix femto molar amounts of sample and so   it's very critical that you prepare your sample  properly when you get ready to use the gc mass   spec and then finally we got a showcase at the  end we have two projects one involving uh cbd oil   that we've done with my class and then one that  david will cover we talk about retention bonds

all right so let's go ahead and talk about what  gc mass spec is it's an analytical method that   combines the features of gas chromatography and  mass spectrometry to identify different substances   within the test sample and i point out that it  is an analytical method of course everybody knows   i guess there are five areas of uh chemistry  analytical chemistry being one specific area   i'm an analytical chemist i know dr carlos  baichi diaz is also an analytical chemist and in analytical chemistry we study and use  instruments and methods to separate identify   and quantify matter and so you might think of  this notion of separating and identifying if   you're identifying things that's the qualitative  part okay and so that's what our entire field   does so this instrument is primarily used in  analytical chemistry of course it's two things   it's gas chromatography that's a common type  of chromatography used in analytical chemistry

for separating and analyzing compounds that can be  vaporized without decomposition as the name states   it's gas chromatography all right so you've  got solid liquid and gas in this case if the   sample cannot be turned into a gas at a regular  temperature meaning up to 120 to 300 degrees   then you probably can't use it in this instrument  and then lastly here we have mass spectrometry is   an analytical technique that's used to detect  and measure mass to charge ratio of ions so

here's a little summary of kind of that same thing  here so gas chromatography mass spectrometry is   what we call a hyphenated analytical technique  which means it's two techniques that are combined   to form one single method of course the gc again  is dealing with volatile organic compounds all   right and the mass spec is our detector so let's  get into a more detail of the instrumentation   this is a picture of the instrument that we have  in ms212 there are a number of parts up here that you'll see in another diagram coming up but i just  wanted to point them out so in case you come into   the room you'll know what the system is designed  for and have all the parts for it i got a carrier   gas over here in the corner so that carrier  gas is a helium gas for this particular system   got an injection port and this injection board i  wish i had a video of it but anytime you watch a   csi program on television they'll typically have  the auto sampler for the gc running because it

spins around it's a little robot arm that  picks up the sample and drops it into a   area so that you can have a needle pierce it and  then inject into the actual instrument and then   finally have this region the gc itself then your  mass spectrometer and your data system so let's   dig into these with a little more detail the first  thing we want to talk about is the carrier gas   okay so when we talk about chromatography now  you got to talk about two different phases you have what we call a mobile phase which as the  name is stated it's a moving phase and so in   the case of our carrier gas which sits in our  tank the carrier gas pushes in our case helium   throughout the entire system so the carrier gas  is hooked up to the injector the injectors hooked   up to this gas chromatography column and then  your column goes into your mass spectrometer   so the carrier gases that we usually use  are going to be inert gases meaning that

they are not reactive gases if you put them  with other compounds or chemicals they don't   cause a reaction with those other chemicals  so we're talking about things like helium   and nitrogen now on occasion they'll use hydrogen  sometimes hydrogen's a little bit cheaper but in   our particular case we don't want to use hydrogen  because hydrogen is flammable so our carrier gas   is running through the system the next area  you'll note is the injector port okay so the injector point is that region that i pointed out  that was on top of the mass spec in our diagram   it's also got a syringe and the injector injects  the sample into the flow of the carrier gas   and in this region your carrier gas passes  through onto your column once the sample gets in   it's immediately volatile so it's turned into a  gas by a high temperature typically our injection   injection ports are sitting  at about 120 degrees celsius

so if you're familiar with the boiling point of  water you know that water boils at 100 degrees   most of the samples that we want to inject can  be turned into a gas at much lower temperatures   so if you enter that sample put that sample into  this injection port at 120 degrees or 150 degrees   in some instances automatically the sample gets  turned into a gas so samples are can be diluted   we talked about the sensitivity how little amount  of sample that you have to be able to put into this instrument we can dilute the sample at the  injection port okay so that's one of the details   that makes this instrument pretty nice is that  you can do some dilution within the system itself

