Determinants of Cardiac Output
- 19Unfamiliar
- 0Learning
- 0Familiar
- 0Mastered
What is the primary difference between a sucking pump and a non-sucking pump?
What is the primary difference between a sucking pump and a non-sucking pump?
19 questions
- 1
What is the primary difference between a sucking pump and a non-sucking pump?
- A
A sucking pump cannot generate suction, while a non-sucking pump can.
- B
A sucking pump output is determined by systemic factors, while a non-sucking pump output is determined by pump speed.
- C
A sucking pump has a ventricle that is flat in cross-section, while a non-sucking pump has a round ventricle.
- D
A sucking pump fills by suction generated behind the roller, while a non-sucking pump fills passively.
Correct answer
DA sucking pump fills by suction generated behind the roller, while a non-sucking pump fills passively.
Explanation
The roller pump sucks fluid into the tubing by recoil, whereas the non-sucking pump has a ventricle that does not rebound and fills passively. This distinction determines how output is controlled.
- A
- 2
In the non-sucking pump model, what is required for flow to occur?
- A
Increasing the pump rate above 80 beats per minute.
- B
Adding a resistance at the outlet of the pump.
- C
Raising the fluid container above pump level to create positive pressure.
- D
Increasing the strength of contraction by hand-cranking.
Correct answer
CRaising the fluid container above pump level to create positive pressure.
Explanation
The non-sucking pump cannot suck fluid; therefore, flow only occurs when the pressure in the system is above pump level, achieved by raising the fluid container.
- A
- 3
What determines the output of a sucking pump (roller pump)?
- A
The pressure in the fluid container above the pump.
- B
The compliance of the tubing downstream.
- C
The speed of the pump and the volume between rollers.
- D
The amount of resistance at the inlet.
Correct answer
CThe speed of the pump and the volume between rollers.
Explanation
For a sucking pump, output equals stroke rate times stroke volume, where stroke volume is the volume of fluid between the rollers. External pressure does not alter output.
- A
- 4
In the model, what condition is simulated when the compliant beds are flaccid and pressure is below pump level?
- A
Obstructive shock.
- B
Septic shock.
- C
Hypovolemic shock.
- D
Cardiogenic shock.
Correct answer
CHypovolemic shock.
Explanation
Low fluid volume leads to low pressure in the system, causing hypovolemic shock. In this state, increasing heart rate or contraction strength does not improve output.
- A
- 5
What two components determine mean vascular pressure?
- A
Inlet impedance and outlet resistance.
- B
Systemic vascular resistance and cardiac output.
- C
Heart rate and stroke volume.
- D
Blood volume and vascular compliance.
Correct answer
DBlood volume and vascular compliance.
Explanation
Mean vascular pressure is the product of blood volume and system compliance. It is the pressure in the vascular system when the heart is stopped and pressures have equilibrated.
- A
- 6
What is the normal range of mean vascular pressure (in mmHg above mid-heart level)?
- A
10 to 12 mmHg.
- B
16 to 18 mmHg.
- C
20 to 30 mmHg.
- D
6 to 8 mmHg.
Correct answer
B16 to 18 mmHg.
Explanation
Mean vascular pressure is normally 16–18 mmHg above mid-heart level, but can be lower in shock (6–8 mmHg) and higher in high output states (20–30 mmHg).
- A
- 7
According to the model, what effect does decreasing vascular compliance (e.g., by pressing on the compliant beds) have on flow?
- A
Flow decreases because the atrium cannot fill properly.
- B
Flow decreases because resistance increases.
- C
Flow remains unchanged because the pump is non-sucking.
- D
Flow increases because pressure increases.
Correct answer
DFlow increases because pressure increases.
Explanation
Decreasing compliance increases pressure in the system, which increases flow into the non-sucking pump, thereby increasing output. This is analogous to vasopressors increasing cardiac output.
- A
- 8
In the model, adding resistance to the outlet of a strongly working pump has what effect on flow?
- A
Flow increases because resistance creates backpressure.
- B
Flow becomes pulsatile instead of continuous.
- C
Flow decreases significantly due to increased afterload.
- D
Flow remains unchanged because the pump overcomes the resistance.
Correct answer
DFlow remains unchanged because the pump overcomes the resistance.
Explanation
With a strong pump, outlet resistance does not reduce flow; the pump simply generates higher pressure to overcome it. Clinically, conditions like aortic stenosis do not reduce cardiac output if the heart is strong enough.
- A
- 9
Why does adding resistance to the inlet of the non-sucking pump decrease output, while outlet resistance does not?
- A
Inlet resistance is upstream of a large compliant bed that stores potential energy, reducing kinetic energy available to push fluid past the resistance.
- B
The pump cannot generate suction to overcome inlet resistance.
- C
Outlet resistance increases the strength of contraction.
- D
Inlet resistance reduces the pressure gradient across the pump.
Correct answer
AInlet resistance is upstream of a large compliant bed that stores potential energy, reducing kinetic energy available to push fluid past the resistance.
Explanation
The compliant bed upstream of the inlet resistance stores potential energy from ejection, leaving less kinetic energy to force fluid past the resistance. Outlet resistance has little compliant bed upstream, so kinetic energy remains high.
- A
- 10
What term describes the combination of a resistance point and the distensible bed upstream that impedes flow to the pump inlet?
- A
Systemic vascular resistance.
- B
Inlet impedance.
- C
Afterload.
- D
Mean vascular pressure.
Correct answer
BInlet impedance.
Explanation
Inlet impedance is the product of a resistance point and the upstream distensible bed. It reduces pump output by hindering inflow.
- A
- 11
What is the role of the atrium in minimizing inlet impedance?
- A
It actively sucks blood into the ventricle during diastole.
- B
It prevents backflow of blood into the veins.
- C
It provides 15% of the ejected volume but increases flow fourfold by allowing continuous venous inflow.
- D
It increases the compliance of the ventricle.
Correct answer
CIt provides 15% of the ejected volume but increases flow fourfold by allowing continuous venous inflow.
Explanation
The atrium, by being empty and distensible, allows uninterrupted venous flow during ventricular systole and unimpeded flow during diastole, preventing the inertia of starting and stopping flow. This increases flow four times.
- A
- 12
Which of the following clinical conditions is a corollary of increased inlet impedance?
- A
Arteriovenous fistula.
- B
Mitral stenosis.
- C
Exercise.
- D
Aortic stenosis.
Correct answer
BMitral stenosis.
Explanation
Mitral stenosis increases resistance at the inlet to the left ventricle, increasing inlet impedance and reducing cardiac output. Other examples include venous obstruction, atrial fibrillation, and cardiac tamponade.
- A
- 13
In the model, during pump energy excess, what are the two determinants of cardiac output?
- A
Blood volume and heart rate.
- B
Mean vascular pressure and inlet impedance.
- C
Strength of contraction and outlet resistance.
- D
Heart rate and stroke volume.
Correct answer
BMean vascular pressure and inlet impedance.
Explanation
When the pump has excess energy (expending more than needed to eject), output is determined by mean vascular pressure (volume and compliance) and inlet impedance.
- A
- 14
What defines the state of pump energy failure?
- A
The pump does not expend sufficient energy to prevent the ventricles from filling completely before the end of diastole.
- B
The pump is unable to maintain mean vascular pressure.
- C
The pump has a low heart rate below 60 beats per minute.
- D
The pump cannot overcome outlet resistance due to high systemic vascular resistance.
Correct answer
AThe pump does not expend sufficient energy to prevent the ventricles from filling completely before the end of diastole.
Explanation
In pump energy failure, the pump's energy is insufficient to prevent the ventricles from filling completely by end-diastole, limiting inflow and output. This is distinct from congestive heart failure.
- A
- 15
During myocardial energy failure, which two factors determine cardiac output?
- A
Blood volume and vascular compliance.
- B
Mean vascular pressure and inlet impedance.
- C
Heart rate and strength of contraction to overcome outlet impedance.
- D
Atrial function and ventricular compliance.
Correct answer
CHeart rate and strength of contraction to overcome outlet impedance.
Explanation
In energy failure, low rate and/or insufficient contraction to overcome outflow impedance limit output. Increasing rate increases output until the heart returns to energy excess, after which further rate increases have no effect.
- A
- 16
According to the model, under what condition is Starling's Law (greater filling leads to greater contraction) a mechanism of cardiac output control?
- A
During pump energy excess.
- B
When mean vascular pressure is normal.
- C
During pump energy failure.
- D
When inlet impedance is low.
Correct answer
CDuring pump energy failure.
Explanation
Starling's Law is only operative during myocardial energy failure because filling is incomplete and increased filling can increase contraction. In energy excess, it merely conserves energy.
- A
- 17
According to the model, when does Poiseuille's Law (outlet resistance determining flow) apply to cardiac output?
- A
During pump energy failure.
- B
During pump energy excess.
- C
When mean vascular pressure is low.
- D
When inlet impedance is high.
Correct answer
ADuring pump energy failure.
Explanation
Poiseuille's Law is only valid during myocardial energy failure because then the pump cannot overcome outlet resistance, so resistance becomes a limiting factor. In energy excess, outlet resistance only creates a pressure gradient.
- A
- 18
Which of the following best describes the human heart based on the model?
- A
A sucking pump that determines output by its rate and stroke volume.
- B
A pump that fills by suction during diastole.
- C
A non-sucking, intermittent outflow, continuous inflow pump.
- D
A pump whose output is solely determined by mean vascular pressure.
Correct answer
CA non-sucking, intermittent outflow, continuous inflow pump.
Explanation
The model demonstrates that the human heart behaves as a non-sucking pump: it does not suck to fill, output is intermittent, but inflow from the veins is continuous (aided by the atria).
- A
- 19
Which set of cardiac output determinants is operative at any given time?
- A
The set that maximizes output.
- B
The set that potentially limits output the most.
- C
The set that involves mean vascular pressure and inlet impedance.
- D
The set that includes heart rate and contractility.
Correct answer
BThe set that potentially limits output the most.
Explanation
Cardiac output is determined by the set of factors that are most limiting at that moment. The two sets (energy excess and energy failure) are mutually exclusive and the one that restricts output more is operative.