1. Home
  2. Explore
  3. Education
  4. Student Feedback on Course Changes

Study methods

Flashcards
Quiz
Fill in the blanks
Written test
Lesson
Notes
Podcast
Content

Student Feedback on Course Changes

  • 52Unfamiliar
  • 0Learning
  • 0Familiar
  • 0Mastered
Topic: Heat Exchanger Fundamentals

For an insulated heat exchanger operating at steady state, how are the heat lost by the hot fluid and the heat gained by the cold fluid related?

52 questions

  1. 1

    For an insulated heat exchanger operating at steady state, how are the heat lost by the hot fluid and the heat gained by the cold fluid related?

    1. A

      The hot fluid loses more heat because the tube wall absorbs the difference.

    2. B

      They are equal in magnitude, with no heat transferred to the surroundings.

    3. C

      The cold fluid gains more heat because its outlet temperature is lower.

    4. D

      They are equal only when the two fluids have the same mass flow rate.

    Correct answer
    B

    They are equal in magnitude, with no heat transferred to the surroundings.

    Explanation

    With no heat loss to the surroundings, energy conservation requires that the heat lost by the hot stream equal the heat gained by the cold stream in magnitude.

  2. 2

    For a fluid with no phase change, which expression gives its heat-capacity rate?

    1. A

      C=m˙cpΔTC = \dot{m}c_p\Delta TC=m˙cp​ΔT

    2. B

      C=m˙cpC = \dot{m}c_pC=m˙cp​

    3. C

      C=cp/m˙C = c_p/\dot{m}C=cp​/m˙

    4. D

      C=m˙/cpC = \dot{m}/c_pC=m˙/cp​

    Correct answer
    B

    C=m˙cpC = \dot{m}c_pC=m˙cp​

    Explanation

    The heat-capacity rate is mass flow rate multiplied by specific heat: C=m˙cpC = \dot{m}c_pC=m˙cp​. It relates heat transfer rate to the stream's temperature change.

  3. 3

    A problem asks for the heat-transfer surface area needed to meet specified operating conditions. What type of heat-exchanger task is this?

    1. A

      A property task, because the fluid's specific heat must be determined.

    2. B

      A rating task, because the heat-transfer rate must be determined from a known size.

    3. C

      A sizing task, because the required exchanger size must be determined.

    4. D

      A flow task, because the exchanger's pressure drop must be determined.

    Correct answer
    C

    A sizing task, because the required exchanger size must be determined.

    Explanation

    Finding the required area or length determines the exchanger's size, so it is a sizing task. A rating task instead predicts performance for a known exchanger.

  4. 4

    When is the log mean temperature difference method especially convenient for a heat exchanger?

    1. A

      When neither outlet temperature is known and the exchanger geometry is complex.

    2. B

      When the fluids change phase and their specific heats are unavailable.

    3. C

      When the inlet and outlet temperatures of both fluids are known.

    4. D

      When the heat-transfer area is known but both inlet temperatures are unknown.

    Correct answer
    C

    When the inlet and outlet temperatures of both fluids are known.

    Explanation

    The log mean temperature difference method uses terminal temperature differences, so it is convenient when the inlet and outlet temperatures of both streams are known.

  5. 5

    A heat exchanger has a complex flow arrangement, and one or both outlet temperatures are unknown. Which method is generally the better choice?

    1. A

      The effectiveness–NTU method, because it can be used without knowing both outlet temperatures.

    2. B

      A resistance-network method, because it directly determines both outlet temperatures.

    3. C

      A conduction-only method, because fluid flow details are not needed.

    4. D

      The log mean temperature difference method, because it requires only inlet temperatures.

    Correct answer
    A

    The effectiveness–NTU method, because it can be used without knowing both outlet temperatures.

    Explanation

    The effectiveness–NTU method is useful for complex geometries and cases where outlet temperatures are not known. The log mean temperature difference method requires the terminal temperature differences.

  6. 6

    Which equation expresses heat transfer using the log mean temperature difference?

    1. A

      Q=UA/ΔTlmQ = UA/\Delta T_{\mathrm{lm}}Q=UA/ΔTlm​

    2. B

      Q=AΔTlm/UQ = A\Delta T_{\mathrm{lm}}/UQ=AΔTlm​/U

    3. C

      Q=UΔTlm/AQ = U\Delta T_{\mathrm{lm}}/AQ=UΔTlm​/A

    4. D

      Q=UAΔTlmQ = UA\Delta T_{\mathrm{lm}}Q=UAΔTlm​

    Correct answer
    D

    Q=UAΔTlmQ = UA\Delta T_{\mathrm{lm}}Q=UAΔTlm​

    Explanation

    For the log mean temperature difference method, the heat-transfer rate is Q=UAΔTlmQ = UA\Delta T_{\mathrm{lm}}Q=UAΔTlm​, where UUU is the effective heat-transfer coefficient and AAA is the transfer area.

  7. 7

    In the effectiveness–NTU method, how is the number of transfer units defined?

