Determinants of Cardiac Output
- 23Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
Compare the output control of a sucking pump versus a non-sucking pump.
23 questions
- 1
Compare the output control of a sucking pump versus a non-sucking pump.
Model answer
Output of a sucking pump is controlled by pump factors (speed and stroke volume), while output of a non-sucking pump is controlled by systemic factors (pressure in the system).
Explanation
A sucking pump (e.g., roller pump) actively refills by suction, so its output depends solely on pump speed and stroke volume, independent of external pressure. A non-sucking pump (like the model's ventricle) cannot suck to fill; it requires positive pressure in the system to push fluid in, so output depends on systemic pressure.
- 2
What is required for a non-sucking pump to produce flow?
Model answer
A non-sucking pump requires positive pressure in the system (above pump level) to force fluid into the ventricles.
Explanation
Without suction, the ventricle fills passively only when the pressure in the vascular system exceeds the pressure at the pump inlet. If pressure is too low, as in hypovolemic shock, no flow occurs regardless of pump rate or contraction strength.
- 3
Define mean vascular pressure.
Model answer
Mean vascular pressure is the pressure in the vascular system with the heart stopped, after pressures have equilibrated between arteries, capillaries, and veins.
Explanation
This concept, first described by Weber in 1863, represents the driving pressure that forces blood into the non-sucking heart. It is determined by blood volume and vascular compliance.
- 4
What are the two components that determine mean vascular pressure?
Model answer
Mean vascular pressure is determined by fluid volume and system compliance.
Explanation
Pressure in any hydraulic system equals volume divided by compliance. Increasing volume or decreasing compliance raises mean vascular pressure, while decreasing volume or increasing compliance lowers it.
- 5
What is the normal range of mean vascular pressure?
Model answer
Mean vascular pressure is normally between 16 and 18 mmHg above mid-heart level.
Explanation
It can be higher (20–30 mmHg) in high output states or lower (6–8 mmHg) in shock states.
- 6
How does decreasing vascular compliance affect cardiac output?
Model answer
Decreasing vascular compliance (e.g., by contracting muscles around compliant beds) increases pressure and thus increases flow, as demonstrated in the model.
Explanation
In human physiology, vasopressors increase cardiac output by decreasing vascular compliance, while spinal anesthesia and vasodilators increase compliance and decrease output.
- 7
How does increased fluid volume affect flow in the model?
Model answer
Increasing fluid volume raises mean vascular pressure and flow, but the relationship is non-linear; additional volume becomes more effective once a threshold is reached.
Explanation
In the model, the first 250 mL did not increase flow, but subsequent additions caused progressively larger increases in flow (e.g., from 1.5 to 4 L/min) due to higher pressure above pump level.
- 8
What is inlet impedance, and how does it differ from total vascular resistance?
Model answer
Inlet impedance is the combination of a resistance point and a distensible bed upstream from that resistance, which together impede flow to the pump inlet. Total vascular resistance alone is not a determinant of cardiac output.
Explanation
Outlet resistance (e.g., aortic stenosis) does not decrease output if the pump is strong, because little compliant bed is upstream. But inlet resistance with a large compliant bed upstream stores potential energy, reducing kinetic energy available to push fluid past the resistance, thus decreasing output.
- 9
Why does outlet resistance not decrease pump output as long as the pump is strong?
Model answer
Outlet resistance does not decrease output because there is very little distensible bed upstream of the resistance, so kinetic energy is not stored and the pump can force fluid past it.
Explanation
In the model, adding a clamp on the outlet (arterial side) increased pressure but flow remained unchanged (4.5 L/min) because the pump had enough energy to overcome the resistance. Clinically, aortic stenosis or hypertension does not reduce cardiac output if the heart is strong.
- 10
Why does inlet resistance with a compliant bed upstream decrease pump output?
Model answer
The compliant bed upstream stores potential energy from pump ejection, reducing kinetic energy available to push fluid past the resistance, so the pump cannot fill adequately and output decreases.
Explanation
In the model, adding a clamp on the inlet (venous side) dramatically reduced flow because the upstream compliant bed (capillary bed) absorbed energy, unlike the outlet side where no such compliant bed existed.
- 11
What is the role of the atrium in minimizing inlet impedance?
Model answer
The atrium allows uninterrupted venous flow during ventricular systole (by being empty and distensible) and unimpeded flow into the ventricle during diastole, thereby minimizing inlet impedance.
Explanation
Atrial contraction contributes only 15% of ventricular volume but increases flow by four times compared to no atrium, because it prevents the inertia of starting and stopping flow to the intermittent pump.
- 12
How much of the ventricular volume is displaced by atrial contraction?
