Gas Chromatography Mass Spectrometry
- 91Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
91 questions
- 1GC-MS is an analytical method that combines gas chromatography with_____to identify substances in a sample.
Hint
The second technique detects ions according to their mass-to-charge ratios.
Answer
mass spectrometry
- 2Analytical chemistry uses instruments and methods to separate, identify, and_____matter.
Hint
This means determining how much of a substance is present.
Answer
quantify
- 3The identification of which compounds are present in a sample is called_____analysis.
Hint
This type of analysis addresses identity rather than amount.
Answer
qualitative
- 4Gas chromatography is used to separate and analyze compounds that can be vaporized without_____.
Hint
The compounds must become gases while remaining chemically intact.
Answer
decomposition
- 5A compound that cannot be converted into a gas at the instrument's operating temperatures is generally_____for GC-MS analysis.
Hint
GC requires compounds to become volatile.
Answer
unsuitable
- 6Mass spectrometry detects and measures the_____ratio of ions.
Hint
This ratio compares an ion's mass with its electrical charge.
Answer
mass-to-charge
- 7Because GC-MS combines two analytical techniques into one method, it is called a_____analytical technique.
Hint
The name refers to techniques joined together.
Answer
hyphenated
- 8In GC-MS, the GC portion primarily handles_____organic compounds.
Hint
These compounds readily enter the gas phase.
Answer
volatile
- 9The mass spectrometer functions primarily as the GC-MS_____.
Hint
It detects the compounds after they have been separated by the GC.
Answer
detector
- 10A major reason for careful GC-MS sample preparation is that the instrument can detect amounts in the_____range.
Hint
The prefix refers to an extremely small quantity.
Answer
femtomolar
- 11The carrier gas in the described GC-MS system is_____.
Hint
It is an inert noble gas stored in a tank.
Answer
helium
- 12The carrier gas is considered a_____phase because it moves through the chromatographic system.
Hint
Its name describes its movement.
Answer
mobile
- 13The carrier gas connects to the injector, the injector connects to the GC column, and the column connects to the_____.
Hint
This component receives compounds after chromatographic separation.
Answer
mass spectrometer
- 14Carrier gases used in GC are usually chemically_____so that they do not react with the sample.
Hint
An inert substance is not chemically reactive under the operating conditions.
Answer
inert
- 15Besides helium, another commonly used inert carrier gas is_____.
Hint
It is a major component of air and is not the flammable option discussed.
Answer
nitrogen
- 16Hydrogen is sometimes used as a carrier gas because it is less expensive, but it presents a_____hazard.
Hint
Hydrogen can burn readily.
Answer
flammability
- 17The injector introduces the sample into the flow of the_____gas.
Hint
This gas transports the sample through the system.
Answer
carrier
- 18The injector port converts the sample into a gas using_____temperature.
Hint
The port is heated to promote vaporization.
Answer
high
- 19The injection ports in the described system operate at approximately_____degrees Celsius.
Hint
This temperature is above the boiling point of water.
Answer
120
- 20The GC column is housed inside a temperature-controlled_____.
Hint
This part gradually heats the column during the separation.
Answer
oven
- 21The GC oven in the described instrument can operate from approximately 40 to_____degrees Celsius.
Hint
This is the upper end of the stated temperature range.
Answer
350
- 22The GC-MS data system displays both a chromatogram and a_____.
Hint
One display shows ions from a compound at a particular time.
Answer
mass spectrum
- 23The GC column is a_____phase that retains compounds according to their interactions with it.
Hint
Unlike the carrier gas, this phase remains in place.
Answer
stationary
- 24The GC column separates a mixture as a result of the column and controlled_____.
Hint
The oven gradually raises the temperature during the run.
Answer
heat
- 25GC columns in the described system are generally about 15 to_____meters long.
Hint
This is the upper end of the stated column-length range.
Answer
60
- 26A longer GC column generally provides more theoretical_____for separation.
Hint
This chromatographic term describes separation efficiency.
Answer
plates
- 27Compounds with larger molecular weights or stronger interactions with the column generally move through it more_____.
Hint
Greater resistance to movement delays elution.
Answer
slowly
- 28A compound that interacts strongly with the GC column will usually elute_____than a compound with weaker interactions.
Hint
Strong retention increases the time before the compound exits.
Answer
later
- 29The time at which a compound exits the GC column is called its_____time.
Hint
This measurement is used to compare compounds under the same GC conditions.
Answer
retention
- 30In a chromatogram, the first compounds to appear have shorter_____times than compounds that emerge later.
Hint
The missing term is part of the phrase used for elution timing.
Answer
retention
- 31Chromatographic separation allows compounds in a mixture to emerge from the column at different_____.
Hint
The chromatogram plots signal against acquisition time.
