Determinants of Cardiac Output

Determinants of Cardiac Output

Introduction to the Hydraulic Model

A hydraulic model of the cardiovascular system allows direct observation of phenomena that can only be measured indirectly in the human body. The model replicates physiologic responses because of a special component: the pump, which serves as a homologue of the heart.

The model contains two pumps, each with a ventricle, an inlet valve, an outlet valve, and an atrium. The left pump connects to a simulated aorta, through which fluid flows to systemic arterioles, a distensible capillary bed, then into venioles, a vena cava, and back to the right heart pump. The pulmonary circuit follows a similar path: pulmonary artery, arterioles, compliant capillary bed, venioles, pulmonary veins, back to the left pump. The systemic and pulmonary circuits cross, making the system a single circuit with two pumps in series — exactly like the human cardiovascular system.


Non-Sucking vs. Sucking Pumps

Sucking Pump (Roller Pump)

A standard roller pump used in cardiopulmonary bypass compresses tubing to push fluid forward; the tubing recoils behind the roller, generating suction that refills the tubing. Because the tubing is always full due to suction, pump output is determined by the speed of the pump: output = stroke rate × stroke volume. External factors, such as increased hydrostatic pressure from lifting the fluid container, do not alter the output. The output of a sucking pump is controlled by pump factors.

Non-Sucking Pump

The heart behaves as a non-sucking pump. Its ventricle is normally flat on cross-section; after compression, it does not rebound and suck — it fills passively after being emptied. If the pump runs at 80 beats per minute with no pressure in the system, there is no flow. Even increasing rate and contraction strength produces no output. Flow only occurs when the fluid source (bottle) is raised above pump level, meaning pressure in the system must be sufficient to drive fluid into the ventricle.

Therefore, flow in a non-sucking pump is controlled by systemic factors — specifically, the amount of pressure in the system. Increasing pressure increases flow; decreasing pressure decreases flow.

Key distinction: Sucking pump output = pump factors (rate, stroke volume). Non-sucking pump output = systemic factors (pressure in the system).


Mean Vascular Pressure

In the model, the compliant beds may be flaccid because of low fluid volume — the system is in hypovolemic shock. Just as in humans with inadequate cardiovascular pressure from low blood volume, increasing heart rate or contraction strength does not improve cardiac output. Adding fluid volume (e.g., 250 CC transfusions) gradually increases flow. However, the increase is non-linear: the first 250 CC may produce little change, while subsequent additions cause disproportionately large increases in flow.

The pressure in any hydraulic system is the product of volume and system compliance. The pressure that forces fluid into the non-sucking heart, resulting from blood volume and vascular compliance, is called mean vascular pressure (MVP).

Mean vascular pressure is the pressure in the vascular system with the heart stopped, after pressures have equilibrated between arteries, capillaries, and veins.

  • Normal range: 16–18 mmHg above mid-heart level

  • High output states: 20–30 mmHg

  • Shock states: 6–8 mmHg

Compliance

Compliance of the vascular beds can be decreased by contracting the muscles around the beds (decreasing distensibility). In the model, pressing on the beds increases pressure and flow. A clinical corollary: vasopressors increase cardiac output by decreasing vascular compliance; spinal anesthesia and vasorelaxers decrease cardiac output by increasing vascular compliance.


Inlet Impedance

Even with a positive mean vascular pressure, other factors can reduce flow. The most obvious is resistance. In the model, adding a clamp (resistance) to the outlet of the pump (aortic side) causes a large rise in pressure (e.g., 220/100 mmHg), but flow remains unchanged — the pump is strong enough to force fluid past the resistance. This mirrors clinical situations like aortic stenosis, arteriolar hypertension, and coarctation of the aorta: cardiac output remains normal as long as the heart is strong enough to eject its contents.

However, adding a similar resistance to the inlet of the pump causes a dramatic decrease in output. Why the difference? Inlet resistance has a large compliant bed upstream that stores potential energy from pump ejection, leaving less kinetic energy to force fluid past the resistance. Outlet resistance, by contrast, has very little distensible bed upstream, so most energy remains kinetic.

