I did send out an email yesterday But the smart evaluations just went live So I think this year especially it's important for us to get feedback from you because sort of we've gone through this big change obviously in the middle of the course and I think like everyone else. We're hoping that this is not something that drags on into the fall But in case it does having you know, lots of good feedback from students about how they found this experience Will be helpful for us if we have to do this in the fall again, right? So we sort of made this change on the fly and I think, you know, I hope you feel the same way I think I think we've done a reasonably good job But any kind of feedback from you about things that you liked or things that you didn't like would would really be

beneficial for us moving forward So I appreciate that more than 10% of the students in the class have already filled out this smart evaluations But if you do have the chance to do it, we would really appreciate it Particularly, maybe the written comments About sort of this transition. There's also on the mycourses web page. There is a Discussion board I set it up to be anonymous so you don't have to put your name to anything but We're we're trying to collect feedback there too. If you want more immediate feedback For us because we won't see any of these things on the smart evaluations until the class is over so Again, thank you for taking time to do that. I really do appreciate it So like in the other Thursday lectures what we'll be doing today is going over some problems So we've been talking about heat exchangers. So we'll do some heat exchanger problems today. We

Did one problem, or two last Tuesday, so we're gonna try to do three today and the first I don't think is on the handout for the Heat exchanger problems, but I did want it to shoot I wanted to show you a case where we're going to use the log mean temperature difference method So in this particular question it to think about a cooling process where we have some fluid where we're given the specific heat and we're cooling that from 80 degrees to 50 degrees Celsius and it tells Us the mass flow rate. It's in a counter flow or will see parallel flow heat exchanger And we're trying to decide which configuration would be better for our application

The cooling fluid we're told comes in at 15 degrees Celsius and we're told the mass flow rate of the cooling fluid So then the problem asks is what is the required transfer surface area. So how much heat transfer area? Do we need for the heat exchanger in both different configurations? so we'll compare sort of a parallel flow in a counter flow heat exchanger and then we're told that the convection coefficient of the process fluid side is 3500 watts per meter squared Kelvin and 4500 watts per meter squared Kelvin Respectively, so if we draw out the problem here in my sketch. I'm only showing the parallel flow, but For the counter flow case. It's just the flow in the tube. We'll be moving in the other direction So we're given some information about the hot fluid at the inlet and the outlet and We're told the inlet temperature and the mass flow rate of the cold fluid But we don't know the outlet temperature of the cold fluid

We're told the heat transfer coefficient on both sides of our tube So inside the tube in outside of the tube And we're asked to find the area for heat transfer required in parallel flow and in counter flow So if we think about the area that's going to be the perimeter of our cylinder multiplied by the length so as the area goes up assuming the diameter of the tube stays the same Then what we end up doing is making a longer and longer heat exchanger So you could see that could be a limitation if you want to fit your heat exchanger in a particular, you know piece of packaging So the assumptions that we'll make for this problem first, we'll assume that the system is at steady state We're going to do that for all of these heat exchanger problems We're going to assume that the fluid and material properties are constant. We assume that basically for every question that we do in this class

We'll assume that there's no losses to the surroundings. Right so our heat exchange is Adiabatic so that all of the heat that comes out of the hot side goes into the cold side and none of it is lost to the atmosphere We're going to assume that there's no axial conduction along the tube, even though there may be a temperature difference So basically we're assuming that this heat transfer is small and we're going to assume that the wall of the tube is thin and That there's no fouling on either the inside or the outside of the tube so we talked about this in the lecture, but we'll need to find sort of the effective heat transfer coefficient or the net resistance between the hot fluid and the cold fluid so when we do this we're going to assume that there is no conduction resistance in the tube and That there's no sort of gunk on the inside or outside of the tube which would add resistance to the problem

