Determinants of Cardiac Output

  • 25Unfamiliar
  • 0Learning
  • 0Familiar
  • 0Mastered
Topic: Hydraulic Model Overview
  • spaceFlip card
  • KI knew it
  • DI didn't know it
  • ←Previous card
  • →Next card

What is the key feature of the hydraulic model that allows it to mimic physiologic responses?

Tap to flipClick to flipspace

The pump, which is a non-sucking pump that fills passively, replicating the heart's behavior.

Or swipe the card

25 cards

  1. What is the key feature of the hydraulic model that allows it to mimic physiologic responses?

    The pump, which is a non-sucking pump that fills passively, replicating the heart's behavior.

  2. How are the two pumps in the hydraulic model connected to mimic the human cardiovascular system?

    They are in series: systemic circuit (left pump to aorta to capillaries to veins to right pump) and pulmonary circuit (right pump to pulmonary artery to capillaries to left pump).

  3. How does a sucking pump (roller pump) determine its output?

    Output = stroke rate × stroke volume; it is controlled by pump speed and does not depend on systemic pressure.

  4. How does raising the fluid container above a sucking pump affect its output?

    It does not alter the output; the pump determines flow regardless of hydrostatic pressure.

  5. What condition is necessary for a non-sucking pump to produce flow?

    The pressure in the system must be above pump level so that fluid passively fills the ventricle.

  6. In a non-sucking pump, what controls the flow?

    The amount of pressure in the system; increasing pressure increases flow, decreasing pressure decreases flow.

  7. What is mean vascular pressure?

    The pressure in the vascular system with the heart stopped, after pressures have equilibrated between arteries, capillaries, and veins.

  8. What are the two components that determine mean vascular pressure?

    Fluid volume and system compliance.

  9. How does adding fluid volume to the model affect cardiac output?

    It increases mean vascular pressure, which increases flow; the relationship is nonlinear (later additions have a greater effect).

  10. How does changing system compliance affect mean vascular pressure and cardiac output?

    Decreasing compliance (e.g., pressing on compliant beds) increases pressure and flow; increasing compliance (e.g., vasodilation) decreases pressure and flow.

  11. What is the clinical correlate of decreasing vascular compliance?

    Vasopressors increase cardiac output by decreasing vascular compliance, which raises mean vascular pressure.

  12. What is the clinical correlate of increasing vascular compliance?

    Spinal anesthesia and vasodilators decrease cardiac output by increasing vascular compliance, which lowers mean vascular pressure.

  13. What is inlet impedance?

    A combination of a resistance point and the vascular distensibility upstream from that resistance point that impedes flow to the pump inlet.

  14. Why does resistance at the pump inlet decrease output, but resistance at the outlet may not?

    Inlet resistance has a large compliant bed upstream that stores potential energy, reducing kinetic energy to force fluid past the resistance. Outlet resistance has little distensible bed upstream, so kinetic energy is available.

  15. What is the role of the atrium in minimizing inlet impedance?

    The atrium allows continuous venous inflow during ventricular systole and unimpeded flow into the ventricle during diastole, preventing pulsatile inflow that would reduce flow.

  16. List four clinical conditions that increase inlet impedance and reduce cardiac output.

    Mitral stenosis, venous obstruction, atrial fibrillation, and cardiac tamponade (also nodal rhythm, ventricular non-compliance, extremely rapid heart rate).

  17. List two clinical conditions that reduce inlet impedance and increase cardiac output.

    Arteriovenous fistula and exercise (muscle-vein pumps force fluid past inlet resistance points).

  18. What is pump energy excess?

    A state where the pump expends more energy than needed to eject the fluid from the ventricles; the ventricles do not fill completely before the end of diastole.

  19. What is pump energy failure?

    A state where the pump does not expend sufficient energy to prevent the ventricles from filling completely before the end of diastole.

  20. How does the effect of heart rate differ between energy excess and energy failure?

    In energy excess, increasing rate does not increase output; in energy failure, increasing rate increases output until the heart returns to energy excess.

  21. When does Starling's Law (greater diastolic filling → stronger contraction) primarily determine cardiac output?

    Only during myocardial energy failure.

  22. When does Poiseuille's Law (outlet resistance as a determinant of flow) apply to cardiac output?

    Only during myocardial energy failure.

  23. What are the two sets of determinants of cardiac output?

    1. During energy excess: mean vascular pressure (volume and compliance) and inlet impedance. 2) During energy failure: rate and contractility (to overcome outlet impedance).
  24. Why does increasing heart rate or contractility not improve cardiac output in hypovolemic shock?

    Because the mean vascular pressure is too low (due to low volume) to fill the non-sucking heart; the heart is in energy excess but lacks filling pressure.

  25. What is the evidence that the human heart is a non-sucking, intermittent outflow, continuous inflow pump?

    All available data from human physiologic experience correlates with the model findings.