1. Home
  2. Explore
  3. Chemistry
  4. Gas Chromatography Mass Spectrometry

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

Gas Chromatography Mass Spectrometry

  • 61Unfamiliar
  • 0Learning
  • 0Familiar
  • 0Mastered
Topic: GC-MS Fundamentals

What does gas chromatography–mass spectrometry primarily do?

61 questions

  1. 1

    What does gas chromatography–mass spectrometry primarily do?

    1. A

      It measures only the total mass of an unseparated sample

    2. B

      It separates substances and identifies them within a sample

    3. C

      It determines only the temperature at which a sample boils

    4. D

      It converts every compound in a sample into a solid

    Correct answer
    B

    It separates substances and identifies them within a sample

    Explanation

    Gas chromatography–mass spectrometry combines separation by gas chromatography with identification by mass spectrometry.

  2. 2

    Why is gas chromatography–mass spectrometry called a hyphenated analytical technique?

    1. A

      It uses two identical chromatographs in sequence

    2. B

      It analyzes samples using two different solvents simultaneously

    3. C

      It combines two analytical techniques into one method

    4. D

      It requires two separate samples for every measurement

    Correct answer
    C

    It combines two analytical techniques into one method

    Explanation

    A hyphenated technique combines gas chromatography and mass spectrometry into a single analytical method.

  3. 3

    What three broad activities are central to analytical chemistry?

    1. A

      weighing, filtering, and evaporating every sample

    2. B

      Separating, identifying, and quantifying matter

    3. C

      Heating, freezing, and dissolving matter

    4. D

      Synthesizing, purifying, and crystallizing proteins

    Correct answer
    B

    Separating, identifying, and quantifying matter

    Explanation

    Analytical chemistry uses instruments and methods to separate, identify, and quantify matter.

  4. 4

    What type of compounds is gas chromatography especially suited to analyze?

    1. A

      Compounds that can be vaporized without decomposition

    2. B

      Compounds that decompose before they can enter the instrument

    3. C

      Compounds that are insoluble in every available solvent

    4. D

      Compounds that remain solid at all operating temperatures

    Correct answer
    A

    Compounds that can be vaporized without decomposition

    Explanation

    Gas chromatography separates and analyzes compounds that can be converted into a gas without decomposing.

  5. 5

    What does mass spectrometry measure directly for ions?

    1. A

      Their boiling points only

    2. B

      Their solubility in water

    3. C

      Their density-to-volume ratios

    4. D

      Their mass-to-charge ratios

    Correct answer
    D

    Their mass-to-charge ratios

    Explanation

    Mass spectrometry detects and measures the mass-to-charge ratio of ions.

  6. 6

    What is the primary role of the gas chromatograph in a GC-MS system?

    1. A

      To separate the components of a mixture

    2. B

      To determine the concentration without separation

    3. C

      To convert ions into electrical signals

    4. D

      To compare spectra with a reference database

    Correct answer
    A

    To separate the components of a mixture

    Explanation

    The gas chromatograph separates the compounds in a mixture before they enter the mass spectrometer.

  7. 7

    What is the primary role of the mass spectrometer in a GC-MS system?

    1. A

      To detect compounds after chromatographic separation

    2. B

      To maintain the column at room temperature

    3. C

      To dissolve samples before they are injected

    4. D

      To supply helium through the chromatographic column

    Correct answer
    A

    To detect compounds after chromatographic separation

    Explanation

    The mass spectrometer acts as the detector, producing information about compounds after they leave the GC column.

  8. 8

    Which type of analysis mainly determines what compounds are present rather than how much is present?

    1. A

      Thermal analysis

    2. B

      Qualitative analysis

    3. C

      Gravimetric calibration

    4. D

      Quantitative analysis

    Correct answer
    B

    Qualitative analysis

    Explanation

    Qualitative analysis describes the properties or identity of substances, whereas quantitative analysis determines their amounts.

  9. 9

    Which sequence correctly summarizes the operation of a GC-MS system?

