Which set of factors affects the convection heat transfer coefficient?
Which set of factors affects the convection heat transfer coefficient?
48 questions
- 1
Which set of factors affects the convection heat transfer coefficient?
- A
Fluid velocity, fluid properties, flow conditions, operating temperature, and surface geometry
- B
Fluid properties and operating temperature, but not flow conditions or surface geometry
- C
Surface geometry and flow conditions, but not fluid velocity or operating temperature
- D
Fluid velocity and surface geometry, but not fluid properties or operating temperature
Correct answer
AFluid velocity, fluid properties, flow conditions, operating temperature, and surface geometry
Explanation
The convection coefficient depends on fluid velocity and properties, flow conditions, operating temperature, and surface geometry.
- A
- 2
Which dimensionless number compares momentum diffusivity with thermal diffusivity?
- A
The Nusselt number
- B
The Prandtl number
- C
The Reynolds number
- D
The Graetz number
Correct answer
BThe Prandtl number
Explanation
The Prandtl number compares momentum diffusivity with thermal diffusivity, relating the growth of the velocity and thermal boundary layers.
- A
- 3
For laminar parallel flow over a flat plate, how does the local convection coefficient typically vary along the plate?
- A
It stays constant from the leading edge to the trailing edge
- B
It decreases at first and then increases while the flow remains laminar
- C
It is smallest near the leading edge and increases downstream
- D
It is largest near the leading edge and decreases downstream
Correct answer
DIt is largest near the leading edge and decreases downstream
Explanation
In the laminar region over a flat plate, the local convection coefficient is largest at the front of the plate and decreases along it.
- A
- 4
What can happen to the local heat transfer coefficient when flow over a flat plate transitions from laminar to turbulent?
- A
It can undergo an increase as the flow becomes turbulent
- B
It remains unchanged because the surface geometry is fixed
- C
It becomes zero at the point of transition
- D
It must decrease continuously through the transition
Correct answer
AIt can undergo an increase as the flow becomes turbulent
Explanation
The transition to turbulence can produce an increase in the heat transfer coefficient; the laminar decrease does not describe the turbulent region.
- A
- 5
What Reynolds number is commonly used as a guideline for transition from laminar to turbulent flow over a flat plate?
- A
Approximately 10
- B
Approximately 2,300
- C
Approximately 60,000
- D
Approximately 500,000
Correct answer
DApproximately 500,000
Explanation
A Reynolds number of about 500,000 is a heuristic for transition over a flat plate, not a strict threshold that applies in every flow condition.
- A
- 6
What happens when the hydrodynamic boundary layers developing inward from a duct or pipe wall meet?
- A
The fluid core begins to grow, so the flow becomes less developed downstream
- B
The flow returns to its inlet profile and begins a new entrance region
- C
The flow reaches the fully developed region, and the velocity profile no longer changes along the duct
- D
The flow must become turbulent, regardless of its Reynolds number
Correct answer
CThe flow reaches the fully developed region, and the velocity profile no longer changes along the duct
Explanation
The velocity boundary layers grow from the walls and eventually overlap. Beyond that entrance length, the flow is hydrodynamically fully developed.
- A
- 7
What is the fluid core like in the hydrodynamic entrance region of a pipe?
- A
It retains approximately the inlet velocity while shrinking as the wall boundary layers grow
- B
It has zero velocity until the boundary layers meet
- C
It immediately has the parabolic profile of fully developed laminar pipe flow
- D
It accelerates continuously as the wall boundary layers grow
Correct answer
AIt retains approximately the inlet velocity while shrinking as the wall boundary layers grow
Explanation
In the entrance region, the central core remains approximately at the inlet velocity while the boundary layers grow inward and shrink the core.
- A
- 8
What velocity profile is associated with fully developed laminar flow in a circular pipe?
- A
A triangular profile
- B
A uniform profile
- C
A parabolic profile
- D
A profile with zero velocity at the center and maximum velocity at the wall
Correct answer
CA parabolic profile
Explanation
Fully developed laminar flow in a circular pipe has the familiar parabolic velocity distribution.