next we're going to go to the gc column and the  column itself is placed in an oven it literally   is an oven and the oven of course can go from  40 degrees all the way up to 350 degrees celsius   and the idea is that you are slowly heating the  column over time and as you slowly heat the column   samples that are slow to be moving because they're  at a larger molecular weight where they have more

interaction with the column itself they actually  start to boil and move more quickly through the   column okay so the whole separation process takes  place as a result of heat and the column itself   the columns are generally about 15 meters to  60 meters long so that's that coil that you   see here in my diagram and the key there is that  the length of the column gives you theoretical   plates that's a principle but the short end of  it is you can think of it as rocks in a river

so the gas chromatography or the carrier gas  is like the water flowing through the river   and then if you have rocks in a river and you have  a small raft you can easily navigate the river   but if you have a large raft then it becomes more  difficult to navigate all the rocks and therefore   you move more slowly so certain compounds will  interact with the gc column more than other ones   and if they interact more as a result of the  column and the compound itself then they'll come out of the column last okay so columns are  a stationary phase that will retain compounds   based on how they interact with the column  this is a side note when i worked in industry

the guys in industry talked about how they used to  take their cans of soup before they had microwaves   and they would sit them in the gc ovens and they  would heat their cans of soup inside the gc ovens   of course we wouldn't do that today  there'd be a safety issue with that   but it is just another all right so the next  system there is going to be your mass spectrometer and i'm sorry one more detail about the column so  your things are getting separated on the column   and as they're coming off the column you can note  here this is a counts versus acquisition time so   the first items that you see down here  about 4.4 4.6 at about 4.5 this compound   came off of the column first and then you can see  successively that each of these other compounds   comes off the column at a later time the idea  being that these columns that come off very late

in this case around 7.8 minutes those columns had  a lot of interaction with are those compounds had   a lot of interaction with the column and so they  came off later and this becomes important because   this retention time is one of the things  you can use to help identify your sample all right so now on to the mass spec uh so  your mass spec is your detector all right so   compounds are separated as transferring through  the heated area right here between the two   instruments and then you have three parts to the  mass spectrometer i have an ionizer a mass filter   and a detector let me go into that in a little  more detail so over here you have a gc stream

and your gc compounds the compounds  that are being separated are going   to flow through the entrance of the source so  this is the ionizer this area right over here   notice that i've got an arrow here to neutral  compounds so things that come through the gc   have no charge meaning they're not  positively charged or negatively charged   they're neutral when they get into the  ionizer they go through a beam of electrons

and these electrons interact with each one of  these compounds and they knock off an electron   and if you remember from your general chemistry  if you remove an electron from a compound   ultimately create a positive charge because the  electron is negatively charged so by passing   through this beam now each one of these compounds  has a positive charge so that's the ionizer that's   what it does is create ions from there it passes  through what we call a mass filter and there are different types of mass filters but this one that  i have represented here is called a quadrupole   and it's essentially four different rods and  in these four different rods you will create   or you'll have different voltages so the top one  and the bottom one might be positively charged   the one at the back and the one and closer to  the front would be negatively charged and then   you alternate those voltages very quickly and  what that does is if you have something that's

positively charged moving through the rods as  they encounter the positive rod they'll start   to move away but then as they start to go up and  you flip the voltage now that positive charge is   on the top right and they'll be pushed back down  so you essentially filter the positive charges   through this region all right so that's why it's  the mass analyzer now we place a dc voltage on   this and we scan it and that dc voltage allows us  to get what we call the mass to charge ratio um

and basically a massive charge ratio if you have  a compound like water and water is a mass of 18   then the charge on it would be one so 18 divided  by one would be one so the mass that you would see   is 18. all right so once it gets through there  then it goes on to your detector and once it gets   in the detector it strikes a plate that causes  an electrical signal all right so that's the   details of our mass spec that electrical  signal goes over to the data system

and our data system has basically two things that  it can show obviously you've got your chromatogram   that was based on your gc so you've got all your  various compounds that are coming out and then   you've also got a mass spectrum and in this case  a mass spectrum with your master charge ratio   gives you different pieces or different ions  that are based on the one compound that came   through the instrument at a single time so if  we go back to the compound that came out at position or time number four  on this particular chromatogram