    1. A

      The sample is quantified by the injector, separated by the detector, and ionized by the oven

    2. B

      The sample is separated by MS, heated by the data system, and injected into the GC

    3. C

      The sample is injected, separated by GC, detected by MS, and analyzed by the data system

    4. D

      The sample is detected by MS, injected, separated by GC, and discarded by the data system

    Correct answer
    C

    The sample is injected, separated by GC, detected by MS, and analyzed by the data system

    Explanation

    The carrier gas moves the injected sample through the GC column, the GC separates it, the MS detects it, and the data system collects and analyzes the results.

  10. 10

    Why must a sample generally be volatile for GC-MS analysis?

    1. A

      It must be converted into a gas and transported through the column

    2. B

      It must react with the carrier gas to produce a liquid

    3. C

      It must form a solid precipitate before entering the detector

    4. D

      It must remain permanently dissolved in water during analysis

    Correct answer
    A

    It must be converted into a gas and transported through the column

    Explanation

    Gas chromatography requires compounds that can be vaporized and carried through the column as gases.

  11. 11

    What is the function of the carrier gas in gas chromatography?

    1. A

      It chemically reacts with each sample component

    2. B

      It measures the mass-to-charge ratio of each compound

    3. C

      It moves the injected sample through the instrument

    4. D

      It converts the sample into ions inside the detector

    Correct answer
    C

    It moves the injected sample through the instrument

    Explanation

    The carrier gas is the mobile phase that transports the sample from the injector through the GC column and toward the mass spectrometer.

  12. 12

    Which gases are commonly used as inert GC carrier gases?

    1. A

      Helium and nitrogen

    2. B

      Oxygen and chlorine

    3. C

      Water vapor and ammonia

    4. D

      Carbon dioxide and ozone

    Correct answer
    A

    Helium and nitrogen

    Explanation

    Helium and nitrogen are commonly used because they are relatively inert and do not readily react with sample compounds.

  13. 13

    Why was hydrogen not selected as the carrier gas for the system described?

    1. A

      Hydrogen is flammable

    2. B

      Hydrogen cannot be stored in a pressurized tank

    3. C

      Hydrogen is always chemically reactive with helium

    4. D

      Hydrogen cannot move through a column

    Correct answer
    A

    Hydrogen is flammable

    Explanation

    Hydrogen can be used in some systems and may be less expensive, but its flammability creates a safety concern.

  14. 14

    What happens to a sample in the GC injector port?

    1. A

      The sample is diluted only after reaching the detector

    2. B

      The sample is ionized and sorted by mass before entering the column

    3. C

      The sample is injected into the carrier-gas flow and vaporized by heat

    4. D

      The sample is frozen and deposited onto the column

    Correct answer
    C

    The sample is injected into the carrier-gas flow and vaporized by heat

    Explanation

    A syringe introduces the sample into the carrier-gas stream, and the heated injector port rapidly vaporizes it.

  15. 15

    What is the approximate operating temperature of the injector ports described?

    1. A

      About 500 ∘C500\,^{\circ}\mathrm{C}500∘C, with some cases near 600 ∘C600\,^{\circ}\mathrm{C}600∘C

    2. B

      About 20 ∘C20\,^{\circ}\mathrm{C}20∘C, with some cases near 30 ∘C30\,^{\circ}\mathrm{C}30∘C

    3. C

      About 0 ∘C0\,^{\circ}\mathrm{C}0∘C, with some cases near 10 ∘C10\,^{\circ}\mathrm{C}10∘C

    4. D

      About 120 ∘C120\,^{\circ}\mathrm{C}120∘C, with some cases near 150 ∘C150\,^{\circ}\mathrm{C}150∘C

    Correct answer
    D

    About 120 ∘C120\,^{\circ}\mathrm{C}120∘C, with some cases near 150 ∘C150\,^{\circ}\mathrm{C}150∘C

    Explanation

    The injector ports were described as typically operating near 120 ∘C120\,^{\circ}\mathrm{C}120∘C, although some applications use approximately 150 ∘C150\,^{\circ}\mathrm{C}150∘C.

  16. 16

    What is the purpose of the oven surrounding the GC column?