- A
- 9
What does xfd,h denote?
- A
The distance over which the pipe wall has a constant temperature
- B
The pipe length over which the flow must remain turbulent
- C
The distance from the pipe entrance to thermally fully developed flow
- D
The distance from the pipe entrance to hydrodynamically fully developed flow
Correct answer
DThe distance from the pipe entrance to hydrodynamically fully developed flow
Explanation
The subscript h identifies the hydrodynamic entrance length: the distance needed for the velocity profile to become fully developed.
- A
- 10
What does xfd,t denote?
- A
The distance at which the fluid reaches the wall temperature
- B
The distance from the pipe entrance to hydrodynamically fully developed flow
- C
The distance at which the flow transitions from laminar to turbulent
- D
The distance from the pipe entrance to thermally fully developed flow
Correct answer
DThe distance from the pipe entrance to thermally fully developed flow
Explanation
The subscript t identifies the thermal entrance length: the distance needed for the temperature profile to become fully developed.
- A
- 11
What does it mean for the temperature profile to be thermally fully developed?
- A
The fluid temperature equals the wall temperature everywhere
- B
Its shape no longer changes with distance along the pipe
- C
The heat transfer coefficient becomes zero
- D
The fluid temperature no longer differs between the center and wall
Correct answer
BIts shape no longer changes with distance along the pipe
Explanation
In the thermally fully developed region, the temperature profile's shape no longer changes along the pipe, although temperatures may still change with position.
- A
- 12
How do the wall boundary conditions affect internal thermal-flow profiles?
- A
Constant wall temperature and constant wall heat flux produce different temperature profiles
- B
They affect the entrance region but not the fully developed temperature profile
- C
They affect the velocity profile but not the temperature profile
- D
They produce identical profiles whenever the flow is fully developed
Correct answer
AConstant wall temperature and constant wall heat flux produce different temperature profiles
Explanation
The temperature profile depends on the wall boundary condition. Constant surface temperature and constant heat flux lead to different profiles.
- A
- 13
How do the friction factor and heat transfer coefficient typically behave along a duct?
- A
They increase continuously throughout both regions
- B
They change in the developing region and become constant in the fully developed region
- C
They decrease to zero once the flow becomes fully developed
- D
They remain constant in the developing region and change only after the flow is fully developed
Correct answer
BThey change in the developing region and become constant in the fully developed region
Explanation
The friction factor and heat transfer coefficient vary with position during development and remain constant once the corresponding flow is fully developed.
- A
- 14
What does the Prandtl number indicate about the relative development of hydrodynamic and thermal boundary layers?
- A
It compares surface temperature with inlet temperature and therefore determines heat flux
- B
It compares fluid density with viscosity and therefore determines the pipe's wetted perimeter
- C
It compares momentum diffusivity with thermal diffusivity and therefore relates to their relative thicknesses
- D
It compares pipe length with diameter and therefore determines whether the flow is turbulent
Correct answer
CIt compares momentum diffusivity with thermal diffusivity and therefore relates to their relative thicknesses
Explanation
Because the Prandtl number is the ratio of momentum diffusivity to thermal diffusivity, it helps compare the relative thicknesses of the hydrodynamic and thermal boundary layers.
- A
- 15
For a fluid with a Prandtl number much greater than one, such as oil in the described comparison, which entrance length is relatively shorter?
- A
The two entrance lengths must be equal
- B
Neither entrance length can be compared using the Prandtl number
- C
The thermal entrance length
- D
The hydrodynamic entrance length
Correct answer
DThe hydrodynamic entrance length
Explanation
For a Prandtl number much greater than one, the hydrodynamic boundary layer is smaller than the thermal boundary layer, so the hydrodynamic entrance length is shorter.
- A
- 16
What relationship between entrance lengths is expected when the Prandtl number is much less than one, as for mercury in the described comparison?
