1. Home
  2. Explore
  3. Engineering
  4. External Convection and Heat Transfer

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

External Convection and Heat Transfer

Speaker 1Speaker 2

External Convection and Heat Transfer

15:18
0:00-15:18
  1. Anna

    Before we get into today’s lecture, a quick course update: the instructor is posting YouTube links alongside the videos on MyCourses, and teaching assistants are working on captions for the recordings. The goal is to make those captioned versions available about a day after the video is posted.

  2. Maria

    And the opening quiz reviews external convection. First up: what affects the convection coefficient? Fluid velocity, fluid properties, flow conditions, operating temperature, and surface geometry all matter, so the answer is all of the above.

  3. Anna

    The next question asks which dimensionless number compares momentum diffusivity with thermal diffusivity. Momentum diffusivity relates to how the velocity boundary layer develops, while thermal diffusivity relates to how the thermal boundary layer develops. The ratio is described by the Prandtl number.

  4. Maria

    There’s also a statement about a flat plate in laminar parallel flow: the local convection coefficient is largest at the front and decreases along the plate. That statement is true for the laminar region, because the boundary layer grows as you move along the plate. If the flow transitions to turbulence, the coefficient can jump upward, but that isn’t part of the stated laminar-flow case.

  5. Anna

    For a flat plate in parallel flow, the usual guideline for the transition Reynolds number is about 500,000. It’s a heuristic, not a sharp dividing line: flow conditions can make transition occur earlier or later.

  6. Maria

    And the dimensionless parameter associated with the dimensionless temperature gradient at the surface is the Nusselt number. The heat transfer coefficient is proportional to that surface temperature gradient, and the Nusselt number expresses the dimensionless heat-transfer behavior.

  7. Anna

    With that review done, let’s shift from external convection to internal convection—flow inside a pipe or duct. The big difference is that the boundary layers grow inward from the walls and eventually meet. Once they overlap, the flow and heat-transfer behavior are different from flow over an external surface.

  8. Maria

    Let’s begin with the hydrodynamic boundary layer, the one that describes how velocity changes near the wall. At the duct entrance, the fluid has a core moving at its entrance velocity, while boundary layers develop along the walls. As those layers grow, the core gets narrower until the layers meet.

  9. Anna

    The distance from the entrance to the point where the velocity profile becomes fully developed is the hydrodynamic entrance length, written x sub FD,h. Before that point, the velocity profile is developing. Beyond it, the profile no longer changes with distance down the pipe.

  10. Maria

    For laminar flow in a pipe, the fully developed velocity profile is the familiar parabolic shape. In other words, the velocity varies across the pipe, but that shape stays the same as you move farther downstream.

  11. Anna

    There’s a parallel idea for temperature. If fluid enters at one temperature and the pipe wall is at a different temperature, thermal boundary layers develop from the walls and change the fluid temperature near them. The distance to a fully developed temperature profile is called the thermal entrance length, x sub FD,t.

  12. Maria

    In the thermal entrance region, the temperature profile is still developing. Once the flow is thermally fully developed, its profile no longer changes with position down the pipe. The actual profile depends on the wall boundary condition.

  13. Anna

    For example, a constant wall temperature and a constant wall heat flux produce different temperature profiles. With constant heat flux, the temperature gradient at the wall is set by that heat flux. With constant wall temperature, the wall temperature stays fixed, and the profile has a different shape.

  14. Maria

    That distinction matters because the hydrodynamic and thermal entrance lengths do not have to be equal. The Prandtl number helps compare the momentum and thermal diffusivities, and therefore gives us a sense of the relative development of the velocity and temperature boundary layers.

  15. Anna

    If the Prandtl number is much greater than one, as for oil, the hydrodynamic boundary layer is smaller than the thermal boundary layer. If it’s near one, as for air, the two entrance lengths are similar. If it’s much less than one, as for mercury, the hydrodynamic entrance length is much larger than the thermal one.

  16. Maria

    The heat-transfer coefficient changes while the flow is developing, then becomes constant once the flow is fully developed. There’s a similar pattern for the friction coefficient: it changes in the entrance region and remains constant in the fully developed region.