    1. A

      It cools the column so all compounds condense immediately

    2. B

      It measures the electrical signal produced by the detector

    3. C

      It gradually heats the column to help separate compounds

    4. D

      It ionizes compounds before they enter the carrier-gas stream

    Correct answer
    C

    It gradually heats the column to help separate compounds

    Explanation

    The oven slowly increases the column temperature, causing compounds to move through the column at different rates.

  17. 17

    What temperature range can the GC oven described in the presentation reach?

    1. A

      Approximately 350350350 to 700 ∘C700\,^{\circ}\mathrm{C}700∘C

    2. B

      Approximately 800800800 to 1,000 ∘C1{,}000\,^{\circ}\mathrm{C}1,000∘C

    3. C

      Approximately 404040 to 350 ∘C350\,^{\circ}\mathrm{C}350∘C

    4. D

      Approximately 000 to 40 ∘C40\,^{\circ}\mathrm{C}40∘C

    Correct answer
    C

    Approximately 404040 to 350 ∘C350\,^{\circ}\mathrm{C}350∘C

    Explanation

    The GC oven was described as operating from approximately 404040 to 350 ∘C350\,^{\circ}\mathrm{C}350∘C.

  18. 18

    What is the typical length range of the GC columns described?

    1. A

      Approximately 111 to 555 centimeters

    2. B

      Approximately 151515 to 606060 meters

    3. C

      Approximately 500500500 to 1,0001{,}0001,000 meters

    4. D

      Approximately 100100100 to 300300300 meters

    Correct answer
    B

    Approximately 151515 to 606060 meters

    Explanation

    The columns were described as generally ranging from about 151515 to 606060 meters in length.

  19. 19

    Why do compounds that interact more strongly with the GC column elute later?

    1. A

      Stronger interactions prevent them from being vaporized in the injector

    2. B

      Stronger interactions cause them to reach the detector first

    3. C

      Stronger interactions make them bypass the column entirely

    4. D

      Stronger interactions retain them longer in the stationary phase

    Correct answer
    D

    Stronger interactions retain them longer in the stationary phase

    Explanation

    The GC column is a stationary phase, and compounds that interact with it more strongly spend more time retained and therefore elute later.

  20. 20

    In the river analogy for a GC column, what does a larger raft represent?

    1. A

      A carrier gas that flows more rapidly through the column

    2. B

      A detector that produces a larger electrical signal

    3. C

      A compound that has more difficulty navigating column interactions

    4. D

      A compound that has no interaction with the stationary phase

    Correct answer
    C

    A compound that has more difficulty navigating column interactions

    Explanation

    A larger raft has more difficulty moving around the rocks, analogous to a compound that interacts more strongly with the column and moves more slowly.

  21. 21

    What are the three main functional parts of the mass spectrometer described?

    1. A

      A carrier tank, a syringe, and a chromatogram

    2. B

      An injector, a column, and an oven

    3. C

      A solvent reservoir, a pump, and a separator

    4. D

      An ionizer, a mass filter, and a detector

    Correct answer
    D

    An ionizer, a mass filter, and a detector

    Explanation

    The mass spectrometer contains an ionizer, a mass filter or analyzer, and a detector.

  22. 22

    What happens to neutral compounds in the ionizer during electron-impact ionization?

    1. A

      A beam of light converts the compounds into neutral gases

    2. B

      A magnetic field removes all atoms from the compounds

    3. C

      A beam of electrons knocks electrons away and forms positive ions

    4. D

      A beam of protons adds electrons and forms negative ions

    Correct answer
    C

    A beam of electrons knocks electrons away and forms positive ions

    Explanation

    Electron impact removes electrons from neutral molecules; because electrons are negatively charged, the resulting molecular ions are positively charged.

  23. 23

    How does a quadrupole mass filter separate ions?

    1. A

      Different solvents dissolve ions according to their boiling points

    2. B

      Rapidly changing voltages guide ions according to their mass-to-charge ratios

    3. C

      A stationary phase traps every ion permanently

    4. D

      A heated column separates ions according to their color

    Correct answer
    B

    Rapidly changing voltages guide ions according to their mass-to-charge ratios

    Explanation

    A quadrupole uses four rods with alternating and rapidly changing voltages to transmit ions according to their mass-to-charge ratios.