So I talked about this in the problem that we did on Tuesday as well But for these heat exchanger problems I always like to have kind of a nice methodology that I can use for any type of problem, right? so in this case We've got these heat exchangers and I'm gonna use this 2 by 2 matrix for every heat exchanger problem that I do So first, I want to see what's the objective So am I trying to find how big my heat exchanger is supposed to be or am I trying to find how much heat is? Being transferred and in this case, we're asked what the heat exchange area is right So if we're asking for that area, that means we're looking at the sizing So next I have to choose the method. So there's a log mean temperature difference in the effectiveness NTU method So there's two different options here So for log mean temperature difference We need to know all of the temperatures that all the inlets and the outlets and it's really best if we use it for

parallel and counter flow heat exchangers Personally, I think anytime you get to a more complicated geometry than that effectiveness. NTU is a good way to go But in this case, I actually added this problem just to show you the log mean temperature difference So we're gonna pick the log mean temperature difference. So we're trying to do sizing for using the log mean temperature difference method It's sort of the nice thing about the log mean temperature difference though. Is that We're gonna use the same equation rather whether or not we're sizing or trying to find the heat. It's not really a different process So here we might remember from Thermodynamics or from our lecture on Tuesday that all of the heat that comes out of the hot side of our our heat exchanger Goes into the cold side So if we assume that there's no phase change in the fluid Then we can say that the heat on either side is going to be m dot times the specific heat times the change in temperature

So we know that the magnitude of these things is going to be the same on both sides So I've made both of these terms positive by taking the hotter temperature minus the colder temperature in both of these brackets In heat transfer we talked about this fluid heat Capacity rate or capital C and that capital C is going to be M times CP so we can write the same equation like this We also know we're going to use the log mean temperature difference method so I'm gonna start with a parallel configuration So here I have equations for the heat transfer which looks like Newton's law of cooling but instead of multiplying by delta T we multiply by the log mean temperature difference and now I have an equation for the log mean temperature difference where I have delta T 1 minus delta T 2 divided by the natural log of delta T 1 divided by delta T 2

So here we... the difference between the parallel and the counter flow Geometries is going to be how we define delta T 1 and delta T 2. In both cases delta,T 1 involves the hot Inlet fluid and Then delta T 1 is going to be the hot Inlet fluid minus the cold fluid that touches the hot Inlet So in this case because it's a parallel flow The hot Inlet is in communication with the cold Inlet. So then down here. We have the hot Inlet minus the cold inlet Delta, T 2 always touches the hot outlet and in this case the hot out is in communication with the cold outlet So we have T hot out - T cold out down there In the counter flow heat exchanger, we really use the same equations except our delta T

definitions change Delta, T 1 is still the hot Inlet But if we look in our counter flow example, our hot Inlet is in communication with the cold outlet so we have t hot in - t cold out and Our hot outlet over here is in communication with our cold Inlet. So we have t hot out - t cold in So these are the equations we're going to use and we'll use this equation for Q to find the area so I need to find the heat transfer some way and then I can isolate the top equation here for area and calculate how big my heat exchanger supposed to be

So first we'll start finding the heat so in this case We know that all the heat coming out of the hot side is the same as all the heat going into the cold side So the nice thing is I know everything on the hot side So here I know the inlet temperature the mass flow rate, and I know the outlet temperature and from conservation of mass I know that the mass flow rate must be the same. I'm also told the specific heat of the hot fluid so I can put all that information into my calculator and I can find the magnitude of the heat that's transferred from the hot fluid to the cold fluid So here the hot fluid is losing two hundred and ten thousand watts or two hundred and ten kilowatts Which means that the cold side must be accepting all of that heat So now I can look at the cold side to try to figure out the cold side outlet temperature

So I'm going to use now my same equation for heat but now I'm saying that the hot side heat is equal to the cold side heat if I look at the magnitudes and I can isolate this equation for the cold outlet temperature So here I know the cold Inlet temperature. I know the heat transfer. I know the mass flow rate on the cold side But I don't yet know the specific heat on the cold side. So that wasn't given to me in the problem So now I'm gonna have to look something up on a table. So I'm gonna have to find some material properties So in this case, I look at table eight point six Which tells me about properties for saturated water

This is just like, we saw this last week to where I don't actually know what my average temperature here is so I'm just gonna guess and I'm gonna guess here that my average temperature is 300 Kelvin Which is the same as assuming that the outlet temperatures 39 degrees Celsius So I pick 300 because it's a line on my table. I mean you could really pick anything here We'll check it at the end. So Here if my outlet temperature is 39 degrees Celsius then I have a specific heat value

You can see here too. If you look in this column the specific heat of the liquid is not a very strong function of temperature So it's probably not going to matter too much what our temperature assumption here is It's also important to remember that because here we're talking about the liquid. We have to pick from the table CP,F So the F tells us that it's the saturated liquid whereas G would tell us it's the saturated vapor So now we know our specific heat or at least we have an assumption for our specific heat I can put that into my equation for my outlet temperature on the cold side. I Put some numbers into my calculator and I find that the outlet temperature is 35 degrees Celsius