    1. A

      NTU=UA/Cmax⁡\mathrm{NTU} = UA/C_{\max}NTU=UA/Cmax​

    2. B

      NTU=U/(ACmin⁡)\mathrm{NTU} = U/(AC_{\min})NTU=U/(ACmin​)

    3. C

      NTU=UA/Cmin⁡\mathrm{NTU} = UA/C_{\min}NTU=UA/Cmin​

    4. D

      NTU=Cmin⁡/UA\mathrm{NTU} = C_{\min}/UANTU=Cmin​/UA

    Correct answer
    C

    NTU=UA/Cmin⁡\mathrm{NTU} = UA/C_{\min}NTU=UA/Cmin​

    Explanation

    The number of transfer units is defined as NTU=UA/Cmin⁡\mathrm{NTU} = UA/C_{\min}NTU=UA/Cmin​. This relationship can be rearranged to determine the required heat-transfer area.

  8. 8

    If the tube diameter is held constant, what does increasing the heat-transfer area of a straight tube primarily require?

    1. A

      Increasing the tube length, because area depends on perimeter multiplied by length.

    2. B

      Decreasing the tube length, because a smaller exchanger transfers more heat per area.

    3. C

      Increasing the fluid specific heat, because it sets the geometric surface area.

    4. D

      Decreasing the flow rate, because it directly increases the tube perimeter.

    Correct answer
    A

    Increasing the tube length, because area depends on perimeter multiplied by length.

    Explanation

    For a cylindrical tube, the transfer area is its perimeter multiplied by its length. If the diameter is fixed, increasing the area requires increasing the length.

  9. 9

    For parallel flow, which terminal temperature differences are used in the log mean temperature difference calculation?

    1. A

      Th,in−Tc,outT_{h,in}-T_{c,out}Th,in​−Tc,out​ and Th,out−Tc,inT_{h,out}-T_{c,in}Th,out​−Tc,in​

    2. B

      Th,in−Th,outT_{h,in}-T_{h,out}Th,in​−Th,out​ and Tc,in−Tc,outT_{c,in}-T_{c,out}Tc,in​−Tc,out​

    3. C

      Th,in−Tc,inT_{h,in}-T_{c,in}Th,in​−Tc,in​ and Th,out−Tc,outT_{h,out}-T_{c,out}Th,out​−Tc,out​

    4. D

      Th,out−Tc,inT_{h,out}-T_{c,in}Th,out​−Tc,in​ and Th,in−Tc,outT_{h,in}-T_{c,out}Th,in​−Tc,out​

    Correct answer
    C

    Th,in−Tc,inT_{h,in}-T_{c,in}Th,in​−Tc,in​ and Th,out−Tc,outT_{h,out}-T_{c,out}Th,out​−Tc,out​

    Explanation

    In parallel flow, the fluids enter at the same end and leave at the same end. The terminal differences are therefore between the two inlet temperatures and between the two outlet temperatures.

  10. 10

    For counterflow, which terminal temperature differences are used in the log mean temperature difference calculation?

    1. A

      Th,out−Tc,outT_{h,out}-T_{c,out}Th,out​−Tc,out​ and Th,in−Tc,inT_{h,in}-T_{c,in}Th,in​−Tc,in​

    2. B

      Th,in−Tc,inT_{h,in}-T_{c,in}Th,in​−Tc,in​ and Th,out−Tc,outT_{h,out}-T_{c,out}Th,out​−Tc,out​

    3. C

      Th,in−Th,outT_{h,in}-T_{h,out}Th,in​−Th,out​ and Tc,in−Tc,outT_{c,in}-T_{c,out}Tc,in​−Tc,out​

    4. D

      Th,in−Tc,outT_{h,in}-T_{c,out}Th,in​−Tc,out​ and Th,out−Tc,inT_{h,out}-T_{c,in}Th,out​−Tc,in​

    Correct answer
    D

    Th,in−Tc,outT_{h,in}-T_{c,out}Th,in​−Tc,out​ and Th,out−Tc,inT_{h,out}-T_{c,in}Th,out​−Tc,in​

    Explanation

    In counterflow, the hot inlet is adjacent to the cold outlet, and the hot outlet is adjacent to the cold inlet. Those pairings determine the two terminal temperature differences.

  11. 11

    Why do the terminal temperature-difference pairings differ between parallel-flow and counterflow exchangers?

    1. A

      The fluids contact different ends of one another because their flow directions differ.

    2. B

      The fluids have different specific heats in the two arrangements.

    3. C

      Counterflow exchangers always have a different tube-wall material.

    4. D

      Parallel-flow exchangers transfer heat only at the inlet ends.

    Correct answer
    A

    The fluids contact different ends of one another because their flow directions differ.

    Explanation

    The flow directions determine which hot-fluid and cold-fluid temperatures are adjacent at each end of the exchanger. Parallel flow pairs inlet with inlet and outlet with outlet; counterflow pairs hot inlet with cold outlet and hot outlet with cold inlet.

  12. 12

    For the same inlet temperatures, what is a typical temperature-profile advantage of counterflow over parallel flow?

    1. A

      It prevents either fluid from changing temperature along the exchanger.

    2. B

      It makes the temperature difference zero over the entire exchanger length.

    3. C

      It ensures that the cold outlet is always colder than the hot outlet.

    4. D

      It tends to maintain a more uniform temperature difference along the exchanger.