  24. 24

    What occurs when an ion reaches the mass spectrometer detector?

    1. A

      It is converted into a visible precipitate

    2. B

      It is separated into a new chromatographic column

    3. C

      It strikes a plate and produces an electrical signal

    4. D

      It dissolves in solvent and becomes neutral again

    Correct answer
    C

    It strikes a plate and produces an electrical signal

    Explanation

    Ions striking the detector plate generate an electrical signal that is sent to the data system.

  25. 25

    What does a chromatogram display in a GC-MS analysis?

    1. A

      Only the chemical formula of the carrier gas

    2. B

      The number of neutrons in every sample molecule

    3. C

      The voltage applied to the laboratory power supply

    4. D

      Detector response as compounds elute over time

    Correct answer
    D

    Detector response as compounds elute over time

    Explanation

    A chromatogram shows signals for compounds as they leave the GC column, typically plotted against acquisition or retention time.

  26. 26

    What does a mass spectrum associated with one chromatographic peak represent?

    1. A

      The amount of carrier gas remaining in the cylinder

    2. B

      All compounds injected during the entire experiment combined equally

    3. C

      The ions produced from one compound at a particular elution time

    4. D

      Only the temperature history of the GC oven

    Correct answer
    C

    The ions produced from one compound at a particular elution time

    Explanation

    The mass spectrum associated with a peak represents the mass-to-charge ratios and intensities of ions from the compound eluting at that time.

  27. 27

    Why must compounds be dissolved before injection into the GC?

    1. A

      The sample must be in a solution that can be injected and vaporized

    2. B

      The detector can measure only undissolved solid particles

    3. C

      Dissolution prevents the carrier gas from moving through the column

    4. D

      Dissolution guarantees that every compound becomes nonvolatile

    Correct answer
    A

    The sample must be in a solution that can be injected and vaporized

    Explanation

    GC samples must be soluble in a suitable solvent so they can be introduced through the syringe and vaporized in the injector.

  28. 28

    Which solvent combination was identified as suitable for GC sample preparation?

    1. A

      Hexane and dichloromethane

    2. B

      Glycerol and ethylene glycol

    3. C

      Sulfuric acid and ammonia

    4. D

      Water and sodium chloride

    Correct answer
    A

    Hexane and dichloromethane

    Explanation

    Hexane and dichloromethane were given as examples of volatile organic solvents used for GC samples.

  29. 29

    How do hexane and dichloromethane differ in polarity?

    1. A

      Both hexane and dichloromethane are strongly ionic

    2. B

      Both hexane and dichloromethane are aqueous solvents

    3. C

      Hexane is nonpolar, whereas dichloromethane is polar

    4. D

      Hexane is polar, whereas dichloromethane is nonpolar

    Correct answer
    C

    Hexane is nonpolar, whereas dichloromethane is polar

    Explanation

    Hexane was described as a nonpolar solvent, while dichloromethane was described as a polar solvent.

  30. 30

    Why should water generally not be used as a GC solvent?

    1. A

      It cannot be drawn into a syringe because it has no mass

    2. B

      It is too volatile to enter the injector port

    3. C

      It can condense in the column and later vaporize in a way that overloads the column

    4. D

      It reacts instantly with helium to form a solid

    Correct answer
    C

    It can condense in the column and later vaporize in a way that overloads the column

    Explanation

    Water boils at 100 ∘C100\,^{\circ}\mathrm{C}100∘C. In the cooler part of the column it can remain liquid, then vaporize and occupy much of the column, making it unsuitable for routine GC use.

  31. 31

    Why do hexane and dichloromethane leave the GC column relatively quickly?