- A
The hydrodynamic entrance length is much larger than the thermal entrance length
- B
Both entrance lengths are zero
- C
The thermal entrance length is much larger than the hydrodynamic entrance length
- D
The two entrance lengths are necessarily equal
Correct answer
AThe hydrodynamic entrance length is much larger than the thermal entrance length
Explanation
For a Prandtl number much less than one, the hydrodynamic entrance length is much larger than the thermal entrance length.
- A
- 17
If the Prandtl number is close to one, what is expected of the hydrodynamic and thermal entrance lengths?
- A
One entrance length is zero while the other is nonzero
- B
The hydrodynamic entrance length is always ten times longer
- C
They are relatively similar in size
- D
The thermal entrance length is always ten times longer
Correct answer
CThey are relatively similar in size
Explanation
When the Prandtl number is close to one, the two boundary-layer development lengths are relatively similar.
- A
- 18
When inlet and outlet fluid temperatures are known, what temperature is used to evaluate internal-flow properties in the described procedure?
- A
The inlet temperature minus the outlet temperature
- B
The average, 2Tin+Tout
- C
The higher of the inlet and outlet temperatures
- D
The wall temperature alone
Correct answer
BThe average, 2Tin+Tout
Explanation
For internal flow, properties are evaluated at the average fluid temperature along the channel, calculated as 2Tin+Tout.
- A
- 19
If the outlet temperature is unknown and property accuracy matters, how can the internal-flow property temperature be determined?
- A
Use the inlet temperature as the average without checking the outlet
- B
Guess an outlet temperature, calculate the average temperature, and update the guess using the calculated outlet
- C
Use the wall temperature as the average fluid temperature
- D
Assume the outlet temperature equals the inlet temperature in every case
Correct answer
BGuess an outlet temperature, calculate the average temperature, and update the guess using the calculated outlet
Explanation
An iterative procedure can be used: guess the outlet temperature, calculate properties at the resulting average temperature, solve for the outlet, and revise the guess if needed.
- A
- 20
Which characteristic dimension is used for Reynolds and Nusselt numbers in a circular pipe?
- A
The pipe's wetted perimeter
- B
The pipe length
- C
The pipe's cross-sectional area
- D
The pipe diameter
Correct answer
DThe pipe diameter
Explanation
For a circular pipe, the characteristic dimension used in these dimensionless numbers is the pipe diameter.
- A
- 21
What characteristic dimension is used for a noncircular duct in the described internal-flow method?
- A
The largest side length of the duct, regardless of its cross-section
- B
The duct length divided by its area
- C
The hydraulic diameter, Dh=Pw4A
- D
The wetted perimeter divided by four times the area
Correct answer
CThe hydraulic diameter, Dh=Pw4A
Explanation
For a noncircular duct, the hydraulic diameter is Dh=Pw4A, where A is cross-sectional area and Pw is wetted perimeter.
- A
- 22
What Reynolds number is used as an approximate laminar-to-turbulent transition guideline for flow in a tube or channel?
- A
Approximately 2,300
- B
Approximately 10
- C
Approximately 60,000
- D
Approximately 500,000
Correct answer
AApproximately 2,300
Explanation
For flow through a tube or channel, transition is commonly estimated around a Reynolds number of 2,300, unlike the flat-plate guideline of about 500,000.
- A
- 23
Which expression defines the Nusselt number for internal flow in a circular tube?
- A
Nu=kμcp
- B
Nu=khD
- C
Nu=hDk
- D
Nu=μρVD
Correct answer
BNu=khD
Explanation
For a circular tube, the Nusselt number is defined as Nu=khD, with the diameter serving as the characteristic dimension.
- A
- 24
For fully developed laminar flow in a circular tube with uniform wall heat flux, what Nusselt number is given?
- A
Nu=0.3
- B
Nu=4.36
- C
Nu=3.66
- D
Nu=0.8
Correct answer
BNu=4.36
Explanation
The stated fully developed laminar correlation for uniform wall heat flux is the constant Nu=4.36.
- A
- 25
For fully developed laminar flow in a circular tube with constant wall temperature, what Nusselt number is given?