all of this mass spectrum represent that one  compound at that one particular time and we'll get   into more detail about that in just a moment all  right so in summary you've got to carry a gas you   inject your sample the gas chromatograph actually  separates the mixture your mass spectrometer   detects the compounds and then your data system  collects and analyzes your data all right so that's it for the first part i hope  that was good there as far as explaining   kind of the components of the gc mass spec let  me move on to some of the sample preparation   we'll talk about sample state and amount first and  the key there i said earlier is that you have to   have compounds that are going to be volatile  so compounds must be soluble in a solution   for them to be injected onto the gc  the solvent itself has to be volatile

generally organic so for example we will  use hexane and we'll use dichloromethane   uh hexane i if you guys will note is a nonpolar  solvent while dichloromethane is a polar solvent   all right the key is here that however water  being polar water should not be used as a solvent   water is a no no in gc and that's because  if you put water in the instrument   water's boiling point is 100 degrees and if  you were to inject it on the gc column it would

actually crash out as a liquid and that would  be a liquid until it reached the temperature   above 100 degrees at which point it would start to  turn into a gas and then essentially it would fill   up the entire column because you have so much  of it okay so water we don't want to use the   hexane and the dichloromethane boil in much lower  temperatures and as a result they'll be off of the   column very quickly because they don't need a high  temperature for them to go and turn into a gas

for the amount of sample that's going to depend  on the ionization method in our case it's electron   impact but the sensitivity of the instrument is  about one to one hundred picograms per component   and so i always tell dr vajradias with his organic  class dilute it once then dilute it again and   finally dilute it in the instrument because  the instrument is really very very sensitive   the injection amount is actually one microliter  and they give you some idea of one microliter injection for that liquid if you inject or push  the syringe down the one microliter does not   have enough weight to actually drop off the  end of the syringe okay that's how small of   an amount that that one microliter is okay so  let's move on now to the sample preparation so sample preparation can change from  simply dissolving some of the sample in   a suitable solvent to extensive methods and  we'll kind of see that today with the two

projects that we'll show the first thing here  with your cleanup procedures they can take various   forms you can have liquid liquid extraction so  if you look over here to the side this might be   a simple liquid liquid extraction in this case  you might have hexane on top and then water on   the bottom and the water would be drawn out of the  bottom of the container and then the hexane would be drawn out and then you'd re-add your water and  then your hexane add a new layer of hexane and you   shake this up to actually extract your compounds  from your water that's a liquid liquid extraction   or we've also tried solid phase extraction in a  couple of places i know we tried them in geology   and solid phase extraction you have a solid  phase that's located in a typically a tube   and you add your sample to the tube and then using  pressures either negative or positive pressure

you allow the sample to pass through a solid phase  i always tell people it looks like sand but it's   actually silica glass that's been modified so you  can capture quite a bit of your matrix the key   here is that you want to take as much of the dirty  stuff so for example if you literally had dirt   you could mix it up pour it on top and then the  dirt would stay in the tube and your soluble components would pass through the syringe area and  you can collect them so you want to get rid of the   matrix and then put as much of the compound of  interest into the instrument so those are just   two methods there are quite a number but these  are pretty common methods all right so how do we   perform this qualitative analysis uh so the first  thing here this is different from quantitative   okay i want to point that out early  on if you uh look at qualitative data

qualitative data just gives you information about  the properties or the attributes of your sample so   in this picture you have different colors you have  a precipitant this can tell you that a compound is   there but it does not tell you quantitative data  which is how much of a sample you have so maybe in   the future we'll give a presentation about doing  actual quantitative analysis with the gc mass spec but we're talking about qualitative we generally  just want to figure out what compounds are there

so qualitative analysis uh your chromatography  this is all from your data system chromatography   gives the retention time for your compound so in  this particular case this is a chem 151 sample   they are asked to make aspirin from  a salicylic acid and in this case the   student did not do so well the salicylic acid  can be found here at 8.35 and you can look at   the mass spectrum this fragmentation pattern  that you have over here tells you that you have salicylic acid all right so those are  the two main ways that you'll identify the   compound the first is the retention time and  then the other one can be the mass spec pattern