    1. A

      They have unusually strong interactions with the stationary phase

    2. B

      They boil at lower temperatures and vaporize readily

    3. C

      They are chemically converted into helium inside the oven

    4. D

      They are solids that move rapidly along the column

    Correct answer
    B

    They boil at lower temperatures and vaporize readily

    Explanation

    Their relatively low boiling points allow them to vaporize and pass through the column without requiring high temperatures.

  32. 32

    What approximate sensitivity range was given for the electron-impact instrument per component?

    1. A

      About 111 to 100100100 liters

    2. B

      About 111 to 100100100 picograms

    3. C

      About 111 to 100100100 moles

    4. D

      About 111 to 100100100 kilograms

    Correct answer
    B

    About 111 to 100100100 picograms

    Explanation

    The instrument's sensitivity was described as approximately 111 to 100100100 picograms per component for the electron-impact method.

  33. 33

    What is the approximate liquid injection volume used by the instrument?

    1. A

      1 L1\,\mathrm{L}1L

    2. B

      1 μL1\,\mu\mathrm{L}1μL

    3. C

      1 mL1\,\mathrm{mL}1mL

    4. D

      100 mL100\,\mathrm{mL}100mL

    Correct answer
    B

    1 μL1\,\mu\mathrm{L}1μL

    Explanation

    The injection amount was identified as approximately 1 μL1\,\mu\mathrm{L}1μL, an extremely small liquid volume.

  34. 34

    Why is extensive dilution often recommended before GC-MS analysis?

    1. A

      Dilution makes every compound permanently nonvolatile

    2. B

      The instrument cannot detect samples containing any solvent

    3. C

      Dilution prevents compounds from entering the carrier-gas stream

    4. D

      The instrument is sensitive enough that concentrated samples may overload it

    Correct answer
    D

    The instrument is sensitive enough that concentrated samples may overload it

    Explanation

    Because the instrument can detect extremely small quantities, samples may need to be diluted repeatedly to avoid introducing too much material.

  35. 35

    What is the main purpose of sample cleanup before GC-MS analysis?

    1. A

      To prevent the compound of interest from dissolving in solvent

    2. B

      To add as much dirt and interfering material as possible

    3. C

      To remove matrix components while concentrating the compound of interest

    4. D

      To convert every sample component into the same chemical

    Correct answer
    C

    To remove matrix components while concentrating the compound of interest

    Explanation

    Cleanup removes unwanted matrix material and helps place a greater proportion of the target compound into the instrument.

  36. 36

    How does liquid–liquid extraction separate compounds?

    1. A

      A compound partitions between two immiscible liquid phases

    2. B

      A compound is separated by melting every phase into one liquid

    3. C

      A compound is separated only by its electrical charge in a vacuum

    4. D

      A compound is permanently attached to a solid detector plate

    Correct answer
    A

    A compound partitions between two immiscible liquid phases

    Explanation

    Liquid–liquid extraction uses two immiscible liquids, such as water and an organic solvent, so compounds can be transferred preferentially into one phase.

  37. 37

    What happens during solid-phase extraction?

    1. A

      A sample passes through a modified solid phase that retains some matrix components

    2. B

      A sample is injected directly into the mass filter without cleanup

    3. C

      A sample is mixed with water until every component becomes gaseous

    4. D

      A sample is boiled until all compounds decompose

    Correct answer
    A

    A sample passes through a modified solid phase that retains some matrix components

    Explanation

    In solid-phase extraction, the sample passes through a modified solid material, often silica-based, that can retain matrix components while soluble target compounds pass through.

  38. 38

    In a solid-phase extraction setup, what is the intended fate of insoluble dirt in the sample?

    1. A

      It increases the amount of matrix entering the mass spectrometer

    2. B

      It evaporates before the sample reaches the solid phase

    3. C

      It remains in the solid-phase tube while soluble components pass through

    4. D

      It is converted into ions and measured as the target compound

    Correct answer
    C

    It remains in the solid-phase tube while soluble components pass through

    Explanation

    The solid phase can retain dirt and other matrix material, allowing soluble components to pass through for collection.

  39. 39

    How does qualitative GC-MS analysis differ from quantitative GC-MS analysis?