- A
Nu=0.4
- B
Nu=3.66
- C
Nu=0.05
- D
Nu=4.36
Correct answer
BNu=3.66
Explanation
The stated fully developed laminar correlation for constant wall temperature is the constant Nu=3.66.
- A
- 26
After obtaining a Nusselt number for a circular tube, how can the convection coefficient be found?
- A
Rearrange Nu=khD to obtain h=DNuk
- B
Multiply the Nusselt number by the pipe length and divide by the mass flow rate
- C
Rearrange Nu=khD to obtain h=NuDk
- D
Divide the Nusselt number by the Reynolds number and multiply by the pipe diameter
Correct answer
ARearrange Nu=khD to obtain h=DNuk
Explanation
Rearranging the definition Nu=khD gives h=DNuk.
- A
- 27
In the smooth-tube turbulent correlation described, what powers of Reynolds number and Prandtl number are used?
- A
Re0.8 and Prn
- B
Ren and Pr0.3
- C
Re0.3 and Pr0.8
- D
Re0.05 and Pr1
Correct answer
ARe0.8 and Prn
Explanation
The smooth-tube turbulent correlation described uses a constant multiplied by Re0.8 and Prn.
- A
- 28
For the described turbulent-tube correlation, what value of n is used when the fluid is warmer than the surface and is being cooled?
- A
n=0.8
- B
n=4.36
- C
n=0.3
- D
n=0.4
Correct answer
Cn=0.3
Explanation
When the fluid is warmer than the surface, the described correlation uses n=0.3.
- A
- 29
For the described turbulent-tube correlation, what value of n is used when the surface is warmer than the fluid and heats it?
- A
n=3.66
- B
n=0.3
- C
n=0.4
- D
n=0.8
Correct answer
Cn=0.4
Explanation
When the surface is warmer than the fluid, the described correlation uses n=0.4.
- A
- 30
What approach is suggested when a turbulent-flow pipe is not smooth or the flow is transitional?
- A
Use the alternative correlation provided for those conditions rather than the smooth-pipe correlation
- B
Set the Nusselt number equal to the hydraulic diameter
- C
Use the flat-plate transition Reynolds number as the Nusselt number
- D
Use the fully developed laminar constant-temperature value Nu=3.66
Correct answer
AUse the alternative correlation provided for those conditions rather than the smooth-pipe correlation
Explanation
The material distinguishes a smooth-pipe turbulent correlation from an alternative correlation for transitional flow or a pipe that is not smooth.
- A
- 31
How can the Nusselt number be obtained when internal flow is still developing?
- A
Read an appropriate value from a table or use a correlation involving the Graetz number
- B
Assume the Nusselt number is zero until the entrance length ends
- C
Use only the fully developed laminar constants, regardless of flow conditions
- D
Set the Nusselt number equal to the Reynolds number
Correct answer
ARead an appropriate value from a table or use a correlation involving the Graetz number
Explanation
For developing flow, the Nusselt number can be obtained from a table or from a relation involving the Graetz number.
- A
- 32
For laminar flow in a noncircular duct, how is the Nusselt-number constant selected in the described method?
- A
Use the wetted perimeter alone, regardless of cross-sectional shape
- B
Use the circular-tube constant for every cross-section
- C
Use the Reynolds number alone, regardless of geometry or boundary condition
- D
Use the duct geometry or aspect ratio and the wall boundary condition
Correct answer
DUse the duct geometry or aspect ratio and the wall boundary condition
Explanation
For laminar noncircular ducts, the appropriate constant depends on geometry, such as aspect ratio, and on whether wall temperature or heat flux is specified.
- A
- 33
For turbulent flow in a noncircular duct, what change is made to the described circular-tube correlation procedure?
- A
Use the wetted perimeter in place of the Nusselt number
- B
Use a laminar constant instead of a turbulent correlation
- C
Use the duct length as the characteristic dimension
- D
Use the hydraulic diameter in place of the circular-pipe diameter
Correct answer
DUse the hydraulic diameter in place of the circular-pipe diameter
Explanation
The turbulent correlation is used in the same way, but the hydraulic diameter replaces the diameter of a circular pipe.
