Determinants of Cardiac Output
- 24Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
24 questions
- 1The hydraulic model has two pumps in_____, just like the human cardiovascular system.
Hint
Think about how blood flows from one pump to the other in sequence.
Answer
series
- 2A standard roller pump used in cardiopulmonary bypass is an example of a_____pump.
Hint
This type of pump generates suction to refill its tubing.
Answer
sucking
- 3The output of a sucking pump is determined by pump speed, while the output of a non-sucking pump is controlled by_____factors.
Hint
External conditions like pressure in the system influence this pump's output.
Answer
systemic
- 4In the model, a low fluid volume causes low system pressure, mimicking a state of_____shock.
Hint
This type of shock results from inadequate blood volume.
Answer
hypovolemic
- 5Mean vascular pressure is the pressure in the vascular system with the heart stopped, after pressures have equilibrated between arteries, capillaries, and_____. It normally ranges from 16 to 18 mmHg.
Hint
Consider the three types of vessels in the circulatory system.
Answer
veins
- 6The two components of mean vascular pressure are fluid volume and system_____.
Hint
This property describes how easily a vessel stretches.
Answer
compliance
- 7Increasing fluid volume in the model increased flow, but the relationship was not_____.
Hint
Think about whether adding equal amounts caused equal increases in flow.
Answer
linear
- 8Decreasing system compliance by contracting the muscles around the beds causes an increase in_____.
Hint
This is directly observed on the manometer in the model.
Answer
pressure
- 9Adding a resistance at the_____of the pump had no effect on output as long as the pump was strong enough.
Hint
Consider which side of the pump was tested with a clamp.
Answer
outlet
- 10The term_____describes the combination of a resistance point and a distensible bed upstream that together impede flow to the pump inlet.
Hint
This concept combines resistance and compliance affecting inflow.
Answer
inlet impedance
- 11The_____minimizes inlet impedance by allowing uninterrupted venous flow during ventricular systole and unimpeded flow during diastole.
Hint
This chamber provides continuous inflow despite intermittent pumping.
Answer
atrium
- 12Although atrial displacement constitutes only_____% of the volume ejected per beat, the atrial effect enables four times the flow.
Hint
This is a specific percentage given in the content.
Answer
15
- 13A clinical corollary of increased inlet impedance is mitral stenosis, which reduces cardiac output by impeding flow into the_____.
Hint
Consider which chamber receives blood from the atrium.
Answer
ventricle
- 14During pump energy excess, increasing heart rate or strength of contraction does_____increase cardiac output.
Hint
Think about whether the pump's energy is already sufficient.
Answer
not
- 15Pump energy failure is a state where the pump is not expending sufficient energy to prevent the ventricles from filling completely before the end of_____.
Hint
Consider the phase of the cardiac cycle when filling occurs.
Answer
diastole
- 16One determinant of cardiac output during myocardial energy failure is_____.
Hint
Think about what was changed in the model when the pump was in failure (e.g., low rate).
Answer
rate
- 17The other determinant of cardiac output during myocardial energy failure is insufficient strength of contraction to overcome_____impedance.
Hint
Consider which type of impedance limits emptying of the ventricles.
Answer
outlet
- 18Starling's Law applies only during myocardial_____.
Hint
Recall the condition under which increased filling leads to increased contraction strength.
Answer
energy failure
- 19Poiseuille's Law, which expresses outlet resistance as a determinant of cardiac output, is valid only during myocardial_____.
Hint
This law applies when the heart is not in energy excess.
Answer
energy failure
- 20At a rate of 20 to 30 beats per minute, complete heart block is a clinical example of myocardial_____.
Hint
Low rate leads to insufficient energy to prevent complete filling.
Answer
energy failure
- 21The human heart is a non-sucking, intermittent outflow, continuous_____pump.
Hint
Consider how blood enters the heart continuously despite intermittent ejection.
Answer
inflow
- 22In the model, a clinical corollary of reduced inlet impedance is an_____fistula that bypasses the compliant bed.
Hint
This abnormal connection allows blood to bypass capillaries.
Answer
arterial-venous
- 23Exercise increases cardiac output by using muscle-vein pumps to force fluid past_____resistance points.
Hint
Consider which type of resistance impedes inflow to the heart.
Answer
inlet
- 24When the pump is in energy excess, the potential limiting factor for cardiac output is either mean vascular pressure or_____.
Hint
These two factors determine output when the pump has excess energy.
Answer
inlet impedance