    1. A

      Qualitative analysis measures temperature, whereas quantitative analysis measures pressure only

    2. B

      Qualitative analysis identifies properties or compounds, whereas quantitative analysis determines amounts

    3. C

      Qualitative analysis requires no instrument, whereas quantitative analysis requires only a balance

    4. D

      Qualitative analysis determines amounts, whereas quantitative analysis identifies only colors

    Correct answer
    B

    Qualitative analysis identifies properties or compounds, whereas quantitative analysis determines amounts

    Explanation

    Qualitative analysis focuses on what is present, while quantitative analysis focuses on how much is present.

  40. 40

    What is retention time?

    1. A

      The duration needed to ionize the entire sample before injection

    2. B

      The time required to fill the carrier-gas cylinder

    3. C

      The time required to clean the outside of the instrument

    4. D

      The time at which a compound elutes from the GC column

    Correct answer
    D

    The time at which a compound elutes from the GC column

    Explanation

    Retention time is the time at which a compound emerges from the GC column and produces a chromatographic signal.

  41. 41

    How can a known standard help identify an unknown compound by GC?

    1. A

      A standard identifies compounds solely by the color of their solutions

    2. B

      A standard guarantees that every unknown has the same molecular formula

    3. C

      Matching retention times under unchanged conditions supports the same identity

    4. D

      A standard eliminates the need for chromatographic separation

    Correct answer
    C

    Matching retention times under unchanged conditions supports the same identity

    Explanation

    If a standard and an unknown produce the same or very similar retention time under the same GC conditions, the unknown may contain the same compound.

  42. 42

    Why must the GC method remain unchanged when comparing an unknown with a standard?

    1. A

      Retention times depend on the chromatographic conditions

    2. B

      The carrier gas becomes reactive whenever a standard is injected

    3. C

      The detector can measure only samples prepared on the same day

    4. D

      Mass spectra disappear whenever the oven temperature changes

    Correct answer
    A

    Retention times depend on the chromatographic conditions

    Explanation

    Retention times are meaningful for comparison when conditions such as the column and temperature program remain the same.

  43. 43

    How can a mass spectral database help identify a compound?

    1. A

      The database replaces the need to ionize compounds

    2. B

      The database determines the sample's boiling point from its color

    3. C

      The database directly measures the sample's liquid volume

    4. D

      The sample spectrum can be matched with a reference fragmentation pattern

    Correct answer
    D

    The sample spectrum can be matched with a reference fragmentation pattern

    Explanation

    A reference database provides mass spectra that can be compared with the sample's ion pattern.

  44. 44

    Why is electron-impact fragmentation useful for identifying compounds?

    1. A

      It prevents molecules from forming ions

    2. B

      It tends to produce a characteristic fragmentation pattern for a compound

    3. C

      It produces exactly the same pattern for every compound

    4. D

      It measures only the sample's retention time

    Correct answer
    B

    It tends to produce a characteristic fragmentation pattern for a compound

    Explanation

    Electron-impact fragmentation produces characteristic ions and relative intensities that can serve as a molecular fingerprint.

  45. 45

    Why can two different compounds sometimes have similar mass spectra?

    1. A

      The detector measures only solvent molecules

    2. B

      The mass spectrometer always assigns the same mass to every molecule

    3. C

      The GC column forces all compounds to have identical structures

    4. D

      Different structures can fragment into overlapping sets of ions

    Correct answer
    D

    Different structures can fragment into overlapping sets of ions

    Explanation

    Some compounds, including certain hydrocarbons or stereoisomers, can produce similar or even indistinguishable mass spectral patterns.

  46. 46

    How can GC-MS distinguish compounds with similar mass spectra?

    1. A

      The GC may separate them by different retention times before MS detection

    2. B

      The data system identifies them only from sample color

    3. C

      The carrier gas gives each compound a different electrical charge permanently

    4. D

      The injector changes their molecular formulas into unique solvents

    Correct answer
    A

    The GC may separate them by different retention times before MS detection

    Explanation

    Gas chromatography can separate compounds according to boiling point or column interactions, providing retention-time information that complements the mass spectrum.