- A
- 34
For a pipe with constant wall heat flux, what is the heat added to the fluid over a pipe segment of length x?
- A
q=q′′Pwx
- B
q=Pwxq′′
- C
q=q′′Dx
- D
q=hPwx
Correct answer
Aq=q′′Pwx
Explanation
With constant heat flux, heat transfer over length x equals the heat flux multiplied by the wall area in that segment: q=q′′Pwx.
- A
- 35
In a nonboiling fluid under constant wall heat flux, what does an energy balance equate to the heat added up to position x?
- A
The fluid's enthalpy increase, m˙cp(Tx−Tin)
- B
The wall temperature multiplied by the wetted perimeter
- C
The friction factor multiplied by the Reynolds number
- D
The fluid's density multiplied by the pipe length
Correct answer
AThe fluid's enthalpy increase, m˙cp(Tx−Tin)
Explanation
The heat entering the nonboiling fluid raises its temperature, so q=m˙cp(Tx−Tin) for the segment up to x.
- A
- 36
Under constant wall heat flux, what follows from equating the heat input to the fluid's enthalpy increase?
- A
The fluid temperature remains equal to its inlet temperature
- B
The heat transfer coefficient must be zero in the developing region
- C
The fluid temperature at position x can be found from q′′Pwx=m˙cp(Tx−Tin)
- D
The outlet temperature must equal the wall temperature
Correct answer
CThe fluid temperature at position x can be found from q′′Pwx=m˙cp(Tx−Tin)
Explanation
Combining q=q′′Pwx with q=m˙cp(Tx−Tin) gives the stated relation for the fluid temperature.
- A
- 37
When the flow is thermally fully developed under constant wall heat flux, what happens to the temperature difference between the wall and fluid?
- A
It remains constant along the pipe
- B
It becomes zero at the entrance
- C
It increases linearly without limit along the pipe
- D
It changes only when the flow becomes turbulent
Correct answer
AIt remains constant along the pipe
Explanation
In the fully developed region, the temperature profile's shape no longer changes; for the constant-heat-flux case described, the wall-to-fluid temperature difference remains constant.
- A
- 38
For constant wall temperature, how does the described dimensionless temperature difference vary with position?
- A
It increases linearly with x and is independent of h
- B
It varies only with the pipe diameter and not with flow rate
- C
It follows an exponential decay involving hPwx/(m˙cp)
- D
It remains equal to one for the entire pipe
Correct answer
CIt follows an exponential decay involving hPwx/(m˙cp)
Explanation
The ratio of the wall-to-fluid temperature difference at position x to its inlet value follows an exponential involving −hPwx/(m˙cp).
- A
- 39
For constant wall temperature, which temperature difference is used in the convection relation for total heat transfer?
- A
The log-mean temperature difference between the wall and fluid
- B
The arithmetic mean of inlet and outlet wall temperatures
- C
The temperature difference between the inlet and outlet walls
- D
The inlet fluid temperature minus the outlet fluid temperature alone
Correct answer
AThe log-mean temperature difference between the wall and fluid
Explanation
For a constant surface temperature, the described convection relation uses a log-mean temperature difference between the surface and the fluid.
- A
- 40
How is the log-mean temperature difference for a constant-temperature wall formed?
- A
By dividing the larger end temperature difference by the pipe length
- B
By subtracting the inlet fluid temperature from the outlet fluid temperature and taking the square root
- C
By dividing the difference between the two end temperature differences by the natural logarithm of their ratio
- D
By adding the two end temperature differences and dividing by their product
Correct answer
CBy dividing the difference between the two end temperature differences by the natural logarithm of their ratio
Explanation
The log-mean temperature difference uses the difference between the end temperature differences divided by the natural logarithm of their ratio.
- A
- 41
In the constant-wall-temperature case, what energy balance can be used to calculate heat transferred to the fluid?