Model answer
Atrial contraction displaces only 15% of the volume ejected by the ventricle at each beat.
Explanation
Despite this small volume, the atrial effect makes possible four times the flow that would occur without some mechanism to maintain continuous inflow during ventricular systole.
- 13
Name three clinical conditions that increase inlet impedance and reduce cardiac output.
Model answer
Mitral stenosis, venous obstruction, atrial fibrillation, nodal rhythm, cardiac tamponade, ventricular non-compliance, and extremely rapid heart rate (any three).
Explanation
These conditions either obstruct inflow (stenosis, obstruction), impair atrial function (fibrillation, nodal rhythm), compress the heart (tamponade), reduce ventricular filling (non-compliance), or shorten diastole (rapid rate), all increasing inlet impedance.
- 14
What is pump energy excess?
Model answer
Pump energy excess is a state where the pump is expending more energy than needed to eject fluid from the ventricles, so the ventricles do not fill completely and determinants of output are mean vascular pressure and inlet impedance.
Explanation
In this state, increasing rate or strength of contraction does not increase output (as seen with therapeutic propranolol or hand-cranking the model). Normal hearts operate in energy excess during daily living.
- 15
What are the determinants of cardiac output during pump energy excess?
Model answer
During pump energy excess, cardiac output is determined by mean vascular pressure (volume and compliance) and inlet impedance (resistance with upstream distensible bed).
Explanation
Rate and contractility have no effect because the pump already has excess energy; output is limited by how much fluid can enter the ventricle (influenced by pressure and inlet impedance).
- 16
What is pump energy failure?
Model answer
Pump energy failure is a state where the pump is not expending sufficient energy to prevent the ventricles from filling completely before the end of diastole.
Explanation
This is distinct from congestive heart failure. In energy failure, the ventricles fill completely, so output becomes limited by rate and/or the ability to overcome outlet impedance.
- 17
What are the determinants of cardiac output during pump energy failure?
Model answer
During pump energy failure, cardiac output is determined by heart rate and the strength of myocardial contraction (specifically, the ability to overcome outlet impedance).
Explanation
When ventricles fill completely, increasing rate increases output until the pump returns to energy excess. If contraction is too weak to overcome outlet impedance, output decreases due to incomplete emptying and reduced filling.
- 18
Under what condition does increasing heart rate increase cardiac output?
Model answer
Increasing heart rate increases cardiac output only during pump energy failure (when ventricles are filling completely, e.g., in complete heart block at 20–30 bpm).
Explanation
In energy excess, increasing rate does not change output because the ventricles are not filling completely. In energy failure, rate is a limiting factor up to the point where filling becomes complete again (around 70 bpm).
- 19
How does insufficient strength of contraction affect output in the model?
Model answer
Insufficient contraction strength (simulated by manual compression) fails to overcome outlet impedance, leading to incomplete emptying, complete filling, and reduced inflow/output.
Explanation
Even if mean vascular pressure and inlet impedance are normal, a weak contraction cannot fully eject the ventricle against resistance, causing the ventricle to fill completely and limit subsequent filling, thus decreasing output.
- 20
Under what condition does Starling's Law (greater filling → greater contraction) apply as a determinant of cardiac output?
Model answer
Starling's Law applies as a determinant of cardiac output only during myocardial energy failure.
Explanation
During energy excess, the heart does not rely on filling to increase contraction; Starling's Law serves only for energy conservation. In energy failure, increased filling stretches the myocardium and enhances contraction to improve output.
- 21
Under what condition does Poiseuille's Law (outlet resistance determines output) apply?
Model answer
Poiseuille's Law applies as a determinant of cardiac output only during myocardial energy failure.
Explanation
In energy excess, outlet resistance does not affect output because the pump is strong enough to overcome it; it merely creates a pressure gradient. In energy failure, weak contraction makes outlet resistance a limiting factor.
- 22
What type of pump is the human heart?
Model answer
The human heart is a non-sucking, intermittent outflow, continuous inflow pump.
Explanation
Evidence from the hydraulic model and clinical correlations indicates that the heart behaves like the non-sucking pump: it does not suck to fill, ejects intermittently, but receives continuous inflow (facilitated by the atria).
- 23
How many sets of determinants of cardiac output exist, and what determines which set is operative?
Model answer
Two sets exist: one for energy excess (mean vascular pressure and inlet impedance) and one for energy failure (rate and contraction strength). The set that potentially limits output the most is operative at any time.
Explanation
The heart switches between these sets based on whether it is in energy excess or failure. For example, in hypovolemic shock (energy excess), increasing volume helps; in complete heart block (energy failure), increasing rate helps.