    Correct answer
    D

    It tends to maintain a more uniform temperature difference along the exchanger.

    Explanation

    The described counterflow arrangement maintains a more consistent temperature difference along the exchanger length than parallel flow, which generally improves heat-transfer performance.

  13. 13

    If two exchangers transfer the same heat with the same effective heat-transfer coefficient, how does a larger log mean temperature difference affect the required area?

    1. A

      It reduces the required area, because the same heat transfer can occur across a larger driving temperature difference.

    2. B

      It makes the required area depend only on the mass flow rates.

    3. C

      It leaves the required area unchanged, because area is independent of temperature difference.

    4. D

      It increases the required area, because a larger temperature difference raises the thermal resistance.

    Correct answer
    A

    It reduces the required area, because the same heat transfer can occur across a larger driving temperature difference.

    Explanation

    From Q=UAΔTlmQ = UA\Delta T_{\mathrm{lm}}Q=UAΔTlm​, for fixed QQQ and UUU, a larger log mean temperature difference means a smaller area is needed.

  14. 14

    In the illustrated cooling example, which configuration required less heat-transfer area?

    1. A

      Counterflow, with about 3.13 m23.13\,\text{m}^23.13m2 rather than 2.68 m22.68\,\text{m}^22.68m2.

    2. B

      Parallel flow, with about 2.68 m22.68\,\text{m}^22.68m2 rather than 3.13 m23.13\,\text{m}^23.13m2.

    3. C

      Both configurations, because they required exactly the same area.

    4. D

      Counterflow, with about 2.68 m22.68\,\text{m}^22.68m2 rather than 3.13 m23.13\,\text{m}^23.13m2.

    Correct answer
    D

    Counterflow, with about 2.68 m22.68\,\text{m}^22.68m2 rather than 3.13 m23.13\,\text{m}^23.13m2.

    Explanation

    The example calculated about 3.13 m23.13\,\text{m}^23.13m2 for parallel flow and about 2.68 m22.68\,\text{m}^22.68m2 for counterflow. Counterflow required less area.

  15. 15

    In that cooling example, approximately how much did changing from parallel flow to counterflow reduce the required area?

    1. A

      About 40%40\%40%

    2. B

      About 24%24\%24%

    3. C

      About 4%4\%4%

    4. D

      About 14%14\%14%

    Correct answer
    D

    About 14%14\%14%

    Explanation

    The example reported that the counterflow arrangement reduced the required area by approximately 14%14\%14% compared with parallel flow.

  16. 16

    Why can a counterflow exchanger often be smaller than a parallel-flow exchanger for a comparable duty?

    1. A

      It removes the need to account for the exchanger's heat-transfer coefficient.

    2. B

      It eliminates the need for convection on one side of the tube.

    3. C

      Its more favorable temperature profile can provide a larger log mean temperature difference.

    4. D

      It makes the heat-capacity rates of both fluids equal.

    Correct answer
    C

    Its more favorable temperature profile can provide a larger log mean temperature difference.

    Explanation

    Counterflow commonly provides a larger log mean temperature difference by maintaining a more favorable temperature profile. For the same duty and overall coefficient, that can reduce required area.

  17. 17

    A shell-and-tube exchanger has no internal baffles that redirect the shell-side flow. How many shell passes does this arrangement have?

    1. A

      A number of shell passes equal to the number of tube passes

    2. B

      Two shell passes

    3. C

      One shell pass per tube

    4. D

      One shell pass

    Correct answer
    D

    One shell pass

    Explanation

    In the described exchanger, there are no baffles directing the shell-side fluid through repeated passes, so it is treated as a one-shell-pass arrangement.

  18. 18

    In the shell-and-tube example, what does an even number of tube passes indicate about the tube-side flow path?

    1. A

      The fluid flows once through the shell and never changes direction.

    2. B

      The exchanger contains an equal number of shell and tube passes.

    3. C

      The shell-side fluid is divided into the same number of separate passes.

    4. D

      The fluid makes repeated traversals through the shell and returns to the starting end.

    Correct answer
    D

    The fluid makes repeated traversals through the shell and returns to the starting end.

    Explanation

    Multiple tube passes mean the tube-side fluid travels back and forth through the shell. An even number of passes allows it to return to the starting end.

  19. 19

    How is a tube pass described in the shell-and-tube example?

    1. A

      One complete round trip from the inlet back to the inlet

    2. B

      One traversal along the shell through the tube path

    3. C

      One tube in the entire bundle, regardless of its path

    4. D

      One traversal of the shell-side fluid between two baffles

    Correct answer
    B

    One traversal along the shell through the tube path

    Explanation

    A pass is one traversal along the shell through the tube path. Returning to the starting end requires another pass.

  20. 20

    Which effectiveness–NTU correlation category matches a one-shell-pass exchanger with an even number of tube passes?

    1. A

      The parallel-flow, equal-capacity-rate relation

    2. B

      The one-shell-pass, even-tube-pass relation

    3. C

      The unmixed crossflow, multiple-shell-pass relation

    4. D

      The two-shell-pass, single-tube-pass relation

    Correct answer
    B

    The one-shell-pass, even-tube-pass relation

    Explanation

    The correlation must match the exchanger geometry. The example uses the relation for one shell pass and an even number of tube passes.