- A
q=m˙cpTs without using the fluid temperature change
- B
q=m˙cpΔT for the fluid, together with the convection relation using the log-mean temperature difference
- C
q=q′′A even though the wall temperature, rather than heat flux, is specified
- D
q=hA without any temperature difference
Correct answer
Bq=m˙cpΔT for the fluid, together with the convection relation using the log-mean temperature difference
Explanation
The heat gained by the fluid is q=m˙cpΔT. It can be related to convection at the wall using hA times the log-mean temperature difference.
- A
- 42
How can total heat transfer over a constant-wall-temperature pipe of length L be found from the position-dependent relation?
- A
Set the position equal to the entrance length regardless of the pipe length
- B
Evaluate the relation at x=0
- C
Replace the pipe length with the diameter
- D
Evaluate the relation at x=L
Correct answer
DEvaluate the relation at x=L
Explanation
The relation for a position x gives the total pipe result when evaluated at the full length, x=L.
- A
- 43
In the compressed-air example, why was the mass flow rate converted from kilograms per hour to kilograms per second before calculations?
- A
To use consistent units and avoid using the hourly value as though it were per second
- B
To convert the mass flow rate into a Reynolds number directly
- C
To make the fluid's specific heat independent of temperature
- D
To ensure the flow is classified as laminar
Correct answer
ATo use consistent units and avoid using the hourly value as though it were per second
Explanation
Converting the mass flow rate to kilograms per second helps maintain consistent units and prevents mistakenly using the numerical hourly rate as a per-second rate.
- A
- 44
How was average velocity obtained in the compressed-air pipe example when mass flow rate was given instead of velocity?
- A
Multiply mass flow rate by the wetted perimeter
- B
Multiply mass flow rate by density and pipe length
- C
Divide density by mass flow rate and diameter
- D
Divide mass flow rate by density and cross-sectional area
Correct answer
DDivide mass flow rate by density and cross-sectional area
Explanation
Using m˙=ρVA, the average velocity is V=ρAm˙.
- A
- 45
The compressed-air example had a Reynolds number of about 60,000 in a tube. How was the flow classified using the stated tube-transition guideline?
- A
Laminar, because 60,000 is less than about 500,000
- B
Laminar, because the tube had a constant wall temperature
- C
Turbulent, because 60,000 is much greater than about 2,300
- D
Transitional, because the tube diameter was 10 millimeters
Correct answer
CTurbulent, because 60,000 is much greater than about 2,300
Explanation
For internal tube flow, the approximate transition guideline is a Reynolds number of 2,300. A value near 60,000 is well above it, so the example treats the flow as turbulent.
- A
- 46
For the turbulent example pipe with diameter 0.01m, what entrance length was estimated using the rule of ten diameters?
- A
0.01m for hydrodynamic development and 0.1m for thermal development
- B
0.1m for both hydrodynamic and thermal development
- C
10m for both hydrodynamic and thermal development
- D
1m for hydrodynamic development and 0.01m for thermal development
Correct answer
B0.1m for both hydrodynamic and thermal development
Explanation
For turbulent flow, the example assumes both entrance lengths are about ten diameters. Ten times 0.01m is 0.1m.
- A
- 47
In the compressed-air example, why was n=0.3 selected for the turbulent-tube correlation?
- A
The flow was laminar and the wall heat flux was constant
- B
The pipe surface was hotter than the fluid, so the fluid was being heated
- C
The pipe was noncircular and had a high aspect ratio
- D
The fluid was hotter than the pipe surface, so it was being cooled
Correct answer
DThe fluid was hotter than the pipe surface, so it was being cooled
Explanation
The air entered at 125∘C while the wall was at 45∘C, so the fluid was hotter than the surface and being cooled; the described correlation uses n=0.3 in that case.
- A
- 48
What outlet temperature was obtained in the compressed-air example for the pipe with a 45∘C wall and 125∘C inlet air?
- A
Approximately 230∘C
- B
Approximately 125∘C
- C
Approximately 45∘C
- D
Approximately 51∘C
Correct answer
DApproximately 51∘C
Explanation
Using the constant-wall-temperature relation and the example's calculated convection coefficient, the air outlet temperature was approximately 51∘C.