Gas Chromatography Mass Spectrometry

  • 94Unfamiliar
  • 0Learning
  • 0Familiar
  • 0Mastered
Topic: GC-MS Fundamentals
  • spaceFlip card
  • KI knew it
  • DI didn't know it
  • ←Previous card
  • →Next card

What is gas chromatography–mass spectrometry (GC–MS)?

Tap to flipClick to flipspace

An analytical method that combines gas chromatography and mass spectrometry to identify substances in a sample.

Or swipe the card

94 cards

  1. What is gas chromatography–mass spectrometry (GC–MS)?

    An analytical method that combines gas chromatography and mass spectrometry to identify substances in a sample.

  2. What is analytical chemistry concerned with?

    Separating, identifying, and quantifying matter using instruments and methods.

  3. What does qualitative analysis determine?

    The properties, attributes, or identities of substances present in a sample.

  4. What does quantitative analysis determine?

    The amount or concentration of a substance in a sample.

  5. Why is GC–MS called a hyphenated analytical technique?

    Because it combines two analytical techniques—gas chromatography and mass spectrometry—into one method.

  6. What type of compounds is gas chromatography generally used to analyze?

    Volatile compounds that can be vaporized without decomposing.

  7. What is the approximate usable temperature range mentioned for vaporizing GC samples?

    Approximately 120 to 300 degrees Celsius.

  8. What does mass spectrometry measure?

    The mass-to-charge ratio of ions.

  9. Why is proper sample preparation especially important for GC–MS?

    The instrument is highly sensitive and can detect extremely small amounts of sample, including femtomolar amounts in some contexts.

  10. What are the four overall functions in a GC–MS analysis?

    The carrier gas moves the sample, the GC separates the mixture, the MS detects compounds, and the data system collects and analyzes the data.

  11. What is the carrier gas in the described GC–MS system?

    Helium.

  12. What is the mobile phase in gas chromatography?

    The moving phase that carries compounds through the system.

  13. What properties should a GC carrier gas have?

    It should be inert and nonreactive with the compounds or chemicals in the system.

  14. Which gases are commonly used as GC carrier gases?

    Helium and nitrogen; hydrogen may also be used in some systems.

  15. Why was hydrogen not used in the described GC–MS system?

    Because hydrogen is flammable.

  16. What does the injector port do?

    It injects the sample into the flow of carrier gas and onto the GC column.

  17. How does the injector port vaporize the sample?

    It exposes the sample to high temperature, typically around 120 degrees Celsius, converting it into a gas.

  18. What additional sample-preparation function can occur at the injection port?

    The sample can be diluted within the instrument.

  19. What is the function of the GC column oven?

    It heats the column gradually to help separate the compounds.

  20. What are the three main parts of the mass spectrometer?

    The ionizer, mass filter or analyzer, and detector.

  21. What is the role of the data system in GC–MS?

    It collects and analyzes the detector signal, displaying chromatograms and mass spectra.

  22. What is the purpose of an autosampler in a GC–MS system?

    It automatically transfers samples to the injection port for analysis.

  23. How does gas chromatography separate compounds?

    Compounds move through a heated column at different rates because of differences in their interactions with the column and their volatility.

  24. What is the stationary phase in gas chromatography?

    The GC column, which retains compounds according to how strongly they interact with it.

  25. How does gradually heating the GC column affect separation?

    It causes compounds that move slowly to vaporize and travel more quickly through the column.

  26. Why do compounds with stronger interactions with the GC column elute later?

    They are retained by the stationary phase for longer periods.

  27. How does molecular size or molecular weight generally affect movement through the GC column?

    Compounds with larger molecular weight may move more slowly and require heating to move more quickly.

  28. What is the typical length range of the GC columns described?

    Approximately 15 to 60 meters.

  29. What is the significance of GC column length?

    A longer column provides more theoretical plates and can improve separation.

  30. What is retention time?

    The time at which a compound elutes from the GC column and reaches the detector.

  31. What does an early peak in a GC chromatogram indicate?

    That the corresponding compound eluted from the column relatively early.

  32. What does a late peak in a GC chromatogram generally indicate?

    That the compound had stronger or more extensive interactions with the column.