Now I assumed that the outlet temperature was 39 degrees Celsius So really my assumptions not perfect so here I'm high 4 [degrees] So I it would actually be I think 298 degrees Celsius But I'm not going to interpolate and we saw that that specific heat was a very weak function of temperature if you're on an exam, even if you pick a What you feel like is a specific heat that's off Just kind of make a note and say that If I had time I would go through and iterate this and find a better value for a specific heat But I'm gonna just carry on as if this is correct

So now that we know all of our temperatures we can start to go and use this equation so Now we know our delta T 1 this is for the parallel flow heat exchanger So I know my hot outlet and my cold Inlet. So the difference there is 65 degrees I know my delta T 2 is 15 degrees So I can take those two numbers and put them in and find my log mean temperature difference Which is 34 point one degrees So that's good now, I know almost everything in my equation for Q, so Here, I just sort of carried over the fact that I know my log mean temperature difference I have this equation for Q but Q's not what I want. What I actually want is the area so I isolate this equation for the area and I know Q. I know the log mean temperature difference, but I don't yet know the effective heat transfer coefficient

So here we come back to the fact that we're going to assume that we have a thin wall for our heat exchanger So that the resistance from that wall is not important. So If that's true, and there's no fouling on the tube, then I can get my effective heat transfer coefficient using this equation so in this problem They told us the heat transfer coefficient on the inside of the tube and the heat transfer coefficient on the outside of the tube So I don't have to do any kind of internal convection analysis. I Put this in and I can find my effective heat transfer coefficient Once I know my effective heat transfer coefficient now I know everything in this equation so I can put some things into my calculator check my units and I find that the area is three point one three meters squared

And that's good because that's what the problem asked me to find. So now I know how to find the area so I did this for the parallel flow heat exchanger and Now we're basically going to do the same process for the counter flow heat exchanger So the good thing is We're not going to so when we got these the outlet temperature For the cold side. We were just using the first law. So the first law doesn't care about how big our heat exchanger is It's just telling us if I lost this much heat from the hot side Then I must have gained all that heat on the cold side provided my heat exchanger is insulated So my temperatures are not going to change But my Delta T's are gonna change because the equations are different. So in the counter flow heat exchanger the hot Inlet touches the cold outlet and The hot outlet touches the cold Inlet. So these temperature differences are different

So here my delta T one is forty-five degrees Celsius and my delta T two is 35 degrees Celsius so these two numbers are closer together and Then my log mean temperature difference is thirty nine point eight degrees Celsius, which is higher So I think it was I want to say it was like 35 or something. I think in the parallel flow case so here what happens when you set it up in counter flow is Like we see in this picture here the temperature difference along the length of the heat exchanger stays more constant Right. So, let's see how that affects the area So here we're going to use the same equation that we did in the parallel flow It's just our log mean temperature difference is different. We still have the same heat transfer coefficients on the inside and outside of the tube We have our new log mean temperature difference We put that information into our equation and here we see that our counter flow area is two point six eight meters squared

So just by changing the plumbing on our device, so by taking the tubes and connecting them to different ports We've reduced the area or the size of our heat exchanger by fourteen percent So this is a pretty powerful thing If you're sort of in an industrial setting and you're using this kind of a heat exchanger setting it up in counter flow Usually we'll give you sort of a more efficient result. So you you're selling a smaller device here, right? Which means that you can reduce the price and sell it to more customers or you can keep the price the same Increase your profit margin This message is from Evelyn and she really loves baby shark so she colored this for us so Does anyone have questions either in the chat or Audibly if you want to unmute your mic, does anybody have questions about how we did this example?

Okay, we will move on to the next problem Let's do this one next I think this is the next one on the sheet So in this problem were given a shell and tube heat exchanger now, this is not just a parallel flow or a counter flow heat exchanger It's one where the shell comes in or the tube comes in Right and it snakes back and forth along through the shell so the tube is making several passes Inside the shell and they tell us that there's multiple tubes inside this shell So there's this one big bath of fluid on the outside and a lot of little tubes that are running back and forth

To try to transfer as much heat as we can So we're told some information about the cold Inlet we know the temperature is 15 degrees Celsius and we know the mass flow rate is two and a half kilograms per second and We're told the outlet temperature on the cold side So it's always nice when we know at least one side if we know everything on one side Then we know we can find the heat transfer So here on the hot side we're told the inlet temperature but we don't know the mass flow rate and Then on the outlet on the hot side, we're told the temperature, but we don't know the mass flow rate so here maybe you're looking at this and you're already thinking I can use the first law analysis here on the whole heat exchanger and I can see that all the heat that gets accepted on the cold side Must have come from the hot side so I could do that to find the mass flow rate of the hot oil

We're told our heat transfer coefficient on the hot side We know that we have ten tubes and each tube makes eight passes So a pass is once down the shell so to get back to where we started from is two passes Right, and we're told the diameter of the tube What we're asked to find here is the length Now I took this to mean and it's not really explicit. So this would be we'd want to be more explicit on an exam problem But I took this to mean the length of each pass So you could find different lengths you could find the total length of all the tubes put together But I guess no matter which L you're finding you would still have shown that you knew how to do the heat transfer part if we get To there, but the L that I'm taking is the L that I'm showing on my diagram here. So the length of one path So assumptions, we're gonna assume that the problem is at steady state

That the fluid and material properties are constant that there's no losses to the surroundings and That the tube is thin walled with no fouling. I guess we're also assuming here that the heat transfer in here if I just go back I Don't think I wrote this on my assumptions list but we're also assuming that the heat transfer here on the ends where the tube is turning around that that's Negligible compared to the rest of the heat transfer. So we're only talking about the length of the pass We're not talking about how much height there is as it's turning around there So we're also going to assume that the flow is fully developed in the tube I think it tells us that in the problem, but we're gonna check that numerically anyway

So again for all of these heat transfer problems when when we're dealing with heat exchangers I want to come back to this two-by-two matrix right at the beginning so that when I first look at the exam and I say Like what am I supposed to do then? Hopefully if I go back to this sort of two-by-two matrix then I can sort of help myself start the problem and I think once we build up that inertia things become a little easier, so Here they're asking us for the length of the tubes Which tells us something about the size, right? So ultimately the length will tell us what the heat transfer area is and Because we have a fairly complicated geometry. We're gonna deal with the effectiveness NTU method

So we're gonna try to use this process here. So I have kind of a flowchart for how to do these problems First I want to pick the geometry then I want to find my big C values Then I'll find effectiveness using the definition and I'll use the value for effectiveness to find NTU for using one of the correlations in the textbook and then I'll use NTU to find A because the definition of NTU has an A in it So first we want to pick the geometry So here we can see from this picture that we have a shell and tube heat exchanger. So there's tubes running through this shell

We have one shell pass. So what that means is that There's no baffles in the problem If we have baffles, then we would have like lines running vertically here So that that flow here would have to kind of go up and down across the tubes multiple times So that would be shell passes. But here we don't have any of those because there's no baffles inside of our problem We have an even number of tube passes at eight So now I'm gonna look at table 11.4 because I want to get an expression for NTU as a function of effectiveness So here I look and I see that there's some shell and tube heat exchanger correlations Right. So now we have one shell pass and an even number of tube passes. So here we can use this equation Now it's actually a set of equations because I think they wanted to make the equation look a little bit cleaner

so we have this value of capital e but everything here is a function of effectiveness and see our big CR so the ratio of my big C's So here I have an equation for NTU as a function of CR and effectiveness because E is a function of it So now I would like to try to use that equation, so I need to find my C min and C max values So here We need to know the CP of water and oil and we need to know that Mass flow rate on the hot side because we don't have any of that information yet So if I look at these equations if I did an accounting here? It's nice that I know the mass flow rate on the cold side, but that's the only thing that I know

So we look for Water specific. I guess we're going to look at engine oil. So we need a average temperature So we're gonna say that that the oil temperature is 130 degrees so that our average temperature is 403 Kelvin So now I'm gonna assume that's about 400 degrees Kelvin So I mean again we can pick off pretty much anything from this list and CP is again Sort of a weak function of temperature here So we get a value for CP from the table Again, you got to watch the units when you're doing this because it gives us CP on the table in kilojoules per kilogram Kelvin But I'm gonna change that right into joules because I want to change this into watts. Later But if you kept it as kilojoules that would be fine you just really gotta track your units when you're doing your equations So now I know CP of oil. I don't know the m dot of the oil yet