  17. Anna

    For laminar flow, the hydrodynamic entrance length is approximately 0.05 times the Reynolds number times the pipe diameter. The thermal entrance length is that hydrodynamic length multiplied by the Prandtl number. So if you already know the laminar hydrodynamic entrance length, the Prandtl number gives you the corresponding thermal length.

  18. Maria

    For turbulent flow, the lecture uses a simpler guideline: both the hydrodynamic and thermal flow are treated as fully developed after about ten pipe diameters. The idea is that turbulent mixing makes their entrance lengths effectively the same for this estimate.

  19. Anna

    Now, how do we choose the fluid properties used in our calculations? For internal flow, we evaluate them at the average of the inlet and outlet fluid temperatures: inlet temperature plus outlet temperature, divided by two.

  20. Maria

    If both temperatures are known, that’s straightforward. If the outlet temperature is unknown, we can guess it, calculate the average temperature and properties, solve the problem, and check whether the resulting outlet temperature agrees with our guess. We can update the guess and repeat if greater accuracy is needed.

  21. Anna

    In many course problems, property values don’t change dramatically with temperature, so iteration may not be necessary. Whether it matters depends on the application and the accuracy you need.

  22. Maria

    The overall workflow is much like external convection. Establish the geometry and boundary conditions, find the relevant properties, determine whether the flow is laminar or turbulent, decide whether it’s fully developed, and then choose an appropriate convection correlation to find the heat-transfer coefficient, h.

  23. Anna

    For Reynolds number, use the pipe diameter as the characteristic length in a circular tube. For a noncircular duct, use the hydraulic diameter instead. And remember that the transition guideline depends on geometry: for a tube, the usual threshold is about 2,300, not the flat-plate value of about 500,000.

  24. Maria

    For a circular tube with laminar, fully developed flow, the Nusselt number is a constant determined by the wall condition. It is 4.36 for constant heat flux and 3.66 for constant wall temperature. Since Nusselt number equals h times diameter divided by fluid thermal conductivity, either value can be used to find h if the diameter and conductivity are known.

  25. Anna

    For turbulent flow in a smooth pipe, the commonly used correlation in this lecture has Nusselt number equal to 0.023 times Reynolds number to the power 0.8, times Prandtl number to the power n. The exponent n depends on whether the fluid is being heated or cooled.

  26. Maria

    If the fluid is warmer than the surface and is being cooled, use n equal to 0.3. If the surface is warmer than the fluid and the fluid is being heated, use n equal to 0.4. In this course, if the problem doesn’t specify a rough pipe, the instructor says to treat it as smooth.

  27. Anna

    If the pipe is in the developing region rather than fully developed, the Nusselt number is not constant in the same way. You can use a table or a developing-flow correlation involving the Graetz number. Most of the problems in this course are expected to use fully developed flow, but it’s important to recognize when that assumption doesn’t apply.

  28. Maria

    For a duct that isn’t circular, the hydraulic diameter is four times the cross-sectional area divided by the wetted perimeter: D sub h equals 4A over P. The wetted perimeter is the part of the boundary in contact with the fluid.

  29. Anna

    Use that hydraulic diameter in definitions such as Reynolds number and Nusselt number. For laminar flow in a rectangular duct, the fully developed Nusselt number depends on the rectangle’s aspect ratio and on whether the wall condition is constant temperature or constant heat flux. You select the appropriate value from the relevant table.

  30. Maria

    For turbulent flow in a noncircular duct, the lecture uses the same turbulent Nusselt correlation as for a circular pipe, but substitutes hydraulic diameter for pipe diameter. Again, choose the exponent according to whether the fluid is being heated or cooled.

  31. Anna

    Let’s connect those correlations to energy balances. With constant heat flux, the heat added to the fluid over a distance x is the heat flux times the wall area over that length. For a duct with wetted perimeter P, that is q double-prime times P times x.

  32. Maria

    A steady-flow energy balance says that this heat equals the fluid’s mass flow rate times its specific heat times its temperature rise. So q double-prime P x equals m dot c sub p times the difference between the fluid temperature at x and its inlet temperature.

  33. Anna

    That equation lets us find the fluid temperature at a particular position. If we’re analyzing the whole pipe, use its full length L; if we want a temperature partway along, use that position x.

  34. Maria

    If the flow is fully developed and the heat flux is constant, the temperature difference between the wall and the fluid is also consistent with the heat-transfer relation: heat flux equals h times the wall-to-fluid temperature difference. That gives us a way to find the wall temperature once we know the fluid temperature and h.

  35. Anna

    A constant wall temperature leads to a different relationship. The difference between wall temperature and fluid temperature decreases along the pipe according to an exponential relation: the temperature difference at x divided by the inlet temperature difference equals the exponential of negative h P x divided by m dot c sub p.

  36. Maria

    So, in symbols, that ratio is exp of minus h P x over m dot c sub p. The P is the wetted perimeter, and x is the distance along the pipe. This relation is useful when the wall temperature is fixed and you want the fluid temperature downstream.

  37. Anna

    To calculate the heat transfer for a constant-temperature wall, we can use a steady-flow energy balance, q equals m dot c sub p times the fluid temperature change. We can also express it with Newton’s law of cooling, using h times area times a log-mean temperature difference.

  38. Maria

    The log-mean temperature difference uses the wall-to-fluid temperature difference at the inlet and the corresponding difference at position x. It is the difference between those two temperature differences divided by the natural logarithm of their ratio. For total heat transfer through the pipe, set x equal to L.

  39. Anna

    Be careful with temperature units. Temperature differences can be expressed in Celsius or Kelvin, but a temperature used as an absolute temperature must be on an absolute scale. When there’s any doubt, doing the calculation in Kelvin is a safe approach.

  40. Maria

    Let’s work through the example from the lecture. Compressed air flows through a two-meter-long tube with an inner diameter of 10 millimeters. The wall is maintained at 45 degrees Celsius, the inlet air is at 125 degrees Celsius, and the problem provides the flow rate and fluid properties.

  41. Anna

    Because the wall is cooler than the entering air, the air should cool as it travels through the tube. The given boundary condition is constant wall temperature. The solution also assumes steady state, constant fluid properties, and no heat loss to the surroundings.

  42. Maria

    First, convert the mass flow rate into kilograms per second if it’s given in kilograms per hour. Convert the diameter into meters too: 10 millimeters is 0.01 meters. Doing these conversions early helps avoid mixing units later.

  43. Anna

    Next, find the Reynolds number. The problem gives mass flow rate rather than velocity, so calculate the average velocity from mass flow rate divided by density and cross-sectional area. Then use that velocity, the diameter, the density, and the viscosity in the Reynolds number.

  44. Maria

    The calculated Reynolds number is about 60,000. Since the tube-flow transition guideline is around 2,300, this is turbulent flow. That immediately tells us to use turbulent-flow entrance and heat-transfer guidelines.

  45. Anna

    Ten diameters is 10 times 0.01 meters, or 0.1 meters. The pipe is two meters long, so the outlet is well beyond that approximate turbulent entrance length and the flow is treated as fully developed there.

  46. Maria

    For the smooth-pipe turbulent correlation, the fluid is being cooled because it is hotter than the wall. Therefore, choose n equal to 0.3. Using the properties supplied in the problem, the Nusselt number is about 137.3.

  47. Anna

    Then use the Nusselt number definition, h times diameter divided by thermal conductivity, to solve for h. The example gives a convection coefficient of about 466.8 watts per square meter-kelvin.

  48. Maria

    Finally, use the constant-wall-temperature exponential relation at x equal to the full pipe length. The resulting ratio of wall-to-fluid temperature differences is about 0.074.

  49. Anna

    The inlet temperature difference from the wall is 125 minus 45, or 80 degrees. At the outlet, the wall-to-fluid difference is about 0.074 times 80, which is about 5.9 degrees. Since the wall is at 45 degrees Celsius, the outlet air temperature is about 51 degrees Celsius.

  50. Maria

    That example brings the method together: identify the geometry and boundary condition, determine the flow regime, check development length, select the right Nusselt correlation, find h, and then apply the appropriate energy or temperature relation.

  51. Anna

    And the key distinction to keep in mind is that internal convection has both hydrodynamic and thermal development, with potentially different entrance lengths. Once each profile is fully developed, the relevant profile no longer changes along the pipe, and the fully developed correlations become available.

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent