For a heat exchanger with no heat loss to the surroundings, how are the heat transfer rates on the hot and cold sides related?

Tap to flipClick to flipspace

The heat lost by the hot fluid equals the heat gained by the cold fluid in magnitude.

Or swipe the card

53 cards

  1. For a heat exchanger with no heat loss to the surroundings, how are the heat transfer rates on the hot and cold sides related?

    The heat lost by the hot fluid equals the heat gained by the cold fluid in magnitude.

  2. How is heat transfer related to a fluid’s mass flow rate, specific heat, and temperature change when there is no phase change?

    Q=m˙cpΔTQ=\dot{m}c_p\Delta TQ=m˙cp​ΔT.

  3. What is a fluid’s heat capacity rate?

    C=m˙cpC=\dot{m}c_pC=m˙cp​.

  4. What does a steady-state assumption mean in a heat exchanger analysis?

    Conditions do not change with time.

  5. What does assuming constant fluid and material properties mean?

    Properties such as specific heat are treated as constant throughout the analysis.

  6. What does an adiabatic heat exchanger assumption rule out?

    Heat loss to the surroundings; heat leaving one fluid is assumed to enter the other.

  7. Why might axial conduction along a heat exchanger tube be neglected?

    It is assumed to be small compared with the heat transfer between the fluids.

  8. What is the effect of assuming a thin, clean tube wall when calculating the overall heat transfer coefficient?

    Tube-wall conduction resistance and fouling resistances are neglected.

  9. With a fixed tube diameter, how does heat transfer area relate to tube length?

    A=πDLA=\pi D LA=πDL for one tube; increasing the length increases the area.

  10. If tube-wall and fouling resistances are negligible, how is the effective heat transfer coefficient related to the two convection coefficients?

    1U=1hi+1ho\frac{1}{U}=\frac{1}{h_i}+\frac{1}{h_o}U1​=hi​1​+ho​1​.

  11. When estimating a fluid’s specific heat from a property table, why might an approximate average temperature be adequate?

    In the examples, specific heat varies only weakly with temperature, so a reasonable estimate often changes the result little.

  12. For saturated water, which table specific heat is appropriate for liquid water: cp,fc_{p,f}cp,f​ or cp,gc_{p,g}cp,g​?

    Use cp,fc_{p,f}cp,f​ for saturated liquid; cp,gc_{p,g}cp,g​ refers to saturated vapor.

  13. When sizing a heat exchanger with the log mean temperature difference method, what is the basic heat-transfer equation?

    Q=UAΔTlmQ=UA\Delta T_{lm}Q=UAΔTlm​.

  14. What is the equation for log mean temperature difference?

    ΔTlm=ΔT1−ΔT2ln⁡(ΔT1/ΔT2)\Delta T_{lm}=\frac{\Delta T_1-\Delta T_2}{\ln(\Delta T_1/\Delta T_2)}ΔTlm​=ln(ΔT1​/ΔT2​)ΔT1​−ΔT2​​.

  15. What temperature information is needed to apply the log mean temperature difference method directly?

    The inlet and outlet temperatures of both fluids.

  16. In a parallel-flow heat exchanger, which fluid temperatures form the terminal differences?

    ΔT1=Th,in−Tc,in\Delta T_1=T_{h,in}-T_{c,in}ΔT1​=Th,in​−Tc,in​ and ΔT2=Th,out−Tc,out\Delta T_2=T_{h,out}-T_{c,out}ΔT2​=Th,out​−Tc,out​.

  17. In a counterflow heat exchanger, which fluid temperatures form the terminal differences?

    ΔT1=Th,in−Tc,out\Delta T_1=T_{h,in}-T_{c,out}ΔT1​=Th,in​−Tc,out​ and ΔT2=Th,out−Tc,in\Delta T_2=T_{h,out}-T_{c,in}ΔT2​=Th,out​−Tc,in​.

  18. How does counterflow affect the temperature difference along a heat exchanger compared with parallel flow?

    Counterflow generally maintains a more consistent temperature difference along the exchanger.

  19. In the example cooling a hot fluid from 80°C to 50°C with a cold-fluid inlet at 15°C, what was the heat transfer rate?

    210 kW.

  20. In the example, what was the estimated cold-fluid outlet temperature?

    35°C.

  21. For the example’s parallel-flow configuration, what were the terminal temperature differences and log mean temperature difference?

    The terminal differences were 65°C and 15°C; the log mean temperature difference was 34.1°C.

  22. For the example’s counterflow configuration, what were the terminal temperature differences and log mean temperature difference?

    The terminal differences were 45°C and 35°C; the log mean temperature difference was 39.8°C.

  23. What heat transfer areas were calculated for the example’s parallel-flow and counterflow configurations?

    Parallel flow required 3.13 m²; counterflow required 2.68 m².

  24. By approximately how much did counterflow reduce the required area in the example?

    About 14%.

  25. When is the effectiveness–NTU method especially useful compared with the log mean temperature difference method?

    It is useful for more complicated exchanger geometries and when outlet temperatures are unknown.