  21. 21

    In the shell-and-tube example, how can the unknown hot-oil mass flow rate be found if the cold-side inlet and outlet conditions are known?

    1. A

      Find the hot-side area from the number of tubes, then infer the mass flow rate from area.

    2. B

      Set the hot and cold mass flow rates equal, then use the hot inlet temperature.

    3. C

      Find the heat gained by the cold stream, set it equal to the heat lost by the hot stream, and solve for the hot flow rate.

    4. D

      Set the hot and cold outlet temperatures equal, then solve for the hot flow rate.

    Correct answer
    C

    Find the heat gained by the cold stream, set it equal to the heat lost by the hot stream, and solve for the hot flow rate.

    Explanation

    First determine the heat transfer from the known cold-side conditions. Under the insulated-exchanger assumption, that heat equals the hot-side heat loss, which can be used to solve for the unknown hot-side mass flow rate.

  22. 22

    How should Cmin⁡C_{\min}Cmin​ and Cmax⁡C_{\max}Cmax​ be identified after calculating the two stream heat-capacity rates?

    1. A

      Cmin⁡C_{\min}Cmin​ is the average of the two rates, and Cmax⁡C_{\max}Cmax​ is their difference.

    2. B

      Cmin⁡C_{\min}Cmin​ is the rate with the larger mass flow, and Cmax⁡C_{\max}Cmax​ is the other rate.

    3. C

      Cmin⁡C_{\min}Cmin​ is the smaller rate, and Cmax⁡C_{\max}Cmax​ is the larger rate.

    4. D

      Cmin⁡C_{\min}Cmin​ is always the hot-side rate, and Cmax⁡C_{\max}Cmax​ is always the cold-side rate.

    Correct answer
    C

    Cmin⁡C_{\min}Cmin​ is the smaller rate, and Cmax⁡C_{\max}Cmax​ is the larger rate.

    Explanation

    The subscripts refer to the numerical sizes of the heat-capacity rates: Cmin⁡C_{\min}Cmin​ is the smaller, and Cmax⁡C_{\max}Cmax​ is the larger. Their ratio is Cr=Cmin⁡/Cmax⁡C_r=C_{\min}/C_{\max}Cr​=Cmin​/Cmax​.

  23. 23

    Which definition of effectiveness is used in the effectiveness–NTU method?

    1. A

      ε=Cmax⁡/Cmin⁡\varepsilon = C_{\max}/C_{\min}ε=Cmax​/Cmin​

    2. B

      ε=Qactual/Qmax⁡\varepsilon = Q_{\mathrm{actual}}/Q_{\max}ε=Qactual​/Qmax​

    3. C

      ε=NTU/Qactual\varepsilon = \mathrm{NTU}/Q_{\mathrm{actual}}ε=NTU/Qactual​

    4. D

      ε=Qmax⁡/Qactual\varepsilon = Q_{\max}/Q_{\mathrm{actual}}ε=Qmax​/Qactual​

    Correct answer
    B

    ε=Qactual/Qmax⁡\varepsilon = Q_{\mathrm{actual}}/Q_{\max}ε=Qactual​/Qmax​

    Explanation

    Effectiveness compares the actual heat transfer with the maximum possible heat transfer: ε=Qactual/Qmax⁡\varepsilon = Q_{\mathrm{actual}}/Q_{\max}ε=Qactual​/Qmax​.

  24. 24

    How is the maximum possible heat-transfer rate calculated for an exchanger with no phase change?

    1. A

      Qmax⁡=Cmin⁡(Th,in−Tc,in)Q_{\max}=C_{\min}(T_{h,in}-T_{c,in})Qmax​=Cmin​(Th,in​−Tc,in​)

    2. B

      Qmax⁡=Cmax⁡(Th,out−Tc,out)Q_{\max}=C_{\max}(T_{h,out}-T_{c,out})Qmax​=Cmax​(Th,out​−Tc,out​)

    3. C

      Qmax⁡=Cmax⁡(Th,in−Tc,in)Q_{\max}=C_{\max}(T_{h,in}-T_{c,in})Qmax​=Cmax​(Th,in​−Tc,in​)

    4. D

      Qmax⁡=Cmin⁡(Th,out−Tc,in)Q_{\max}=C_{\min}(T_{h,out}-T_{c,in})Qmax​=Cmin​(Th,out​−Tc,in​)

    Correct answer
    A

    Qmax⁡=Cmin⁡(Th,in−Tc,in)Q_{\max}=C_{\min}(T_{h,in}-T_{c,in})Qmax​=Cmin​(Th,in​−Tc,in​)

    Explanation

    The maximum possible heat transfer uses the smaller heat-capacity rate and the largest inlet temperature difference: Qmax⁡=Cmin⁡(Th,in−Tc,in)Q_{\max}=C_{\min}(T_{h,in}-T_{c,in})Qmax​=Cmin​(Th,in​−Tc,in​).

  25. 25

    In the shell-and-tube example, why was the cold-side stream identified as the minimum-capacity-rate stream?

    1. A

      Its specific heat was lower than the hot fluid's specific heat.

    2. B

      Its calculated heat-capacity rate was lower than the hot-side rate.