So I can go to the water side and try to find My temperatures right? So here I know my average water temperature is 50 degrees Celsius, which is 323 degrees Kelvin I'm gonna say that's about 325 degrees Kelvin and I'll pick that information off the table so so far. It looks like I only need specific heat but I Noticed in the question. They never told me what the heat transfer coefficient in the tubes was So I'm gonna have to do some internal convection analysis here So from the table, and I think I might have chopped the table off a little bit here But I pulled off all of the values that I would use to do an internal convection analysis So I the specific heat the density the viscosity

the fluid conductivity and the Prandtl number So that we would have to remember from last week But again again, if you didn't do this now as you went through the problem You would sort of come to a point where say oh, I need to know H. I gotta go back to that table. So If I do this now I know enough information to find my Big C on the cold side and That's just over 10,000 watts per degree Kelvin So now I need find the mass flow-rate on the hot side and like we said when we introduced the problem I Can get this from doing a first law analysis on my whole heat exchanger So, I don't know the heat transfer but I can find the heat transfer if I look on the cold side because I know everything about the cold side now, so

here I can find my Actual heat by looking at values on the cold side and I can see that this is just about a hundred and ninety thousand watts I know that all the heat that gets accepted on my cold side has to have been lost by my hot side So now if I take the same value of heat I can find stuff on the hot side because the only thing here I don't know is my mass flow rate on my hot side when I do a problem like this, I like to set my problem up as

So here I'm trying to find the hot mass flow rate. So I multiply this by the cold mass flow rate multiplied by the ratio of specific heats multiplied by a ratio of temperature differences I Like to do this because then I worry less about the unit's so if my CPS are both in the same unit Then it's fine and the unit's will drop out and if my Delta T is in the same unit again, the unit's are fine And they drop out so when I do this, I see that the mass flow rate on the hot side is 5.2 kilograms per second So now I know the mass flow rate of the hot oil which is one of the things I think the problem asked me to find So now I can go back over here from when I looked up the specific heat on the hot side. I can calculate my big C on my hot side, which is 12,152 watts per degree Kelvin So now I know my C hot in my C cold

So C hot is 12,000 Watts per Kelvin about and C cold is about 10,000 watts per Kelvin so I know that my C max, big C max is on the hot side and Big C min is on the cold side So I can find my ratio of big C's I always want this to be less 1 than so C min is on the top and it's 0.86 So this is nice because now it took us a while But we found all our values of Big C and now we can find our effectiveness So I'm going to find effectiveness here from the definition So in this effectiveness NTU method depending on which flow chart you're using you might have to find effectiveness first And you might have to find NTU first Whichever one comes first on the flow chart you find that from the definition So here we're going to use effectiveness to find NTU, but we need to know the effectiveness first

So our effectiveness is Q actual divided by Q max. I Know that definition for Q Max is going to be Big C min times the biggest temperature difference I can find in my heat exchanger, which is going to be T hot in - T cold in I have a numerical value for the heat transfer but I kind of want to show you how to set this up so I could Define the effective as the actual heat transfer by the heat transfer on the cold side or the heat transfer on the hot side the reason I like to do this is again, cuz units are gonna drop out so Here because my Big C on the cold side is my C min Then C min is equal to C cold so I can just cancel those out and My effectiveness is gonna be a ratio of these temperature differences and because my temperature differences are in the same unit Then it just it all drops away So I get my effectiveness is .483

You could have done this by just putting Q actual on the top and putting more information into your calculator But like I said, I'm good at screwing things up on my calculator. So this way I think it's a little bit safer So now I have my effectiveness Which is good because I need my effectiveness to find my NTU value so we already found the equation that we want to use for NTU and it's a bit of a bear because Here we have a bit of an ugly equation so first we're gonna have to find capital e which is a function of effectiveness and Cr and then we'll put that into NTU which is a function of CR and capital E So there's two things. I'm gonna find here. I've separated them on the page first. I'll find capital E So I know all of this information I put it in my calculator and I find that capital E is 1.73

I put that into my equation for NTU and I find that the answer is 1 So now I know how many NTU that I have right and now I'm gonna try to use my Definition of NTU to find the amount of area that I need in my heat exchanger to get the performance that I want so I remember that the definition of NTU is Equal to the effective heat transfer coefficient multiplied by the heat transfer area divided by C min Ultimately what I want to find here is the length of a tube pass, but that's going to be a function of the area So here I'm gonna take NTU and isolate for area I know C min, and I know NTU but I don't know the effective heat transfer coefficient yet So here I want to use the same equation I used in the last problem where my effective heat transfer coefficient is

What's shown here? I guess I just don't like to say it out loud because it's a bit of a mouthful, right? But I want the reciprocal of the sum of the reciprocals, I guess So I know the heat transfer coefficient on the hot side, but not the cold side So here my cold side fluid is running through the tubes So I have to do an internal convection analysis through the tubes now The problem tells me to assume that it's fully developed because these tubes are probably gonna be pretty long So that's probably reasonable to assume that it's fully developed the whole way, but we'll check that out, too So based on the number the information that I pulled off the table. I'll use this definition for Reynolds number. I Know the mass flow rate on the cold side. I know the diameter of the tubes and I know the viscosity

So I can put that in and I see that it's turbulent flow, so that it becomes fully developed after 10 diameters so again, we're gonna assume that this pipe which is sneaking back and forth along our shell is Longer than 10 diameters. So on we're gonna assume that it's much longer than that So it's fully developed probably for the whole width or pretty close. So If that's true Then I can use this nusselt number correlation And if you're forgetting how to do this, we can always go back to the information from last week So the videos from problems last week and we would have done a problem like this much more in depth But here I can pull a turbulent flow correlation I'm gonna find my Reynolds number and I know my Prandtl number because I looked that up off the The table and I can see that my nusselt number is just about 120. I

Remember that the definition of nusselt number is the heat transfer coefficient Multiplied by the diameter of the tube divided by the thermal conductivity of the fluid So I looked up the thermal conductivity of the fluid as well But if I didn't remember to do that, if I didn't sort of have the foresight to see I was gonna have to do this Then I could just look that up now and If I do that, I can find a heat transfer coefficient on the cold side, which is nice I already know the heat transfer coefficient on the hot side so I can put this information into this equation and I can find that my effective heat transfer coefficient is 354 watt per meter squared Kelvin

So now I have the information that I need to calculate the area of my tubes So I can put this in again. We're gonna check through our units and we find that we need almost 30 square meters of tube Right, and we know that there's I think there's 10 of these tubes, right? So there's kind of a bundle of tubes and then each one snakes through eight times So if I look at the problem, I know that the total area is going to be the number of tubes Times the perimeter of each tube which is pi times D times 8 lengths So again, I guess it's important to realize that I'm neglecting What's going on when these tubes are turning around?

So then I can rearrange this equation for L And I know the area. I know the number of tubes times the number of passes So that's 80 and then I know that we have pi Times D here and D is known So again, if you were doing this on a test I Defined L. Which wasn't very well defined in the problem But I defined L as the length of a tube pass if you would have said the total length of all the tubes Then you would just be 80 times higher than this So I get the length of each pass is about four point seven meters, so it's pretty big Right, and I don't know maybe some of you have been on some coops where you have seen some pretty enormous heat exchangers So, you know maybe maybe you think if this is being big or maybe you think of it as As being small depending on what your experience has been

So this is what the problem asked us for. So now We're finished with the problem All right, so we can celebrate Does anybody have questions about this problem? All right, I will close down this window

So, this is our last heat exchanger problem And here we have truck coolant is cooled by air in a cross flow heat exchanger Where both fluids are unmixed so I know the terminology here can be a little bit tricky Unmixed means that my flow is separated into different channels or different tubes So here we have one flow going through our tubes labeled as fluid a in this picture Right, so it's all separated into tubes and the flow in those tubes. They can't mix with the flow and the other tubes

So it's unmixed Now fluid B here is running over these tubes But the way we would imagine it is that there's fins or plates that are connecting holding all these tubes together So maybe they're all braised in together in these sort of You know separated by these fins So that the fluid once it passes into the heat exchanger Can't come over these fins. So the air flow or the flow in fluid B Also can't mix with the flow and the other fluid channels So fluid a is separated into tubes and fluid B is separated into channels. So both of these lows are unmixed

it tells us that atmospheric air enters at 30 degrees Celsius with a particular mass flow rate and water enters with another mass flow rate at 75 degrees Celsius and it tells us the diameter of the tubes It tells us the overall heat transfer coefficient, which is always nice That means that we we won't have to do any kind of internal convection analysis and the total heat transfer area So now it asks us what's the temperature of the water? So this one's a little different than the last one we did because here we know the size