Answer
times
- 32Under unchanged GC conditions, a compound will elute at the same or a very similar_____time.
Hint
This property is compared between a standard and an unknown.
Answer
retention
- 33In the river analogy for a GC column, the carrier gas is compared with flowing_____.
Hint
The analogy involves a river carrying a raft past obstacles.
Answer
water
- 34The first major section of the mass spectrometer creates ions from neutral compounds and is called the_____.
Hint
Its function is to produce charged particles.
Answer
ionizer
- 35In the described ionization method, compounds pass through a beam of_____.
Hint
These negatively charged particles interact with the sample molecules.
Answer
electrons
- 36Removing an electron from a neutral compound produces an ion with a_____charge.
Hint
An electron has a negative charge, so removing one leaves a relative excess of positive charge.
Answer
positive
- 37The mass spectrometer component that filters ions according to their mass-to-charge ratios is the mass_____.
Hint
It selects which ions pass through to the detector.
Answer
filter
- 38The quadrupole mass filter contains_____rods.
Hint
The prefix in its name refers to this number.
Answer
four
- 39In a quadrupole, rapidly alternating voltages cause ions to be_____through the rod region according to their behavior.
Hint
Only ions with appropriate trajectories reach the next component.
Answer
filtered
- 40A scanned DC voltage in the mass analyzer allows the instrument to determine the ion's_____ratio.
Hint
This is the central measurement made by mass spectrometry.
Answer
mass-to-charge
- 41For a water ion with mass 18 and a charge of 1, the measured mass-to-charge ratio is_____.
Hint
Divide the mass by the charge.
Answer
18
- 42The final major component of the mass spectrometer is the_____.
Hint
It receives ions after the mass filter.
Answer
detector
- 43When ions strike the detector plate, they produce an_____signal.
Hint
The detector converts ion impacts into a measurable signal.
Answer
electrical
- 44A mass spectrum shows the different_____produced from one compound that entered the instrument at a particular time.
Hint
These are charged fragments or molecular ions represented by mass-to-charge values.
Answer
ions
- 45The GC-MS data system receives the detector's electrical signal and_____the data.
Hint
The system does more than simply collect the signal.
Answer
analyzes
- 46For GC-MS analysis, compounds must be sufficiently_____to enter the gas chromatograph.
Hint
They must be able to become gases during injection and separation.
Answer
volatile
- 47Before injection, compounds must be_____in a suitable solution.
Hint
The sample must form a solution rather than remain undissolved.
Answer
soluble
- 48The solvent used for GC injection should generally be a volatile_____solvent.
Hint
The presentation gives hexane and dichloromethane as examples.
Answer
organic
- 49Hexane is classified as a_____solvent.
Hint
It is contrasted with polar dichloromethane.
Answer
nonpolar
- 50Dichloromethane is classified as a_____solvent.
Hint
It is contrasted with nonpolar hexane.
Answer
polar
- 51Water should not normally be used as a GC solvent because its boiling point is_____degrees Celsius.
Hint
This is the familiar boiling point of water at standard pressure.
Answer
100
- 52The approximate sensitivity of the electron-impact instrument is one to one hundred_____per component.
Hint
This is a very small mass unit.
Answer
picograms
- 53The typical GC-MS injection volume described is_____microliter.
Hint
The volume is so small that it does not have enough weight to fall from the syringe.
Answer
one
- 54A simple sample-preparation method may involve dissolving the sample in a suitable_____.
Hint
This liquid allows the sample to be injected into the instrument.
Answer
solvent
- 55In liquid-liquid extraction, compounds are transferred between two immiscible_____phases.
Hint
The method uses layers such as water and hexane.
Answer
liquid
- 56In solid-phase extraction, the sample passes through a_____phase that retains some matrix components.
Hint
The material is contained in a tube and may resemble sand.
Answer
solid
- 57A major purpose of extraction cleanup is to remove the sample_____while concentrating the compound of interest.
Hint
This refers to unwanted material surrounding the analyte.
Answer
matrix
- 58Qualitative data describe the properties or_____of a sample rather than its amount.
Hint
These characteristics help indicate what is present.
Answer
attributes
- 59A chromatogram provides the_____time used to help identify a compound.
Hint
This is the time at which the compound exits the GC column.
Answer
retention
- 60The characteristic pattern of fragments in a mass spectrum is called a_____pattern.
Hint
It results from the molecule breaking into charged pieces.
Answer
fragmentation
- 61To identify an unknown using retention time, an analyst injects a known_____under the same GC conditions.
Hint
It provides a reference retention time for comparison.
Answer
standard
- 62An unknown compound that elutes at the same retention time as a salicylic acid standard can probably be identified as_____.
Hint
The unknown is being compared with a standard of the same compound.
Answer
salicylic acid
- 63A mass spectrum of an unknown can be compared with a reference spectrum in a spectral_____.