  47. 47

    What structural information can a characteristic loss of 181818 mass units suggest?

    1. A

      It proves that the molecule is composed only of helium

    2. B

      It can indicate loss involving hydrogen and oxygen, such as a hydroxyl-related fragment

    3. C

      It shows that the compound has no heteroatoms

    4. D

      It proves that the molecule contains exactly 181818 carbon atoms

    Correct answer
    B

    It can indicate loss involving hydrogen and oxygen, such as a hydroxyl-related fragment

    Explanation

    A loss of 181818 mass units can be associated with the loss of a fragment involving hydrogen and oxygen and may provide structural information during spectrum interpretation.

  48. 48

    What did the two CBD-related chromatographic peaks suggest?

    1. A

      The sample may contain two CBD components with different GC behavior

    2. B

      The mass spectrometer had failed to detect any compounds

    3. C

      The sample contained only solvent and no cannabinoid material

    4. D

      The two peaks necessarily represented identical molecules in identical environments

    Correct answer
    A

    The sample may contain two CBD components with different GC behavior

    Explanation

    Two peaks had similar CBD mass spectra but different retention times, suggesting two CBD-related components; an additional standard would be needed for complete confirmation.

  49. 49

    Why did the purchased CBD sample have more chromatographic peaks than the CBD standard?

    1. A

      The mass spectrometer always produces extra peaks for pure substances

    2. B

      The GC column created new compounds from the carrier gas

    3. C

      The natural-product sample contained additional components besides CBD

    4. D

      The standard necessarily contained more impurities than the purchased sample

    Correct answer
    C

    The natural-product sample contained additional components besides CBD

    Explanation

    CBD is one component of the cannabis plant, so a natural-product sample can contain other compounds that produce additional peaks.

  50. 50

    What additional compound was identified in the CBD sample?

    1. A

      Tetrahydrocannabinol, or THC

    2. B

      Salicylic acid

    3. C

      Dichloromethane

    4. D

      Octane

    Correct answer
    A

    Tetrahydrocannabinol, or THC

    Explanation

    The later peak in the CBD sample was identified as THC by its mass spectral information.

  51. 51

    What was the purpose of analyzing a salicylic-acid standard in the aspirin experiment?

    1. A

      To establish a reference retention time and mass spectrum

    2. B

      To prevent salicylic acid from entering the instrument

    3. C

      To convert aspirin into a carrier gas

    4. D

      To determine the boiling point of water in the injector

    Correct answer
    A

    To establish a reference retention time and mass spectrum

    Explanation

    A salicylic-acid standard provides reference chromatographic and mass spectral data for comparison with an unknown sample.

  52. 52

    What is the function of stormwater retention ponds?

    1. A

      They convert petroleum leaks into harmless gases

    2. B

      They immediately pipe all stormwater directly into rivers

    3. C

      They permanently evaporate all water from impervious surfaces

    4. D

      They temporarily store stormwater and allow it to soak into the ground more naturally

    Correct answer
    D

    They temporarily store stormwater and allow it to soak into the ground more naturally

    Explanation

    Retention ponds temporarily hold stormwater and promote more natural infiltration, helping reduce rapid runoff and flash flooding.

  53. 53

    Why might retention ponds near parking lots become possible pollution point sources?

    1. A

      Parking lots chemically transform water into gasoline

    2. B

      Runoff can carry petroleum leaked from vehicles into the ponds

    3. C

      Ponds generate petroleum whenever the water level rises

    4. D

      Stormwater prevents all contaminants from leaving paved surfaces

    Correct answer
    B

    Runoff can carry petroleum leaked from vehicles into the ponds

    Explanation

    Impervious parking-lot surfaces can collect petroleum from vehicle leaks, and rain can transport that material into nearby retention ponds.

  54. 54

    Why is pond-water extraction concentrated from nearly a liter to roughly a milliliter?