    3. C

      It flowed through the tubes rather than around the shell.

    4. D

      Its inlet temperature was lower than the hot-side inlet temperature.

    Correct answer
    B

    Its calculated heat-capacity rate was lower than the hot-side rate.

    Explanation

    The minimum-capacity-rate stream is determined by comparing the calculated values of m˙cp\dot{m}c_pm˙cp​ for both fluids. In the example, the cold-side value was smaller.

  26. 26

    If the total tube area is known for a bundle with NNN tubes, PPP passes, and tube diameter DDD, how can the length LLL of one pass be related to that area?

    1. A

      A=PπDL/NA=P\pi D L/NA=PπDL/N

    2. B

      A=NPD/LA=N P D/LA=NPD/L

    3. C

      A=NPπDLA=N P\pi D LA=NPπDL

    4. D

      A=NπDL/PA=N\pi D L/PA=NπDL/P

    Correct answer
    C

    A=NPπDLA=N P\pi D LA=NPπDL

    Explanation

    Each tube pass contributes an area equal to its circumference, πD\pi DπD, multiplied by its length. Summing over NNN tubes and PPP passes gives A=NPπDLA=NP\pi DLA=NPπDL.

  27. 27

    When estimating the length of each tube pass in the shell-and-tube example, which part of the tube path was neglected?

    1. A

      Convection between the tube wall and the cold fluid

    2. B

      Heat transfer in the bends where tubes turn around

    3. C

      Heat transfer along the straight tube sections

    4. D

      Convection between the hot fluid and the tube wall

    Correct answer
    B

    Heat transfer in the bends where tubes turn around

    Explanation

    The example treated the straight pass length as the relevant length and assumed heat transfer in the turnaround sections was negligible.

  28. 28

    In a crossflow exchanger, what does it mean for a fluid to be unmixed?

    1. A

      The fluid has no temperature change as it passes through the exchanger.

    2. B

      The fluid is stationary while the other stream flows across it.

    3. C

      The fluid flows in the same direction as the other stream.

    4. D

      The fluid remains separated into channels and does not mix across them.

    Correct answer
    D

    The fluid remains separated into channels and does not mix across them.

    Explanation

    An unmixed stream is confined to separate tubes or channels, so it cannot mix with fluid in neighboring passages.

  29. 29

    In the described crossflow exchanger, why is the air stream also considered unmixed?

    1. A

      The air changes phase before reaching the outlet.

    2. B

      Fins or plates keep the air in separate channels as it passes across the tubes.

    3. C

      The air flows parallel to the water through the exchanger.

    4. D

      The air travels inside the same tubes as the water.

    Correct answer
    B

    Fins or plates keep the air in separate channels as it passes across the tubes.

    Explanation

    The air-side flow is considered unmixed because fins or plates separate its channels and prevent it from mixing across them.

  30. 30

    For a single-pass crossflow exchanger with both fluids unmixed, which kind of relationship should be used to connect effectiveness, NTU, and the capacity-rate ratio?

    1. A

      The counterflow relation for equal capacity rates

    2. B

      The parallel-flow relation for one mixed stream

    3. C

      The crossflow correlation for both streams unmixed

    4. D

      The shell-and-tube relation for multiple tube passes

    Correct answer
    C

    The crossflow correlation for both streams unmixed

    Explanation

    Effectiveness depends on exchanger geometry and mixing conditions. For this case, the appropriate relation is the single-pass crossflow correlation with both streams unmixed.

  31. 31

    If neither outlet temperature is known in a heat-exchanger problem, why can the log mean temperature difference method not be applied directly?

    1. A

      The method requires the two mass flow rates to be equal.

    2. B

      The method cannot be used when the streams have different specific heats.

    3. C

      The terminal temperature differences cannot be calculated without the outlet temperatures.

    4. D

      The method applies only when the heat-transfer area is unknown.

    Correct answer
    C

    The terminal temperature differences cannot be calculated without the outlet temperatures.

    Explanation

    The log mean temperature difference requires temperature differences at both ends of the exchanger. If outlet temperatures are unknown, those terminal differences are not yet available.

  32. 32

    When the overall heat-transfer coefficient and area are given but outlet temperatures are unknown, what can be calculated first in an effectiveness–NTU analysis?

    1. A

      The log mean temperature difference, using only the inlet temperatures

    2. B

      The tube length, even if the exchanger area is unknown

    3. C

      NTU, using NTU=UA/Cmin⁡\mathrm{NTU}=UA/C_{\min}NTU=UA/Cmin​

    4. D

      The outlet temperatures, without first determining heat transfer

    Correct answer
    C

    NTU, using NTU=UA/Cmin⁡\mathrm{NTU}=UA/C_{\min}NTU=UA/Cmin​

    Explanation

    With UUU, AAA, and Cmin⁡C_{\min}Cmin​ known, NTU can be calculated directly from NTU=UA/Cmin⁡\mathrm{NTU}=UA/C_{\min}NTU=UA/Cmin​. Effectiveness can then be found from the correlation for the exchanger geometry.

  33. 33

    In the crossflow example, the hot-side heat-capacity rate was much smaller than the cold-side rate. Which conclusion follows?

