Grid Integration in California
- 85Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
85 questions
- 1The California low-carbon grid study evaluated whether the electric sector could reduce carbon emissions by 50 percent below_____levels by 2030.
Hint
The study used a historical emissions baseline.
Answer
2012
- 2The study examined both economic effects and the grid_____challenges associated with high renewable penetration.
Hint
These challenges concern fitting variable renewable generation into power-system operation.
Answer
integration
- 3The independent technical review committee was separate from the study's_____and reviewed assumptions and methods.
Hint
This committee was not made up of the organizations financing the study.
Answer
funders
- 4The study's final report and conclusions represented the_____rather than necessarily reflecting each sponsoring organization's interpretation.
Hint
This was the group that conducted and reported the analysis.
Answer
study team
- 5The baseline portfolio was based on California's 2014 long-term procurement planning process and its_____percent case.
Hint
This baseline preceded California's move to a 50 percent renewable portfolio standard.
Answer
33
- 6The two target portfolios reached approximately_____to 57 percent renewable penetration and were designed to achieve the carbon-reduction target.
Hint
The target portfolios exceeded the 50 percent renewable level.
Answer
55
- 7Compared with the high-solar portfolio, the target_____portfolio used a broader mix of renewable resources.
Hint
This portfolio traded some photovoltaic generation for other renewable technologies.
Answer
diverse
- 8In the diverse target portfolio, some photovoltaics were replaced mainly by out-of-state wind, in-state_____and a small amount of biomass.
Hint
This renewable resource uses heat from beneath Earth's surface.
Answer
geothermal
- 9All the study portfolios assumed the same rooftop photovoltaic generation of_____terawatt-hours.
Hint
This rooftop generation assumption did not vary between portfolios.
Answer
24
- 10The baseline differed from the target portfolios by about 20 terawatt-hours of_____.
Hint
This reduces the amount of energy needed rather than supplying new generation.
Answer
energy efficiency
- 11Additional offshore wind was excluded partly because floating platforms were considered_____in the near term.
Hint
The stated barrier concerned whether the technology was affordable soon enough.
Answer
cost prohibitive
- 12Under conventional flexibility, 70 percent of specified out-of-state renewable generation, Palo Verde nuclear power, and Hoover hydro had to be_____by California every hour.
Hint
The rule imposed a minimum share of this generation that had to flow into California.
Answer
imported
- 13The conventional 70 percent import requirement served partly as a proxy for California's_____rules.
Hint
These rules relate to how imported renewable energy is categorized.
Answer
bucket
- 14In the enhanced flexibility case, imports and exports faced physical limits but no requirement that specified energy be_____.
Hint
The enhanced case removed the mandatory flow direction while retaining physical constraints.
Answer
imported
- 15The conventional case required at least 25 percent local generation in California balancing authorities, supplied by local fossil fuels and_____.
Hint
This is the other local resource type named alongside fossil fuels.
Answer
hydro
- 16The enhanced flexibility case removed the requirement for_____generation within California balancing authorities.
Hint
The removed rule specified where a minimum amount of generation had to come from.
Answer
local
- 17The conventional flexibility case included approximately 1.5 gigawatts of battery storage to meet the_____requirement.
Hint
The initials refer to California's public utilities regulator.
Answer
CPUC
- 18Beyond the battery storage, enhanced flexibility added 1 gigawatt of new_____hydro in California.
Hint
This storage method moves water uphill when electricity is available.
Answer
pumped
- 19Enhanced flexibility also added 1.2 gigawatts of out-of-state compressed air energy storage near Delta, Utah, at the site of the_____project mine.
Hint
The storage was associated with the named power project near Delta.
Answer
Intermountain Power
- 20In the conventional case, hydro and pumped-storage capacity for ancillary services was calibrated to approximate provision in_____.
Hint
This was the historical year used to tune the model.
Answer
2013
- 21Compared with conventional flexibility, enhanced flexibility placed less strict limits on hydro and pumped storage providing_____services.
Hint
These services support reliable grid operation beyond supplying energy.
Answer
ancillary
- 22The combined impacts of the four flexibility assumptions could be greater than the sum of their_____impacts.
Hint
The presenter emphasized that combining constraints can amplify their effects.
Answer
individual
- 23The conventional flexibility assumptions represented an increase in flexibility beyond what the grid had_____at the time.
Hint
The comparison was with conditions when the study was being conducted.
Answer
today
- 24The model used optimal west-wide dispatch, with_____rates constraining power flows and the degree of optimization between regions.
Hint
These rates create friction for transfers between areas.
Answer
hurdle
- 25The study assumed retirement of Diablo Canyon, a zero-carbon resource, which could make meeting the emissions target easier but increase_____challenges.
Hint
Replacing the retired plant with more renewables could make system operation more challenging.
Answer
integration
- 26The study assumed 3 million electric vehicles, adding 13 terawatt-hours of load and potentially up to 3,000 megawatts of_____load.
Hint
This load could be shifted to times when renewable energy would otherwise be curtailed.
Answer
additional
- 27The target portfolio cases included a north-south transmission line from Idaho to Southern Nevada that approximately imitated the_____line.
Hint
The modeled transmission addition was described as resembling a named northbound project.
Answer
SWIP North
- 28The target portfolio cases also assumed transmission from New Mexico to connect generation to the_____River Pact.
Hint
This was the regional transmission area named in the study.
Answer
Western
- 29The study modeled 23 different scenarios, varying resource investments and operational or_____conditions.
Hint
These conditions include import rules, local generation rules, and scheduling flexibility.
Answer
institutional
- 30Demand-side flexibility sensitivity cases examined both higher and lower levels of_____response.
Hint
This grid resource changes or shifts electricity use.
Answer
demand
- 31Other sensitivities included high western renewable penetration, lower gas prices, higher CO2 prices, and wet-year or dry-year_____conditions.
Hint
These conditions concern the amount of water-related electricity generation available.
Answer
hydro
- 32All study scenarios achieved the 50 percent carbon-reduction target except the dry-hydro case with conventional grid_____.
Hint
This case combined limited water availability with the less adaptable of the two grid assumptions.
Answer
flexibility
- 33Enhanced flexibility produced lower emissions primarily because it reduced renewable_____and the need to operate fossil-fuel generation to replace curtailed energy.
Hint
This occurs when available renewable electricity cannot be used.
Answer
curtailment
- 34In the conventional flexibility case, the high-solar portfolio generally had more curtailment than the more_____portfolio.
Hint
This portfolio used a broader mix of renewable resources.
Answer
diverse
- 35The target portfolio reduced production costs by approximately 4.3 to 4.8 billion dollars, depending on the_____case.
Hint
The study compared different mixes of renewable resources.
Answer
portfolio
- 36In the baseline case, enhanced flexibility was worth about 65 million dollars per year in_____costs compared with conventional flexibility.
Hint
These are costs incurred while running the power system.
Answer
operation
- 37The value of flexibility was much greater in the target portfolio than in the baseline because renewable penetration exceeded_____percent.
Hint
At this approximate penetration threshold, the study found larger flexibility benefits.
Answer
50
- 38Under conventional flexibility, curtailment approached 10 percent in the_____portfolio.
Hint
This portfolio concentrated more of its renewable generation in photovoltaics.
Answer
high-solar
- 39In many more diverse and/or flexible scenarios, curtailment was below_____percent.
Hint
The study found very low curtailment in several of these cases.
Answer
1
- 40Combining less flexible institutions with a less diverse portfolio could raise operating costs by up to 800 million dollars and emissions by up to_____percent.
Hint
This was the reported upper increase in carbon emissions.
Answer
14
- 41The companion capital-cost analysis estimated annualized costs of about 5.1 billion dollars for incremental renewables, transmission, and storage in the target enhanced portfolio, about 230 million dollars more than the production-cost_____.
Hint
This was the operating-cost benefit against which the capital costs were compared.
Answer
reduction
- 42The companion capital-cost analysis estimated that the portfolio costs represented about 0.6 percent of California's annual revenue_____.
Hint
This is the total revenue utilities need to collect to cover system costs.
Answer
requirement
- 43The dynamic-stability companion study was qualitative and concluded that mitigation options could provide reliability at lower cost and emissions than relying on additional_____.
Hint
The alternative would discard renewable generation to address transient stability.
Answer
curtailment
- 44In power-system terms, over-generation occurs when the system has more energy than it knows what to_____.
Hint
The definition describes a surplus that cannot be absorbed or used.
Answer
do with
- 45Over-generation is associated not only with technical limits but also with economic and_____flexibility on the grid.
Hint
Rules and market arrangements can constrain how the system responds.
Answer
institutional
- 46A technically simple way to address over-generation is to curtail wind or large-scale solar, but this discards zero-cost, zero-carbon_____.
Hint
This is the renewable output that could otherwise serve demand.
Answer
energy
- 47Curtailing residential rooftop photovoltaics can become more complicated at very high penetration because those systems are more difficult to_____.
Hint
The issue is managing their output when generation exceeds what the grid can use.
Answer
control
- 48The duck curve's steep net-load rise occurs in the afternoon and evening as the_____begins to set.
Hint
The curve reflects falling solar output while demand remains.
Answer
Sun
- 49For a modeled March 29 day with 11 percent annual solar penetration, the thermal and hydro fleet could not ramp below a minimum of about_____megawatts.
Hint
This modeled floor was above the net load that the duck curve would otherwise suggest.
Answer
12,600
- 50On that March 29 case, approximately 5 percent of the potential generation from wind and solar was_____.
Hint
Some available renewable output could not be accommodated by the system.
Answer
curtailed
- 51Changing the existing pumped-hydro fleet's schedule to pump during the middle of the day avoided about a couple thousand megawatts of_____.
Hint
Pumping used some of the surplus midday renewable electricity.
Answer
curtailment
- 52Summer conditions had little or no curtailment in the modeled cases because air-conditioning demand kept electricity demand high during the_____.
Hint
This is when solar generation is typically greatest.
Answer
middle of the day
- 53At 20 percent solar penetration, the study estimated that only about 60 to 70 percent of incremental solar energy could be used, corresponding to 30 to 40 percent marginal_____.
Hint
This measures the unused share of the additional solar generation.
Answer
curtailment
- 54When curtailment causes less solar energy to be sold, the effective cost of the energy that is sold can_____.
Hint
The same investment cost is spread over fewer usable units of energy.
Answer
increase
- 55Fattening the duck means accommodating the solar-generation profile by reducing system minimum-generation_____.
Hint
This approach allows conventional resources to turn down further during sunny hours.
Answer
constraints
- 56Flattening the duck means shifting or adding demand in the middle of the day and using that demand_____.
Hint
The strategy moves consumption from solar-rich hours to a subsequent period.
Answer
later
- 57Adding the storage associated with California's mandate reduced instantaneous curtailment on the modeled day by a little over_____megawatts through load shifting.
Hint
This reduction was achieved by shifting demand from midday to later in the day.
Answer
1,000
- 58Local storage can provide operating reserves, frequency stability, and voltage stability, reducing the need to keep partially loaded_____generators for those services.
Hint
These conventional generators may otherwise be kept online for system support.
Answer
thermal
- 59When the modeled minimum-generation floor fell from 12,600 to about 10,000 megawatts, instantaneous curtailment on the study day fell from 7,000 megawatts to_____4,000 megawatts.
Hint
The result was lower than this rounded threshold.
Answer
under
- 60Besides storage and demand response, concentrating solar power with thermal storage and greater regional_____can help accommodate solar generation.
Hint
This means exchanging electricity more freely between regions.
Answer
interchange
- 61The analysis suggested that, with additional flexibility, solar penetration could reach roughly 20 to 25 percent with relatively low_____.
Hint
This is the renewable generation that cannot be used.
Answer
curtailment
- 62Combining accommodation of the duck's natural shape with demand shifting could support solar penetration of roughly 25 to 30_____.
Hint
The value is a share of the system's generation.
Answer
percent
- 63In the duck-curve analysis, Diablo Canyon was modeled as a base-load plant whose output did not_____.
Hint
The model did not ramp this nuclear plant's production.
Answer
change
- 64The duck-curve analysis used the hydro movement limits from the LTPP models because detailed hydro_____is important.
Hint
The speaker noted that accurately representing water-based generation requires this kind of analysis.
Answer
modeling
- 65California's storage mandate called for_____gigawatts of storage, with procurement timing and sector specified but storage technology not prescribed.
Hint
The mandate covered storage across transmission, distribution, and customer locations.
Answer
1.325
- 66The storage study used long-term procurement planning information and examined_____and 40 percent renewable-generation cases.
Hint
This was the lower of the two renewable-generation levels modeled.
Answer
33
- 67The production-cost model simulated unit commitment, energy dispatch, and provision of reserves at an_____time step.
Hint
The model represented operations one time interval per hour.
Answer
hourly
- 68To estimate storage revenues, the study also used a six-price optimization model based on_____prices.
Hint
These prices came from past market experience.
Answer
historical
- 69One storage comparison removed storage from California and the wider West, while another added it back according to the storage_____.
Hint
This was the required deployment level used in the base case.
Answer
mandate
- 70To isolate the sources of storage value, scenarios compared energy provision, ancillary-service provision, and provision of_____only.
Hint
This case restricted storage to a grid-support service rather than energy supply.
Answer
reserves
- 71Storage sensitivity cases varied regulation provision, storage duration, the value of curtailed energy, export limits, and storage_____.
Hint
This refers to testing different overall amounts of installed storage.
Answer
capacity
- 72The storage study also examined what happened if California's_____limitation was removed.
Hint
The sensitivity allowed California to send surplus energy out more freely.
Answer
export
- 73Adding storage reduced system-wide operating costs by approximately 78 to 144 million dollars across different renewable_____.
Hint
The result varied with the share of electricity supplied by renewables.
Answer
penetrations
- 74Avoided generator startup costs accounted for approximately 30 to 67 percent of the production-cost reduction, but storage did not currently receive payment for those costs in energy or other_____.
Hint
These are the settings in which generators or storage resources are compensated.
Answer
markets
- 75Providing ancillary services alone captured about_____percent of the modeled value of adding storage.
Hint
The study found that grid-support services accounted for most of the storage value.
Answer
90
- 76Adding optimized energy provision to ancillary services increased storage value by about a further_____percent.
Hint
This was the additional value beyond ancillary services alone.
Answer
10
- 77Ancillary-service markets can limit storage value because they are relatively_____and can become saturated.
Hint
There is only a limited amount of demand for these services in the market.
Answer
shallow
- 78Storage reduced emissions within California, but its effect on emissions across the entire West was_____.
Hint
The wider outcome depended on which generators supplied electricity to charge storage.
Answer
mixed
- 79As more storage is added, the value of each additional unit tends to be_____than that of the preceding unit.
Hint
The study found diminishing incremental value as storage capacity grew.
Answer
less
- 80The storage-duration sensitivity compared systems with two, four, and_____hours of storage.
Hint
This was the longest duration tested.
Answer
six
- 81In the regulation-only sensitivity, storage saturation produced zero prices in the model, a result the presenter cautioned might not occur the same way in actual_____.
Hint
The model's simplified price behavior may differ from real-world operation.
Answer
markets
- 82Removing California's export limitation reduced curtailment but also reduced storage value by relieving some system_____issues.
Hint
Freer regional exchange made the system less reliant on storage to balance supply and demand.
Answer
flexibility
- 83If the rest of the West also adds substantial renewables, California may have less ability to export surplus solar because neighboring regions receive solar generation at roughly the same_____.
Hint
The challenge is that generation surpluses could occur simultaneously across regions.
Answer
time
- 84As other western regions add renewables, the value of storage may_____because fewer regions will be available to absorb California's surplus energy.
Hint
Regional solar surpluses can become more synchronized as renewable deployment spreads.
Answer
increase
- 85Initial work on synchronous and nonsynchronous generation did not show a major inertia problem, but the presenter said more_____was needed for a precise answer.
Hint
The uncertainty remained and required further analysis.
Answer
work

Ask anything
We've read this whole study set, so questions about it get the best answers.