so for your gc if you have a compound  for example the salicylic acid   you can't really identify the compound without  the mass spec and so what you'll do is you'll   inject a standard and so i would go  to the lab and i would get a standard   of salicylic acid and i would inject it using  the same chromatography conditions and it would   give me a retention time and then when i inject  a sample of unknown if i have a compound that comes out at the same retention time then  i can probably say that that same compound   is the standard or is the same as the standard  in this case it would be salicylic acid okay   so as long as the gc method is unchanged compounds  will elute from the gc column at the same or very   similar retention times so that's why we use our  standard as far as the mass spec is concerned   we can use a database so we'll go over to what  we call the webbook.gov.nist that's the website

and you can type in salicylic acid and when  you type that in it'll give you this page   and right down here it'll say the mass  spectrum for it so you can look at that mass   spectrum and match it to your mass spectrum and gc  fragmentation is very specific it creates the same   fragmentation pattern for that compound each time  and so we can match this fragmentation pattern   to the fragmentation pattern in the database  and that will tell us that we have that compound

so here's that example this one's from  the nist web book so you see here the 138   120 92 for the salicylic acid in our gc sample you  see the 138 the 120 and the 92 and the abundances   meaning the intensities are about the same so that  tells you that you probably have the salicylic   acid right if you do not have a database then  you have to interpret the mass spectra or have   a known standard of the compound uh if you want  uh we can do some discussion later about how to

interpret mass spectra but i can tell you that's  an entire course within itself all right so let's   move on now to the qualitative analysis we've got  two different projects that we've been working on   the first one here is qualitative analysis of  cannabinoid which is also known as cbd and then   i'll let david introduce his a little bit  later that's the qualitative analysis of vocs   in retention pond water so first thing about  cbd i think most people have heard of cbd if you go to the grocery store i know in the checkout  lines at the grocery store they have cbd products

i'm pretty sure they're sold in the malls i'm  pretty sure they're sold at the vitamin shop the   gnc you can order them from all over the place so  it's become a very hot topic gcml's gcms analysis   can be used to look at the components found in  any of these cbd samples and chemical structure   is one of the objectives for general chemistry and  so i have over here to the side two different cbds now if you look up cbd you don't find these two  structures this is actually from the nist website   and for those who are savvy they notice that  everything else in these two structures is the   same except for this little wedge that's on the  top here this wedge is solid and down here on the   lower one it's a dashed wedge so if you took dr  vajidi as his organic class you would note that   the wedge that's solid means that this front part  is coming towards you and that's a chiral center

and on this lower one the wedge or the dashed  line means that this part is going away from you   and that's another chiral center okay so it looks  like there are two different cbd components so in   this case we'll look at this in a second but uh  we want to pay attention to that please remember   that you have two different cbd's there  so the sample preparation is just dilution in this case you have a chromatogram  of our cbd samples we have a standard that came off the column at about 14.54 minutes  and so this is a known standard we just diluted   it and put it directly in the system to check  and make sure that we had retention time and   that it was what we say it is the actual cbd  results for the cbd compound show a few other   components right so this particular sample on the  bottom is a sample that we ordered and this sample   has more peaks in it than the standard which it  should right because cbd is a natural product

so the additional peaks that were found in the  sample we tried to identify those using mass   spec and what we find is that the peak that's  at the back is thc now i point that out because   i'll show you here in a moment that um  the fda has a level uh cannabinoid is not   i'm sorry the cannabis plant the hemp plant is  not a marijuana plant and so therefore it has a   level of thc in it but you should not have a huge  amount of thc in it you also point out that these

other two peaks this is the peak at 14.54 that  is the cpd standard but i found another peak at   13.96 that's also a cbd so if you look this up in  the database it has a very similar mass spectrum   to the other mass spectrum for the cbd so  there's the instrument itself seems to have   resolved two different cbds but there's only  one that we ordered for the standard okay so   without the mass spec we wouldn't know  what these other components are okay and just as a side note uh  just because we're dealing with   cbd here i'm not going to read all this to  you guys but i do want to point out that   cbd is a single component found in the cannabis  plant and because it is these other components   are probably there so when students get in my  classroom and they start to talk these things   i point out to them that there are a ton of  other things kind of like the tea tree oil