    1. A

      The hot side has Cmax⁡C_{\max}Cmax​, and the capacity-rate ratio is about 111.

    2. B

      The hot side has Cmin⁡C_{\min}Cmin​, and the capacity-rate ratio is about 0.20.20.2.

    3. C

      The cold side has Cmax⁡C_{\max}Cmax​, and the capacity-rate ratio is about 0.20.20.2.

    4. D

      The cold side has Cmin⁡C_{\min}Cmin​, and the capacity-rate ratio is about 555.

    Correct answer
    B

    The hot side has Cmin⁡C_{\min}Cmin​, and the capacity-rate ratio is about 0.20.20.2.

    Explanation

    The hot-side rate was about one-fifth of the cold-side rate, so it was Cmin⁡C_{\min}Cmin​. Thus, Cr=Cmin⁡/Cmax⁡C_r=C_{\min}/C_{\max}Cr​=Cmin​/Cmax​ was about 0.20.20.2.

  34. 34

    Once effectiveness and maximum possible heat transfer are known, how is the actual heat-transfer rate found?

    1. A

      Qactual=εQmax⁡Q_{\mathrm{actual}}=\varepsilon Q_{\max}Qactual​=εQmax​

    2. B

      Qactual=Qmax⁡−εQ_{\mathrm{actual}}=Q_{\max}-\varepsilonQactual​=Qmax​−ε

    3. C

      Qactual=Qmax⁡/εQ_{\mathrm{actual}}=Q_{\max}/\varepsilonQactual​=Qmax​/ε

    4. D

      Qactual=ε/Qmax⁡Q_{\mathrm{actual}}=\varepsilon/Q_{\max}Qactual​=ε/Qmax​

    Correct answer
    A

    Qactual=εQmax⁡Q_{\mathrm{actual}}=\varepsilon Q_{\max}Qactual​=εQmax​

    Explanation

    Rearranging ε=Qactual/Qmax⁡\varepsilon=Q_{\mathrm{actual}}/Q_{\max}ε=Qactual​/Qmax​ gives Qactual=εQmax⁡Q_{\mathrm{actual}}=\varepsilon Q_{\max}Qactual​=εQmax​.

  35. 35

    After calculating the actual heat transfer in a crossflow exchanger, how can the hot outlet temperature be determined?

    1. A

      Set Th,out=Tc,outT_{h,out}=T_{c,out}Th,out​=Tc,out​ because both streams exchange the same heat.

    2. B

      Use Qactual=Ch(Th,in−Th,out)Q_{\mathrm{actual}}=C_h(T_{h,in}-T_{h,out})Qactual​=Ch​(Th,in​−Th,out​) and solve for Th,outT_{h,out}Th,out​.

    3. C

      Use Qactual=UA(Th,in−Th,out)Q_{\mathrm{actual}}=UA(T_{h,in}-T_{h,out})Qactual​=UA(Th,in​−Th,out​) without a temperature profile.

    4. D

      Use Qactual=Cc(Th,in−Tc,in)Q_{\mathrm{actual}}=C_c(T_{h,in}-T_{c,in})Qactual​=Cc​(Th,in​−Tc,in​) and solve for Th,outT_{h,out}Th,out​.

    Correct answer
    B

    Use Qactual=Ch(Th,in−Th,out)Q_{\mathrm{actual}}=C_h(T_{h,in}-T_{h,out})Qactual​=Ch​(Th,in​−Th,out​) and solve for Th,outT_{h,out}Th,out​.

    Explanation

    For the hot stream, the heat lost is Qactual=Ch(Th,in−Th,out)Q_{\mathrm{actual}}=C_h(T_{h,in}-T_{h,out})Qactual​=Ch​(Th,in​−Th,out​). Solving this energy balance gives the hot outlet temperature.

  36. 36

    Why might a specific heat be estimated using an assumed average fluid temperature when outlet conditions are unknown?

    1. A

      Specific heat is defined only at the midpoint between the inlet and outlet temperatures.

    2. B

      The average temperature is needed to select a representative temperature-dependent property value.

    3. C

      The average temperature guarantees that both outlet temperatures are equal.

    4. D

      The assumed temperature makes the fluid's mass flow rate unnecessary.

    Correct answer
    B

    The average temperature is needed to select a representative temperature-dependent property value.

    Explanation

    When fluid properties vary with temperature and the outlet is unknown, an estimated average temperature provides a practical basis for selecting a representative specific heat.

  37. 37

    Why was a rough specific-heat estimate considered acceptable in the examples?

    1. A

      The exchanger's heat-transfer coefficient replaces the need for specific heat.

    2. B

      The heat-capacity rate does not depend on specific heat.

    3. C

      The specific heat of the liquids discussed varies only weakly over the estimated temperature range.

    4. D

      Specific heat is identical for all liquids at every temperature.

    Correct answer
    C

    The specific heat of the liquids discussed varies only weakly over the estimated temperature range.

    Explanation

    The examples noted that liquid specific heat was a weak function of temperature over the relevant range, so a reasonable estimate was unlikely to greatly change the result.

  38. 38

    When using a saturated-water property table for liquid water, which specific-heat entry should be selected?

    1. A

      The saturated-vapor entry, labeled cp,gc_{p,g}cp,g​

    2. B

      The saturated-liquid entry, labeled cp,fc_{p,f}cp,f​

    3. C

      The vapor-quality entry, labeled cp,xc_{p,x}cp,x​

    4. D

      The mixture entry, labeled cp,fgc_{p,fg}cp,fg​

    Correct answer
    B

    The saturated-liquid entry, labeled cp,fc_{p,f}cp,f​

    Explanation

    For saturated liquid water, the appropriate specific heat is the saturated-liquid value, labeled cp,fc_{p,f}cp,f​. The ggg label refers to saturated vapor.

  39. 39

    Why should an estimated fluid property be checked against the calculated outlet temperature?

    1. A

      The check removes the need to conserve energy across the exchanger.

    2. B

      The check determines whether the exchanger has a parallel-flow geometry.

    3. C

      The check reveals whether the assumed average temperature was reasonable.

    4. D

      The check proves that no heat was transferred to the cold stream.

    Correct answer
    C

    The check reveals whether the assumed average temperature was reasonable.

    Explanation

    Comparing the calculated outlet temperature with the assumed average-temperature estimate helps assess whether the property value was chosen consistently. If greater accuracy is needed, the estimate can be updated and the calculation repeated.

  40. 40

    Why might specific-heat values need to be converted from kilojoules per kilogram-kelvin to joules per kilogram-kelvin during a calculation?

    1. A

      To ensure the heat-capacity rate is measured in area units.

    2. B

      To keep units consistent when calculating heat-transfer rates in watts.

    3. C

      To convert the specific heat into a mass flow rate.

    4. D

      To make the fluid temperature independent of the chosen scale.

    Correct answer
    B

    To keep units consistent when calculating heat-transfer rates in watts.

    Explanation

    A watt is a joule per second. Converting specific heat into joules per kilogram-kelvin helps keep units consistent when combining it with mass flow rate to calculate heat-transfer rates in watts.

  41. 41

    Which set of assumptions was used to simplify the heat-exchanger analyses?

    1. A

      Unsteady operation, variable properties, heat loss to surroundings, and strong axial conduction

    2. B

      Steady state, constant properties, no heat loss to surroundings, and negligible axial conduction

    3. C

      Constant outlet temperatures, equal flow rates, and negligible heat transfer between fluids

    4. D

      Steady state, phase change in both fluids, and no convection at the tube walls

    Correct answer
    B

    Steady state, constant properties, no heat loss to surroundings, and negligible axial conduction

    Explanation

    The analyses assumed steady operation, constant fluid and material properties, an insulated exchanger, and negligible axial conduction along the tube.

  42. 42

    What is the purpose of assuming a thin tube wall with no fouling on either side?

    1. A

      It makes the heat-transfer area independent of the tube dimensions.

    2. B

      It eliminates the need to consider convection on either fluid side.

    3. C

      It allows wall-conduction and fouling resistances to be neglected when estimating the effective heat-transfer coefficient.

    4. D

      It ensures that both fluids have the same temperature at every location.

    Correct answer
    C

    It allows wall-conduction and fouling resistances to be neglected when estimating the effective heat-transfer coefficient.

    Explanation

    A thin wall and the absence of fouling allow the wall and deposits to be treated as negligible thermal resistances. The fluid-side convection resistances still contribute to the effective heat-transfer coefficient.

  43. 43

    If a problem states that fluid and material properties are constant, how should properties be treated during the calculation?

    1. A

      Use representative fixed values rather than updating them continuously with temperature.

    2. B

      Assume the hot and cold fluids have identical properties.

    3. C

      Set every property equal to zero except the specific heat.

    4. D

      Use a different property value at every location despite the assumption.

    Correct answer
    A

    Use representative fixed values rather than updating them continuously with temperature.

    Explanation

    The constant-properties assumption means representative values are used throughout the analysis rather than recalculating properties at every local temperature.

  44. 44

    Why can a calculated outlet temperature be used to revise a property estimate in a more accurate analysis?

    1. A

      It proves that the fluid properties are constant at all temperatures.

    2. B

      It directly changes the number of tube passes in the exchanger.

    3. C

      It helps improve the estimated average temperature, which can improve the selected property value.

    4. D

      It establishes that the heat exchanger has no thermal resistance.

    Correct answer
    C

    It helps improve the estimated average temperature, which can improve the selected property value.

    Explanation

    An updated outlet temperature gives a better estimate of the stream's average temperature. The property can then be reselected and the calculation iterated if the application requires greater accuracy.

  45. 45

    For internal convection inside the tubes, what is the purpose of calculating the Reynolds number?

    1. A

      To calculate the log mean temperature difference without outlet temperatures.

    2. B

      To determine the number of shell passes from the tube diameter.

    3. C

      To identify the flow regime and select an appropriate convection correlation.

    4. D

      To find the fluid's specific heat from its mass flow rate alone.

    Correct answer
    C

    To identify the flow regime and select an appropriate convection correlation.

    Explanation

    The Reynolds number indicates the flow regime. That information is used to choose an appropriate Nusselt-number correlation for estimating the convection coefficient.

  46. 46

    In the tube-side convection analysis, what did the example conclude from a turbulent-flow Reynolds number?

