Which factors affect a convection coefficient?
Fluid velocity, fluid properties, flow conditions, operating temperature, and surface geometry.
Or swipe the card
49 cards
Which factors affect a convection coefficient?
Fluid velocity, fluid properties, flow conditions, operating temperature, and surface geometry.
What does the Prandtl number compare, and what does it indicate about boundary layers?
It is the ratio of momentum diffusivity to thermal diffusivity, so it indicates the relative thicknesses of the hydrodynamic and thermal boundary layers.
What dimensionless number relates convection heat transfer to the dimensionless temperature gradient at a surface?
The Nusselt number.
How does the local convection coefficient vary along a flat plate in laminar parallel flow?
It is largest at the leading edge and decreases downstream through the laminar region.
What Reynolds number is commonly used as a guideline for transition on a flat plate in parallel flow?
Approximately Re=500,000. This is a guideline, not a strict transition threshold.
What distinguishes internal convection from external flow over a plate as the flow develops?
In a pipe or duct, boundary layers grow inward from the walls and eventually meet, changing the flow from developing to fully developed.
What happens to the core flow in the entrance region of a pipe?
The core initially retains the inlet velocity, but shrinks as the wall boundary layers grow until the layers meet.
What does it mean for pipe flow to be hydrodynamically fully developed?
The velocity profile no longer changes with position along the pipe.
What is the velocity profile for fully developed laminar flow in a circular pipe?
A parabolic velocity profile.
What does the hydrodynamic entrance length xfd,h represent?
The distance from the pipe inlet required for the velocity profile to become fully developed.
What does the thermal entrance length xfd,t represent?
The distance from the pipe inlet required for the temperature profile to become thermally fully developed.
What does thermally fully developed flow mean?
The temperature profile’s shape no longer changes with axial position, though the fluid’s overall temperature can still change.
How can boundary conditions affect the temperature profile in a duct?
Constant wall temperature and constant wall heat flux produce different temperature profiles; constant heat flux imposes a particular wall temperature slope.
How do the friction factor and heat transfer coefficient behave from the entrance region into fully developed flow?
They change with axial position in the developing region and remain constant with position once the flow is fully developed.
What characteristic length is used in the Reynolds number for internal flow through a circular pipe?
The pipe diameter.
How is hydraulic diameter defined for a noncircular duct?
Dh=Pw4A, where A is the cross-sectional area and Pw is the wetted perimeter.
What Reynolds number is commonly used as a guideline for transition in pipe flow?
Approximately Re=2,300; it is a practical guideline rather than an exact boundary.
What is the laminar hydrodynamic entrance-length relation for internal flow?
xfd,h=0.05ReD, where D is the characteristic diameter.
How can the laminar thermal entrance length be calculated from the hydrodynamic entrance length?
xfd,t=0.05RePrD=Prxfd,h.
What entrance length is commonly assumed for turbulent flow in a pipe?
Both hydrodynamic and thermal flow are assumed fully developed after about 10D.
How does the Prandtl number affect the relative hydrodynamic and thermal entrance lengths?
For Pr≫1 (such as oil), the hydrodynamic boundary layer is thinner than the thermal one. For Pr≈1 (such as air), the entrance lengths are similar. For Pr≪1 (such as mercury), the hydrodynamic entrance length is larger.
What is the definition of the Nusselt number for flow in a circular tube?
Nu=khD, where h is the convection coefficient, D is the tube diameter, and k is the fluid thermal conductivity.
What Nusselt number applies to fully developed laminar flow in a circular tube with constant wall heat flux?
Nu=4.36.
What Nusselt number applies to fully developed laminar flow in a circular tube with constant wall temperature?
Nu=3.66.
How can the convection coefficient be found from a Nusselt number for flow in a circular tube?
Rearrange Nu=khD to get h=DNuk.
What is the general form of the smooth-tube turbulent Nusselt correlation described in the lecture?
It is proportional to Re0.8Prn, with the Prandtl-number exponent depending on whether the fluid is heated or cooled.