had a bunch of stuff in it there can be a number  of other things that are found in these things the fda has only approved one cbd product  and that's to treat things like seizures these other type of things up here  i know the seizures are a big deal you can actually go out and google cbd  pbs and they have quite a number of videos   that talk about how cbd is used to treat  seizures and then there are a couple of other   details down here but the key is that you know  cbd itself is a product where it's one compound   but a lot of the things that students are  talking about have a number of other things   that can be shown with gc mass spec all right  so let me switch over uh david did you want to

fill us in on your background for your retention  pond water yeah so i had this idea a while back   um because in my geology 111 class in lab i do  a flood hazards lab and if you weren't aware of   these ponds that we have on campus and all around  eastern north carolina are a very simple way to control flooding so what they do is they storm  they store the storm water temporarily and they   let it the the water soak into the ground more  naturally versus uh storm drains that that pipe   that directly to the rivers and that can cause  flash flooding so i had this idea that since we're   we're we're draining this impervious surface aka  parking lots where we can have vehicles that uh   leak all sorts of petroleum that that possibly  over time that the stormwater retention ponds

could be point sources for pollution means we  know exactly where that pollution came from   so we've got some uh results of of uh  that we if we spike the sample we can   retrieve it um but we have not yet been able  to detect it in the water now you can see   in the upper right hand corner of the screen  there you can see this is this is right outside   the where i park every day and this was right  after a rain so that is oil that is on the ground and so you can see that that is going  to eventually end up into the retention pond   uh depending on the results of the water i  would also like to do some coring of soil   around the ponds to see if we can detect  any uh petroleum in the in the soil as well

but because of laboratory contamination we're  having some issues with with getting some good   results uh hopefully at some point in time we'll  get this instrument called a purge and trap   where it does the extraction for you and  injects into the gc mass spec so the the   points of contamination is dramatically reduced  but as of yet we've not had we've not been able to   uh acquire that piece of equipment and that's all  all right thank you david and like like you said i

mean uh we've got a project or a method for this  and that method is very involved uh that's kind   of why we want to try and get the purging trapped  um the method itself is a liquid liquid extraction   and this is just a diagram of liquid liquid  extraction i kind of talked about it earlier   um but if you've been to the chemistry lab in room  ms212 and even in the prep room in between you've probably seen these huge two liter uh separatory  funnels and what we do there is we'll add in about   500 milliliters of pond or retention pond water  and then we'll add in maybe 30 to 100 milliliters   of dichloromethane or hexane and you shake your  sample with those particular solvents and then   of course the dichloromethane is more dense so it  would be on the bottom hexane would be on the top

but either way you let the elements out of your  separatory funnel and then you might do two or   three other extractions to try and get your  sample cleaned up and the key here is that   you want to concentrate your sample because the  pond water is going to have such a small amount   of compound in it it's important to take almost  a liter of sample and concentrate it down to   maybe a milliliter so you're doing a thousand  whole concentration there these are some of the details of what we're using so we use a  deuterated standard for analysis and when you   hear the word deuterated that means you have  three different isotopes for hydrogen isotopes   meaning that you have more neutrons it's the same  element but you have more neutrons in the nucleus   and a neutron is going to make it way a little  bit more it's going to make it way one atomic mass   unit more and so we have a deuterated standard  of octane because of course we'd be looking for

things that are gasoline type so octane itself and  we pass it through that liquid liquid extraction   procedure the key is that we can spike that  octane standard directly into our water sample   before we start to do the extraction process all  right so results here are just from the mass spec   your standard and then the mass spectra from that  particular compound so here's the compound itself   and what you want to think about is for every  single hydrogen that you would have on the octane

you're going to get one deuterium and so that  deuterium is going to add one additional mass   unit so what that means is that you can put  this particular compound into the extraction   and even if octane is in the  extraction or the pond water itself   then you can still have them separated by mass  to charge the mass spec can tell the difference   the gc cannot tell the difference but the mass  spec can tell the difference the retention times for the two compounds would be the same but  the mass spec tells you it's different and the   big thing there is that later on we'll use this  standard for qualitative or quantitative analysis   because we can take peak areas and we can  normalize things because we know how much   of this particular compound that we are  adding to the sample and so we can use   that to figure out how much we've recovered  when we take it through the extraction process