  26. What is heat exchanger effectiveness?

    ε=QactualQmax\varepsilon=\frac{Q_{actual}}{Q_{max}}ε=Qmax​Qactual​​.

  27. How is the maximum possible heat transfer rate calculated?

    Qmax=Cmin(Th,in−Tc,in)Q_{max}=C_{min}(T_{h,in}-T_{c,in})Qmax​=Cmin​(Th,in​−Tc,in​).

  28. How are the minimum and maximum heat capacity rates identified?

    CminC_{min}Cmin​ is the smaller of the two fluid heat capacity rates, and CmaxC_{max}Cmax​ is the larger.

  29. What is the heat capacity ratio used in effectiveness–NTU analysis?

    Cr=CminCmaxC_r=\frac{C_{min}}{C_{max}}Cr​=Cmax​Cmin​​.

  30. What is the number of transfer units, or NTU?

    NTU=UACminNTU=\frac{UA}{C_{min}}NTU=Cmin​UA​.

  31. How can the effectiveness–NTU method be used to size an exchanger when outlet temperatures are known?

    Find QQQ and effectiveness from the energy balance and inlet/outlet temperatures, use the geometry correlation to find NTU, then calculate A=NTUCminUA=\frac{NTU C_{min}}{U}A=UNTUCmin​​.

  32. How can the effectiveness–NTU method find heat transfer when exchanger area and inlet conditions are known?

    Calculate NTU and CrC_rCr​, use the geometry correlation to find effectiveness, then calculate Qactual=εQmaxQ_{actual}=\varepsilon Q_{max}Qactual​=εQmax​.

  33. Why can an energy balance determine one fluid’s outlet temperature once heat transfer is known?

    Because Q=m˙cpΔTQ=\dot{m}c_p\Delta TQ=m˙cp​ΔT relates the heat transfer to that fluid’s temperature change.

  34. What must be known to use the effectiveness–NTU correlation for a particular exchanger?

    The exchanger geometry and flow arrangement, along with CrC_rCr​ and either effectiveness or NTU.

  35. What distinguishes a shell-and-tube exchanger with one shell pass and an even number of tube passes?

    The shell-side fluid makes one pass, while the tube-side fluid makes an even number of passes through the shell.

  36. In a shell-and-tube exchanger, what do baffles do?

    They direct the shell-side flow across the tubes in repeated passes.

  37. How was the hot-oil mass flow rate found in the shell-and-tube example?

    The cold-side heat transfer was calculated from known cold-side conditions, then an energy balance was used to find the hot-side mass flow rate.

  38. What hot-oil mass flow rate and heat transfer rate were calculated in the shell-and-tube example?

    The hot-oil mass flow rate was 5.2 kg/s, and the heat transfer rate was about 190 kW.

  39. In the shell-and-tube example, which side had the minimum heat capacity rate, and what was CrC_rCr​?

    The cold side had CminC_{min}Cmin​, and CrC_rCr​ was approximately 0.86.

  40. What effectiveness and NTU were calculated for the shell-and-tube example?

    Effectiveness was 0.483, and NTU was approximately 1.

  41. Why was an internal convection analysis needed in the shell-and-tube example?

    The tube-side heat transfer coefficient was not given, so it had to be calculated from the tube flow conditions.

  42. What flow regime and fully developed-flow check were reported for the tube-side flow in the shell-and-tube example?

    The flow was turbulent, and it becomes fully developed after about 10 tube diameters.

  43. What Nusselt number and effective heat transfer coefficient were obtained in the shell-and-tube example?

    The Nusselt number was about 120, and the effective heat transfer coefficient was 354 W/(m²·K).

  44. How is total tube surface area related to the number of tubes, tube diameter, and tube-pass length?

    A=NtubesπDNpassesLA=N_{tubes}\pi D N_{passes}LA=Ntubes​πDNpasses​L.

  45. In the shell-and-tube example, what area and length per tube pass were calculated?

    The required area was nearly 30 m², and the length per pass was about 4.7 m.

  46. What does “unmixed” mean for a fluid in a crossflow heat exchanger?

    The flow is divided into separate channels or tubes that do not mix with one another.

  47. What crossflow arrangement was used in the truck-coolant example?

    Both fluids were unmixed: water flowed through tubes, and air flowed through separate channels across them.

  48. Why was the effectiveness–NTU method used for the crossflow example?

    Neither outlet temperature was known, so the terminal temperature differences required for the log mean temperature difference method were unavailable.

  49. What crossflow correlation applies when both fluids are unmixed and each makes a single pass?

    Use the effectiveness relationship for single-pass crossflow with both fluids unmixed.

  50. In the crossflow example, which fluid had the smaller heat capacity rate, and what was the capacity-rate ratio?

    The hot water had the smaller heat capacity rate, and CrC_rCr​ was about 0.2.

  51. What NTU and effectiveness were calculated for the crossflow example?

    NTU was about 0.5, and effectiveness was about 0.37.

  52. What maximum and actual heat transfer rates were calculated for the crossflow example?

    The maximum was about 4.8 kW, and the actual heat transfer was about 1.8 kW.

  53. What hot-water outlet temperature was calculated for the crossflow example?

    58.3°C.

Card 1 of 53