    1. A

      The flow was treated as fully developed after one tube diameter.

    2. B

      The flow was treated as laminar throughout the exchanger.

    3. C

      The flow required no entrance-length check.

    4. D

      The flow was treated as fully developed after roughly ten tube diameters.

    Correct answer
    D

    The flow was treated as fully developed after roughly ten tube diameters.

    Explanation

    The example stated that turbulent flow becomes fully developed after about ten diameters, then checked whether the tube length was sufficient for that assumption to be reasonable.

  47. 47

    What does the Nusselt number help determine in an internal-convection analysis?

    1. A

      The capacity-rate ratio through Nu=Cmin⁡/Cmax⁡\mathrm{Nu}=C_{\min}/C_{\max}Nu=Cmin​/Cmax​

    2. B

      The mass flow rate through Nu=m˙cp\mathrm{Nu}=\dot{m}c_pNu=m˙cp​

    3. C

      The convection coefficient through Nu=hD/k\mathrm{Nu}=hD/kNu=hD/k

    4. D

      The heat-transfer area through Nu=UA/Cmin⁡\mathrm{Nu}=UA/C_{\min}Nu=UA/Cmin​

    Correct answer
    C

    The convection coefficient through Nu=hD/k\mathrm{Nu}=hD/kNu=hD/k

    Explanation

    The Nusselt number is defined as Nu=hD/k\mathrm{Nu}=hD/kNu=hD/k, where hhh is the convection coefficient, DDD is the tube diameter, and kkk is the fluid thermal conductivity. It can be rearranged to find hhh.

  48. 48

    Which fluid properties were needed from tables for the tube-side convection calculation?

    1. A

      Surface tension, vapor quality, emissivity, and latent heat

    2. B

      Tube roughness, shell thickness, fouling factor, and pressure

    3. C

      Only specific heat and mass flow rate

    4. D

      Density, viscosity, thermal conductivity, and Prandtl number

    Correct answer
    D

    Density, viscosity, thermal conductivity, and Prandtl number

    Explanation

    The example used density, viscosity, thermal conductivity, and Prandtl number for the internal-flow analysis, in addition to the flow and geometric information.

  49. 49

    When should the cold-side convection coefficient be found in a tube-side flow problem?

    1. A

      Only when the tube wall has significant axial conduction.

    2. B

      Only after the exchanger's total tube length has been specified.

    3. C

      Whenever the hot fluid flows outside the shell, even if both coefficients are given.

    4. D

      When the cold fluid flows inside the tubes and its convection coefficient is not provided.

    Correct answer
    D

    When the cold fluid flows inside the tubes and its convection coefficient is not provided.

    Explanation

    If the cold fluid flows through the tubes and its convection coefficient is not given, an internal-convection analysis is needed to determine it.

  50. 50

    In the shell-and-tube example, what was the approximate calculated length of one tube pass?

    1. A

      About 47 m47\,\text{m}47m

    2. B

      About 4.7 m4.7\,\text{m}4.7m

    3. C

      About 0.47 m0.47\,\text{m}0.47m

    4. D

      About 30 m30\,\text{m}30m

    Correct answer
    B

    About 4.7 m4.7\,\text{m}4.7m

    Explanation

    After calculating the required tube area and accounting for the number of tubes, passes, and tube diameter, the example found a length of about 4.7 m4.7\,\text{m}4.7m per pass.

  51. 51

    In the shell-and-tube example, how was the hot-oil mass flow rate determined from the cold-side data?

    1. A

      It was about 10 kg/s10\,\text{kg/s}10kg/s, found by doubling the number of tubes.

    2. B

      It was about 5.2 kg/s5.2\,\text{kg/s}5.2kg/s, found by balancing the heat gained by the cold stream with the heat lost by the hot stream.

    3. C

      It was about 2.5 kg/s2.5\,\text{kg/s}2.5kg/s, set equal to the specified cold-side flow rate.

    4. D

      It was about 0.52 kg/s0.52\,\text{kg/s}0.52kg/s, found from the tube diameter alone.

    Correct answer
    B

    It was about 5.2 kg/s5.2\,\text{kg/s}5.2kg/s, found by balancing the heat gained by the cold stream with the heat lost by the hot stream.

    Explanation

    The example calculated the heat transfer from the known cold-side conditions and used the hot-side energy balance to find a hot-oil mass flow rate of about 5.2 kg/s5.2\,\text{kg/s}5.2kg/s.

  52. 52

    In the thin-wall, no-fouling model, which thermal resistances contribute to the effective heat-transfer coefficient?

    1. A

      Only conduction resistance through the tube wall

    2. B

      Only fouling resistance on the hot side

    3. C

      Axial conduction resistance and radiation resistance

    4. D

      The convection resistances on the hot and cold fluid sides

    Correct answer
    D

    The convection resistances on the hot and cold fluid sides

    Explanation

    With tube-wall conduction and fouling resistances neglected, the effective coefficient is determined by the convection resistances on the two fluid sides.

Question 1 of 52
Question 1 of 52

Ask anything

We've read this whole study set, so questions about it get the best answers.

FlashcardsQuizFill in the blanksWritten testLessonNotesPodcastContent