In the described turbulent tube correlation, what value of n is used when the fluid is being cooled?
Use n=0.3 when the fluid is warmer than the surface.
In the described turbulent tube correlation, what value of n is used when the fluid is being heated?
Use n=0.4 when the surface is warmer than the fluid.
How can the Nusselt number be found for developing internal flow?
Use an appropriate developing-flow table or a correlation expressed in terms of the Graetz number.
What characteristic length should be used in Reynolds and Nusselt numbers for a noncircular duct?
Use the hydraulic diameter, Dh=Pw4A, in place of the circular-pipe diameter.
At what temperature are internal-flow fluid properties commonly evaluated when inlet and outlet temperatures are known?
At the mean fluid temperature, Tm=2Tin+Tout.
What can be done if the outlet temperature needed to evaluate internal-flow properties is unknown?
Guess an outlet temperature, evaluate properties at the resulting mean temperature, calculate the outlet temperature, and update the guess if needed.
For constant wall heat flux, how much heat enters the fluid over a pipe length x?
Q=q′′Pwx, where q′′ is the wall heat flux and Pw is the wetted perimeter.
What energy balance relates heat added to a fluid to its temperature rise over a pipe length?
Q=m˙cp(Tx−Tin), where Tx is the fluid temperature at position x.
For constant heat flux, how can the fluid temperature at position x be related to the heat input?
Set q′′Pwx=m˙cp(Tx−Tin).
For fully developed flow with constant wall heat flux, how is wall-to-fluid temperature difference related to heat transfer?
The wall-to-fluid temperature difference is constant along the fully developed region, and the heat transfer rate follows Newton’s law of cooling, Q=hAΔT.
For constant wall temperature, how does the fluid-to-surface temperature difference vary with position?
ΔTinΔTx=exp(−m˙cphPwx), where ΔTx=Ts−Tx and ΔTin=Ts−Tin.
How is the log-mean temperature difference defined for constant wall-temperature convection?
ΔTlm=ln(ΔTx/ΔTin)ΔTx−ΔTin, using the surface-to-fluid temperature differences at position x and at the inlet.
How can total heat transfer be calculated for constant wall-temperature flow through a pipe?
Use both Q=m˙cp(Tx−Tin) and Q=hAΔTlm.
How do you calculate total heat transfer over the full pipe length using a relation written for position x?
Set x=L, where L is the pipe length.
When should absolute temperatures be used rather than temperature differences?
Use absolute temperatures in expressions that require a temperature itself, such as evaluating properties; temperature differences can be expressed in Celsius or kelvins. Kelvin is a safe choice when unsure.
What is a useful order for solving an internal-convection problem?
Identify the geometry and boundary conditions; find the Reynolds number and flow regime; determine whether the flow is developing or fully developed; select a suitable Nusselt correlation; then find h and solve the energy balance.
How can average velocity be found from mass flow rate in a pipe?
Use V=ρAcm˙, where Ac is the cross-sectional area.
Why should mass flow rates given per hour often be converted before calculations?
Converting to kilograms per second helps keep units consistent and avoids using an hourly value as though it were per second.
In the compressed-air example, what flow regime was indicated by a Reynolds number of about 60,000?
Turbulent flow, since it is well above the approximate pipe-transition guideline of 2,300.
In the compressed-air example, what was the turbulent entrance length for a 10mm-diameter pipe?
About 10D=0.10m for both the hydrodynamic and thermal profiles.
In the compressed-air example, which turbulent correlation exponent was appropriate for the Prandtl number?
The fluid was being cooled because its inlet temperature exceeded the wall temperature, so n=0.3.
In the compressed-air example, what Nusselt number and convection coefficient were calculated?
The calculation gave Nu=137.3 and h=466.8W/(m2K).
In the compressed-air example, what outlet temperature was calculated for air entering at 125∘C a 45∘C pipe?
Approximately 51∘C at the outlet of the 2m pipe.