  33. What does the chromatogram display?

    The detector response or counts as a function of acquisition time, showing when compounds elute.

  34. What happens to neutral compounds when they enter the mass spectrometer's ionizer?

    They pass through an electron beam that knocks out an electron and converts them into positively charged ions.

  35. What is the purpose of the ionizer?

    To create ions from neutral compounds exiting the GC.

  36. What ionization method is used in the described instrument?

    Electron impact ionization.

  37. What is a quadrupole mass filter?

    A mass analyzer consisting of four rods with alternating electrical voltages that filter ions according to mass-to-charge ratio.

  38. How do the rods in a quadrupole filter ions?

    Rapidly alternating positive and negative voltages cause ions with selected mass-to-charge ratios to pass through while other ions are displaced.

  39. Why is the quadrupole also called a mass analyzer?

    Because it separates or filters ions according to their mass-to-charge ratios.

  40. What does scanning the quadrupole voltage accomplish?

    It allows the instrument to measure different mass-to-charge ratios.

  41. What mass-to-charge ratio would water produce if its mass is 18 and its charge is 1?

    A mass-to-charge ratio of 18.

  42. What happens when an ion reaches the mass spectrometer detector?

    It strikes a plate and produces an electrical signal.

  43. What does a mass spectrum represent?

    The ions produced from a compound, displayed according to their mass-to-charge ratios and intensities.

  44. How are the chromatogram and mass spectrum related in GC–MS?

    The chromatogram shows when compounds elute, while the mass spectrum shows the ions produced by a compound eluting at a selected time.

  45. Why can mass spectra sometimes be similar for different compounds?

    Different compounds can produce overlapping or similar fragmentation patterns.

  46. How can hydrocarbon fragmentation patterns reflect carbon number?

    For octane, several groups may appear separated by 14 daltons, reflecting fragmentation patterns associated with carbon-number differences.

  47. What can a significant mass-spectral gap suggest about a hydrocarbon structure?

    It may indicate that a side chain has broken off.

  48. What structural information can a six-membered-ring fragment provide?

    It can suggest the presence of a benzene ring.

  49. What can a mass loss of 18 suggest during mass-spectrum interpretation?

    The loss of a hydroxyl-related group containing hydrogen and oxygen.

  50. What must be true about a sample before it can be injected into a GC?

    Its compounds must be soluble in a suitable solvent and sufficiently volatile for GC analysis.

  51. What types of solvents are generally suitable for GC sample preparation?

    Volatile organic solvents.

  52. How do hexane and dichloromethane differ in polarity?

    Hexane is nonpolar, whereas dichloromethane is polar.

  53. Why should water generally not be used as a GC solvent?

    Water can remain liquid in the column until the temperature exceeds its boiling point, potentially filling the column with liquid and disrupting the analysis.

  54. Why are hexane and dichloromethane useful GC solvents?

    They boil at relatively low temperatures and therefore vaporize and leave the column quickly.

  55. What sensitivity range is given for the electron-impact GC–MS system?

    Approximately 1 to 100 picograms per component.

  56. What is the typical GC–MS injection volume described?

    One microliter.

  57. What are the possible levels of complexity in GC–MS sample preparation?

    Preparation may range from simply dissolving a sample in a suitable solvent to using extensive cleanup and extraction procedures.

  58. What is liquid–liquid extraction?

    A cleanup or concentration method that transfers compounds between two immiscible liquid phases.

  59. What is solid-phase extraction?

    A method in which a sample passes through a modified solid material that retains matrix components or target compounds.

  60. What is the purpose of cleanup in sample preparation?

    To remove matrix or dirty material while transferring as much compound of interest as possible into the GC–MS.

  61. How is a compound identified using GC retention time?

    Its retention time is compared with the retention time of a known standard analyzed under the same chromatographic conditions.

  62. Why must the GC method remain unchanged when comparing retention times?

    Because changes in chromatographic conditions can change the times at which compounds elute.

  63. Why is retention time alone not always sufficient to identify a compound?

    Different compounds can have similar retention times, so mass-spectral information is also needed for stronger identification.

  64. How can a mass spectrum be used for qualitative identification?

    The sample's fragmentation pattern is compared with a reference spectrum from a database or a known standard.

  65. What database was mentioned as a source of reference mass spectra?

    The NIST WebBook.

  66. What evidence supported the identification of salicylic acid in the example?

    The sample had a peak at the expected retention time and mass-spectral ions near 138, 120, and 92 with similar intensities to the reference spectrum.

  67. What is required if no reference database is available for a compound?

    The mass spectrum must be interpreted manually or compared with a known standard.

  68. Why can a known standard help identify an unknown compound?

    The standard provides a reference retention time and mass spectrum for comparison with the unknown.

  69. What was the purpose of analyzing CBD samples by GC–MS?

    To determine which chemical components were present in CBD products.

  70. How was the CBD sample prepared for GC–MS analysis?

    It was diluted and injected directly into the system.

  71. Why did the CBD product sample have more chromatographic peaks than the CBD standard?

    CBD is a natural product, so the product can contain additional components besides the CBD standard.

  72. What did the later-eluting peak in the CBD product appear to be?

    Tetrahydrocannabinol, or THC.

  73. What unexpected result was observed near the CBD standard peak?

    A second CBD-related peak appeared at about 13.96 minutes, while the known CBD standard eluted at about 14.54 minutes.

  74. Why was the second CBD-related peak not identified with complete certainty?

    A second standard containing the alternative stereochemical form would be needed for confirmation.

  75. Why might GC distinguish certain stereoisomers that MS alone cannot distinguish?

    The GC can separate them through differences in boiling point or interactions with the column, even when their mass spectra are the same or very similar.

  76. What CBD-related medical use was associated with the FDA-approved product mentioned?

    Treatment of seizures.

  77. What is the purpose of stormwater retention ponds?

    They temporarily store stormwater and allow it to soak into the ground more naturally, reducing the risk of flash flooding.

  78. Why might stormwater retention ponds act as point sources of pollution?

    Runoff from impervious surfaces such as parking lots can carry petroleum leaked from vehicles into the ponds.

  79. What was the current result of testing retention pond water for petroleum compounds?

    Spiked samples could be recovered, but the compounds had not yet been detected in the actual pond water samples.

  80. What additional environmental sample was proposed for petroleum analysis?

    Soil cores collected around the retention ponds.

  81. How could a purge-and-trap system improve retention pond analysis?

    It would perform the extraction and inject the sample into the GC–MS, substantially reducing opportunities for laboratory contamination.

  82. What extraction method was used for retention pond water?

    Liquid–liquid extraction.

  83. What approximate volumes were used in the retention pond extraction?

    About 500 milliliters of pond water and 30 to 100 milliliters of dichloromethane or hexane.

  84. Which layer is on the bottom when dichloromethane is used in a separatory funnel?

    The dichloromethane layer, because it is denser than water.

  85. Why are multiple liquid–liquid extractions sometimes performed?

    To improve cleanup and recover more of the compound of interest.

  86. Why is pond water concentrated before GC–MS analysis?

    Target compounds are present at very low levels, so concentrating the sample increases their detectability.

  87. What is a deuterated standard?

    A standard compound in which hydrogen atoms are replaced by deuterium, a heavier isotope of hydrogen.

  88. Why was deuterated octane used in the retention pond project?

    It served as a labeled standard for tracking gasoline-related compounds through the extraction and analysis.

  89. Why can deuterated octane be distinguished from ordinary octane by GC–MS?

    The compounds have the same or similar retention times, but deuterium increases the mass-to-charge ratios of the labeled ions, allowing MS to distinguish them.

  90. How does deuterium affect the mass of a compound?

    Each deuterium contributes approximately one additional atomic mass unit compared with hydrogen.

  91. How can a deuterated standard support recovery measurements?

    Because a known amount is added before extraction, the recovered peak area can be used to estimate how much compound was recovered.

  92. Can GC–MS be used to measure ethanol produced by fermentation?

    Yes. A GC method for alcohols can be selected, and the fermented sample can then be injected and analyzed.

  93. What other instruments could potentially be used to analyze fermentation alcohols?

    Infrared spectroscopy and liquid chromatography, in addition to GC–MS.

  94. What types of projects besides CBD and pond-water analysis could use GC–MS?

    Projects involving plant constituents, tomatoes, aspirin, and reaction kinetics were mentioned as possibilities.