    1. A

      Concentration increases the target compounds' amount per unit volume for detection

    2. B

      Concentration removes the need for a mass spectrometer

    3. C

      Concentration ensures that water remains in the GC column

    4. D

      Concentration makes all compounds nonvolatile before injection

    Correct answer
    A

    Concentration increases the target compounds' amount per unit volume for detection

    Explanation

    Because pollutants may be present at very low levels, reducing a large sample to a much smaller volume concentrates them and improves detectability.

  55. 55

    In the pond-water method, why might dichloromethane be found beneath hexane in a separatory funnel?

    1. A

      Dichloromethane is always aqueous while hexane is ionic

    2. B

      Dichloromethane is less dense than hexane

    3. C

      Dichloromethane is denser than hexane

    4. D

      Dichloromethane cannot form a separate liquid layer

    Correct answer
    C

    Dichloromethane is denser than hexane

    Explanation

    Dichloromethane is denser than hexane, so it forms the lower organic layer when the two are used together.

  56. 56

    What is a deuterated standard?

    1. A

      A compound containing deuterium, a hydrogen isotope with extra neutrons

    2. B

      A solvent made entirely from helium isotopes

    3. C

      A compound whose carbon atoms have been removed

    4. D

      A compound containing no hydrogen atoms at all

    Correct answer
    A

    A compound containing deuterium, a hydrogen isotope with extra neutrons

    Explanation

    Deuterium is a hydrogen isotope with one proton and additional neutrons, making the isotope approximately one atomic mass unit heavier per substituted hydrogen.

  57. 57

    Why was a deuterated octane standard useful in pond-water analysis?

    1. A

      The mass spectrometer could distinguish it from ordinary octane by mass-to-charge ratio

    2. B

      The GC gave it a completely different retention time from ordinary octane

    3. C

      It made octane soluble only in water

    4. D

      It prevented all petroleum compounds from entering the extraction

    Correct answer
    A

    The mass spectrometer could distinguish it from ordinary octane by mass-to-charge ratio

    Explanation

    Deuterated octane has a higher mass because of its deuterium atoms. The GC may give the two forms the same retention time, but the MS can distinguish their mass-to-charge ratios.

  58. 58

    How can a known amount of spiked deuterated standard help evaluate an extraction?

    1. A

      It eliminates the need to perform liquid–liquid extraction

    2. B

      It changes every unknown pollutant into octane

    3. C

      Its recovered peak area can be compared with the known amount added

    4. D

      It guarantees that no laboratory contamination occurred

    Correct answer
    C

    Its recovered peak area can be compared with the known amount added

    Explanation

    Because the amount of standard added is known, its recovered signal can help assess extraction recovery and support normalization of results.

  59. 59

    What laboratory problem interfered with the pond-water analysis?

    1. A

      The deuterated standard evaporated before it was prepared

    2. B

      The GC column was unable to separate any organic compounds

    3. C

      The pond water contained too much helium to analyze

    4. D

      Laboratory contamination made it difficult to obtain reliable results

    Correct answer
    D

    Laboratory contamination made it difficult to obtain reliable results

    Explanation

    The project experienced difficulties caused by laboratory contamination, which complicated interpretation of the results.

  60. 60

    What would a purge-and-trap system improve in the pond-water method?

    1. A

      It would convert the GC into an infrared spectrometer

    2. B

      It would eliminate the need for a carrier gas by using water instead

    3. C

      It would perform extraction and injection while reducing contamination points

    4. D

      It would identify compounds without producing any mass spectrum

    Correct answer
    C

    It would perform extraction and injection while reducing contamination points

    Explanation

    A purge-and-trap system can automate extraction and injection, reducing the number of handling steps where contamination may occur.

  61. 61

    Which additional analysis was identified as a suitable GC project?

    1. A

      Determining the color of water without injecting a sample

    2. B

      Measuring alcohols such as ethanol produced during fermentation

    3. C

      Measuring the mass of rocks without vaporizing them

    4. D

      Measuring only the pressure inside the carrier-gas cylinder

    Correct answer
    B

    Measuring alcohols such as ethanol produced during fermentation

    Explanation

    A GC method can be used to analyze various alcohols, making ethanol produced by fermentation a suitable project.

Question 1 of 61
Question 1 of 61

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent