Grid Integration in California

  • 85Unfamiliar
  • 0Learning
  • 0Familiar
  • 0Mastered
Topic: Study Goals
The California low-carbon grid study evaluated whether the electric sector could reduce carbon emissions by 50 percent below
levels by 2030.

85 questions

  1. 1
    The California low-carbon grid study evaluated whether the electric sector could reduce carbon emissions by 50 percent below
    _____
    levels by 2030.
    Hint

    The study used a historical emissions baseline.

    Answer

    2012

  2. 2
    The study examined both economic effects and the grid
    _____
    challenges associated with high renewable penetration.
    Hint

    These challenges concern fitting variable renewable generation into power-system operation.

    Answer

    integration

  3. 3
    The independent technical review committee was separate from the study's
    _____
    and reviewed assumptions and methods.
    Hint

    This committee was not made up of the organizations financing the study.

    Answer

    funders

  4. 4
    The study's final report and conclusions represented the
    _____
    rather than necessarily reflecting each sponsoring organization's interpretation.
    Hint

    This was the group that conducted and reported the analysis.

    Answer

    study team

  5. 5
    The baseline portfolio was based on California's 2014 long-term procurement planning process and its
    _____
    percent case.
    Hint

    This baseline preceded California's move to a 50 percent renewable portfolio standard.

    Answer

    33

  6. 6
    The two target portfolios reached approximately
    _____
    to 57 percent renewable penetration and were designed to achieve the carbon-reduction target.
    Hint

    The target portfolios exceeded the 50 percent renewable level.

    Answer

    55

  7. 7
    Compared with the high-solar portfolio, the target
    _____
    portfolio used a broader mix of renewable resources.
    Hint

    This portfolio traded some photovoltaic generation for other renewable technologies.

    Answer

    diverse

  8. 8
    In the diverse target portfolio, some photovoltaics were replaced mainly by out-of-state wind, in-state
    _____
    and a small amount of biomass.
    Hint

    This renewable resource uses heat from beneath Earth's surface.

    Answer

    geothermal

  9. 9
    All the study portfolios assumed the same rooftop photovoltaic generation of
    _____
    terawatt-hours.
    Hint

    This rooftop generation assumption did not vary between portfolios.

    Answer

    24

  10. 10
    The baseline differed from the target portfolios by about 20 terawatt-hours of
    _____
    .
    Hint

    This reduces the amount of energy needed rather than supplying new generation.

    Answer

    energy efficiency

  11. 11
    Additional offshore wind was excluded partly because floating platforms were considered
    _____
    in the near term.
    Hint

    The stated barrier concerned whether the technology was affordable soon enough.

    Answer

    cost prohibitive

  12. 12
    Under conventional flexibility, 70 percent of specified out-of-state renewable generation, Palo Verde nuclear power, and Hoover hydro had to be
    _____
    by California every hour.
    Hint

    The rule imposed a minimum share of this generation that had to flow into California.

    Answer

    imported

  13. 13
    The conventional 70 percent import requirement served partly as a proxy for California's
    _____
    rules.
    Hint

    These rules relate to how imported renewable energy is categorized.

    Answer

    bucket

  14. 14
    In the enhanced flexibility case, imports and exports faced physical limits but no requirement that specified energy be
    _____
    .
    Hint

    The enhanced case removed the mandatory flow direction while retaining physical constraints.

    Answer

    imported

  15. 15
    The conventional case required at least 25 percent local generation in California balancing authorities, supplied by local fossil fuels and
    _____
    .
    Hint

    This is the other local resource type named alongside fossil fuels.

    Answer

    hydro

  16. 16
    The enhanced flexibility case removed the requirement for
    _____
    generation within California balancing authorities.
    Hint

    The removed rule specified where a minimum amount of generation had to come from.

    Answer

    local

  17. 17
    The conventional flexibility case included approximately 1.5 gigawatts of battery storage to meet the
    _____
    requirement.
    Hint

    The initials refer to California's public utilities regulator.

    Answer

    CPUC

  18. 18
    Beyond the battery storage, enhanced flexibility added 1 gigawatt of new
    _____
    hydro in California.
    Hint

    This storage method moves water uphill when electricity is available.

    Answer

    pumped

  19. 19
    Enhanced flexibility also added 1.2 gigawatts of out-of-state compressed air energy storage near Delta, Utah, at the site of the
    _____
    project mine.
    Hint

    The storage was associated with the named power project near Delta.

    Answer

    Intermountain Power

  20. 20
    In the conventional case, hydro and pumped-storage capacity for ancillary services was calibrated to approximate provision in
    _____
    .
    Hint

    This was the historical year used to tune the model.

    Answer

    2013

  21. 21
    Compared with conventional flexibility, enhanced flexibility placed less strict limits on hydro and pumped storage providing
    _____
    services.
    Hint

    These services support reliable grid operation beyond supplying energy.

    Answer

    ancillary

  22. 22
    The combined impacts of the four flexibility assumptions could be greater than the sum of their
    _____
    impacts.
    Hint

    The presenter emphasized that combining constraints can amplify their effects.

    Answer

    individual

  23. 23
    The conventional flexibility assumptions represented an increase in flexibility beyond what the grid had
    _____
    at the time.
    Hint

    The comparison was with conditions when the study was being conducted.

    Answer

    today

  24. 24
    The model used optimal west-wide dispatch, with
    _____
    rates constraining power flows and the degree of optimization between regions.
    Hint

    These rates create friction for transfers between areas.

    Answer

    hurdle

  25. 25
    The study assumed retirement of Diablo Canyon, a zero-carbon resource, which could make meeting the emissions target easier but increase
    _____
    challenges.
    Hint

    Replacing the retired plant with more renewables could make system operation more challenging.

    Answer

    integration

  26. 26
    The study assumed 3 million electric vehicles, adding 13 terawatt-hours of load and potentially up to 3,000 megawatts of
    _____
    load.
    Hint

    This load could be shifted to times when renewable energy would otherwise be curtailed.

    Answer

    additional

  27. 27
    The target portfolio cases included a north-south transmission line from Idaho to Southern Nevada that approximately imitated the
    _____
    line.
    Hint

    The modeled transmission addition was described as resembling a named northbound project.

    Answer

    SWIP North

  28. 28
    The target portfolio cases also assumed transmission from New Mexico to connect generation to the
    _____
    River Pact.
    Hint

    This was the regional transmission area named in the study.

    Answer

    Western

  29. 29
    The study modeled 23 different scenarios, varying resource investments and operational or
    _____
    conditions.
    Hint

    These conditions include import rules, local generation rules, and scheduling flexibility.

    Answer

    institutional

  30. 30
    Demand-side flexibility sensitivity cases examined both higher and lower levels of
    _____
    response.
    Hint

    This grid resource changes or shifts electricity use.

    Answer

    demand

  31. 31
    Other sensitivities included high western renewable penetration, lower gas prices, higher CO2 prices, and wet-year or dry-year
    _____
    conditions.
    Hint

    These conditions concern the amount of water-related electricity generation available.

    Answer

    hydro

  32. 32
    All study scenarios achieved the 50 percent carbon-reduction target except the dry-hydro case with conventional grid
    _____
    .
    Hint

    This case combined limited water availability with the less adaptable of the two grid assumptions.

    Answer

    flexibility

  33. 33
    Enhanced flexibility produced lower emissions primarily because it reduced renewable
    _____
    and the need to operate fossil-fuel generation to replace curtailed energy.
    Hint

    This occurs when available renewable electricity cannot be used.

    Answer

    curtailment

  34. 34
    In the conventional flexibility case, the high-solar portfolio generally had more curtailment than the more
    _____
    portfolio.
    Hint

    This portfolio used a broader mix of renewable resources.

    Answer

    diverse

  35. 35
    The target portfolio reduced production costs by approximately 4.3 to 4.8 billion dollars, depending on the
    _____
    case.
    Hint

    The study compared different mixes of renewable resources.

    Answer

    portfolio

  36. 36
    In the baseline case, enhanced flexibility was worth about 65 million dollars per year in
    _____
    costs compared with conventional flexibility.
    Hint

    These are costs incurred while running the power system.

    Answer

    operation

  37. 37
    The value of flexibility was much greater in the target portfolio than in the baseline because renewable penetration exceeded
    _____
    percent.
    Hint

    At this approximate penetration threshold, the study found larger flexibility benefits.

    Answer

    50

  38. 38
    Under conventional flexibility, curtailment approached 10 percent in the
    _____
    portfolio.
    Hint

    This portfolio concentrated more of its renewable generation in photovoltaics.

    Answer

    high-solar

  39. 39
    In many more diverse and/or flexible scenarios, curtailment was below
    _____
    percent.
    Hint

    The study found very low curtailment in several of these cases.

    Answer

    1

  40. 40
    Combining less flexible institutions with a less diverse portfolio could raise operating costs by up to 800 million dollars and emissions by up to
    _____
    percent.
    Hint

    This was the reported upper increase in carbon emissions.

    Answer

    14

  41. 41
    The companion capital-cost analysis estimated annualized costs of about 5.1 billion dollars for incremental renewables, transmission, and storage in the target enhanced portfolio, about 230 million dollars more than the production-cost
    _____
    .
    Hint

    This was the operating-cost benefit against which the capital costs were compared.

    Answer

    reduction

  42. 42
    The companion capital-cost analysis estimated that the portfolio costs represented about 0.6 percent of California's annual revenue
    _____
    .
    Hint

    This is the total revenue utilities need to collect to cover system costs.

    Answer

    requirement

  43. 43
    The dynamic-stability companion study was qualitative and concluded that mitigation options could provide reliability at lower cost and emissions than relying on additional
    _____
    .
    Hint

    The alternative would discard renewable generation to address transient stability.

    Answer

    curtailment

  44. 44
    In power-system terms, over-generation occurs when the system has more energy than it knows what to
    _____
    .
    Hint

    The definition describes a surplus that cannot be absorbed or used.

    Answer

    do with

  45. 45
    Over-generation is associated not only with technical limits but also with economic and
    _____
    flexibility on the grid.
    Hint

    Rules and market arrangements can constrain how the system responds.

    Answer

    institutional

  46. 46
    A technically simple way to address over-generation is to curtail wind or large-scale solar, but this discards zero-cost, zero-carbon
    _____
    .
    Hint

    This is the renewable output that could otherwise serve demand.

    Answer

    energy

  47. 47
    Curtailing residential rooftop photovoltaics can become more complicated at very high penetration because those systems are more difficult to
    _____
    .
    Hint

    The issue is managing their output when generation exceeds what the grid can use.

    Answer

    control

  48. 48
    The duck curve's steep net-load rise occurs in the afternoon and evening as the
    _____
    begins to set.
    Hint

    The curve reflects falling solar output while demand remains.

    Answer

    Sun

  49. 49
    For a modeled March 29 day with 11 percent annual solar penetration, the thermal and hydro fleet could not ramp below a minimum of about
    _____
    megawatts.
    Hint

    This modeled floor was above the net load that the duck curve would otherwise suggest.

    Answer

    12,600

  50. 50
    On that March 29 case, approximately 5 percent of the potential generation from wind and solar was
    _____
    .
    Hint

    Some available renewable output could not be accommodated by the system.

    Answer

    curtailed

  51. 51
    Changing the existing pumped-hydro fleet's schedule to pump during the middle of the day avoided about a couple thousand megawatts of
    _____
    .
    Hint

    Pumping used some of the surplus midday renewable electricity.

    Answer

    curtailment

  52. 52
    Summer conditions had little or no curtailment in the modeled cases because air-conditioning demand kept electricity demand high during the
    _____
    .
    Hint

    This is when solar generation is typically greatest.

    Answer

    middle of the day

  53. 53
    At 20 percent solar penetration, the study estimated that only about 60 to 70 percent of incremental solar energy could be used, corresponding to 30 to 40 percent marginal
    _____
    .
    Hint

    This measures the unused share of the additional solar generation.

    Answer

    curtailment

  54. 54
    When curtailment causes less solar energy to be sold, the effective cost of the energy that is sold can
    _____
    .
    Hint

    The same investment cost is spread over fewer usable units of energy.

    Answer

    increase

  55. 55
    Fattening the duck means accommodating the solar-generation profile by reducing system minimum-generation
    _____
    .
    Hint

    This approach allows conventional resources to turn down further during sunny hours.

    Answer

    constraints

  56. 56
    Flattening the duck means shifting or adding demand in the middle of the day and using that demand
    _____
    .
    Hint

    The strategy moves consumption from solar-rich hours to a subsequent period.

    Answer

    later

  57. 57
    Adding the storage associated with California's mandate reduced instantaneous curtailment on the modeled day by a little over
    _____
    megawatts through load shifting.
    Hint

    This reduction was achieved by shifting demand from midday to later in the day.

    Answer

    1,000

  58. 58
    Local storage can provide operating reserves, frequency stability, and voltage stability, reducing the need to keep partially loaded
    _____
    generators for those services.
    Hint

    These conventional generators may otherwise be kept online for system support.

    Answer

    thermal

  59. 59
    When the modeled minimum-generation floor fell from 12,600 to about 10,000 megawatts, instantaneous curtailment on the study day fell from 7,000 megawatts to
    _____
    4,000 megawatts.
    Hint

    The result was lower than this rounded threshold.

    Answer

    under

  60. 60
    Besides storage and demand response, concentrating solar power with thermal storage and greater regional
    _____
    can help accommodate solar generation.
    Hint

    This means exchanging electricity more freely between regions.

    Answer

    interchange

  61. 61
    The analysis suggested that, with additional flexibility, solar penetration could reach roughly 20 to 25 percent with relatively low
    _____
    .
    Hint

    This is the renewable generation that cannot be used.

    Answer

    curtailment

  62. 62
    Combining accommodation of the duck's natural shape with demand shifting could support solar penetration of roughly 25 to 30
    _____
    .
    Hint

    The value is a share of the system's generation.

    Answer

    percent

  63. 63
    In the duck-curve analysis, Diablo Canyon was modeled as a base-load plant whose output did not
    _____
    .
    Hint

    The model did not ramp this nuclear plant's production.

    Answer

    change

  64. 64
    The duck-curve analysis used the hydro movement limits from the LTPP models because detailed hydro
    _____
    is important.
    Hint

    The speaker noted that accurately representing water-based generation requires this kind of analysis.

    Answer

    modeling

  65. 65
    California's storage mandate called for
    _____
    gigawatts of storage, with procurement timing and sector specified but storage technology not prescribed.
    Hint

    The mandate covered storage across transmission, distribution, and customer locations.

    Answer

    1.325

  66. 66
    The storage study used long-term procurement planning information and examined
    _____
    and 40 percent renewable-generation cases.
    Hint

    This was the lower of the two renewable-generation levels modeled.

    Answer

    33

  67. 67
    The production-cost model simulated unit commitment, energy dispatch, and provision of reserves at an
    _____
    time step.
    Hint

    The model represented operations one time interval per hour.

    Answer

    hourly

  68. 68
    To estimate storage revenues, the study also used a six-price optimization model based on
    _____
    prices.
    Hint

    These prices came from past market experience.

    Answer

    historical

  69. 69
    One storage comparison removed storage from California and the wider West, while another added it back according to the storage
    _____
    .
    Hint

    This was the required deployment level used in the base case.

    Answer

    mandate

  70. 70
    To isolate the sources of storage value, scenarios compared energy provision, ancillary-service provision, and provision of
    _____
    only.
    Hint

    This case restricted storage to a grid-support service rather than energy supply.

    Answer

    reserves

  71. 71
    Storage sensitivity cases varied regulation provision, storage duration, the value of curtailed energy, export limits, and storage
    _____
    .
    Hint

    This refers to testing different overall amounts of installed storage.

    Answer

    capacity

  72. 72
    The storage study also examined what happened if California's
    _____
    limitation was removed.
    Hint

    The sensitivity allowed California to send surplus energy out more freely.

    Answer

    export

  73. 73
    Adding storage reduced system-wide operating costs by approximately 78 to 144 million dollars across different renewable
    _____
    .
    Hint

    The result varied with the share of electricity supplied by renewables.

    Answer

    penetrations

  74. 74
    Avoided generator startup costs accounted for approximately 30 to 67 percent of the production-cost reduction, but storage did not currently receive payment for those costs in energy or other
    _____
    .
    Hint

    These are the settings in which generators or storage resources are compensated.

    Answer

    markets

  75. 75
    Providing ancillary services alone captured about
    _____
    percent of the modeled value of adding storage.
    Hint

    The study found that grid-support services accounted for most of the storage value.

    Answer

    90

  76. 76
    Adding optimized energy provision to ancillary services increased storage value by about a further
    _____
    percent.
    Hint

    This was the additional value beyond ancillary services alone.

    Answer

    10

  77. 77
    Ancillary-service markets can limit storage value because they are relatively
    _____
    and can become saturated.
    Hint

    There is only a limited amount of demand for these services in the market.

    Answer

    shallow

  78. 78
    Storage reduced emissions within California, but its effect on emissions across the entire West was
    _____
    .
    Hint

    The wider outcome depended on which generators supplied electricity to charge storage.

    Answer

    mixed

  79. 79
    As more storage is added, the value of each additional unit tends to be
    _____
    than that of the preceding unit.
    Hint

    The study found diminishing incremental value as storage capacity grew.

    Answer

    less

  80. 80
    The storage-duration sensitivity compared systems with two, four, and
    _____
    hours of storage.
    Hint

    This was the longest duration tested.

    Answer

    six

  81. 81
    In the regulation-only sensitivity, storage saturation produced zero prices in the model, a result the presenter cautioned might not occur the same way in actual
    _____
    .
    Hint

    The model's simplified price behavior may differ from real-world operation.

    Answer

    markets

  82. 82
    Removing California's export limitation reduced curtailment but also reduced storage value by relieving some system
    _____
    issues.
    Hint

    Freer regional exchange made the system less reliant on storage to balance supply and demand.

    Answer

    flexibility

  83. 83
    If the rest of the West also adds substantial renewables, California may have less ability to export surplus solar because neighboring regions receive solar generation at roughly the same
    _____
    .
    Hint

    The challenge is that generation surpluses could occur simultaneously across regions.

    Answer

    time

  84. 84
    As other western regions add renewables, the value of storage may
    _____
    because fewer regions will be available to absorb California's surplus energy.
    Hint

    Regional solar surpluses can become more synchronized as renewable deployment spreads.

    Answer

    increase

  85. 85
    Initial work on synchronous and nonsynchronous generation did not show a major inertia problem, but the presenter said more
    _____
    was needed for a precise answer.
    Hint

    The uncertainty remained and required further analysis.

    Answer

    work