Inlet impedance is the combination of a resistance point and the vascular distensibility upstream from that resistance point that together impede flow to the pump inlet and decrease pump output.

The Role of the Atrium

The most significant factor in minimizing inlet impedance is the atrium. Its function: when the inlet valve closes, the empty, distensible atrium allows uninterrupted venous flow during ventricular systole; during diastole, venous and atrial flow move into the ventricle unimpeded. Although atrial displacement constitutes only 15% of the volume ejected per beat, the atrial effect makes possible four times the flow that would occur without a mechanism to prevent the inertia of starting and stopping flow to an intermittent pump.

Clinical corollaries of increased inlet impedance (reducing cardiac output):

  • Mitral stenosis

  • Venous obstruction

  • Atrial fibrillation

  • Nodal rhythm

  • Cardiac tamponade

  • Ventricular non-compliance

  • Extremely rapid heart rate

Clinical corollaries of reduced inlet impedance (increasing cardiac output):

  • Arteriovenous fistula (bypasses compliant bed)

  • Exercise (muscle-vein pumps force fluid past inlet resistance points)


Pump Energy Excess vs. Pump Energy Failure

So far, neither an increase in rate nor strength of contraction increased flow when the pump was in a state with adequate pressure. This is because the pump was operating in pump energy excess.

Pump Energy Excess

Pump energy excess is the state where the pump expends more energy than needed to eject fluid from the ventricles.

In this state (which corresponds to normal, day-to-day heart function), the determinants of cardiac output are:

  1. Mean vascular pressure (components: fluid volume and system compliance)

  2. Inlet impedance (combination of resistance and upstream distensible bed)

Rate and contraction strength do not increase output. Clinical evidence: propranolol (which reduces heart rate and contraction strength in therapeutic doses) causes no decrease in output unless the ventricles are in energy failure.

Pump Energy Failure

Pump energy failure (not to be confused with congestive heart failure) is the state where the pump does not expend sufficient energy to prevent the ventricles from filling completely before the end of diastole.

In energy failure, the determinants of cardiac output are:

  1. Rate – If the heart rate is very low (e.g., complete heart block at 20–30 bpm), increasing rate increases output until the heart reaches energy excess (typically around 70 bpm). In the model, increasing rate from zero (stopped pump) to 1 beat/min ejects 100 CC and yields 100 CC/min flow; at 2 beats/min, 200 CC/min; and so on, until the ventricles no longer have time to fill completely at the given mean vascular pressure and inlet impedance.

  2. Strength of contraction – If contraction is insufficient to overcome an outlet impedance (e.g., manually contracting the ventricle weakly), outflow impedance limits ventricular emptying. The ventricles fill completely before end-diastole, causing intermittent inflow and reduced output.

Clinical corollaries of pump energy failure:

  • Myocarditis

  • Myocardial infarction

  • Aortic outflow obstruction with weak ventricular contractions


Special Notes on Starling's Law and Poiseuille's Law

With the insight from the model:

  • Starling's Law – which states that greater filling at diastole leads to greater strength of contraction at systole – expresses a mechanism of cardiac output control only during myocardial energy failure. At all other times, it has only energy conservation implications.

  • Poiseuille's Law – which expresses outlet resistance as a determinant of cardiac output – is similarly only valid during myocardial energy failure. At all other times, it merely expresses a pressure gradient across an outlet resistance point.


Conclusion: A Hydraulic Model of Cardiac Output

All available data from human physiologic experience correlates with the findings from the model. The human heart is a non-sucking, intermittent outflow, continuous inflow pump. Cardiac output has two separate sets of determinants, only one of which can be operative at a time — the set that potentially limits output most becomes the determinant.

Condition

Determinants of Cardiac Output

Pump energy excess (normal heart)

Mean vascular pressure (volume + compliance) + Inlet impedance (resistance × upstream distensibility)

Pump energy failure (weak or slow heart)

Low rate + Insufficient contraction strength to overcome outlet impedance

Most phenomena seen in the cardiovascular system require no other explanation than simple hydraulic mechanics.