Hint
The presentation describes using the NIST WebBook for this purpose.
Answer
database
- 64GC fragmentation is described as highly_____for a given compound.
Hint
The same compound tends to produce the same pattern repeatedly.
Answer
specific
- 65The salicylic acid spectrum discussed included prominent mass-to-charge values of 138, 120, and_____.
Hint
This is the third value in the reported series.
Answer
92
- 66If no spectral database is available, an analyst must interpret the mass spectrum or use a known_____.
Hint
This is a previously identified reference material.
Answer
standard
- 67The two main identification tools in the presentation are retention time and the mass spectral_____.
Hint
This describes the distribution of fragment ions.
Answer
pattern
- 68The CBD standard in the described chromatogram eluted at approximately_____minutes.
Hint
This value was used as the known standard's retention time.
Answer
14.54
- 69A CBD sample purchased as a natural product contained more chromatographic_____than the CBD standard.
Hint
Each peak can represent a component separated by the GC.
Answer
peaks
- 70The additional compound identified at the back of the CBD chromatogram was_____.
Hint
It is another cannabinoid associated with cannabis.
Answer
THC
- 71The second CBD-related peak in the sample appeared at approximately_____minutes.
Hint
It eluted before the standard peak at 14.54 minutes.
Answer
13.96
- 72The two CBD components could be separated chromatographically because they have different interactions with the column or different_____points.
Hint
Compounds with different volatility may elute at different times.
Answer
boiling
- 73Compounds with chiral centers that are mirror-image forms are called_____.
Hint
These stereoisomers are non-superimposable mirror images.
Answer
enantiomers
- 74The two CBD structures shown differed in the orientation of a solid or dashed_____at a chiral center.
Hint
This drawing convention indicates whether a group projects toward or away from the viewer.
Answer
wedge
- 75The mass spectrometer alone could not distinguish the two similar CBD stereoisomers, but the GC separated them by their different_____times.
Hint
This refers to when compounds leave the chromatographic column.
Answer
elution
- 76Stormwater retention ponds temporarily store stormwater and allow it to_____into the ground more naturally.
Hint
This process is an alternative to immediately piping water away.
Answer
soak
- 77Storm drains that pipe water directly to rivers can contribute to_____flooding.
Hint
This type of flooding occurs rapidly after intense rainfall.
Answer
flash
- 78Parking lots are described as_____surfaces because water cannot easily infiltrate them.
Hint
The term means resistant to the passage of water.
Answer
impervious
- 79Petroleum leaking from vehicles on parking lots may make retention ponds potential point sources for_____.
Hint
The ponds could receive identifiable contaminants from runoff.
Answer
pollution
- 80The retention-pond water method described uses_____extraction to isolate organic compounds.
Hint
The method partitions compounds between water and an organic solvent.
Answer
liquid-liquid
- 81In the pond-water extraction, dichloromethane forms the bottom layer because it is more_____than water.
Hint
The denser liquid settles below the less dense layer.
Answer
dense
- 82The pond-water extraction concentrates nearly a liter of sample down to approximately one_____.
Hint
This greatly reduces the volume while retaining extracted compounds.
Answer
milliliter
- 83A deuterated standard contains hydrogen isotopes with additional_____in their nuclei.
Hint
Isotopes of the same element differ in this nuclear particle.
Answer
neutrons
- 84The deuterated compound used as a standard for gasoline-type contaminants was_____.
Hint
It is a hydrocarbon associated with gasoline.
Answer
octane
- 85The GC could not distinguish ordinary octane from its deuterated form by retention time, but the mass spectrometer could distinguish them by their mass-to-charge_____.
Hint
The added deuterium changes the measured ion masses.
Answer
ratios
- 86A deuterated standard can be used to calculate recovery by comparing peak_____after extraction.
Hint
The size of a chromatographic signal is measured using this quantity.
Answer
areas
- 87A purge-and-trap instrument would reduce laboratory contamination because it performs the extraction and_____the sample into the GC-MS.
Hint
The instrument would automatically introduce the extracted sample.
Answer
injects
- 88GC-MS can be adapted to measure ethanol produced by_____.
Hint
This biological process can produce alcohols.
Answer
fermentation
- 89Hydrocarbons tend to fragment according to the number of_____atoms they contain.
Hint
This element forms the framework of hydrocarbon molecules.
Answer
carbon
- 90Successive hydrocarbon fragment groups may be separated by approximately 14_____in the mass spectrum.
Hint
This unit expresses a difference in molecular mass.
Answer
daltons
- 91A loss of 18 mass units from a fragment can indicate the loss of a hydroxyl-related combination of hydrogen and_____.
Hint
The hydroxyl group contains this element.
Answer
oxygen

Ask anything
We've read this whole study set, so questions about it get the best answers.