We just don't know how much heat is being transferred So we know the temperature on the hot side Inlet and the mass flow-rate We know the mass flow rate and the temperature of the cold Inlet, but we don't know either outlet temperature So this is one of the times where even for complicated geometries you can use the log mean temperature difference You just have to look it up on some kind of like ugly table And try to graphically read it. So I think effectiveness NTU is a good idea For these complicated geometries, but here because we don't know either outlet temperature We would not be able to use the log mean temperature difference Even if we were willing to look it up on a look up on a chart or something

So we're told some things about the heat exchanger like the effective heat transfer coefficient and the area And we're asked to find the hot outlet temperature but once we knew that like we could ask this question to also find the cold outlet temperature or the amount of heat that's being transferred So we'll assume the problem is at steady state That the fluid and material properties are constant that there's no losses to the surroundings and that The fluid is unmixed on both sides So again, we want to go back to this two-by-two matrix So our objective in this case is to find the amount of heat transfer So because we didn't know the outlet temperatures on either side There's no way for us to quickly find out how much heat is being transferred because we don't know what's going on on the hot side or the cold side and Because I don't know any of the outlet temperatures or I don't know delta T on either side

I have to use the effectiveness NTU method, but I would choose to use it on this in this case anyway Because we're not just dealing with a counter flow or parallel flow heat exchanger So here I know the process that I'm going to use so I have a flow chart I Want to pick the geometry find my Big C values Find the NTU from the definition Use an expression or correlation to find effectiveness Calculate Q max and then with Q Max and effectiveness calculate the actual amount of heat transfer So first, we'll try to pick the geometry so we know that we have a cross flow heat exchanger and it's unmixed on the hot side and unmixed on the cold side

So because it's unmixed on both sides Then I go to my table here 11.3. I look at cross-flow With single passes. So none of these flows are doubling back and pushing back around and We have it's the flow is unmixed on both sides. So I have one expression here that Gives me effectiveness as a function of NTU and CR So this is what that expression looks like So I got to find CR To find CR I do the next thing on my flow chart which is how do I find all my values of Big C?

So for Big C we need to know specificity we need to know values of specific heat for both fluids but In order to find the specific heat to get the best estimate We would need to know the average temperature on the hot side and the average temperature on the cold side But because we don't know the outlet temperatures on either side, we'll have to estimate for both So first for the air I'm going to look, so I know that it has to be between 300 degrees and 350 degrees Kelvin So here if we look at CP He's a very weak function, right? So I would be fine on a test if you picked a thousand and seven or a thousand and nine I just know it has to be somewhere in between there. So I picked a thousand and eight joules per kilogram Kelvin So then I put this into my problem and I can find Big C on the cold side

We'll do the same thing on the hot side so here again I look at, I know it's coming in at 348 degrees Kelvin, and I know it has to cool down Right, so I'm gonna say it cools down to about 300 Kelvin So I'm gonna assume that my temperature is 325 degrees Kelvin So here when I pull this off I get 4181 I guess I picked something a little lower than this or maybe I just wrote down the number wrong, but again, you can see that the specific heat of the fluid is not a big function of The temperature so I'm just gonna pick a number here. I Put that in and I find Big C on the hot side

So now I want to compare these two things so I know that the Big C on the hot side is Five times less than the Big C on the cold side So semen is on the hot side and C max is on the cold side I take the ratio where the ratio is always less than one and I find that it's about 20% or 0.2 So now I can try to find NTU So, I know my definition for NTU is gonna be my effective heat transfer coefficient multiplied by the area Divided by C min. So I already know what C min is the problem was nice to me because it told me what the effective heat transfer coefficient was and I know the area so Here I can see that. My NTU is just about 0.5

Now that I know NTU I can go back to my equation for effectiveness Which is a function of NTU and CR and I've done some work to find both of those things So now I can plug them back into this equation So here I have this equation I Know CR and I know NTU so I can put those numbers into my calculator Again I like to simplify as I go along because I don't trust myself to just put it all into my calculator at once and I see my effectiveness is 0.37 So it's good that I know effectiveness, but the reason that I want to know the effectiveness is That effectiveness is going to be Q actual over Q max So if I knew Q max? Then I can find Q actual. So the next thing on my list is to find Q max