all right so that's our pond water analysis these  are other applications up here um that are just   from literature and hopefully you'll see one up  there for you um let me encourage everybody to   you know if you want to use the gc mass spec  for any of your laboratory work uh please let   me know there's probably a technique out there  that we can use even if it's plants i know i've   worked with mr horn in the past on trying to do  things for tomatoes we've also had a number of other things like i say the aspirin lab if you  want to do kinetics we can do things like that   so with that i think that concludes everything  for us does anyone have any questions please

it's quiet as a mouse okay all right well if you  guys have no questions i know i got a question   yes sir uh if could you use this technique to  measure ethanol concentrations like produced by   fermentation yes sir you can in  fact that would be a great project because that's just a specific  gc there's an actual gc method   for looking at the various alcohols and so  we could just switch over to that method   make the injection and go from there but yes  that can be done very easily all right thanks

other questions i see carlos has one up here you  can also use an ir instrument to do that yes he's   right you can also use the ir instrument to do  that and we also have the lc instrument that you   might be able to do that with as well so there  are a number of analytical pieces of equipment   mark that we might maybe  can use to do that analysis you spoke of how gc fragmentation is very  specific however and i'm trying to word   my question as best i can based upon  my understanding of your very well very good presentation are there  any redundancies among chemicals

uh so are you saying are there fragmentation  patterns that are similar yes among compounds yes in fact i'm sorry even with  the example you presented um yeah i think you you interpreted  my question correctly yes yes so yeah the uh compounds themselves  the two that i presented have chiral centers so those were resolved because  we had the gc in front of them however without the gc the mass spec could  not tell the difference and so that's the key   is that the mass spectral mass spectrum for  each of those compounds would look the same

but we know that they're different because they  had different elution time illusion times on   the gc so you are correct that you'll have very  similar patterns and i see uh dr carlos actually   pointed out that hydrocarbons have very similar  patterns they do hydrocarbons break apart um   based on the number of carbons that they have so  for example if you had octane you can expect to   see between eight and probably six groups that  are separated by 14 daltons in the mass spec the issue becomes that there are different  arrangements of those hydrocarbons so it doesn't   have to be a long chain it can actually have side  chains and things like that generally side chains   will break off and you'll have a very significant  gap when you actually interpret the mass spectrum

but you are correct that you can have some and  we use those groups those very similarities in   the mass spectrum to say that yes you do have a  six-membered ring for example you have a benzene   ring fragment that's very well known or if you  break off a hydroxyl which means you have a loss   of 18 because you have hydrogen and oxygen and  then you add one hydrogen to it so you can lose 18   that specific loss tells you that you have a  certain pattern and so again it would takes a little bit to be able to interpret mass  spectrum right there's a lot of books on how   to interpret mass spectrum but they do in some  cases have a lot of overlap okay great thank you

and i see carlos's point up here you know that's  a fascinating thing carlos i would like to get   some understanding of what's  going on in that gc mass spectrum   it was identified carlos is saying that those  enantiomers the two different cbds have very   similar structures so theoretically we were not  doing chiral chromatography so the only thing that   would separate them would be their boiling  point or their interaction with the column and so that's a real question that i have is you  know was that first peak it showed up as cbd i   need another standard of a different chiral center  cbd to say for sure that it is a different cbd that's a good point yet but diastone would  have a different boiling point that's correct

so those are the details in there that and i  thank you um dr value for your interjection   because i think that's where my thought was  going when i asked about the redundancies i just didn't know to relate it to the  enantiomers or the diastereomers so thank you yep good science are there other questions any discussion points you want to  add anybody want to add anything

thanks carlos all right well if no one has  anything else let me encourage you guys   you know if you think of anything like mark was  saying look at fermentation or even if you want   to look at constituents of some plant that's  in the greenhouse or anything like that or if   you're doing i know we're not supposed to use  human blood or if something like that comes up   we can try and always run them on the mass  spec and think of some different projects to be used on the mass spec so  please let me know if you have any uh   ideas and i'll be around thank you guys  for coming by today i appreciate it